5
SPAN (FT) RISE (FT) WALL (IN) A (IN) OAW (IN) TONS PER FT 6 3 7 32 86 1.04 6 4 7 32 86 1.13 6 5 7 32 86 1.22 6 6 7 32 86 1.30 7 3 8 46 100 1.29 7 4 8 46 100 1.39 7 5 8 46 100 1.49 7 6 8 46 100 1.59 7 7 8 46 100 1.69 8 3 8 58 112 1.39 8 4 8 58 112 1.49 8 5 8 58 112 1.59 8 6 8 58 112 1.69 8 7 8 58 112 1.79 8 8 8 58 112 1.89 9 3 9 72 126 1.67 9 4 9 72 126 1.78 9 5 9 72 126 1.90 9 6 9 72 126 2.01 9 7 9 72 126 2.12 9 8 9 72 126 2.23 9 9 9 72 126 2.35 10 3 10 86 140 1.99 10 4 10 86 140 2.11 10 5 10 86 140 2.24 10 6 10 86 140 2.36 10 7 10 86 140 2.49 10 8 10 86 140 2.61 10 9 10 86 140 2.87 10 10 10 86 140 2.99 11 3 11 100 154 2.32 11 4 11 100 154 2.46 11 5 11 100 154 2.60 11 6 11 100 154 2.74 11 7 11 100 154 2.87 11 8 11 100 154 3.01 11 9 11 100 154 3.15 11 10 11 100 154 3.29 11 11 11 100 154 3.43 12 3 12 114 168 2.70 12 4 12 114 168 2.85 12 5 12 114 168 3.00 12 6 12 114 168 3.15 12 7 12 114 168 3.30 12 8 12 114 168 3.45 12 9 12 114 168 3.60 12 10 12 114 168 3.75 12 11 12 114 168 3.90 12 12 12 114 168 4.05 BOX CULVERT BOX CULVERT STANDARD DETAIL 4.1 RISE SPAN WALL (4) Ø3" LIFT HOLES R1 1/2" (TYP) 12" 12" A 1'-8 1/2" 3'-4" 1'-4" 6'-0" 4 1/2" OAW MATERIALS : CONCRETE: 5,000 PSI, TYPE I/II CEMENT TYPICAL BOXES CONFORM TO ASTM C-1433 NOTES: SPECIAL DESIGN BOX CULVERT AVAILABLE FOR INCREASED LOADS PARTS SHOWN : 10'-0" x 6'-0" x 6'-0" SECTION BOX CULVERT

Transcript of BOX CULVERT - Foley Products · box culvert standard box culvert joint detail 4.2 materials:...

Page 1: BOX CULVERT - Foley Products · box culvert standard box culvert joint detail 4.2 materials: concrete: 5,000 psi, type i/ii cement parts shown: span 8' x rise 6' bell-end spigot-end

SPAN(FT)

RISE(FT)

WALL(IN)

A(IN)

OAW(IN)

TONSPER FT

6 3 7 32 86 1.046 4 7 32 86 1.136 5 7 32 86 1.226 6 7 32 86 1.30

7 3 8 46 100 1.297 4 8 46 100 1.397 5 8 46 100 1.497 6 8 46 100 1.597 7 8 46 100 1.69

8 3 8 58 112 1.398 4 8 58 112 1.498 5 8 58 112 1.598 6 8 58 112 1.698 7 8 58 112 1.798 8 8 58 112 1.89

9 3 9 72 126 1.679 4 9 72 126 1.789 5 9 72 126 1.909 6 9 72 126 2.019 7 9 72 126 2.129 8 9 72 126 2.239 9 9 72 126 2.35

10 3 10 86 140 1.9910 4 10 86 140 2.1110 5 10 86 140 2.2410 6 10 86 140 2.3610 7 10 86 140 2.4910 8 10 86 140 2.6110 9 10 86 140 2.8710 10 10 86 140 2.99

11 3 11 100 154 2.3211 4 11 100 154 2.4611 5 11 100 154 2.6011 6 11 100 154 2.7411 7 11 100 154 2.8711 8 11 100 154 3.0111 9 11 100 154 3.1511 10 11 100 154 3.2911 11 11 100 154 3.43

12 3 12 114 168 2.7012 4 12 114 168 2.8512 5 12 114 168 3.0012 6 12 114 168 3.1512 7 12 114 168 3.3012 8 12 114 168 3.4512 9 12 114 168 3.6012 10 12 114 168 3.7512 11 12 114 168 3.9012 12 12 114 168 4.05

BOX CULVERT

BOX CULVERT STANDARD DETAIL4.1

RISE

SPANWALL

(4) Ø3" LIFT HOLESR1 1/2"(TYP)

12"

12"

A1'-8 1/2"

3'-4"

1'-4"

6'-0"

4 1/2"OAW

MATERIALS:CONCRETE: 5,000 PSI, TYPE I/II CEMENTTYPICAL BOXES CONFORM TO ASTM C-1433

NOTES:SPECIAL DESIGN BOX CULVERT AVAILABLE FOR INCREASED LOADS

PARTS SHOWN:10'-0" x 6'-0" x 6'-0" SECTION BOX CULVERT

Page 2: BOX CULVERT - Foley Products · box culvert standard box culvert joint detail 4.2 materials: concrete: 5,000 psi, type i/ii cement parts shown: span 8' x rise 6' bell-end spigot-end

BOX CULVERT

STANDARD BOX CULVERT JOINT DETAIL4.2

MATERIALS:CONCRETE: 5,000 PSI, TYPE I/II CEMENT

PARTS SHOWN:SPAN 8' x RISE 6'

SPIGOT-ENDBELL-END

4"3 7/32"R7/8"

R1 3/8"

R7/8"

R1 3/8"

1/2"

4 1/2"

WT

Page 3: BOX CULVERT - Foley Products · box culvert standard box culvert joint detail 4.2 materials: concrete: 5,000 psi, type i/ii cement parts shown: span 8' x rise 6' bell-end spigot-end

HERMITAGE,TNFRANKLIN,TN

LENOIR CITY,TNCHATANOOGA,TN

Page 4: BOX CULVERT - Foley Products · box culvert standard box culvert joint detail 4.2 materials: concrete: 5,000 psi, type i/ii cement parts shown: span 8' x rise 6' bell-end spigot-end

HERMITAGE,TNFRANKLIN,TN

LENOIR CITY,TNCHATANOOGA,TN

Page 5: BOX CULVERT - Foley Products · box culvert standard box culvert joint detail 4.2 materials: concrete: 5,000 psi, type i/ii cement parts shown: span 8' x rise 6' bell-end spigot-end

HERMITAGE,TNFRANKLIN,TN

LENOIR CITY,TNCHATANOOGA,TN