Transcript of Amplitec OMT User Manual
-
8/18/2019 Amplitec OMT User Manual
1/37
OMT
User Manual
-
8/18/2019 Amplitec OMT User Manual
2/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 2 ~
Content
Chapter 1 OMT Software Instruction.............................................................................................................................4
1.1 Summary...........................................................................................................4
1.2 Operation Enviroment ............................................................................................4
1.2.1 Hardware Requirement.........................................................................................................................................4
1.2.2 System Requirement.............................................................................................................................................4
1.3 OMT Monitoring Methods........................................................................................5
1.3.1 OMT Monitoring Display ....................................................................................................................................5
1.3.2 OMT Monitoring Connection...............................................................................................................................5
1.3.2.1 Local Monitoring Connection Display...........................................................................................................5
1.3.2.2 Remote Monitoring Connection Display........................................................................................................5
Chapter 2 OMT Software Operation And Application ............................................................................ ..................... 6
2.1 OMT Monitoring Connection Preparation .....................................................................6
2.1.1 Equipment Preparation.........................................................................................................................................6
2.1.2 Operation Preparation................................................................................................. ....................................... 6
2.1.3 OMT Software Installation And Login ................................................................................................................6
2.2 Create New City & Area & Equipment Information..........................................................7
2.2.1 Create New City...................................................................................................................................................7
2.2.2 Create New Area .............................................................. ................................................................ .................... 8
2.2.3 Create New Equipment ........................................................................................................................................8
2.3 Monitoring Operation Methods..................................................................................9
2.3.1 Local Connection Operation.................................................................................................................................9
2.3.2 Search Site And Search Equipment....................................................................................................................10
2.3.3 Monitoring Repeater...........................................................................................................................................14
2.3.3.1 Read / Write Basic Parameter Information...................................................................................................14
2.3.3.2 Read / Write RF Parameter Information.......................................................................................................17
2.3.3.3 Read Alarm and Read / Write Enable of Alarm Parameter Information ...................................................... 20
2.3.3.4 Resume Factory Default Setting...................................................................................................................23
2.3.4 Remote Connection Operation .................................................................. ......................................................... 24
2.3.4.1 Set Repeater“Query/setting phone number”And“Reporting number” ......................................................... 24
2.3.4.2 Set Repeater“Equipment Telephone”...........................................................................................................26
2.3.4.3 Establish Modem Remote Monitoring Communication...............................................................................27
Chapter 3 OMT Software Functions.................................................................. ........................................................... 28
-
8/18/2019 Amplitec OMT User Manual
3/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 3 ~
3.1 Functions of Sections.......................................................................................... 28
3.1.1 Equipment Management Section......................... ..................................................................... ....................... 29
3.1.2 Basic Information Section ....................................................................... ........................................................... 29
3.1.3 Equipment Monitoring Section ..........................................................................................................................30
3.1.3.1 Basic Parameter Information Page ................................................................... ............................................ 30
3.1.3.2 RF Parameter Information Page ........................................................... ........................................................ 31
3.1.3.3 Alarm Parameter Information Page.............................................................. ............................................. 31
3.1.3.4 Alarm History Page................................................................ ................................................................... 32
3.1.4 Real-time Information Feedback Section...........................................................................................................32
3.2 Create New Equipment And Management ................................................................ 32
3.2.1 Create New City.................................................................................................................................................32
3.2.2 Create New Area .................................................................. .................................................................. .........33
3.2.3 Create New Master Equipment ........................................................... ............................................................ 33
3.2.4 Create New Slave Equipment.............................................................................................................................34
3.2.5 Rename City, Area, Equipment..........................................................................................................................34
3.2.6 Edit Equipment Basic Information.....................................................................................................................35
3.2.7 Delete Equipment...............................................................................................................................................35
3.2.8 Delete Area All Repeaters..................................................................................................................................36
3.2.9 Delete City All Repeaters...................................................................................................................................36
Chapter 4 Appendix........................................................................................................................................................37
4.1 The Band Corresponding Relationship Between RF Parameters Information Page’s Control Items with
Repeater Equipments’ ................................................................................................ 37
4.2 The Band Corresponding Relationship Between Alarm Parameters Information Page’s Alarm Items
with Repeater Equipments’ .......................................................................................... 37
-
8/18/2019 Amplitec OMT User Manual
4/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 4 ~
Chapter 1 OMT Software Instruction
1 1 Summary
The software has Parameter Setting, Parameter Queries, Alarm Collection, etc. functions. i. e.
Parameter Setting include repeater serial number setting, monitoring center phone number setting, shift
frequency setting, alarm threshold settings, etc. Parameter Query not only check the setted configuration
information but also can collect real-time repeater working data. Summary, Parameter Query contributes to
the repeater site monitoring and fault diagnosis.
This software owns visual user interface, friendly interface, easy operation, stable and reliable
etc. features.
1 2 Operation Enviroment
1 2 1 Hardware Requirement
(1). PC 1 pcs ( the least requirement as follows );
CPU: Pentium III ( at least 800MHz ) or better processor
Memory: 512MB or larger The left storage of hard disk: at least 1GB
(2). RS-232 connecting cable 1 pcs
(3). GSM Modem ( 1 pcs )
(4). SIM card 2 pcs ( one to put in repeater, the other one to put in modem for receiving and sending
message )
1
2
2 System Requirement
(1). Operation system: Windows XP or higher version
(2). Display resolution rate should be 1024×768 or higher ( recommended standard: 1024×768 )
(3). Amplitec-OMT software
(4). Office 2003 or higher version
-
8/18/2019 Amplitec OMT User Manual
5/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 5 ~
1 3 OMT Monitoring Methods
1
3
1 OMT Monitoring Display
(Figure 1)
1 3 2 OMT Monitoring Connection
1
3
2
1 Local Monitoring Connection Display
(Figure 2)
1
3
2
2 Remote Monitoring Connection Display
(Figure 3)
-
8/18/2019 Amplitec OMT User Manual
6/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 6 ~
Chapter 2 OMT Software Operation And Application
2 1 OMT Monitoring Connection Preparation
2 1 1 Equipment Preparation
1. Repeater Equipment ( Including Repeaters Accessories Power Cord and RF cables )
2. One RS-232 Connection Line
3. One GSM Modem
4. Two GSM SIM Cards ( to be used in GSM Modem and repeater equipment to send and receive
message )
2 1 2 Operation Preparation
1. Set up repeater equipment and switch on the power.
2. Please connect the PC and repeater equipment by RS-232, and make sure the RS-232 cable IDECD
has been finished installation. ( for details please take RS-232 CD as reference )
2 1 3 OMT Software Installation And Login
1. The new version OMT software do not need to run the installation steps, just copy the whole folder from
the software disk to your computer.
2. Double click the icon “OMT.exe” to login the software. , main OMT interface ( show as Figure 4 ),
the code in chart stands for:
(1). Equipment Management Section
(2). Basic Information Section
(3). Equipment Monitoring Section
(4). Real-time Information Feedback Section
-
8/18/2019 Amplitec OMT User Manual
7/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 7 ~
(Figure 4: OMT Interface)
2 2 Create New City & Area & Equipment Information
Note: When you login OMT Equipment Management Interface, and the repeater equipment you want to
mornitor was existed ( for example Figure 5: MasterEquipment0 and SlaveEquipment1 ), then it is no need
to go through bellow 2.2 procedure and get into 2.3 process directly.
(Figure 5)
2 2 1 Create New City
1. After login, users can see software main interface ( Equipment Management Section ) on the left side,
right click mouse, there will show a list menu. ( Figure 6 )
2. Left click “New City” to create a monitoring city name.
-
8/18/2019 Amplitec OMT User Manual
8/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 8 ~
(Figure 6)
2 2 2 Create New Area
1. Right click the mouse which point to New City, there will show a list menu. ( Figure 7 )
2. Left click “New Area” to create a monitoring area name.
(Figure 7)
2 2 3 Create New Equipment
1. Right click the mouse which point to New Area, there will show a list menu. ( Figure 8 )
(Figure 8)
2. Left click “New Equipment” to create a monitoring repeater. Fill in the basic information of the monitoring
repeater then click OK to achieve. ( Figure 9 )
-
8/18/2019 Amplitec OMT User Manual
9/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 9 ~
(Figure 9)
2 3 Monitoring Operation Methods
2
3
1 Local Connection Operation
Before to start bellow local mornitoring connection, it is appreciated that the users make sure two points:
(1)Make sure that the repeaters have been set up and it is power on and it can work normally.
(2)Make sure that the PC and repeater equipment is connected by RS-232.
Please follow bellow operation procedures:
1. Left click the first column “Communication Link” on top left corner as Figure 10:
(Figure 10)
2. On “Communication type” please select “Local serial port”, then on “Current Port” please select the
corresponding COM port which is connected to the repeater equipment by RS-232. ( Figure 11 )
3. Click “Connect”, if the selection of the correct COM port, the red light will turn to green color. ( Figure 11 )
-
8/18/2019 Amplitec OMT User Manual
10/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 10 ~
(Figure 11)
2 3 2 Search Site And Search Equipment
Note: When it is first time to proceed the real-time mornitoring communication connection for the new
created equipment, it is appreciated that to proceed “Search Site” and “Search Equipment” frist, just in
order to make sure that OMT and equipment can be identified and match each other in intellectualization.
1. Select the corresponding repeater equipment on the left side ( Equipment Management Section ) as
Figure 12:
(Figure 12)
2. In Equipment Monitoring Information Section please select “Basic Parameter Information”, left click the
button “Search Site” on the right lower side. ( Figure 13 )
-
8/18/2019 Amplitec OMT User Manual
11/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 11 ~
(Figure 13)
3. Get the detail information of site number and equipment number which repeater currently connected.
( Figure 14 )
(Figure 14)
4. Please select the corresponding repeater equipment on the left side ( Equipment Management Section )
and right click it, the equipment management function manu will appear. ( Figure 15 )
(Figure 15)
5. Left click “Edit Equipment”, you will see the equipment basic information input box as shown in figure 16
on the left side.
(Figure 16)
6. Change the site number and equipment number in the dialogue box brought out and ensure that the two
groups of the number are completely match with the numbers as third step you’ve got. And then click ok.
( As shown in figure 16 on the right side. )
7. Select the corresponding repeater equipment on the left side ( Equipment Management Section ) as
Figure 17:
-
8/18/2019 Amplitec OMT User Manual
12/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 12 ~
(Figure 17)
8. In Equipment Monitoring Information Section please select “Basic Parameter Information”, left click the
button “Search Site” on the right lower side. ( Figure 18 )
(Figure 18)
9. Get the detail information which equipment connected, including city , region and the name of
equipment ,the number of site, and the number of equipment etc. ( As shown in figure 19 on the left side. )
And find the corresponding equipment in the main interface of the software shown on the left side.
( Equipment Management Section ) ( As shown in figure 19 on the right side. )
(Figure 19)
-
8/18/2019 Amplitec OMT User Manual
13/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 13 ~
10. Select the corresponding repeater equipment on the left side ( Equipment Management Section ) as
Figure 20:
(Figure 20)
11. In Equipment Monitoring Information Section please select “Basic Parameter Information”, left click the
button “Search Equipment” on the right lower side. ( Figure 21 )
(Figure 21)
12. Please wait for seconds and pay attention on feedback section on the right downward inferior, the
“Transmit” and “Receive” information of the repeater equipment will appear.
13. When it appears “Update the equipment parameters is successful!”, means OMT search equipment
procedure and identified in intellectualization successfully, then please go on next step. ( Figure 22 )
(Figure 22)
-
8/18/2019 Amplitec OMT User Manual
14/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 14 ~
2 3 3 Monitoring Repeater
2
3
3
1 Read / Write Basic Parameter Information
Read Basic Parameter Information
1. Please select the corresponding repeater equipment on the left side. ( Equipment Management Section )
( Figure 23 )
(Figure 23)
2. Enter “Basic Parameter Information“ page, pick the items you need to check. ( Figure 24 )
(Figure 24)
3. Click “Read“ button and pay attention on the feedback section on the right downward inferior, there will
be “Transmit“ and “Receive“ message of the repeaters going on the feedback section. ( Figure 25 )
-
8/18/2019 Amplitec OMT User Manual
15/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 15 ~
(Figure 25)
4. When communication is successful, the updated information will immediately appear to the “Status”
column as bellow charge. ( Figure 26 )
(Figure 26)
Write Basic Parameter Information
1. Please select the corresponding repeater equipment on the left side. ( Equipment Management Section )
( Figure 27 )
(Figure 27)
2. Enter “Basic Parameter Information“ page, pick the items you need to set, input the correct basic
parameters on the corresponding “Setting” column. ( For example as bellow Figure 28, to set parameters
“Query/setting phone number1~5” and “Reporting number” as “13800138000”. )
-
8/18/2019 Amplitec OMT User Manual
16/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 16 ~
(Figure 28)
3. Click “Write“ button and pay attention on the feedback section on the right downward inferior, there will
be “Transmit“ and “Receive“ message of the repeaters going on the feedback section. ( Figure 29 )
(Figure 29)4. When communication is successful, the updated information will immediately appear to the “Status”
column as Figure 30.
(Figure 30)
-
8/18/2019 Amplitec OMT User Manual
17/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 17 ~
2 3 3 2 Read / Write RF Parameter Information
Note: Please refer to the appendix contents in the end of the text for the band corresponding relationship
between RF parameters information page's control items with repeater equipments'.
Read RF Parameter Information
1. Please select the corresponding repeater equipment on the left side. ( Equipment Management Section )
( Figure 31 )
(Figure 31)
2. Enter “RF Parameter Information“ page, pick the items you need to check. ( Figure 32 )
(Figure 32)
3. Click “Read“ button and pay attention on the feedback section on the right downward inferior, there will
be “Transmit“ and “Receive“ message of the repeaters going on the feedback section. ( Figure 33 )
(Figure 33)
-
8/18/2019 Amplitec OMT User Manual
18/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 18 ~
4. When communication is successful, the updated information will immediately appear to the “Status”
column as bellow charge. ( Figure 34 )
(Figure 34)
Write RF Parameter Information
1. Please select the corresponding repeater equipment on the left side. ( Equipment Management Section )
( Figure 35 )
(Figure 35)
2. Enter “RF Parameter Information“ page, pick the items you need to set, input the correct RF parameters
on the corresponding “Setting” column. ( Figure 36 )
-
8/18/2019 Amplitec OMT User Manual
19/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 19 ~
(Figure 36)
3. Click “Write“ button and pay attention on the feedback section on the right downward inferior, there will
be “Transmit“ and “Receive“ message of the repeaters going on the feedback section. ( Figure 37 )
(Figure 37)4. When communication is successful, the updated information will immediately appear on the “Status”
column as Figure 38.
(Figure 38)
-
8/18/2019 Amplitec OMT User Manual
20/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 20 ~
2 3 3 3 Read Alarm and Read / Write Enable of Alarm Parameter Information
Note: Please refer to the appendix contents in the end of the text for the band corresponding relationship
between alarm parameters basic information page's alarm items with repeater equipments'.
Read Alarm and Enablement of Alarm Parameter Information
1. Please select the corresponding repeater equipment on the left side. ( Equipment Management Section )
( Figure 39 )
(Figure 39)
2. Enter “Alarm Parameter Information“ page, pick the items you need to check. ( Figure 40 )
(Figure 40)
3. Click “Read“ button and pay attention on the feedback section on the right downward inferior, there will
be “Transmit“ and “Receive“ message of the repeaters going on the feedback section. ( Figure 41 )
(Figure 41)
-
8/18/2019 Amplitec OMT User Manual
21/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 21 ~
4. When communication is successful, the updated information will immediately appear to the “Status” and
“Enable” column as Figure 42.
(Figure 42)
Write Enablement of Alarm Parameter Information
1. Please select the corresponding repeater equipment on the left side. ( Equipment Management Section )
( Figure 43 )
(Figure 43)
2. Enter “Alarm Parameter Information“ page, pick the items you need to set, input the correct enable of
alarm parameters on the corresponding “Setting” column. ( Figure 44 )
-
8/18/2019 Amplitec OMT User Manual
22/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 22 ~
(Figure 44)
3. Click “Write(Enable)“ button and pay attention on the feedback section on the right downward inferior,
there will be “Transmit“ and “Receive“ message of the repeaters going on the feedback section. ( Figure
45 )
(Figure 45)
4. When communication is successful, the updated information will immediately appear to the “Enable”
column as Figure 46.
(Figure 46)
-
8/18/2019 Amplitec OMT User Manual
23/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 23 ~
2 3 3 4 Resume Factory Default Setting
When the users need to resume factory default setting, please go on bellow procedures ( Note: When the
repeaters are resumed factory default setting, all the parameters which were set before will be resumed to
initial status. If the users do not need to resume factory default setting, please forget this step. )
1. Please select the corresponding repeater equipment on the left side. ( Equipment Management Section )
( Figure 47 )
(Figure 47)
2. Enter “Basic Parameter Information“ page, pick the items you need. ( Figure 48 )
(Figure 48)
3. Click “Default Equipment” button and pay attention on the feedback section on the right downward
inferior, there will be “Transmit“ and “Receive“ message of the repeaters going on the feedback section.
4. When it appears “Default the repeater is successful!”, resume factory default setting sucessfully, please
go on next step. ( Figure 49 )
-
8/18/2019 Amplitec OMT User Manual
24/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 24 ~
(Figure 49)
2 3 4 Remote Connection Operation
2
3
4
1 Set Repeater“ Query/setting phone number”And“ Reporting number”
1. Power on the repeater and marke sure PC and repeaters are connected by RS-232.
2. Left click the first column “Communication Link” on top left corner as Figure 50:
(Figure 50)
3. Select “Local serial port” on “Communication type”, then please select the corresponding COM port
which is connected to the repeater equipment by RS-232 on “Current Port”. ( Figure 51 )
4. Click “Connect” button, if the selection of the correct COM port is successful, the red light will turn to
green color. ( Figure 51 )
(Figure 51)
5. Please select the corresponding repeater equipment on the left side. ( Equipment Management Section )
( Figure 52 )
-
8/18/2019 Amplitec OMT User Manual
25/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 25 ~
(Figure 52)
6. Enter “Basic Parameter Information” page, pick item “Query/setting phone number” and “Reporting
number”, set modem SIM card numbers which will be connected to PC in “Set Value” column. ( Figure 53 )
(Figure 53)
7. Click “Write“ button and pay attention on the feedback section on the right downward inferior, there will
be “Transmit“ and “Receive“ message of the repeaters going on the feedback section. ( Figure 54 )
(Figure 54)
8. When communication is successful, the updated information will immediately appear on the “Status”
column as Figure 55.
-
8/18/2019 Amplitec OMT User Manual
26/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 26 ~
(Figure 55)
2 3 4 2 Set Repeater“ Equipment Telephone”
1. Please select the corresponding repeater equipment on the left side ( Equipment Management Section )
and right click it, the equipment management function manu will appear. ( Figure 56 )
(Figure 56)
2. Left click “Edit Equipment”, you will see the equipment basic information input box as Figure 57.
-
8/18/2019 Amplitec OMT User Manual
27/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 27 ~
(Figure 57)
3. Input the SIM card number which was inserted into the repeaters, click “OK” button.
2
3
4
3 Establish Modem Remote Monitoring Communication
1. Pull out the RS-232 cable which was connected to the repeater, replace it by a modem. In the same time
please make sure that the modem antenna and power cord is in correct connections, and make sure the
repeater after power on it can work normally. ( Also it is appreciated to make sure the modem antenna has
been installed in the repeater and fasten closely. )
2. Left click the first column “Communication Link” on top left corner as Figure 58:
(Figure 58)
3. Select “GSM Short message” on “Communication type”, then please select the corresponding COM port
which is connected to modem by RS-232 on “Current Port”. ( Figure 59 )
4. Click “Connect” button, if the selection of the correct COM port is successful, the red light will turn to
green color. ( Figure 59 )
-
8/18/2019 Amplitec OMT User Manual
28/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 28 ~
(Figure 59)
5. After the establishment of remote monitoring communication sucessful, users can start to proceed the
remote monitoring. ( Detailed monitoring operation procedures please take 2.3.3 above as reference. )
Chapter 3 OMT Software Functions
3 1 Functions of Sections
(Figure 60: OMT Interface)
OMT software screen includes the following section as chart above, the number stands for dfifferent
information sections.
-
8/18/2019 Amplitec OMT User Manual
29/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 29 ~
Section 1: Equipment Management Section
Section 2: Basic Information Section
Section 3: Equipment Monitoring Section
Section 4: Real-time Information Feedback Section
3
1
1 Equipment Management Section
Section One: Equipment Management Section. It is devided different layers from up to down ( Figure 61 )
City→ Area→Main Equipment→Slave Equipment.
(Figure 61)
3 1 2 Basic Information Section
Section Two: Basic Information Section. This section is the basic information of master equipment and
slave equipment. Shown on ( Figure 62 ), each equipment includes below basic information:
Equipment belonging city
Equipment belonging area
Equipment name
Equipment current state ( Normal / Alarm )
Equipment site number
Equipment number
Equipment SIM number
Equipment installation location
-
8/18/2019 Amplitec OMT User Manual
30/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 30 ~
(Figure 62)
3 1 3 Equipment Monitor ing Section
Section Three: Equipment Monitoring Section. This section includes Basic Parameter Information page, RF
Parameter Information page, Alarm Parameter Information page, Alarm History page ( 4 pages in total,
shown below ). Each repeater monitoring functions can be operated here. ( Figure 63 )
(Figure 63)
3 1 3 1 Basic Parameter Information Page
To show the repeater basic information, it can be set maually. Mean while it can show the update time.
( Figure 64 )
(Figure 64)
-
8/18/2019 Amplitec OMT User Manual
31/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 31 ~
3 1 3 2 RF Parameter Information Page
To show the repeater’s RF parameters and working status, i.e. PA switch on and off, attenuantion value,
channel state, etc. Meanwhile it can show the update time. ( Figure 65 )
(Figure 65)
3 1 3 3 Alarm Parameter Information Page
Alert page is the feedback from the repeater, to let user knows any faults timely. And to show or to write all
enable alarm parameters. ( Figure 66 )
-
8/18/2019 Amplitec OMT User Manual
32/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 32 ~
(Figure 66)
3 1 3 4 Alarm History Page
When there is an alarm occurs ( includes arlarm happens and eliminates ), it will show all of the alarm
status. ( Figure 67 )
(Figure 67)
3 1 4 Real-time Information Feedback Section
Section Four: Real-time Information Feedback Section. This section shows the repeater’s real time
communication data and OMT operation state. Users could pay attention to this section to know the
feedback from the repeater. ( Figure 68 )
(Figure 68)
3 2 Create New Equipment And Management
3 2 1 Create New City
1. Right click on the left side ( Equipment Management Section ), the equipment management functional
manu will appear. ( Figure 69 )
2. Select “New City” and click it to create a new city. ( Figure 69 )
(Figure 69)
-
8/18/2019 Amplitec OMT User Manual
33/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 33 ~
3 2 2 Create New Area
1. Right click “New City ”, there will show a list manu. ( Figure 70 )
2. Select “New Area” and click it to create a new area. ( Figure 70 )
(Figure 70)
3 2 3 Create New Master Equipment
1. Right click “New Area”, there will show a list manu. ( Figure 71 )
(Figure 71)
2. Select “New Equipment” and the equipment information box will appear. ( Figure 72 )
3. Fill in the master equipment basic information which you are going to create. Then click “ OK”, the
creation is successful. ( Figure 72 )
(Figure 72)
-
8/18/2019 Amplitec OMT User Manual
34/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 34 ~
3 2 4 Create New Slave Equipment
1. Right click “MasterEquipment0 ”, there will show a list manu. ( Figure 73 )
(Figure 73)
2. Select “New Slave Equipment” and the equipment information box will appear. ( Figure 74 )
3. Fill in the slave equipment basic information which you are going to create. Then click “ OK”, the creation
is successful. ( Figure 74 )
(Figure 74)
3 2 5 Rename City, Area, Equipment
Users can rename city , area and equipment at any time, please follow bellow procedures to go on:
1. Left click the item you want to modify.
2. Left click one more time again, the edited box will appear ( for example “ New City 0” ).
3. Fill in the new name you want, “Enter” on the keyboard then finished.
-
8/18/2019 Amplitec OMT User Manual
35/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 35 ~
(Figure 75)
3 2 6 Edit Equipment Basic Information
Sometimes there is necessary to edit repeater basic information, i.e. change SIM card of the repeater, in
this situation, the original equipment information have to be changed.
Please go on following steps:
1. Please select the corresponding repeater equipment on the left side ( Equipment Management Section ),
right click it ( Figure 76 SlaveEquipment1 as bellow ), the equipment managemet manu will appear.
(Figure 76)
2. Left click “Edit Equipment”, the equipment basic information box will appear. ( Figure 77 )
(Figure 77)3. Fill in the new information of the repeater then click OK.
3 2 7 Delete Equipment
1. Right click the corresponding repeater equipment on the left side. ( Equipment Management Section )
( Figure 78 SlaveEquipment1 )
-
8/18/2019 Amplitec OMT User Manual
36/37
Operation and Maintenance Terminal (OMT) Users Manaual
~ Page 36 ~
(Figure 78)
2. Click “Delete” and this step can be successful.
3 2 8 Delete Area All Repeaters
1. Right click “New Area ”. ( Figure 79 )
(Figure 79)
2. Click “Delete” and all repeaters can be deleted.
3 2 9 Delete City All Repeaters
1. Right click “New City ”. ( Figure 80 )
(Figure 80)
2. Click “Delete” and all repeaters can be deleted.
-
8/18/2019 Amplitec OMT User Manual
37/37
Operation and Maintenance Terminal (OMT) Users Manaual
Chapter 4 Appendix
4 1 The Band Corresponding Relationship Between RF Parameters Information
Page’s Contro l Items with Repeater Equipments ’
Example: For “W37T-GW” as Figure 81.
(Figure 81)
4
2 The Band Corresponding Relationship Between Alarm Parameters
Information Page’s Alarm Items with Repeater Equipments’
Example: For “W37T-GW” as Figure 82.