ASSA ABLOY - E.D. Locks · ASSA ABLOY 80-9357-0140-020 (01-14) 3 17. Flip the dip switch on the...

4
Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 80-9357-0140-020 (01-14) These instructions are used to change the application of a 5700 operator from a Push Side unit to a Pull side unit. 1. The unit shown in fig.1 is configured for a push side application. Note the valve orientation of the closer body. The photo in fig.2 shows a close-up view of the clutch mechanism configured for push side application. 2. Remove the four screws which secure the closer body to the backplate. 3. Slide the closer body away from the clutch assembly and chain. Make sure you do not remove pinion extension when removing closer body from clutch mechanism. 4. Orient the closer body as shown in fig. 3, with “BC” valve toward conduit holes, and slide onto backplate so that closer pinion is inserted into pinion extension. Some rotational adjustment of the pinion extension may be required to allow assembly of closer pinion and pinion extension. 5. Replace and tighten closer body screws removed in step 2. See fig. 4. 6. Flip the dip switch on the inverter from the Push to the Pull position, see fig. 5. Instructions continued on page 2. Fig.1 Sweep & Latch Valves Pinion Extension Cam Driver Fig.3 Fig.4 Fig.2 Fig.5 1 - Push/Pull Dip Switch 2 - Push Recognition 5700 Power Operator Conversion Push to Pull / Pull to Push Application Patents: 5,881,497; 7,316,096; 7,484,333 ASSA ABLOY

Transcript of ASSA ABLOY - E.D. Locks · ASSA ABLOY 80-9357-0140-020 (01-14) 3 17. Flip the dip switch on the...

Page 1: ASSA ABLOY - E.D. Locks · ASSA ABLOY 80-9357-0140-020 (01-14) 3 17. Flip the dip switch on the inverter from the Pull to the Push position, see fig. 13. 13. Remove the four screws

Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

ASSA ABLOY

80-9357-0140-020 (01-14)1

These instructions are used to change the application of a 5700 operator from a Push Side unit to a Pull side unit.

1. The unit shown in fig.1 is configured for a push side application. Note the valve orientation of the closer body. The photo in fig.2 shows a close-up view of the clutch mechanism configured for push side application.

2. Remove the four screws which secure the closer body to the backplate.

3. Slide the closer body away from the clutch assembly and chain. Make sure you do not remove pinion extension when removing closer body from clutch mechanism.

4. Orient the closer body as shown in fig. 3, with “BC” valve toward conduit holes, and slide onto backplate so that closer pinion is inserted into pinion extension. Some rotational adjustment of the pinion extension may be required to allow assembly of closer pinion and pinion extension.

5. Replace and tighten closer body screws removed in step 2. See fig. 4.

6. Flip the dip switch on the inverter from the Push to the Pull position, see fig. 5.

Instructions continued on page 2.

Fig.1

Sweep & LatchValves

PinionExtension

CamDriver

Fig.3

Fig.4

Fig.2

Fig.5

1 - Push/Pull Dip Switch2 - Push Recognition

5700 Power Operator ConversionPush to Pull / Pull to Push Application

Patents: 5,881,497; 7,316,096; 7,484,333

ASSA ABLOY

Page 2: ASSA ABLOY - E.D. Locks · ASSA ABLOY 80-9357-0140-020 (01-14) 3 17. Flip the dip switch on the inverter from the Pull to the Push position, see fig. 13. 13. Remove the four screws

Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

ASSA ABLOY

80-9357-0140-020 (01-14)2

9. With door closed, slide Closed Position Magnet so it aligns with the Reed Switch. See fig. 8.

10. Slide Open Position Magnet so it is 180° from the Reed Switch. See fig. 9. Slide Open Position Magnet as needed to get proper door opening.

11. Continue to page 4.

Fig.8

Closed PositionMagnet

Reed Switch

Fig.9

Open PositionMagnet

Reed Switch

7. Verify switch is in the “ON” position for the circuit breaker and activate unit.

8. Immediately after activating the unit, watch the Cam Driver, fig. 6, as it rotates around. As soon as the Cam Driver contacts the Pinion Extension, flip the circuit breaker switch to the “RESET” position.

PinionExtension

CamDriver

PinionFlat

Fig.6

Fig.7

PinionExtension

CamDriver

PinionFlat

Fig.11Fig.10

PinionExtension

CamDriver

PinionFlat

These instructions are used to change the application of a 5700 operator from a Pull Side unit to a Push side unit.

12. The unit shown in fig.10 is configured for a pull side application. Note the valve orientation of the closer body. The photo in fig.11 shows a close-up view of the clutch mechanism configured for pull side application.

Instructions continued on page 3.

Page 3: ASSA ABLOY - E.D. Locks · ASSA ABLOY 80-9357-0140-020 (01-14) 3 17. Flip the dip switch on the inverter from the Pull to the Push position, see fig. 13. 13. Remove the four screws

Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

ASSA ABLOY

80-9357-0140-020 (01-14)3

17. Flip the dip switch on the inverter from the Pull to the Push position, see fig. 13.

13. Remove the four screws which secure the closer body to the backplate.

14. Slide the closer body away from the clutch assembly and chain. Make sure you do not remove pinion extension when removing closer body from clutch mechanism.

15. Orient the closer body with “Latch” and “Sweep” valves toward conduit holes, and slide onto backplate so that closer pinion is inserted into pinion extension. Some rotational adjustment of the pinion extension may be required to allow assembly of closer pinion and pinion extension.

16. Replace and tighten closer body screws removed in step 12. See fig. 12.

Fig.12

Sweep & LatchValves

Fig.13

20. With door closed, slide Closed Position Magnet so it aligns with the Reed Switch. See fig. 15.

21. Slide Open Position Magnet so it is 180° from the Reed Switch. See fig. 16. Slide Open Position Magnet as needed to get proper door opening.

22. Continue to page 4.

PinionExtension

CamDriver

18. Verify switch is in the “ON” position for the circuit breaker and activate unit.

19. Immediately after activating the unit, watch the Cam Driver, fig. 14, as it rotates around. As soon as the Cam Driver contacts the Pinion Extension, flip the circuit breaker switch to the “RESET” position.

Fig.14

Instructions continued on page 4.

Fig.15

Closed PositionMagnet

Reed Switch

Fig.16

Open PositionMagnet

Reed Switch

1 - Push/Pull Dip Switch2 - Push Recognition

Page 4: ASSA ABLOY - E.D. Locks · ASSA ABLOY 80-9357-0140-020 (01-14) 3 17. Flip the dip switch on the inverter from the Pull to the Push position, see fig. 13. 13. Remove the four screws

Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

ASSA ABLOY

80-9357-0140-020 (01-14)4

Inverter Adjustments: Based on function adjustment desired, use table above to

determine which POT is to be adjusted.

POT FUNCTIONDESCRIPTION

OBSTR SENS Obstruction Detection on Open CW - IncreaseCCW - Decrease

M/DLY Motor Delay on Opening CW - IncreaseCCW - Decrease

P1 Closing Speed CW - IncreaseCCW - Decrease

H/O TM Hold Open Time (5 - 30 Seconds) CW - IncreaseCCW - Decrease

P2 Opening Speed CW - IncreaseCCW - Decrease

H/O TQMotor Torque at Hold Open Position

CW - IncreaseCCW - Decrease

ON

12

WARNING

120 HIGH VOLT POTENTIAL PRESENT. MAKE SURE POWER IS TURNED OFF DURING

INSTALLATION PROCEDURE.

Dip Switch Settings

1. Door Mounting -

2. Push Recognition -

ON - pullOFF - pushON - activeOFF - inactive

WARNINGElectric

Shock Risk

L2115Y

L1 115/230VAC IN

MOTOR OUT

L2230Y

U

V

W

STATUS LEDS

PU

LL P

US

HSW501

H/O TQH/O TM

OBSTRSENSP1

M/DLY P2

ON

12

16

COM

SNS

COM

PB

K1

K2

11

JMP503

NC

NO

TB501

(Adjustments made in the shaded area should be performed by

Authorized Factory Personnel.)

Inverter Details

23. Turn circuit breaker to the “ON” position.24. Rotate Open position magnet until door opens to desired position.

3000 Highway 74 East • Monroe, NC 28112Tel: (877)- • Fax: (800)-338-0965974-2255

www.nor tondoorcontrols.com

ASSA ABLOY