    Foreword

    The article describes concepts related to alarms of

    HUAWEI BSC6000 and mechanism of reporting alarms,

    and introduces common operation functions of alarm

    management with respect to alarm operation &maintenance and alarm box operation & maintenance

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    3/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page3

    References

    HUAWEI BSC6000 Base Station Controller LMT User

    Guide

    HUAWEI BSC6000 Base Station Controller Routine

    Maintenance Guide

    Online Help

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    4/36Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page4

    Objectives

    Upon completion of this course, you will be able to:

    get familiar with basic concepts of BSC6000 alarms

    understand the mechanism of implementing BSC6000 alarms

    get familiar with common operations of BSC6000 alarm

    management

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    5/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page5

    Contents

    Basic Concepts

    Alarm Operation

    Alarm Transfer Tool

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    6/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page6

    Alarm Classification

    According to the generation time, alarms are classified into: Active alarm: An active alarm is a fault alarm not recovered in

    the BSC6000 system

    History alarm: A history alarm is an alarm generated in the

    BSC6000 system

    History alarms consist of the following:

    Fault alarms recovered

    Fault alarms not recovered

    Event alarms

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    7/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page7

    Alarm Classification

    According to the alarm nature, alarms are classified into:

    Fault alarm: A fault alarm is an alarm that is reported to the

    network management equipment when equipment has faults or

    exceptions. After the faults or exceptions are processed and

    cleared, the alarm is cleared

    Event alarm: An event alarm is a alarm generated to indicate a

    transient state during equipment operation. Some event alarms

    are generated periodically. Event alarms are only to notify that

    the system is in alarm state and thus do not require handling

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    8/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page8

    Basic Concepts of Alarms

    Alarm serial number: The alarm serial number is arranged

    on the basis of alarm raised time. The alarm serial

    number is the only index in the alarm logs. The alarm

    generated and the alarm cleared use the same alarmserial number

    Alarm name: The alarm name has a one-to-one mapping

    with the alarm ID

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    9/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page9

    Basic Concepts of Alarms

    Alarm raised time

    Recovery time

    Alarm ID: An alarm ID defines a type of alarms and

    represents a specific type of faults or events. Alarm ID

    is the only index of alarm item, and is the main

    keyword of the alarm configuration table in the network

    management system

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    10/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page10

    Basic Concepts

    Alarmseverity

    Definition Handling method

    Critical Alarms that affect the services provided by thesystem

    Critical alarms must be handled immediately evenif they are generated outside working hours. If the

    equipment or resources are totally unavailable, theequipment or resources have to be recovered.

    Handle the alarms immediately.

    Otherwise, the system may be unavailable.

    Major Alarms that affect the quality of service

    Major alarms must be handled during workinghours. If the quality of services provided by certainequipment or resources decreases, the equipmentor resources need to be recovered.

    Handle the alarms in time.

    Otherwise, some major functions may be affected.

    Minor Alarms that do not affect the quality of services butmay lead to more serious faults

    Minor alarms need handling in proper time orfurther check.

    Check the alarm causes and

    eliminate them.

    Warning Alarms indicating that there may be faults affectingthe quality of services

    Learn the running status ofthe system

    Alarm severity: Critical Alarm, Major Alarm, Minor Alarm, Warning Alarm

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    11/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page11

    Basic Concepts

    Classification of network management: The network managementis divided into power system, environment system, signaling system,

    trunk system, hardware system, software system, operating system,

    communication system, quality of services, processing faults, and so

    on

    Location information:Location information is the information used to locate

    alarms. The location information in the alarm recovery report is the same as that

    in the corresponding fault alarm report

    Alarm type: Fault alarm or event alarm

    Alarm Clear Flag: The sign indicates whether an alarm is cleared.

    The Flag is either not cleared or cleared

    Shield Flag: The Shield Flag shields the alarm information not required

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    12/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page12

    Basic Concepts

    To Alarm Box Flag: To Alarm Box Flag controls the alarm

    reporting to the alarm box

    Synchronization Serial Number: The synchronization serial

    number is arranged on the basis of the sending time of thealarm report. The synchronization serial number ranges

    from one to 0x7ffffffe (hexadecimal) in a cyclical order

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    13/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page13

    Connection of Alarm Box Connection scheme: Through the serial port, the alarm box is

    connected to the LMT client

    When an alarm is reported, LMT uses the Convert program to drive

    the alarm box to generate an audible and visual alarm

    The operator uses the LMT alarm console to control the alarm box,

    for example, stopping the alarm sound and the alarm indictor

    Alarm management

    module

    GBAM

    Alarm

    Box

    Convert

    LMT client

    Alarm

    Box

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    14/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page14

    Channel to Report Alarms of Local Subrack

    Process of reporting alarms of the local subrack:

    SMU generates alarms

    After being screened and filtered on SMU, alarms are switched through GE and

    reported to GBAM

    GBAM reports alarms to LMT/EMS and records the alarm log

    The Convert module of LMT drives and output the alarm box

    GMPS

    Service

    boardGSCU

    GBAMLMT

    Convert

    Alarm

    box

    GEPS

    GSCUService

    board

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    15/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page15

    Channel to Report Alarms of Remote Subrack

    Process of reporting alarms of remote subrack: The remote subrack SMU generates alarms

    Alarms are screened and filtered on SMU

    Alarms are switched through GE to the GEIUT of the local subrack, and then

    sent through SS7 link of the Ater interface to the GEIUT board of the central

    subrack

    The GEIUT board of the local subrack switches alarms through GE and

    reports to GBAM

    GBAM finishes corresponding output (send the output to LMT/EMS and

    records the alarm log)

    The Covert module of LMT finishes driving and output of the alarm boxGMPS

    GEIUT GSCUGBAM

    LMT

    Convert

    Alarm

    box

    GTCS

    Service

    boardGEIUT

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    16/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page16

    Channel to Report BTS Alarms Process of reporting BTS alarms:

    Alarms generated at BTS are screened and filtered inside the BTS

    Alarms are sent through OML links and sent to EIUB of the local subrack.

    Alarms are processed through LAPD protocol on the EIUB, switched

    through GE, and sent to GBAM

    GBAM finishes the alarm output (reports alarms to LMT/EMS and recordsthe alarm log)

    The Convert module of LMT finishes driving and output of the alarm box

    GMPS

    GEIUB GSCU GBAMLMT

    Convert

    Alarm

    box

    GEPS

    GEIUB GSCU

    BTS

    BTS

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    17/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page17

    Contents

    Basic Concepts

    Alarm Operation

    Alarm Transfer Tool

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    18/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page18

    Operations About Alarms

    Management operations of alarms are as follows:

    Browsing Alarms

    Querying History Alarms

    Querying Alarm Box Information

    Controlling the Alarm Box

    Maintaining the Shield Severity of the Alarm Box

    Querying Alarm Configuration Setting Alarm Display Color

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    19/36

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    20/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page20

    Querying History Alarms Query history alarms. There are two tab pages of setting

    conditions for history alarms:

    General Option

    Detailed Option

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    21/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page21

    Querying History Alarms After setting the conditions for querying history alarms, click OK to

    display the query interface

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    22/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page22

    Querying History Alarms

    Right click the selected alarm, and in the short-cut menu, make

    the following operations:

    Choose Query History Alarm to query history alarms again

    Choose Save All Alarms to save query results of all history

    alarms

    Choose Save Selected Alarms to save query results of selected

    history alarms

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    23/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page23

    Querying History Alarms

    Choose Alarm Details to display the interface of detailedinformation of selected alarms

    Choose Set Show Columns to set the alarm information to be

    displayed

    Choose Filter Alarms to set alarm filtering conditions so that

    selected alarms can be displayed

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    24/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page24

    Querying Alarm Box Information Querying Alarm Box Information: Query the detailed

    information of alarms in the local host or GBAM

    Choose Alarm > Query Alarm Box Information. The Alarm

    Box Alarm dialog box is displayed. (Demonstrate)

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    25/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page25

    Querying Alarm Box Information

    The following operations can be made according to demands:

    Choose Save All Alarms to save all the queried alarm box

    information

    Choose Save Selected Alarms to save the selected alarm box

    information Choose Set Show Columns to set the alarm information to be

    displayed

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    26/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page26

    Querying Alarm Box Information The following operations can be made according to

    demands:

    Choose Alarm Details to display detailed content of selected

    alarm box information

    Choose Filter Alarms to display the Filter Alarm Condition

    dialog box. Set the alarm filtering conditions, and the alarm

    information is displayed according to the filtering conditions

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    27/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page27

    Controlling Alarm Box Controlling Alarm Box: The function is used to reset the

    alarm box, turn off the alarm indicator, and stop the alarm

    sound

    Choose Alarm > Control Alarm Box to display the Alarm

    Box Control dialog box

    M i t i i th Shi ld S it f th Al

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    28/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page28

    Maintaining the Shield Severity of the Alarm

    Box Maintaining the Shield Severity of the Alarm Box: The

    function is used to query and set the shield severity of the

    alarm box

    Choose Alarm > Maintain Alarm Box Shield Severity to

    display the Maintain Alarm Box Shield Severity dialog box

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    29/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page29

    Querying Alarm Configuration Querying alarm configuration: The function is used to query Alarm ID,

    Alarm Name, Alarm Type, Alarm Severity, Shield Flag, To Alarm Box

    Flag, and Modification Flag. (Only super user can query Modification

    Flag.)

    Choose Alarm > Query Alarm Configuration to display the Query

    Alarm Configuration Settings dialog box

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    30/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page30

    Querying Alarm Configuration Right-click the alarm to be queried

    In the short-cut menu, make the following operations:

    Choose Query Alarm Configuration to query alarm configuration

    again

    Choose Set To Alarm Box Flag to set To Alarm Box Flag,

    including Report and Not report

    Choose Restore Alarm Configuration to restore the default

    settings of the selected alarm

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    31/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page31

    Setting Alarm Display Color Setting alarm display color: The function is used to set the

    display colors of different kinds of alarms. Without settings,

    the system default colors are used

    Choose Alarm > Set Alarm Display Color to display the Set

    Alarm Display Color dialog box

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    32/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page32

    Contents

    Basic Concepts

    Alarm Operation

    Alarm Transfer Tool

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    33/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page33

    Alarm Forwarding Tool Environment required for the usage:

    The serial interface cable of the alarm box is connected to the

    serial interface of PC

    Menu path

    Start > All Programs > Huawei Local Maintenance Terminal >

    LMT Version > Alarm Forward Tool

    Icon in the task bar

    Normal

    Disconnected

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    34/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page34

    Configuring Connection of Alarm Forwarding Tool

    Double click the icon in the task bar The configuration dialog box is displayed to show the current

    situation of message forwarding

    Menu path to the configuration

    Operate > Configure Configure parameters

    IP of the host port

    = GBAM IP

    Serial port = the number of the serial port through which PC is connected to the

    alarm box

  • 7/30/2019 05_omd606200 Huawei Bsc6000 Fault Management Issue1.0

    35/36

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page35

    Summary

    The lecture introduces the following information aboutHUAWEI BSC6000.

    Basic concepts of alarms

    Process of reporting alarms

    Common operations of managing alarms