Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based...

29
Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC- based Automation Support New SIMATIC WinAC features A&D AS, 07/2004, Chart 1 © Siemens AG 2004 - Subject to change without prior notice PC- based Control All about SIMATIC WinAC Automation and Drives

Transcript of Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based...

Page 1: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 1 © Siemens AG 2004 - Subject to change without prior notice

PC-basedControl All about SIMATIC WinAC

Automation and Drives

Page 2: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 2 © Siemens AG 2004 - Subject to change without prior notice

Innovation in PC technology

Automation technology will participate in the rapid innovation

in PC technology!Why PC-basedAutomation?

Statement from Intel: „22 Ghz in 2008“

Page 3: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 3 © Siemens AG 2004 - Subject to change without prior notice

Integration of automation solution on a hardware platform

on one single PC

Cost reduction through integration of

Why PC-basedAutomation? Visualization Control

Data processing Networks

Page 4: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 4 © Siemens AG 2004 - Subject to change without prior notice

Openness of PC technology

open standards

Increased flexibility through use of

OfficeControl application

Why PC-basedAutomation?

Page 5: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 5 © Siemens AG 2004 - Subject to change without prior notice

Totally Integrated Automation

Manufacturing ExecutionSystems (MES)

TotallyIntegratedAutomation

Control

Enterprise ResourcePlanning (ERP)

MES Solutions

Inbound LogisticsProcess

DiscreteOutbound Logistics

ProductionWorkflow

Design andEngineering

Installation andCommissioning Operation Maintenance

Modernizationand Upgrade

ProductionLife Cycle

PC-based Control with SIMATIC

Page 6: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 6 © Siemens AG 2004 - Subject to change without prior notice

Technische Folien

Engineering with STEP 7

SIMATIC S7/C7PC basedControl

EmbeddedControl

Version 5.3

Re-use of available SIMATIC Know how

Save your software investment

PC-based Control with SIMATIC

Page 7: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 7 © Siemens AG 2004 - Subject to change without prior notice

Technical slides

Standard interface inclusive

Production visualizationSIMATIC WinCC

flexible

Process visualizationSIMATIC WinCC

Visualization system

on Windows

3rd party

SIMATIC communication

WinAC

Flexibility through use of open standards

PC-based Control with SIMATIC

                                                                     

                                                                                         

                                                                   

Page 8: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 8 © Siemens AG 2004 - Subject to change without prior notice

SIMATIC NET OPC

Unified OPC-Solution for SIMATIC

Improved Performance(about 5x – 10x)

Improved Configuration with STEP7

Variable-Browsing

OPC-Interfaces:

Data Access

Alarms&Events

Successor of SIMATIC Computing

PC with Windows

PC Internal

CPWinAC

…New SIMATICWinAC features

Page 9: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 9 © Siemens AG 2004 - Subject to change without prior notice

Multi-PLC Support

Reduced HW-cost,reduced space (less PCs)

Communication using BSEND/BRCV

Distributed control power

< 4 WinAC Slot PLC

1 WinAC Software PLC +< 3 WinAC Slot PLC

External Power Supply: 1 PS Extension Board per WinAC Slot required

More compact and cost-effective Automation Solution

New SIMATICWinAC features

Page 10: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 10 © Siemens AG 2004 - Subject to change without prior notice

More Motion Solutions with WinAC Slot

FM 353/354

Support of additional FMs:

FM 353: Stepper Motor

FM 354: Servo Motor

Point to point positioning

Complex traversing patterns

Motion control solutions with SIMOVERT MASTERDRIVES

Electronic Gear

Motion with WinAC

ET200M

MASTERDRIVES

New SIMATICWinAC features

Page 11: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 11 © Siemens AG 2004 - Subject to change without prior notice

Operation with Simple PC User Privileges

Installation: Admin or Local Admin

privileges required

Operation: User or Power User

privileges sufficient RUN/STOP/MRES Read diagnostic buffer Restoring of archive files Tuning

Safety: Panel pass word

Simplified Operation, Maintenance and Service

New SIMATICWinAC features

Page 12: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 12 © Siemens AG 2004 - Subject to change without prior notice

Firmware-Update via File

Start FW update via menu command

No more memory card needed

No more creation of „update memory card“ with STEP7

Note: new HW release 3 required

Upgrade of HW for existing WinAC Slot PLCs required

Simplified Maintenance and Service

FW Update ...

New SIMATICWinAC features

Page 13: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 13 © Siemens AG 2004 - Subject to change without prior notice

WinAC PN Option für WinAC Basis

Modular, distributed Automation with WinAC Basis

Integration of PROFInet into WinAC standard products

Used for Component based Automation

Replacement of WinAC PN V1.1

Option package for WinAC Basis

Ethernet

PROFIBUS

Components with distributed I/O on

PROFIBUS

Innovations and Trends with PC based Control Products

New SIMATICWinAC features

Page 14: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 14 © Siemens AG 2004 - Subject to change without prior notice

Performance for WinAC Software PLCs

Notes for Measurement:

32000 Operations(32 loops à 1000)

Performance values depending on processor type!

Performance values depending on program structure!

0

500

1000

1500

2000

2500

3000

3500

4000

Bool Integer Float

µs

WinAC Basis V3.0 @1.26Ghz PIII

WinAC RTX V4.0 @1.2Ghz Celeron

WinAC RTX V4.1 @1.2Ghz Celeron

0

200

400

600

800

1000

1200

1400

1600

1800

Bool Integer Float

WinAC Basis V3.0 @3.06Ghz Xeon

WinAC RTX V3.1 @3.06Ghz Xeon

WinAC RTX V4.0 @3.06Ghz Xeon

WinAC RTX V4.1 @3.06Ghz Xeon Performance

x 2

1,2 GHz Celeron

3 GHz Xeon (P

4)

New SIMATICWinAC features

Page 15: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 15 © Siemens AG 2004 - Subject to change without prior notice

Integration of T-Kit und ODK:WinAC ODK V4.1

One C/C++ engineering package forr WinAC Software and Slot PLCs

Wizard supported programming for run-time interfaces for WinAC Software and Slot PLCs:

ODKV4.1

Microsoft Visual Studio

Custom Code Extension(„ODK-Interface“)

Shared Memory Extension(„T-Kit-Interface“)

Controller Management Interface (NEW)

Soft

Slo

t

Wiz

ard

Integration of Custom Functions

New SIMATICWinAC features

Page 16: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 16 © Siemens AG 2004 - Subject to change without prior notice

WinAC ODK V4.1

WinAC Software PLCV4.1

WinAC Slot PLCV3.4

CCX SMXCMI SMXCMI

T-Kit DLL

WinAC Slot T-Kit V3.3

Custom Application(C/C++)

WinAC ODK V4.0

Custom Application(C/C++)

WinAC ODK V4.1

Custom Application (C/C++)New SIMATICWinAC features

Page 17: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 17 © Siemens AG 2004 - Subject to change without prior notice

CCX: Custom Code Extension Interface

Backward compatible to existing ODK Interface New:

Operand Access –access to WinAC data at any time Programming with Visual Developer‘s Studio .net

Compatibility WinAC ODK V4.0 can still be used with WinAC

Basis/RTX V4.1 Applications created with WinAC ODK V4.0 can be used

with WinAC Basis/RTX V4.1 without any restrictions Applications created with WinAC Basis/RTX ODK V3.0

can be used with WinAC V4.1 with the same restrictions as with WinAC Basis/RTX V4.0

New SIMATICWinAC features

Extend your PLC funktionality

Page 18: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 18 © Siemens AG 2004 - Subject to change without prior notice

SMX: Shared Memory Extension Iterface

Enhancement of T-Kit interface New:

Simplified DLL interface Supports Multi-CPU operation Support of WinAC Software PLCs planed

Compatibility: WinAC Slot T-Kit V3.3 can be used with WinAC Slot

V3.4 Applications created with WinAC Slot T-Kit V3.3 can be

used with WinAC Slot V3.4 w/o restrictions; WinAC Slot will provide a “Compatibility DLL”

New SIMATICWinAC features

High performance data interchange between Windows-applications and SIMATIC WinAC

Page 19: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 19 © Siemens AG 2004 - Subject to change without prior notice

CMI: Controller Management Interface

New: enables integration of WinAC CPU Panel functionality into a custom application

RUN/STOP/LED-status Archiving/reloading of PLC programs Start and shutdown of the PLC

Examples: Complete integration of CPU Panel functions into a HMI

application („Service- und Maintenance pages“) Remote CPU Panel Implementation of specific user rights Automatic reloading of PLC program updates

New SIMATICWinAC features

Flexible operation of the PLC´s

Page 20: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 20 © Siemens AG 2004 - Subject to change without prior notice

Overview new WinAC Features

WinAC Soft

WinAC Slot

Integration of SIMATIC NET OPC Server Multi-CPU Support More Motion Solutions Operation with Simple PC User Privileges Firmware-Update via File PROFInet Support (CbA) Performance x2 Integration of T-Kit into WinAC ODK V4.1

New SIMATICWinAC features

Page 21: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 21 © Siemens AG 2004 - Subject to change without prior notice

Technical slides

SIMATIC WinAC Basis V4.1

Based on native Windows standard

I/O connection via PROFIBUS-DP (12 Mbit/s)

Retentive data with UPS support(UPS = uninterruptible power supply)

Full utilization of PC memory

Saving of data and program on hard disk

Highest flexibility for theautomation solution throughintegration of windows-applications

Product overview

For data-intensive tasks

Page 22: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 22 © Siemens AG 2004 - Subject to change without prior notice

Technical slides

SIMATIC WinAC RTX V4.1

For applications with high requirements to determinism and real-time behavior

Based on standard Windows NT and Real Time eXtension from VenturCom

I/O connection using PROFIBUS DP card (12 Mbit/s)

Up to four PROFIBUS lines possible

Retentive data with UPS support(UPS = uninterruptible power supply)

Utilization of PC main memory

Saving of data and program on hard disk

For real-time tasks

Product overview

Page 23: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 23 © Siemens AG 2004 - Subject to change without prior notice

Technical slides

SIMATIC WinAC Slot V3.4

Available in two versions:WinAC Slot 412-2DP (128 kB per code/data)WinAC Slot 416-2DP (1.6 MB per code/data)

Control independent of Windows 2000 or Windows XP

Set of commands and performance correspond to the powerful S7-400 CPUs

Data retention through battery backup Two DP interfaces onboard Optional 24 V power supplyProduct

overview

With own safety on board

Page 24: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 24 © Siemens AG 2004 - Subject to change without prior notice

Technical slides

SIMATIC WinAC ODK 4.1

SIMATIC WinAC ODK is an engineering package which supports the development of C/C++ applications for WinAC Software and Slot PLCs.

Extend the WinACcontrol-functionality

Accelerate theData-Interchange

Integration of PC-Soft andHardware into WinAC

OB 1

LAD,STL,

CSLCFC,

Graph7,

Higraph

SCL

C++

WinACrange

Product overview

improve the productivity through Integration of C++ applications

Page 25: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 25 © Siemens AG 2004 - Subject to change without prior notice

World of PC-based Automation

World of PC-based Automation

The complete PC-based solution from one source!

Page 26: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 26 © Siemens AG 2004 - Subject to change without prior notice

3rd party add-ons

Incorporation of otherfieldbuses Integration of various

data formats

Linking of automationtechnology and instrumentation

World of PC-based Automation

Other vendors use WinAC's openness to achieve integration into the SIMATIC automation concept!

Integration of 3rd party add on´s

Page 27: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 27 © Siemens AG 2004 - Subject to change without prior notice

PC-based Competence Centers

Detroit

Milan

Cologne

Shanghai

Support

Worldwide project support for implementation of your solution from feasibility analysis up to implementation!

Worldwide Competence in PC-based automation

Page 28: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 28 © Siemens AG 2004 - Subject to change without prior notice

Internet / knowledge base

Support

The latest informationon PC-based Automation

from Siemens canalways be found here

www.pcbasedautomation.com

Page 29: Automation and Drives SIMATIC WinAC PC-based Control SIMATIC WinAC Why PC-based Automation? PC-based Control with SIMATIC Product overview World of PC-based.

Automation and Drives

SIMATIC WinAC

PC-based ControlSIMATIC WinACWhy PC-basedAutomation?

PC-based Control with SIMATIC

Product overview

World of PC-based Automation

Support

New SIMATIC WinAC features

A&D AS, 07/2004, Chart 29 © Siemens AG 2004 - Subject to change without prior notice

PC-basedControl The Integration-Plattform for yourPC-based Solution

Automation and Drives