Post on 25-Oct-2021
Aether BiomedicalZeus Brochure
1
Aether BiomedicalZeus Brochure
1 1
Zeus is a multi-action, multi-articulated bionic limb combining ease of control with an elegant, robust design. The fingers and thumb provide a firm grasp to perform everyday tasks with ease. The fingers stall individually, allowing them to conform to the shape of the object, regardless of shape and size. Users can choose from 12 grip modes with an added option of 2 custom grip modes.
• Zeus is the strongest bionic hand on the market (152N grip force)
• Zeus is impact resistant and can carry loads up to 35 Kgs.
• Even in the rare case of damage, digits can be repaired on-site by a certified Zeus clinician without the need to ship off the product; the hand stays with the user, not the manufacturer!
EMG electrodes use advanced signal processing and provide wireless gain adjustment. The sensitivity and smoothness of the signal can also be adjusted. With a height of only 6.7mm, the electrode system is the thinnest cased electrode, facilitating the creation of a truly slim line, sealed socket.
Zeus the bionic limb
Aether BiomedicalZeus Brochure
1
Aether BiomedicalZeus Brochure
3
Zeus is not just an artificial part of the body
which extends beyond biological capabilities;
it’s also the bridge between
human limitations and
human potential.
Aether BiomedicalZeus Brochure
4
Closed loop motor control sensing finger position and applied force for proportional control
Key Features
4
Compliant fingers to prevent breaking of finger units
5 Individually motorized articulating digits allowing for dexterity in movement
Opposable thumb design with inbuilt sensor for position
detection
100% customizabilityfor perfect aesthetic
appearance
Innovativepalm designusing hard & soft material for reduced weight and lateral shock absorption
12 Selectable + 2 User configurable grip patterns
The strongest bionic
hand (152N grip force)
Aether BiomedicalZeus Brochure
5
Opposed Grips
Power Grip
Active Index Grip
This grip is useful for opera-ting appliances which require trigger mechanisms like power tools, sprays and hairdryers. The hand grasps the object and conforms to the shape of the object. The index finger is controlled proportionately to operate the trigger mechanism. The speed and force applied by the index finger can be modulated on the basis of EMG signal.
In this grip, the thumb is opposed, while all of the other four fingers close until they meet the object or receivea closing signal. The strong gripprovides 152N of force spread overall four fingers and thumb. This grip is useful for lifting large objects, shaking hands or crushing empty cans. Individual finger stalling means the grip conforms to the shape of the object so that you can lift things such as a wine glass. Thanks to advanced sensors, the hand optimizes the force applied to the object.
Aether BiomedicalZeus Brochure
6
Precision Open Grip
In this grip, the thumb moves to a mid-point and stops. The index finger can be controlled proportionately to form a pinch. Middle, ring and little fingers close fully. This grip can be used for picking up small objects from a table or holding a pencil.
In this grip, the thumb moves to a mid-point and stops. The index finger can be controlled proportionately to form a pinch. Middle, ring and little fingers remain open. This grip can be used for picking up delicate objects and reaching between small gaps.
Precision Closed Grip
Aether BiomedicalZeus Brochure
7
Tripod Closed Grip
This grip allows you to hold a variety of daily life objects like a pen, car keys, eggs or jar lids. The
thumb assumes a mid-point position while the index and middle finger move
proportionately to reach the tip of the thumb. The ring finger and little
finger remain open.
The grip a l l o w s you to hold medium sized objects. The thumb assumes a mid-point position while the index and middle finger move proportionately to reach the tip of the thumb. The ring finger and little finger close fully.
Tripod Open Grip
Aether BiomedicalZeus Brochure
8
Non-Opposed Grips
Finger Point
The hand opens to the extent where it provides a slight curvature to support plates, bowls and books. The rubberized palm provides a flat, non- slippery surface to confidently hold objects in this grip
Open Palm
This is a static grip,where the index fingerremains in a pointingposition and the rest of the fingers close. This can be used for typing, operating a mobile phone or pushing switches and buttons.
Aether BiomedicalZeus Brochure
9
Hook Grip
Key Grip
This is a commonly used grip for picking up thin flat objects, holding a spoon or turning a page. The four fingers assume a position to provide a flat platform for the thumb. The thumb can be contro-lled proportionately to open and close.
This grip is used for lifting up heavy objects like brief-cases, shopping bags and gym equipment. Because of the self-locking nature of Zeus, the fingers have a static grip capacity of 35kgs, allowing you to lift heavy objects with ease. This grip can also be used to provide support when getting up from a seated position.
Aether BiomedicalZeus Brochure
10
This grip gives a naturaland lifelike appearanceto the hand. The thumbis in a non -opposedposition and closed.The fingers are closedslightly. This type of grip is the ideal state for the hand during periods of inactivity.
This grip is used to operate a computer mouse. The hand assumes the position of the mouse. The index finger and the middle finger can be controlled proportionately to push left and right buttons respectively.
Mouse Grip
Resting Hand
Aether BiomedicalZeus Brochure
11
TechnicalSpecification
7.4V, 2200mAh
560g
1.5sec
152N
500N 350N
182.7mm80.6mm29.9mm
Flexible battery pack with magnetic charging
Device weight QWD
Max. closing time
Grip force
Force on chassis (static, supporting the hand)
Force with closed hand (static, carrying a bag)
Height (finger tip to wrist base)
Palm Width
Thickness
Aether BiomedicalZeus Brochure
12
The signal processing box collects and filters the electrode EMG signals, and outputs envelope EMG signals to the terminal device. The signal processing box contains a Bluetooth module, which allows the Element to communicate with the desktop software.
The user can view the EMG signals and adjust electrode gains through the desktop software.
Dimensions (Element Box LxWxH) 38mm x 22.8mm x 3.85mmDimensions (IBT Electrodes LxWxH) 28.8mm x 16.8mm x 6.7mmInput voltage 5 to 10VExpected service life 3 years
Element Sensor System
IBT Electrodes
IBT Electrodes
Signal Processing Box
The Element System has three components: » IBT Electrodes (up to 2) » Signal Processing Box » Element Desktop Software
The Element sends out standard EMG signals detected from the IBT Electrodes placed on the user’s skin. The Element System is an alterna-tive to standard suction socket myo-electrodes, with the advantages of a lower profile, digital signal processing, and wireless gain adjust-ment.
The electrodes detect and amplify raw electromyography (EMG) signals from the user’s skin. The electrodes plug into the signal proces-sing box.
Aether BiomedicalZeus Brochure
13
BatteriesWorry less about making space for batteries. At less than 4mm thick and leveraging space-age flexible battery technology, FlexCells can fit into tight spaces. Build a natural-looking and streamlined prosthesis shell. Our low-profile design means no bulges for battery space. Patients enjoy the look; prosthetists appreciate the ease of fabrication.
CONVENTIONAL BATTERY PLACEMENT
FLEXCELL PLACEMENT
Flexible Battery System
One Button For EverythingThe single button interface for the charging port lets you check batte-ry function easily. Press and hold the button to power the device on or off, or press it once to show battery level. Because it’s only 5mm tall, the charging port can be fabricated into a socket with little inward protru-sion, allowing for more versatility in battery and controller placement. Now fabricated with injection molded plastics, the charging port face can withstand more drops and bumps than before.
The magnetic charging connector simply snaps onto the charging port to charge the batteries. If the charger cable is inadvertently pulled, the controller comes right off, leaving the prosthesis safe.
Dimensions Standard 4.9mm X 1.57mm X 0.08mmVoltage output 7.4V DCCapacity 550 mAhExpected service life 500 charges / 2 years Weight 31g
Aether BiomedicalZeus Brochure
14
» for Battery System - 1 year warranty
Warranty andCustomizability100% Customizability
Warranty
Patients can choose from the different colors and patterns that are available and customize their hand for perfect aesthetic appearance.
Zeus comes with a 2-year-standard warranty from Aether Biomedical Sp. z o.o. In addition, the following warranty packages are available at the date of purchase:
Aether BiomedicalZeus Brochure
15
Aether BiomedicalAether Biomedical is a medical robotics company focused on biosignal processing and bionic limbs for upper limb amputees. Since the company’s founding, our team has expanded to represent diverse specialties such as engineering, medicine, design and strategy. We are striving to shake up the world of medical technology innovation. Our products are engineered with precision, designed to exceed global standards and are fundamentally driven by human need. Our solutions are conceived and developed in- house and scaled externally with the help of manufacturers and distributors.
www.aetherbiomedical.com
ul. Królowej Jadwigi 43,61-880 Poznań
POLAND
72A/ 74, Arjun Nagar,Safdarjung Enclave,New Delhi - 110029
INDIA
phone: POLAND +48 515 856 103
INDIA +91 9636842365
e-mail: info@aetherbiomedical.com
Aether BiomedicalZeus Brochure
2
Aether BiomedicalZeus Brochure
3 3