    SCREENTEC VERTICAL BAR SCREEN

    Screentec is customized based on specifications and/or structural constraints.

    Below are some guidelines of the design requirements.

    MATERIALS

    SPACE REQUIREMENTS - FOOTPRINT 

    MOTOR CHARACTERISTICS

    304 or 316 stainless steel

    Applications: Municipal & Industrial

    Depth: up to 50’ (15m)

    Absorbed power: ¾hp (0.56 KW)

    Surface treatment: Scouring, Passivation

    Flow capacity: up to 60mgd

    Width: 1.3’ to 6.56’ (400mm to 2000mm)

    Voltage: 240 or 480 VAC

    T.I.G. welding techniques

    Space bar opening: : 3/8’’ to 2’’ (1 to 60mm)

    Discharge height: 4‘ (1200mm)

    Frequency: 60 Hz

    Installation angle: 90°

    Performances

    Design

    Aqualitec Corp. - 610 W Carob Street, Compton, CA 902201-877-278-2214. Fax (323) 732 2815. www.aqualitec.com

  • 8/9/2019 AQ DS Screentec V3 Lowres

    2/8

    SCREENTEC

    Aqualitec: Keep it Simple

     VERTICAL BAR SCREEN

    Screentec:

    The Mechanical Vertical Bar Screen Solution forHeadworks, Lift Stations, Deep Wells and Manholes.

    By Aqualitec.

    Aqualitec Corp. - 610 W Carob Street, Compton, CA 902201-877-278-2214. Fax (323) 732 2815. www.aqualitec.com

  • 8/9/2019 AQ DS Screentec V3 Lowres

    3/8

    Aqualitec: Keep it Simple

    SCREENTEC VERTICAL BAR SCREEN

    Operating Mode

    The mechanical vertical bar screen Screentec can be installed in many applications includingHeadworks, Lift Stations, Deep Wells and Manholes. Due to its vertical design, Screentec can retrofitany kind of structure with minimal or no changes.

    1 The Rake, set up ona sturdy belt, movesdownward following2 guide rails on eachside of the frame.

    2 The Rake collects allthe screenings stuckby the bar screen.

    3 The Rake goes up,lifting up all thecollected screenings.

    4 Screenings areejected in a washercompactor Compactecor in a dumpster.

    Rake

    BarScreen

    3

    2

    4

    1

  • 8/9/2019 AQ DS Screentec V3 Lowres

    4/8

    Aqualitec: Keep it Simple

    SCREENTEC VERTICAL BAR SCREEN

    Features & Benefits

    With a 90° angle installation, Screentec can fitin any kind of structure, up to 50’ deep.

    Screentec does not have moving parts at thebottom of the frame. The weekly maintenancewill only consist of a visual check of the topframe. The access is safe since operators canopen the secure hood from the grate level.

    The frame of the vertical bar screen is com-pletely enclosed. Adding a washer compactorCompactec with a bagger system will maintaintotal odor control. Screentec can be installed inresidential areas without risk of odor complaints.

    1. VerticalDesign

    3. Odor Control 

    2. Minimal & Easy Maintenance

  • 8/9/2019 AQ DS Screentec V3 Lowres

    5/8

    Aqualitec: Keep it Simple

    SCREENTEC VERTICAL BAR SCREEN

    Deep Well 

    1. Mendocino, California

    Solution: With its vertical design,Screentec fits into narrow and deepstructures such as the Mendocinodeep well.

    Context: The Headwork’s structure is complex with a 12’ deep well. Inside, 2 narrow channels(1 communitor - 1 grinder) dealing with a peak flow of 1mgd.

    Top view Inside view

    Current viewDesign view

    NoStructuralChanges

  • 8/9/2019 AQ DS Screentec V3 Lowres

    6/8

    Aqualitec: Keep it Simple

    SCREENTEC VERTICAL BAR SCREEN

    Lift Station

    2. The Lower Township, New Jersey

    Context: This lift station has an inlet pipe and a manual rack. Daily maintenance is required tomanually remove the debris.

    Solution: Screentec will be installedright at the influent inlet. No structuralchanges are required and the existingmanual rack will be used as the over-flow back up.

    Top view Inside view

    Upcoming installation,

    June 2012Design view

    NoManualLabor 

  • 8/9/2019 AQ DS Screentec V3 Lowres

    7/8

    Aqualitec: Keep it Simple

    SCREENTEC VERTICAL BAR SCREEN

    Headworks

    3. City of St. John’s, Washington

    Solution: Screentec fits right into theexisting channel.

    Headworks view Headworks

    view

    Design view, Upcominginstallation, July 2012

    CollectsAll 

    Debris

    Context: The City of St John’s has to complywith the Biosolids Rule. They need to replacethe grinder by a mechanical bar screen that will

    remove all the debris from the influent.

  • 8/9/2019 AQ DS Screentec V3 Lowres

    8/8

    Aqualitec: Keep it Simple

    SCREENTEC VERTICAL BAR SCREEN

    Manhole

    4. City of Orange, France

    Solution: To protect the pumps, theonly solution was to install themechanical bar screen ahead of theirpumps.

    Screentec is installed into theirmanhole, collecting all the debrisprior to reaching the pumps.

    Top view

    Current view

    Inside view

    Context: With no screening operation, the pumps of the WasteWater Treatment Plant are clogged

    and damaged, resulting on a great deal of manual work and maintenance cost.

    ProtectsPumps