Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station...
Transcript of Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station...
![Page 1: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/1.jpg)
1www.aqualitec.comwww.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
![Page 2: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/2.jpg)
2www.aqualitec.comwww.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec Conclusion
![Page 3: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/3.jpg)
3www.aqualitec.com
Scope of work
www.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
SPACE REQUIREMENTS - FOOTPRINT
Depth: 18’
Equipment Length: 25’ – 3”
Equipment Width: 1’ –3"
Height of discharge: 3’ – 11’’
Bar spacing: ½’’
Installation angle: 90°
Weight: 1,430 lbs
HYDRAULIC CONDITIONS
Influent: Raw Municipal
Peak flow: 600,000 GPD
Maximum Design flow: 2 MGD
![Page 4: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/4.jpg)
4www.aqualitec.com
Scope of work Retrofit with minimal structural changes
www.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
![Page 5: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/5.jpg)
5www.aqualitec.com
Scope of work Retrofit with minimal structural changes
www.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
![Page 6: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/6.jpg)
6www.aqualitec.com
Scope of work No more expensive, manual and unsafe maintenance
www.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
- Remove rags, flushable wipes,towels, bed sheets…..
![Page 7: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/7.jpg)
7www.aqualitec.com
Scope of work Protects pumps from debris
www.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
![Page 8: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/8.jpg)
8www.aqualitec.comwww.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec Conclusion
![Page 9: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/9.jpg)
9www.aqualitec.com
Screentec Solution
www.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
![Page 10: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/10.jpg)
10www.aqualitec.com
Screentec Solution
Screentec, Bar Screen Solution Vertical design Integrated by pass – Lateral flanges Retrofit any structure No moving part under grade level
www.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
![Page 11: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/11.jpg)
11www.aqualitec.com
Screentec Solution
www.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
![Page 12: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/12.jpg)
12www.aqualitec.comwww.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec Conclusion
![Page 13: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/13.jpg)
Installation of Screentec
13www.aqualitec.comwww.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
![Page 14: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/14.jpg)
Installation of Screentec
14www.aqualitec.comwww.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
![Page 15: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/15.jpg)
Installation of Screentec
15www.aqualitec.comwww.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
![Page 16: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/16.jpg)
Installation of Screentec
16www.aqualitec.comwww.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
![Page 17: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/17.jpg)
Installation of Screentec
17www.aqualitec.com
Previous
Current
www.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
![Page 18: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/18.jpg)
18
WASTEWATER TREATMENT EQUIPENT
www.aqualitec.com
Significant savings with a small investment
SCREENTEC, THE PUMP STATION BAR SCREEN
Expensive labor Pumps are protected Unsafe environment (H2S) No below-grade maintenance Structural constraints No structural changes
![Page 19: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/19.jpg)
19www.aqualitec.comwww.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec Conclusion
![Page 20: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/20.jpg)
20www.aqualitec.com
Screentec allows wastewater operators to protect expensive pump equipment from non-dispersible debris.
Screentec’s versatile design fits almost any application with minimal retrofit.
Screentec’s automatic operation frees operators from costly and dangerous manual maintenance.
Screentec’s simple, versatile design makes it affordable, effective, and reliable.
Keep It Simple.
www.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
![Page 21: Screentec, Pump Station Bar Screen - Aqualitec...SCREENTEC, THE PUMP STATION BAR SCREEN Lift Station 162 – City of Pembroke Pines, FL Scope of Work Solution Installation of Screentec](https://reader036.fdocuments.us/reader036/viewer/2022062223/60fc0e98c505f5425d656082/html5/thumbnails/21.jpg)
Erwan Ouattara (310) 926-3118 [email protected]
Olivier Monfort(310) 703-2174 [email protected]
21www.aqualitec.com
Keep It Simple.
www.aqualitec.com
SCREENTEC, THE PUMP STATION BAR SCREEN
Contact Information