Actix DV for Agilent 2.1 Release Notes
Transcript of Actix DV for Agilent 2.1 Release Notes
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
1/20
Release Not es
Actix DV for Agilent 2.1
November 2004
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
2/20
Release Notes
Copyright Actix 2004 Page 2
Contents
1 ACTIX DV FOR AGILENT OVERVIEW ...................................3
2 SYSTEM REQUIREMENTS ....................................................5
RECOMMENDED SYSTEM CONFIGURATION .........................................................5MINIMUM SYSTEM CONFIGURATION ...................................................................6
3 WHATS NEW IN 2.1? .........................................................7
HANDSET,SCANNER, AND DATA SUPPORT ........................................................7SUPPORT FOR AGILENT E6474(NITRO)RELEASE 8...........................................8
EV-DODATA SUPPORT...................................................................................8EDGEDATA SUPPORT....................................................................................9REPLAY PANEL .............................................................................................10DATA VIEWS .................................................................................................11ADDITIONAL FLEXIBILITY ................................................................................16ENHANCED WAMSSUPPORT ........................................................................18FIXES AND ENHANCEMENTS ...........................................................................18
4 KNOWN ISSUES ...............................................................19
GENERAL......................................................................................................19ACTIX SHORTCUTS ........................................................................................19
CHARTS........................................................................................................19CONSOLE .....................................................................................................20EVENT NAVIGATOR........................................................................................20PROTOCOL STACK BROWSER.........................................................................20REPORTS .....................................................................................................20WORKSPACES...............................................................................................20
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
3/20
Release Notes
Copyright Actix 2004 Page 3
1 Actix DV for Agilent OverviewActix DV for Agilent is an advanced software solution that
enables fast, accurate visualization and analysis of
information collected by drive test equipment. Engineers
tasked with performing localized diagnostics andoptimization on GSM, GPRS, EDGE, UMTS CDMA2000
and EV-DO wireless networks are empowered to achieve
their goals through a carefully designed user interface andpowerful underlying data analysis technology.
Detailed knowledge of drive test equipment and the
environment in which it is used has enabled the design of a
solution that will exceed expectations and significantly
improve productivity. User-controlled software viewsenable all of the appropriate information to be displayed on
screen in easy-to-read tables, charts and maps that have
been tailored for this application. Built-in features such asprotocol stack browsing and drill-down enable specific
events to be diagnosed in detail within the same intuitive
user environment, whilst a range of standardized reportspresent useful KPIs and other measurements for multiple
days of data.
Actix DV for Agilent features a unique event navigator
view which displays a timeline of the events recorded in the
drive test data. Forwards and backwards "replay" of thelogfile enables instant identification and analysis of key
events within the file without the need for sequential
analysis. This feature alone can significantly enhance theuser's ability to quickly identify and solve particular
problems, often within minutes of the drive test beingcompleted.
Actix and Agilent have worked together to deliver this
solution based upon ActixVision, a powerful and flexibledata processing and statistical analysis engine which is at
the heart of all Actix solutions. Using advanced software
technology and industry knowledge developed over many
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
4/20
Release Notes
Copyright Actix 2004 Page 4
years and fully proven in the field, ActixVision supportsincoming data streams from all network technologies, and
provides the software application layer with key analysis
facilities such as KPI extraction through event-aware
processing and multi-dimensional querying and binning.This technology, coupled with Agilents industry expertise,
has produced a market leading solution for the visualization
and diagnosis of network performance information.
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
5/20
Release Notes
Copyright Actix 2004 Page 5
2 System requirementsThis section defines the recommended and minimum
system requirements for successfully running Actix DV for
Agilent.
If you install DV on a system that does not meet the
recommended configuration requirements, you mayexperience the following limitations:
You may be unable to process large amounts of
data.
You may experience delays when trying to
perform certain tasks.
You may not be able to take advantage of somemapping capabilities.
DVs advanced correlation and analysis
capabilities may not perform as desired.
Recommended system configuration
Processor (CPU) Pentium III 700-MHz or higher.
Operating System Microsoft Windows XP.
Memory (RAM) 512 Megabytes.
Available Hard Disk Space 15 Gigabytes (about 80MB
for DV; most of this space is for drive test data files, map
information, and virtual memory needs).
Note A paging file size of at least 1 GB isrecommended on Windows 2000 and NT
systems. You can set the paging file sizeby modifying the System properties from
the Windows Control Panel.
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
6/20
Release Notes
Copyright Actix 2004 Page 6
Minimum system configuration
Processor (CPU) Pentium II 333-MHz or higher.
Operating System Microsoft Windows 98 (or later)operating system, Microsoft Windows NT Workstation
operating system version 4.0 Service Pack 3 or later,
Microsoft Windows 2000 Professional or later operating
system.
Memory (RAM) 128 Megabytes.
Available Hard Disk Space 1 Gigabyte (for DV, drivetest data files, map information, and virtual memory needs).
Note A paging file size of at least 1 GB isrecommended on Windows 2000 and NT
systems. You can set the paging file size
by modifying the System properties from
the Windows Control Panel.
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
7/20
Release Notes
Copyright Actix 2004 Page 7
3 Whats new in 2.1?Handset, Scanner, and Data Support
DV automatically correlates devices for you, allowing
quick multiple source visualization and analysis.
If a single instance of a handset, scanner, and/or data deviceexists in a datafile, DV assumes that these should be
correlated.
If multiple instances of any device type exist in a datafile,
DV will rely on user-defined labels that can be added in the
E6474 (Nitro) software.
Identical labels should be used on all devices that require
correlation. Correlated devices will show up as a singleitem in the console view (see below).
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
8/20
Release Notes
Copyright Actix 2004 Page 8
Support for Agilent E6474 (Nitro) Release 8
This release provides support for Nitro EV-DO and EDGEdrive test data.
EV-DO Data Support
DV 2.1 supports EV-DO Data application collected from
Nitro by bundling reports, measurement windows andcharts.
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
9/20
Release Notes
Copyright Actix 2004 Page 9
EDGE Data Support
DV 2.1 also supports EDGE Data application collectedfrom Nitro by bundling reports, measurement windows and
charts.
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
10/20
Release Notes
Copyright Actix 2004 Page 10
Replay Panel
The Replay panel is used to control the playback of the logfile, starting from the beginning of the file and displaying
the data message by message, either one message per click
of the inner buttons or playing through the messages usingthe outer buttons, at a speed set using the sliding control.
This allows variable-speed, bi-directional playback, and
can also be used to step single messages.
PropertiesReplay Speed
Replay panel
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
11/20
Release Notes
Copyright Actix 2004 Page 11
Data Views
These views or 'forms' provide many different ways ofexamining aspects of data for a particular technology, and
are provided in a pre-defined arrangement in a DV
workspace.
Many data views have been added for this release, and thissection lists all data views provided (each technology also
offers one or more Event Navigator views):
GPRS
GPRS Data Session This form provides a snapshot of
important data parameters for both received and transmitted
packets.
GPRS Data Timeslots This form provides a quick and
easy view of time slot usage on the uplink and downlink.
GPRS Throughput This chart provides a time-seriesview of downlink throughput for several protocol layers.
GPRS Composite Measurement Chart This chartprovides a time-series view of multiple measurements that
signature the behavior of GPRS network.
GSM
GSM Current Channel This form provides a summary
of important serving channel and serving cell radio
parameters, including BCCH frequency, TCH frequency,Hopping Frequencies, Current TS, MAIO, HSN, Speech
Codec.
GSM Measurement Chart This chart provides a time-
series view of RxLevSub and RxQualSub. The verticalblack bar denotes the currently selected message.
GSM Neighbor Chart This chart provides an ordered
view of the signal levels of both serving and neighbor cells.
BCCH and BSIC are available in the tool-tip.
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
12/20
Release Notes
Copyright Actix 2004 Page 12
GSM Radio Parameters This form provides a quicklook at important radio parameters including RxLev,
RxQual, Transmit Power, Timing Advance and FER.
GSM Serving + Neighbors This form provides a list ofserving and neighbor cells along with the corresponding
ARFCN, BSIC and RxLev.
EDGE
EGPRS BEP Chart This form provides trend of BEP at
different modulation scheme as well as a detail view ofRMAC layer KPI.
EGPRS Current Channel - This form provides asummary of important serving channel and serving cell
radio parameters, including BCCH frequency, TCH
frequency, Hopping Frequencies, Current TS, MAIO, HSN.
EGPRS Data Session This form provides summary viewof each data session
EGPRS Uplink/Downlink Analysis Chart This chartprovides a time-series view of multiple measurements that
signature the behavior of EDGE supported network.
EGPRS Status This is a detail view of multiple key
EDGE parameters such as BEP, Coding Scheme, WindowSize, etc.
EGPRS Summary This is a summary view of EDGEKPI including RLC, LLC, SNDCP, Application
Throughput, Data Retransmission, RMAC Metrics, etc.
EGPRS Throughput Chart This form provides a time-series view of Uplink and Downlink RLC/LLC
Throughput.
UMTS Voice
UMTS Active NBor Sets Chart This chart shows a
snapshot of the SC's in the Active and Monitored sets, and
their signal levels at a particular instance in time.
UMTS Active NBor Sets Time Chart This chart shows
a time series of Ec/Io of Active and Monitored setmeasurements.
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
13/20
Release Notes
Copyright Actix 2004 Page 13
UMTS Active NBor Sets RSCP Time Chart This chartshows a time series of RSCP of Active and Monitored set
measurements.
UMTS Measurement Charts This chart shows a timeseries view of coverage parameters during the drive route.
UMTS Radio Parameters This form shows the
measurements from the Active and Monitored sets with thecorresponding mobile transmit power and average
downlink transport channel Block Error Rate.
UMTS Measurement Control Summary This form
shows the measurements retrieved from RRC layers
measurement control summary of both uplink anddownlink.
UMTS Neighbor List This form reports the current
neighbor list.
UMTS Scanner Charts This chart shows the signal
levels from the Top N scrambling codes read by the
scanner.
UMTS Pilot Pollution Chart This chart best works with
UMTS voice event navigator. It indicates the possiblepollutants in the event of pilot pollution.
UMTS Data
UMTS Composite Measurement Windows (UL/DL) These are charts in time series showing RRC throughput in
parallel with other related measurements for both Uplink
and downlink.
UMTS RLC Statistics Measurement This window
provides measurements for some of the key performance
indicator collected in the RLC layer.
UMTS Task Summary This is a summary view of
measurement collected from Nitro Data Testing Device.
CDMA 1X
CDMA Handset Summary Information This form
gives handset information such as MIN, channel, protocolin use. The serving site is also called out.
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
14/20
Release Notes
Copyright Actix 2004 Page 14
CDMA RLP Statistics This form shows uplink anddownlink RLP statistics such as frame counts and erasures.
Charts of uplink and downlink RLP cumulative throughput
are also show.
CDMA Radio Link Measurements This chart shows
time-series views of FER, transmit power, receive power,and aggregate Ec/Io.
CDMA Radio Link Summary This form shows handset
information, a summary of radio link statistics, and a chart
showing EcIo values for each measured finger.
CDMA Code Domain Power by Walsh Code This form
shows the measurement uniquely collected Nitro CodeDomain Power. Chart view measurements in the order of
the PN.
CDAM Code Domain Power by Lowest Channel This
form shows the measurement uniquely collected Nitro
Code Domain Power. Chart view measurements are pre-sorted by Channel.
CDMA Code Domain Statistics This measurement
window provides a detail view of multiple Code Domain
Attributes.
CDMA Composite Measurement Chart This chartshows a time series of several key CDMA RLP layermeasurements
CDMA Task Summary This is a summary view of
measurement collected from Nitro Data Testing Device
CDMA Pilot Pollution Chart This chart best works with
CDMA voice event navigator. It indicates the possiblepollutants in the event of pilot pollution.
EV-DOEVDO Pilot Measurement This is a graphical viewshowing Ec/Io of Active Set, Candidate Set, and Neighbor
Set of measured pilots.
EVDO Forward Rate Statistics (Traffic Channel) This
form offers a detail breakdown of Good/Bad CRC received
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
15/20
Release Notes
Copyright Actix 2004 Page 15
of each traffic channel. It is also accompanied with RLCthroughput chart.
EVDO Forward Rate Statistics (Control Channel)
This form offers a detail breakdown of Good/Bad CRCreceived of each control channel. It is also accompanied
with RLC throughput chart.
EVDO Handset Power Measurement This windowprovides handset power information such as open/close
loop transmit power, AGC Power, and total transmit power.
EVDO Reverse Traffic Statistics The form provides a
distribution of usage in reverse traffic channels.
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
16/20
Release Notes
Copyright Actix 2004 Page 16
Additional Flexibility
DV 2.1 provides much more flexibility for users tovisualize data in different ways:
Configurable Table
Configurable Chart
Attribute Picker
Attribute Picker
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
17/20
Release Notes
Copyright Actix 2004 Page 17
Filter for controlling the data displayed in eachdata window:
Filter
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
18/20
Release Notes
Copyright Actix 2004 Page 18
Enhanced WAMS Support
DV 2.1 provides a seamless method for automergingWAMS data set and RF data from the handset. This allows
users to correlate between WAMS data and trace data.
DV 2.1 now also supports MMS and WAP Test.
Fixes and Enhancements Fixed UMTS handset name in Console View.
Included UMTS Pilot Pollution and Missing
Neighbor Rx information.
Included CDMA Pilot Pollution and MissingNeighbor Rx information.
Enhanced UMTS MultiRAT support.
Enhanced mapping functionalities.
Enhanced replay tool.
General file loading and memory-usage
performance improvement.
GSM Rx Lev
WAMS Data
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
19/20
Release Notes
Copyright Actix 2004 Page 19
4 Known IssuesGeneral
Actix DV automatically synchronizes CDMA
handset and PN Scanner measurements that weremade on the same frequency at the same time.
When the handset is in idle mode, DV mayincorrectly determine the handsets frequencyand, as a result, synchronize incorrectly with PN
Scanner measurements during these times.
Matching cellref data is required to properly show
the handoff state in UMTS data.
Downlink TFI information for Nitro 8 filescaptured using a Nokia 6230 handset is not
displayed, as the information is not available in
the .sd5 file the RMAC messaging containingthe DL TFI information from the Nokia 6230 is
not captured by Nitro 8 and thus not visible in
DV.
Actix shortcuts Some Actix shortcuts are not removed from the
Windows Start menu on an upgrade.
Charts The Chart's Attributes icon does not respond to
changes to the Toolbar size. When changing the
Preferences option to deselect "Use SmallToolbars", the chart Attributes icon does not
change at all. It should update with text as with all
other toolbar icons.
-
8/3/2019 Actix DV for Agilent 2.1 Release Notes
20/20
Release Notes
C i h A i 2004 P 20
Console The console defaults to showing details on the last
stream loaded rather than the defaulting to the
first. No console report will show up for data devices
and scanners that are not correlated to handsets.
Event Navigator Data views that are docked do not open properly
when saved in a workspace, but appearcompressed to the left. To correct the view,
simply refresh the window.
Protocol Stack Browser All the Layer 3 protocol messages are displayed
as UPLINK.
Reports The FTP GET report also shows FTP PUT results
and vice versa. Rx Power should be part of CDMA Radio Link
Distribution window.
The WAMS tests should be separated becausethey have measurement names in common, and it
is not possible to identify which WAMS test the
measurement refers to.
Workspaces Workspaces saved in DV2.0 do not open properly
in DV2.1. The map is empty and it is not possibleto add any further attributes. Also, the console
report says 'page cannot be found'. There is an
extra stream in the stream selector pane.