Contents
1. Components2. Capabilities3. Maintenance4. Summary of bacteriological analysis process
Título de la presentación
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 3
1. Componentes1. Components
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 4
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 5
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 6
– Filtration apparatus– Incubator– Culture Medium– Petri Dishes– Sampling Methods– Turbidimeter– pH and Chlorine meters – Consumables
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 7
Filtration apparatus
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 8
Spares case
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 9
External battery
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 10
2. Capabilities
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 11
CAPABILITIES
• Turbidity
• pH
• Free and total chlorine
• Bacteriological analysis (thermotolerant faecal coliforms)
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 12
3. Maintenace
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 13
GENERAL MAINTENANCE
Weekly
• Wash, rinse and dry the filtration apparatus
• Apply a smear of silicone grease to the black rubber O-ring
• Charge the internal battery fully at the end of each week
CAREFULLY READ THE MANUAL
Monthly
• Check the incubator temperature and recalibrate if necessary
• Check all the kit components
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 14
BATTERY
• Never allow the internal battery to discharge fully.
• Never leave the incubator switched on for more than 18 consecutive hours
• Always recharge the battery at the end of the working period in the field.
• Recharge monthly during storage.
CAREFULLY READ THE MANUAL
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 15
4. Summary of the bacteriological analysis process
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 16
• Preparation:– Sterilization of equipment: (autoclave, pressure
cooker, methanol, boiling)– Petri: 15 min in autoclave or with methanol– Filtration apparatus: 15 min with methanol
– Culture medium (38 gr/500 ml distilled water)
– Petri dishes (Up to 16 daily samples)
• Filtration processFiltration volume (10 ml, 50 ml,100 ml) Filtration control
• Incubation (16-18 H 44ºC)
• Counting colonies: Yellow colour (faecal coliforms)
OXFAM-DELAGUA water analysis kitWATSAN M15 ERUWATSAN M15 ERU 17
• Presentation of resultsThe results are presented as CFU/100mlCFU (Colony forming units)
• 100 ml of sample (treated or very clean water) have been filtered: CFU/100ml = nº of identified colonies as coliforms• 50 ml of sample have been filtered: CFU/100ml = nº of identified colonies as coliforms x 2• 10 ml of sample have been filtered: CFU/100ml = nº of identified colonies as coliforms x 10
It is possible to use smaller volumes in samples with higher contamination.
The results should be calculated multiplying by the correspondent dilution factor.