HUAWEI BSC6000
Fault Management
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
2/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page2
Foreword
The article describes concepts related to alarms of
HUAWEI BSC6000 and mechanism of reporting alarms,
and introduces common operation functions of alarm
management with respect to alarm operation &maintenance and alarm box operation & maintenance
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
3/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page3
References
HUAWEI BSC6000 Base Station Controller LMT User
Guide
HUAWEI BSC6000 Base Station Controller Routine
Maintenance Guide
Online Help
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
4/36Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page4
Objectives
Upon completion of this course, you will be able to:
get familiar with basic concepts of BSC6000 alarms
understand the mechanism of implementing BSC6000 alarms
get familiar with common operations of BSC6000 alarm
management
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
5/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page5
Contents
Basic Concepts
Alarm Operation
Alarm Transfer Tool
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
6/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page6
Alarm Classification
According to the generation time, alarms are classified into: Active alarm: An active alarm is a fault alarm not recovered in
the BSC6000 system
History alarm: A history alarm is an alarm generated in the
BSC6000 system
History alarms consist of the following:
Fault alarms recovered
Fault alarms not recovered
Event alarms
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
7/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page7
Alarm Classification
According to the alarm nature, alarms are classified into:
Fault alarm: A fault alarm is an alarm that is reported to the
network management equipment when equipment has faults or
exceptions. After the faults or exceptions are processed and
cleared, the alarm is cleared
Event alarm: An event alarm is a alarm generated to indicate a
transient state during equipment operation. Some event alarms
are generated periodically. Event alarms are only to notify that
the system is in alarm state and thus do not require handling
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
8/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page8
Basic Concepts of Alarms
Alarm serial number: The alarm serial number is arranged
on the basis of alarm raised time. The alarm serial
number is the only index in the alarm logs. The alarm
generated and the alarm cleared use the same alarmserial number
Alarm name: The alarm name has a one-to-one mapping
with the alarm ID
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
9/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page9
Basic Concepts of Alarms
Alarm raised time
Recovery time
Alarm ID: An alarm ID defines a type of alarms and
represents a specific type of faults or events. Alarm ID
is the only index of alarm item, and is the main
keyword of the alarm configuration table in the network
management system
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
10/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page10
Basic Concepts
Alarmseverity
Definition Handling method
Critical Alarms that affect the services provided by thesystem
Critical alarms must be handled immediately evenif they are generated outside working hours. If the
equipment or resources are totally unavailable, theequipment or resources have to be recovered.
Handle the alarms immediately.
Otherwise, the system may be unavailable.
Major Alarms that affect the quality of service
Major alarms must be handled during workinghours. If the quality of services provided by certainequipment or resources decreases, the equipmentor resources need to be recovered.
Handle the alarms in time.
Otherwise, some major functions may be affected.
Minor Alarms that do not affect the quality of services butmay lead to more serious faults
Minor alarms need handling in proper time orfurther check.
Check the alarm causes and
eliminate them.
Warning Alarms indicating that there may be faults affectingthe quality of services
Learn the running status ofthe system
Alarm severity: Critical Alarm, Major Alarm, Minor Alarm, Warning Alarm
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
11/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page11
Basic Concepts
Classification of network management: The network managementis divided into power system, environment system, signaling system,
trunk system, hardware system, software system, operating system,
communication system, quality of services, processing faults, and so
on
Location information:Location information is the information used to locate
alarms. The location information in the alarm recovery report is the same as that
in the corresponding fault alarm report
Alarm type: Fault alarm or event alarm
Alarm Clear Flag: The sign indicates whether an alarm is cleared.
The Flag is either not cleared or cleared
Shield Flag: The Shield Flag shields the alarm information not required
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
12/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page12
Basic Concepts
To Alarm Box Flag: To Alarm Box Flag controls the alarm
reporting to the alarm box
Synchronization Serial Number: The synchronization serial
number is arranged on the basis of the sending time of thealarm report. The synchronization serial number ranges
from one to 0x7ffffffe (hexadecimal) in a cyclical order
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
13/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page13
Connection of Alarm Box Connection scheme: Through the serial port, the alarm box is
connected to the LMT client
When an alarm is reported, LMT uses the Convert program to drive
the alarm box to generate an audible and visual alarm
The operator uses the LMT alarm console to control the alarm box,
for example, stopping the alarm sound and the alarm indictor
Alarm management
module
GBAM
Alarm
Box
Convert
LMT client
Alarm
Box
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
14/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page14
Channel to Report Alarms of Local Subrack
Process of reporting alarms of the local subrack:
SMU generates alarms
After being screened and filtered on SMU, alarms are switched through GE and
reported to GBAM
GBAM reports alarms to LMT/EMS and records the alarm log
The Convert module of LMT drives and output the alarm box
GMPS
Service
boardGSCU
GBAMLMT
Convert
Alarm
box
GEPS
GSCUService
board
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
15/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page15
Channel to Report Alarms of Remote Subrack
Process of reporting alarms of remote subrack: The remote subrack SMU generates alarms
Alarms are screened and filtered on SMU
Alarms are switched through GE to the GEIUT of the local subrack, and then
sent through SS7 link of the Ater interface to the GEIUT board of the central
subrack
The GEIUT board of the local subrack switches alarms through GE and
reports to GBAM
GBAM finishes corresponding output (send the output to LMT/EMS and
records the alarm log)
The Covert module of LMT finishes driving and output of the alarm boxGMPS
GEIUT GSCUGBAM
LMT
Convert
Alarm
box
GTCS
Service
boardGEIUT
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
16/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page16
Channel to Report BTS Alarms Process of reporting BTS alarms:
Alarms generated at BTS are screened and filtered inside the BTS
Alarms are sent through OML links and sent to EIUB of the local subrack.
Alarms are processed through LAPD protocol on the EIUB, switched
through GE, and sent to GBAM
GBAM finishes the alarm output (reports alarms to LMT/EMS and recordsthe alarm log)
The Convert module of LMT finishes driving and output of the alarm box
GMPS
GEIUB GSCU GBAMLMT
Convert
Alarm
box
GEPS
GEIUB GSCU
BTS
BTS
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
17/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page17
Contents
Basic Concepts
Alarm Operation
Alarm Transfer Tool
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
18/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page18
Operations About Alarms
Management operations of alarms are as follows:
Browsing Alarms
Querying History Alarms
Querying Alarm Box Information
Controlling the Alarm Box
Maintaining the Shield Severity of the Alarm Box
Querying Alarm Configuration Setting Alarm Display Color
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
19/36
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
20/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page20
Querying History Alarms Query history alarms. There are two tab pages of setting
conditions for history alarms:
General Option
Detailed Option
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
21/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page21
Querying History Alarms After setting the conditions for querying history alarms, click OK to
display the query interface
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
22/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page22
Querying History Alarms
Right click the selected alarm, and in the short-cut menu, make
the following operations:
Choose Query History Alarm to query history alarms again
Choose Save All Alarms to save query results of all history
alarms
Choose Save Selected Alarms to save query results of selected
history alarms
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
23/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page23
Querying History Alarms
Choose Alarm Details to display the interface of detailedinformation of selected alarms
Choose Set Show Columns to set the alarm information to be
displayed
Choose Filter Alarms to set alarm filtering conditions so that
selected alarms can be displayed
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
24/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page24
Querying Alarm Box Information Querying Alarm Box Information: Query the detailed
information of alarms in the local host or GBAM
Choose Alarm > Query Alarm Box Information. The Alarm
Box Alarm dialog box is displayed. (Demonstrate)
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
25/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page25
Querying Alarm Box Information
The following operations can be made according to demands:
Choose Save All Alarms to save all the queried alarm box
information
Choose Save Selected Alarms to save the selected alarm box
information Choose Set Show Columns to set the alarm information to be
displayed
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
26/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page26
Querying Alarm Box Information The following operations can be made according to
demands:
Choose Alarm Details to display detailed content of selected
alarm box information
Choose Filter Alarms to display the Filter Alarm Condition
dialog box. Set the alarm filtering conditions, and the alarm
information is displayed according to the filtering conditions
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
27/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page27
Controlling Alarm Box Controlling Alarm Box: The function is used to reset the
alarm box, turn off the alarm indicator, and stop the alarm
sound
Choose Alarm > Control Alarm Box to display the Alarm
Box Control dialog box
M i t i i th Shi ld S it f th Al
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
28/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page28
Maintaining the Shield Severity of the Alarm
Box Maintaining the Shield Severity of the Alarm Box: The
function is used to query and set the shield severity of the
alarm box
Choose Alarm > Maintain Alarm Box Shield Severity to
display the Maintain Alarm Box Shield Severity dialog box
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
29/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page29
Querying Alarm Configuration Querying alarm configuration: The function is used to query Alarm ID,
Alarm Name, Alarm Type, Alarm Severity, Shield Flag, To Alarm Box
Flag, and Modification Flag. (Only super user can query Modification
Flag.)
Choose Alarm > Query Alarm Configuration to display the Query
Alarm Configuration Settings dialog box
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
30/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page30
Querying Alarm Configuration Right-click the alarm to be queried
In the short-cut menu, make the following operations:
Choose Query Alarm Configuration to query alarm configuration
again
Choose Set To Alarm Box Flag to set To Alarm Box Flag,
including Report and Not report
Choose Restore Alarm Configuration to restore the default
settings of the selected alarm
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
31/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page31
Setting Alarm Display Color Setting alarm display color: The function is used to set the
display colors of different kinds of alarms. Without settings,
the system default colors are used
Choose Alarm > Set Alarm Display Color to display the Set
Alarm Display Color dialog box
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
32/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page32
Contents
Basic Concepts
Alarm Operation
Alarm Transfer Tool
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
33/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page33
Alarm Forwarding Tool Environment required for the usage:
The serial interface cable of the alarm box is connected to the
serial interface of PC
Menu path
Start > All Programs > Huawei Local Maintenance Terminal >
LMT Version > Alarm Forward Tool
Icon in the task bar
Normal
Disconnected
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
34/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page34
Configuring Connection of Alarm Forwarding Tool
Double click the icon in the task bar The configuration dialog box is displayed to show the current
situation of message forwarding
Menu path to the configuration
Operate > Configure Configure parameters
IP of the host port
= GBAM IP
Serial port = the number of the serial port through which PC is connected to the
alarm box
-
7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0
35/36
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page35
Summary
The lecture introduces the following information aboutHUAWEI BSC6000.
Basic concepts of alarms
Process of reporting alarms
Common operations of managing alarms
-