The article describes concepts related

to alarms of HUAWEI BSC6000 and

mechanism of reporting alarms, and

introduces common operation functions

of alarm management with respect to

alarm operation & maintenance and

alarm box operation & maintenance

Page 3: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 3HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

References

HUAWEI BSC6000 Base Station

Controller LMT User Guide

HUAWEI BSC6000 Base Station

Controller Routine Maintenance Guide

Online Help

Page 4: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 4HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Upon completion of this course, you will

be able to:

get familiar with basic concepts of

BSC6000 alarms

understand the mechanism of

implementing BSC6000 alarms

get familiar with common

operations of BSC6000 alarm

management

Page 5: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 5HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Chapter 1 Basic ConceptsChapter 1 Basic Concepts

Chapter 2 Alarm OperationChapter 2 Alarm Operation

Chapter 3 Alarm Transfer ToolChapter 3 Alarm Transfer Tool

Page 6: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 6HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Alarm Classification

According to the generation time, alarms are classified into:

Active alarm: An active alarm is a fault alarm not recovered in the BSC6000 system

History alarm: A history alarm is an alarm generated in the BSC6000 system

History alarms consist of the following:

Fault alarms recovered

Fault alarms not recovered

Event alarms

According to the alarm nature, alarms are classified into:

Fault alarm: A fault alarm is an alarm that is reported to the network management equipment when equipment has faults or exceptions. After the faults or exceptions are processed and cleared, the alarm is cleared

Page 7: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 7HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Alarm Classification

Event alarm: An event alarm is a alarm generated to

indicate a transient state during equipment operation. Some

event alarms are generated periodically. Event alarms are

only to notify that the system is in alarm state and thus do

not require handling

Page 8: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 8HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Basic Concepts of Alarms

Alarm serial number: The

alarm serial number is

arranged on the basis of

alarm raised time. The alarm

serial number is the only

index in the alarm logs. The

alarm generated and the

alarm cleared use the same

alarm serial number

Alarm name: The alarm name

has a one-to-one mapping

with the alarm ID

Page 9: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 9HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Basic Concepts of Alarms

Alarm raised time

Recovery time

Alarm ID: An alarm ID defines a type of alarms and

represents a specific type of faults or events. Alarm ID

is the only index of alarm item, and is the main

keyword of the alarm configuration table in the

network management system

Page 10: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 10HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Basic Concepts Alarm severity: Critical Alarm, Major Alarm, Minor Alarm, Warning Alarm

Alarm severity

Definition Handling method

Critical Alarms that affect the services provided by the system

Critical alarms must be handled immediately even if they are generated outside working hours. If the equipment or resources are totally unavailable, the equipment or resources have to be recovered.

Handle the alarms immediately.

Otherwise, the system may be

unavailable.

Major Alarms that affect the quality of service

Major alarms must be handled during working hours. If the quality of services provided by certain equipment or resources decreases, the equipment or resources need to be recovered.

Handle the alarms in time.

Otherwise, some major functions may be affected.

Minor Alarms that do not affect the quality of services but may lead to more serious faults

Minor alarms need handling in proper time or further check.

Check the alarm causes and

eliminate them.

Warning Alarms indicating that there may be

faults affecting the quality of services

Learn the running status of the

system

Page 11: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 11HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Basic Concepts Classification of network management: The network management

is divided into power system, environment system, signaling

system, trunk system, hardware system, software system,

operating system, communication system, quality of services,

processing faults, and so on

Location information: Location information is the information used to

locate alarms. The location information in the alarm recovery report is the

same as that in the corresponding fault alarm report

Alarm type: Fault alarm or event alarm

Alarm Clear Flag: The sign indicates whether an alarm is cleared.

The Flag is either “not cleared” or “cleared”

Shield Flag: The Shield Flag shields the alarm information not required

Page 12: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 12HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

To Alarm Box Flag: To Alarm Box Flag controls the alarm

reporting to the alarm box

Synchronization Serial Number: The synchronization serial

number is arranged on the basis of the sending time of the

alarm report. The synchronization serial number ranges

from one to 0x7ffffffe (hexadecimal) in a cyclical order

Basic Concepts

Page 13: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 13HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Connection of Alarm Box

Connection scheme: Through the serial port, the alarm box is

connected to the LMT client

When an alarm is reported, LMT uses the Convert program to drive

the alarm box to generate an audible and visual alarm

The operator uses the LMT alarm console to control the alarm box,

for example, stopping the alarm sound and the alarm indictor

Alarm management module

GBAM

Alarm Box

Convert

LMT client

Alarm Box

Page 14: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 14HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Channel to Report Alarms of Local Subrack

Process of reporting alarms of the local subrack:

SMU generates alarms

After being screened and filtered on SMU, alarms are switched through GE and reported to GBAM

GBAM reports alarms to LMT/EMS and records the alarm log

The Convert module of LMT drives and output the alarm box

GMPS

Serviceboard

GSCU GBAMLMT

ConvertAlarm

box

GEPS

GSCUServiceboard

Page 15: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 15HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Channel to Report Alarms of Remote Subrack Process of reporting alarms of remote subrack:

The remote subrack SMU generates alarms

Alarms are screened and filtered on SMU

Alarms are switched through GE to the GEIUT of the local subrack, and

then sent through SS7 link of the Ater interface to the GEIUT board of the

central subrack

The GEIUT board of the local subrack switches alarms through GE and

reports to GBAM

GBAM finishes corresponding output (send the output to LMT/EMS and

records the alarm log)

The Covert module of LMT finishes driving and output of the alarm box

GMPS

GEIUT GSCU GBAMLMT

ConvertAlarmbox

GTCS

Serviceboard GEIUT

Page 16: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 16HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Channel to Report BTS Alarms Process of reporting BTS alarms:

Alarms generated at BTS are screened and filtered inside the BTS

Alarms are sent through OML links and sent to EIUB of the local subrack. Alarms are processed through LAPD protocol on the EIUB, switched through GE, and sent to GBAM

GBAM finishes the alarm output (reports alarms to LMT/EMS and records the alarm log)

The Convert module of LMT finishes driving and output of the alarm box

GMPS

GEIUB GSCU GBAMLMT

ConvertAlarmbox

GEPS

GEIUB GSCU

BTS

BTS

Page 17: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 17HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Chapter 1 Basic ConceptsChapter 1 Basic Concepts

Chapter 2 Alarm OperationChapter 2 Alarm Operation

Chapter 3 Alarm Transfer ToolChapter 3 Alarm Transfer Tool

Page 18: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 18HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Operations About Alarms

Management operations of alarms are as follows:

Browsing Alarms

Querying History Alarms

Querying Alarm Box Information

Controlling the Alarm Box

Maintaining the Shield Severity of the Alarm Box

Querying Alarm Configuration

Setting Alarm Display Color

Page 19: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 19HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Browsing Alarms Browsing Alarms: Query active alarms and receive real-time alarm

reports to keep the displayed active alarms corresponding with GBAM. In addition, alarms can be manually cleared. (Demonstrate)

Page 20: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 20HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Querying History Alarms

Query history alarms. There are two tab pages of setting conditions for history alarms:

General Option

Detailed Option

Page 21: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 21HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Querying History Alarms

After setting the conditions for querying history alarms, click OK to display

the query interface

Page 22: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 22HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Querying History Alarms Right click the selected alarm, and in the short-cut menu, make the

following operations:

Choose Query History Alarm to query history alarms again

Choose Save All Alarms to save query results of all history alarms

Choose Save Selected Alarms to save query results of selected history alarms

Page 23: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 23HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Choose Alarm Details to display the interface of detailed

information of selected alarms

Choose Set Show Columns to set the alarm information to

be displayed

Choose Filter Alarms to set alarm filtering conditions so that

selected alarms can be displayed

Querying History Alarms

Page 24: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 24HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Querying Alarm Box Information

Querying Alarm Box Information: Query the detailed

information of alarms in the local host or GBAM

Choose Alarm > Query Alarm Box Information. The Alarm Box

Alarm dialog box is displayed. (Demonstrate)

Page 25: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 25HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

The following operations can be made according to demands:

Choose Save All Alarms to save all the queried alarm box

information

Choose Save Selected Alarms to save the selected alarm

box information

Choose Set Show Columns to set the alarm information to

be displayed

Querying Alarm Box Information

Page 26: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 26HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

The following operations can be made according to demands:

Choose Alarm Details to display detailed content of selected

alarm box information

Choose Filter Alarms to display the Filter Alarm Condition dialog

box. Set the alarm filtering conditions, and the alarm information is

displayed according to the filtering conditions

Querying Alarm Box Information

Page 27: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 27HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Controlling Alarm Box

Controlling Alarm Box: The function is used to reset the alarm

box, turn off the alarm indicator, and stop the alarm sound

Choose Alarm > Control Alarm Box to display the Alarm Box

Control dialog box

Page 28: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 28HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Maintaining the Shield Severity of the Alarm Box

Maintaining the Shield Severity of the Alarm Box: The function is

used to query and set the shield severity of the alarm box

Choose Alarm > Maintain Alarm Box Shield Severity to display

the Maintain Alarm Box Shield Severity dialog box

Page 29: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 29HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Querying Alarm Configuration

Querying alarm configuration: The function is used to query

Alarm ID, Alarm Name, Alarm Type, Alarm Severity, Shield

Flag, To Alarm Box Flag, and Modification Flag. (Only super

user can query Modification Flag.)

Choose Alarm > Query Alarm Configuration to display the

Query Alarm Configuration Settings dialog box

Page 30: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 30HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Querying Alarm Configuration Right-click the alarm to be queried

In the short-cut menu, make the following operations:

Choose Query Alarm Configuration to query alarm configuration again

Choose Set To Alarm Box Flag to set To Alarm Box Flag, including Report and Not report

Choose Restore Alarm Configuration to restore the default settings of the selected alarm

Page 31: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 31HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Setting Alarm Display Color

Setting alarm display color: The function is used to set the

display colors of different kinds of alarms. Without

settings, the system default colors are used

Choose Alarm > Set Alarm Display Color to display the Set

Alarm Display Color dialog box

Page 32: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 32HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Chapter 1 Basic ConceptsChapter 1 Basic Concepts

Chapter 2 Alarm OperationChapter 2 Alarm Operation

Chapter 3 Alarm Transfer ToolChapter 3 Alarm Transfer Tool

Page 33: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 33HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Alarm Forwarding Tool

Environment required for the usage:

The serial interface cable of the alarm box is connected to

the serial interface of PC

Menu path

Start > All Programs > Huawei Local Maintenance

Terminal > LMT Version > Alarm Forward Tool

Icon in the task bar

Normal

Disconnected

Page 34: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 34HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Configuring Connection of Alarm Forwarding Tool

Double click the icon in the task bar

The configuration dialog box is displayed to show the current situation of message forwarding

Menu path to the configuration

Operate > Configure

Configure parameters

IP of the host port

▪ = GBAM IP

Serial port

▪ = the number of the serial port through which PC is connected to the alarm box

Page 35: 12 Omd606200 Huawei Bsc6000 Fault Management Issue1.0

Page 35HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Summary

The lecture introduces the following information

about HUAWEI BSC6000.

Basic concepts of alarms

Process of reporting alarms

Common operations of managing alarms