IPACGuide

Wiring and Cloud Programming

Page 2: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

2

Thank you for purchasing a LiftMaster IPAC system. LiftMaster strongly recommends setting up and confi guring any IPACs and door controllers prior to the day of installation.

TABLE OF CONTENTS

Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

How do I login? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Wiring Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Add IPAC Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Connect Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Connect Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Add IPAC Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10

Create a New Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Add Doors/Gates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Confi gure a Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Wire Door #1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Wire Door #2 (If applicable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Create a Directory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Confi gure IPAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-17

Set Group Privileges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Bulk Load Cards/Transmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Create Credentialed User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21

Create a Resident . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Create a Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Set a Notifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25

Create a New Senior Administrator . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

(OVERVIEW IMAGE HERE)(O(O(O(O(O(O((OOOOOOOOOOO(OOOO((OO(O(OOO(OOOOO(O(O(O(O((((((((((((((((((((((((((((( VEVEVEVEVEVEVEEEEVEVEVEVEEVEVEVVEEEVEEEEVEVEEVVVVVVVVEVEEVEVEVEVEEVEVEVVVVVVVEEVEEEEEEVEEVEEEVVVVVVVVVVVEVEEVEEEEEEEERVRVRVRVRVRRVRRVRVVVVVVVVRVVVVRVVVVVRVRVVVVRVRRRRRRRVVVVVRVVRVRVVRVRVVVRVRVVVRRRRRRRRRRRRVVRVRVVVVVVRVRVRVRVRVRVVRRRRRVRVVVRVVVVRVVRVVVVRVRVVRRRRRRVVVVVRVRVRRRRRRRRRRVRVRRRRRR IEIEIEIEIEEEEEEEEEEEIIEIEIEEEEEEIEEEIEIIIEIEIEIEEEEEEIEEEEIEEIEEEEEIIEEEEEEEEEIEIIEEEEEIEIEI WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWW IMMIMIMMMMMMMMIMMMMMMMMIMMIMMMMMMMMMMIIIIMMMMMMIMIMMMMMMMMMMMMMIIMMIMMMMMIMIMMMMIMMMMMMIIIMMMIMMMMIMIMIMIMMMMMIMMIMIMMMMMMMIMMIMIMIMMIMMIMMIIMAGAGAGAGAGAGGGAGGGGGGAGGAGAGGGAGGGAGGAGAGAAAAAGAGGAGGGAGGGAGAGGAGGGGAAAAAAAAAAAAAGGGAGGGGGGGGAGAGAAAAAAGAGAGGAGGGGAGGAGGGAAAAAAAAAAGGGGGGGGGAGAGGAGAGAAAAAAAAAAAAGAGAAAAAAAAAGA EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE HEHEHEHEHHEHEHEHEEEHEEHEEEHEEEEHHHEHHHHEEEEHEHEHEHEEHEHHHHHEHHHHHEHEHEHEEEEEEHEHEEHHHHHHHHHHHHHHEEEHEHEEEHEEEHEEHEEHHHHHHHHHHHEEEHEEHEHEHEHEHEHEHEHEHHHHHHHHHHHHHHEHHHHHHEHEEHEEHEHEEHEEEHHHHHHEEHEEHHHEEEEEHHHEHHHHEEEHHHHHEHEEHHHEHHHHH RERERERERERERR ))))))

Page 3: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

3

Introduction

Order IPAC and/or door controller (SKU: IPACIPDCC)

Setup LiftMaster Hosted Services Account

Call LiftMaster Customer support at (800) 323-2276 and have credit card and primary account holder information

ready.

NOTE: Record the Administrator ID and you will receive an email to set up a permanent password.

IPAC and IPACIPDCC require an active Internet connection at the installation location (including Cat-5 or Cat-6

at the IPAC installation location).

Multiple connection options:

• High speed Internet

• DSL

Map of facility indicating entrance(s) and exit(s).

Use a map to plan out all entrances and exits to be controlled. Plan wire runs and installation points prior to

getting started.

NOTE: Before installing the IPAC and Door Controller, power on and set up the hardware at your offi ce or shop.

Follow this manual to confi gure the hardware and ensure proper functionality prior to installation. This requires

access to an Internet connection.

1

BEFORE YOU BEGIN:

2

3

4

Page 4: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

4

Cloud Login

Open a web browser and type LiftMaster.com/IPAC into the address bar.

Enter login information you were provided

in “Before you get started”. NOTE: ID and

Password are case sensitive.

Click “Log In”.

HOW DO I LOGIN?

1

2

3

4

Scroll down and click “Cloud Login”.

LiftMaster.com/IPAC

Page 5: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

5

Wiring Overview

Not responsible for conflicts between the information listed in the wiring diagram and the requirements of your local building codes. The information is for suggested use ONLY. Check your local codes BEFORE installation.

Chasis abierto Open Enclosure

COM LINK -> A B

N.C.

COM

SHLD

N.O.

RELA

Y 1

N.C.

COM

SHLD

N.O.

AU

X 1

N.C.

COM

SHLD

N.O.

RELA

Y 2

N.C.

COM

SHLD

N.O.

AU

X 2

INP

UT 1

REX

2

INP

UT 2

SH

LD

CO

M

SEN

SE

SH

LD

CO

M

SEN

SE

SH

LD

CO

M

SEN

SE

GN

D

SH

IELD

LED

-GR

N

BU

Z

HO

LD

LED

-RED

D0

D1

12V

GN

D

SH

LD

LED

-GR

N

BU

Z

HO

LD

LED

-RED

D0

D1

12V

READER 1

CO

MM

LIN

K M

OD

ULE

RELAY BOARD

READER 2

USB - Device

PE

RIP

HE

RA

LB

OA

RD

CO

NFIG

LA

N

US

B -

AD

MIN

REX 1

SENSE

COM

SHLD

1 2 3

4 5 6

7 8 9

0 #

O NO

N1

2

3

4

CO

NFIG

O NO

N1 2 3

4

POWER

PERIPHERAL BOARD

RELAY 1

Gate/Door Operator, Maglock,

or Door Strike.

AUX 1

Alarm, Light, or Camera

Common

ACCESS POINT 1

ACCESS POINT 1

ACCESS POINT 2

ACCESS POINT 2

N.O.

Common

N.O.

Common

N.O.

Sen

se

Com

mon

Sen

se

Com

mon

Sen

se

Com

mon

INPUT 1 -

Door Sensing

Device for

access point 1

READER 1 -

Passport Receiver

Model PPWR

(factory installed)

READER 2 - Wiegand Device input for access point 2

INPUT 2 - Door Sensing Device for access point 2

REX 1 - Postal Lock,

Exit Request Button

(REX), Keyswitch, Passive

Infrared Device (PIR)

for access point 1

REX 2 - Exit Request Button (REX), Keyswitch, Passive Infrared Device (PIR)

for access point 2.

ETHERNET PORT

CONFIG Common

Config Switches

Sense

RELAY 2

Gate/Door Operator,

Maglock, or Door Strike

AUX 2

Alarm, Light, or Camera

Common

N.O.

Optional KeypadRELAY BOARD

RELAY BOARD

PERIPHERAL BOARD

Page 6: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

6

USB - Device

PER

IPH

ER

AL

BO

AR

D

CO

NFIG

LA

N

US

B -

AD

MIN

REX 1

SENSE

COM

SHLDO NO

N1 2 3

4

CO

NFIG

O NO

N1 2 3

4

IPPNL

MAC 00:00:00:00:00:00

CP# TEC–3K–YYYYL

IPPNL

MAC 00:00:00:00:00:00

CP# TEC–3K–YYYYL

CO

NFIG

O NO

N1

2

3

4

Unpack IPAC and set it on a clean surface. Open IPAC using the included Key.

Setup

ADD IPAC PANEL

1

2

3 Write down Control Panel number:

TEC – _ _ – _ _ _ _ _.

Close the door.

Move #1 dipswitch to “ON”

position to enter administration

mode.

PERIPHERAL BOARD

Page 7: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

7

COM LINK -> A B

N.C.

COM

SHLD

N.O.

RELA

Y 1

N.C.

COM

SHLD

N.O.

AU

X 1

N.C.

COM

SHLD

N.O.

RELA

Y 2

N.C.

COM

SHLD

N.O.

AU

X 2

INP

UT 1

REX

2

INP

UT 2

SH

LD

CO

M

SEN

SE

SH

LD

CO

M

SEN

SE

SH

LD

CO

M

SEN

SE

GN

D

SH

IELD

LED

-GR

N

BU

Z

HO

LD

LED

-RED

D0

D1

12V

GN

D

SH

LD

LED

-GR

N

BU

Z

HO

LD

LED

-RED

D0

D1

12V

READER 1

CO

MM

LIN

K M

OD

ULE

RELAY BOARD

READER 2

Connect the included power transformer to

the IPAC power input connector using at

least 18 gauge wire (AWG).

NOTE: When installing, make all wire

connections prior to applying power to

the unit.

CONNECT POWER

Wiring

RELAY BOARD

• DO NOT use ANY power supply other than those supplied with your access control panel.

• DO NOT power electronic strikes and latches with the same power supply used to power the access control panel; doing so will cause DAMAGE to the access control panel.

• DO NOT connect the power supply to a switched outlet or otherwise controlled AC outlet.

• DO NOT connect the power supply to the 120 Vac outlet until ALL wiring is completed.

• Install the transient noise suppression device (MOV) supplied with the access control panel for AC powered devices and Diode for DC powered devices.

Page 8: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

8

USB - Device

PE

RIP

HE

RA

LB

OA

RD

CO

NFIG

LA

N

US

B -

AD

MIN

REX 1

SENSE

COM

SHLDO NO

N1

2

3

4

IPPNL

MAC 00:00:00:00:00:00

CP# TEC–3K–YYYYL

CO

NFIG

O NO

N1

2

3

4

Connect the IPAC to an available port on

an Internet modem, router, DSL Modem,

or network switch using a Cat-5 or Cat-6

Ethernet cable.

CONNECT ETHERNET

PERIPHERAL BOARD

Wiring

Page 9: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

9

On the touch screen, press “DHCP”, then

“Advanced Settings”.

Press “Go Cloud”. IPAC will

download latest fi rmware and

restart.

Programming

ADD IPAC PANEL TO A CLOUD ACCOUNT

1

2

Confi rm the proper fi rmware has been downloaded after the IPAC restarts.

• Press “MISC” then “System Info”.

• Firmware Version should be “5.0.21”.

• If fi rmware starts with a “1” (e.g. 1.2.2) press the “Go Cloud” button and confi rm IPAC downloads the latest

fi rmware and restarts.

3

Page 10: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

10

Navigate to Setup –> Sites and Doors –> New Site.

Programming

CREATE A NEW SITE

1

Enter all required fi elds.2

3 Click “Save Site”.

Return the #1 Dipswitch to the OFF position to return IPAC to user mode.

From your computer or tablet open a web browser and log into IPAC hosted service account (LiftMaster.com/IPAC).

From the hosted account page, click “Setup” from the top toolbar.

Navigate to Setup –> Sites and Doors –> New Control Panel.

4

5

6 Name the IPAC panel and enter

Control Panel Number (CP#).

Optional comments may be added

to describe control panel in further

detail.

7 Click “Save Control Panel”.

Page 11: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

11

Programming

ADD DOORS/GATES

2 Click “Add Door”.

3 Enter Door Name. Select Control Panel

from drop-down.

4 Click “Next”.

5 Select Board from

drop-down. Select Node

from drop-down.

NOTES:

Board 1 Node 1 = Door 1

Board 1 Node 2 = Door 2

Navigate to Setup –> Sites and Doors. NOTE: If already on the “Site” page, click ”Add Door”1

Page 12: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

12

Programming

CONFIGURE A DOOR

2 Enter the door name.

3 Confi rm door settings.

4 Set a door unlock schedule if the

gate or door is held open or does

not require a credential to enter at

certain times. Note: Instructions for

how to a schedule can be found on

page 22.

The default values are appropriate

for most applications.

5 Select “Yes” for control from

browser (allows administrator to

open door through web).

6 Click “Save Door”.

Navigate to Setup –> Sites and Doors –> Edit Door. NOTE: If already creating a new door, the user will already be on

this page. Follow the steps below.1

Page 13: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

13

USB - Device

PE

RIP

HE

RA

LB

OA

RD

CO

NFIG

LA

N

US

B -

AD

MIN

REX 1

SENSE

COM

SHLDO NO

N1

2

3

4

IPPNL

MAC 00:00:00:00:00:00

CP# TEC–3K–YYYYL

CO

NFIG

O NO

N1

2

3

4

COM LINK -> A B

N.C.

COM

SHLD

N.O.

RELA

Y 1

N.C.

COM

SHLD

N.O.

AU

X 1

N.C.

COM

SHLD

N.O.

RELA

Y 2

N.C.

COM

SHLD

N.O.

AU

X 2

INP

UT 1

REX

2

INP

UT 2

SH

LD

CO

M

SEN

SE

SH

LD

CO

M

SEN

SE

SH

LD

CO

M

SEN

SE

GN

D

SH

IELD

LED

-GR

N

BU

Z

HO

LD

LED

-RED

D0

D1

12V

GN

D

SH

LD

LED

-GR

N

BU

Z

HO

LD

LED

-RED

D0

D1

12V

READER 1

CO

MM

LIN

K M

OD

ULE

RELAY BOARD

READER 2

Wiring

Unpack and mount IPAC using the provided knockouts.

If a Request to Exit (REX) switch is used,

wire it to REX 1 on the main board of the

unit. (Postal Lock switch)

Primary Relay

Auxiliary Relay Connected Monitor Input

WIRE DOOR #1

1

2

REX 1

3

4

Connect Wiegand input to Door #1 to trigger the Primary and Auxiliary relays.

Connect monitored input

for Door #1 (door monitor

switch).

RELAY BOARD

PERIPHERAL BOARD REX SWITCH

Page 14: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

14

COM LINK -> A B

N.C.

COM

SHLD

N.O.

RELA

Y 1

N.C.

COM

SHLD

N.O.

AU

X 1

N.C.

COM

SHLD

N.O.

RELA

Y 2

N.C.

COM

SHLD

N.O.

AU

X 2

INP

UT 1

REX

2

INP

UT 2

SH

LD

CO

M

SEN

SE

SH

LD

CO

M

SEN

SE

SH

LD

CO

M

SEN

SE

GN

D

SH

IELD

LED

-GR

N

BU

Z

HO

LD

LED

-RED

D0

D1

12V

GN

D

SH

LD

LED

-GR

N

BU

Z

HO

LD

LED

-RED

D0

D1

12V

READER 1

CO

MM

LIN

K M

OD

ULE

RELAY BOARD

READER 2

Connected Monitor Input

WIRE DOOR #2 (IF APPLICABLE)

Wiring

1

Primary Relay

Auxiliary Relay

If a Request to Exit (REX) switch is

used, wire it to REX 2.

2

3

Connect Wiegand input to Door #2 to trigger the Primary and Auxiliary relays.

Connect monitored input

for Door #2 (door monitor

switch).

REX 2

RELAY BOARD

REX SWITCH

Page 15: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

15

Navigate to Users –> Telephone Entry System –> New Telephone Directory.

Navigate to Setup –> Sites and Doors –> Site Directory.

Click on the desired site.

Programming

CREATE A DIRECTORY

CONFIGURE IPAC

1

1

2

3

2 Name the directory.

3 Set the directory code

length. The directory code

is a 4-6 digit code guests

use to dial a resident from

the IPAC. WARNING: The

code length cannot be

changed once residents

are added to the directory.4 Click “Save”.

Select “More

Operations”

and then “Add

IPAC Device”.

Programming

Page 16: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

16

Programming

CONFIGURE IPAC

4

5

Select IPAC Control Panel. Enter device

name.

Enter SIP Account Information.

Domain: SIP.Phone.com

SIP Username: (Example: 81976)

SIP Password: (Example: 8$Sh77y69dBm7v)

Page 17: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

17

Set other parameters:

Programming

CONFIGURE IPAC

6

7 Click “Save”.

Enter greeting message (appears at top of

IPAC screen).

GATE 1:

• Select DTMF key to grant access.

• Select Gate/Door to be controlled.

• Click Yes to enable access code entry from

IPAC panel.

GATE 2 (Optional):

• Select DTMF key to grant access.

• Select Gate/Door to be controlled.

• Click Yes to enable access code entry from

IPAC panel.

Edit Speaker and Mic Volume.

Select a Telephone Directory (the list of names

that will display on IPAC).

Page 18: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

18

Select “Site” pull-down menu

and select “All Sites” or the

desired site.

Assign a schedule to each door/gate this group can open. Leave

schedule blank if group has no rights to that door/gate. NOTE: See

“schedule” section in this manual for how to create a new schedule.

Programming

SET GROUP PRIVILEGES

Name Group and click “Save Group”.2

3

4

Navigate to Users –> New Group.1

Scroll to the bottom of the Site list to see the options to Save Group.5

Page 19: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

19

Navigate to Setup –> Cards –> Add Cards.

Programming

BULK LOAD CARDS/TRANSMITTERS

1

2 Select the format of the card/transmitter. NOTE: Different formats may display ad-

ditional settings.

3 Enter fi rst and

last Card Number.

Leave off leading

zeros. It is

recommended to

pick a standard

format for

all imported

credentials.

4 Enter Facility code.

5 Click “Add Cards”.

Page 20: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

20

Enter First Name, middle name, and last

name. Click “Save Identity”.

Assign PIN (Optional).

• Click “Credentials” Tab.

• Enter PIN or click 4, 5, 6, 7, or 8 to auto-assign PIN.

• Click “Save PIN” button.

To add a card, transmitter, or other credential, click “Choose” to open “Card Bank” and add credential to user.

• Select credential from “Add Cards” pop-up menu.

• Use fi lter or arrows to search for card.

• User can have multiple credentials.

• Click (X) to close “Add Cards” pop-up menu.

Programming

CREATE CREDENTIALED USER

For someone with a card, transmitter, PIN, or other credential:

2

3

4

Navigate to Users –> New User.1

Page 21: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

21

Set dates user will have access. Leave blank if permanent user.

Repeat as needed.

Select “Groups” tab.

• Click “Choose” button.

• Select group(s) from “Select Group” pop-up menu. NOTE: User can be in multiple groups.

• Click (X) to close “Add Cards” pop-up menu.

Programming

CREATE CREDENTIALED USER

5

6

7

Page 22: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

22

Navigate to Users –> Telephone Entry System –> New Resident.

Programming

CREATE A RESIDENT

A resident is someone with a phone number.

1

2

3

Select Directory.

Enter the resident’s name as it will

appear on IPAC.

4 Enter Directory Code (Or use

the buttons on the right to

auto-populate). The Directory Code

is the number a guest can use to

quickly call the associated resident

from IPAC.

5 Enter resident information. NOTE:

it is important to enter all 10 digits

of the resident’s phone number.

6 Set “Do Not Disturb Schedule”

(Optional). IPAC will not allow calls

to the resident during these times

and the guest is notifi ed.

7 If resident does not want to be search-able in directory, select “YES”.

8 Click “Save”.

Page 23: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

23

Navigate to Setup –> Schedules –> New Schedule.

Programming

CREATE A SCHEDULE

1

2

NOTE: Schedules have many uses when programming your IPAC and Door IPDC.

• Access times for groups assigned to each entrance. During the selected times, members of a group can present a card,

PIN, transmitter, or other credential to open the gate or door.

• Use to hold open a gate or leave a door unlocked. Select the times the gate or door should be open or unlocked.

• As a “do not call time” for residents. During the selected times guest cannot call the resident from IPAC.

3 Click and drag up or down to

block out the times which the

schedule will be ACTIVE.

Enter schedule name.

4 Click “Save Schedule”.

Page 24: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

24

Navigate to Setup –> Notifi cations –> New Notifi cation.

Programming

SET A NOTIFICATION

1

2

3

4

Select all sites the notifi cation rule will apply to .

Enter a description of the

notifi cation rule and enter the email

address to send the notifi cation.

Select the events to trigger

the notifi cation.

Page 25: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

25

Programming

If a notifi cation is tied to

a group or user, add the

group or user.

6 If desired, select

a schedule for the

notifi cation rule to

be active.

7 Click “Save Notifi cation”.

5

Page 26: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

26

Navigate to Setup –> Account –> Administrators.

Programming

CREATE A NEW SENIOR ADMINISTRATOR

1

2

3

Click “New”

next to “Senior

Administrators”.

Enter the administrator

information.

4 Determine whether this new

administrator can create other

administrators.

5 Enter the Administrator ID,

Password, Secret Qestion, and

Secret Answer.

6 Enter your password to confi rm

who is creating the new

administrator.

7 Click “Save Administrator”.

Page 27: 0138241 IPAC Guide Wiring and Cloud Programming up and confi guring any IPACs and door ... Not responsible for conflicts between the information listed in the wiring diagram and ...

27

Testing

2

3

4

5

Pick up the resident’s or called phone and press the desired number to trigger the door to open. The IPAC welcome

message will appear.

After the welcome message, confi rm the customizable message has appeared in the upper left of the IPAC display and

the clock is correct in the upper right of the IPAC display.

Confi rm all Wiegand inputs correctly trigger the relays and events appear in the Cloud software Activity Log. When

everything is working properly the IPAC is ready to be installed.

Install the IPAC. NOTE: Be sure all wiring is connected before applying power.

Press the directory button on the IPAC touch screen. The list of residents should appear. Press the desired name and

then press the “call” button. IPAC will show a “connecting” then a “calling” message and will ring.

AFTER COMPLETING THE SOFTWARE SETUP

Try to make a phone call from IPAC.

1