INSILCOTE HV2000 Silicone coating for Insulator

Post on 12-Jun-2015

621 views 10 download

Tags:

description

RTV Silicone Coating or High voltage Insulator coating for the insulator. INSULATOR FLASH-OVER PROBLEM , We have solution We introduce a new Product INSILCOTE RTV Silicone Coating is a unique, room temperature vulcanizing(RTV)Silicone rubber formulation specifically developed for the prevention of pollution flashover of high voltage outdoor insulator. INSILCOTE released to the market in 1991. Our Company has been in service at over 350 sites in the most polluted areas of South Africa, India & has also found application around the world. Our product Type test done by:- 1. Electrical Research and Development Association (ERDA) 2. One Year period at Koeberg Insulator Pollution Testing Site(KIPTS) by Eskom R & D.( South Africa). 3. CPRI, Bangalore Advantages of our INSILCOTE product:- 1. Practical Coverage area 2.35 Sq.m/liter. 2. High Dielectric Strength 64KV/mm or 640KV/cm. 3. Cure rate is independent of humidity. 4. Silicone sheds for increasing the creepage distance of Insulator. 5. Useful for 11 KV to 400KV substation to 533 KVDC Substation. 6. Service at over 300 sites in the most polluted areas. 7. 20 years Experience in same field. 8. Hotline washing - not recommended. 9. Easy Application. 10. Optimum layer thickness of 0.3 to 0.5 mm. 11. Increase IR Value of Insulator. 12. Application done at Power Plant, Coastal Area, Steel, Cement, Chemical factories, fertilisers etc. Our other Products, 1. Microprocessor Based Alarm Annunciator. 2. Sequence of Event Recorders SER. 3. SF6 Gas Reclamation Unit 4. SF6 Gas Vacuuming and Refilling. 5. PLC based monitoring Systems 6. SF6 Gas Leak Detectors. 7. SF6 Gas Dew Point Meters. 8. On Line Partial Discharge Monitoring for GIS & AIS . 9. Insulator Creepage Extender etc About our product, pl visit our site www.pacificmicrosystems.co.in Our Product Tested by CPRI, Banglore & ERDA,Vadodara. Pl. find attached Performance Certificate from NPCIL,Tarapur(MS), ONGC,Uran & M/s JSW Energy Ltd,Ratnagiri(M.S) Thanking you & awaiting for your valuable inquiry. -- Jitendra Rathod Pacific Microsystems 10,Jijamata Market,Shahunagar, G-Block,MIDC Chinchwad,PUNE(M.S) Ph.020-27495115,09370276169 www.pacificmicrosystems.co.in

Transcript of INSILCOTE HV2000 Silicone coating for Insulator

Welcomes All of You

PUNE

We are Manufacturers of

* Alarm Annunciators

* Sequence of Events Recorder

* Microprocessor /PLC Based Systems.

We Represent some Foreign Companies for

* SF6 Gas Purification and Filling Units

* SF6 Gas Leak Detector and MultiParameter Analyzer

* Dew Point Meters

* Portable GIS Monitoring System

* Online GIS Monitoring System

Right Now We Introduce a New Product

INSILCOTE – RTV Silicone Rubber Coating,

From Mace Technologies, South Africa

( to be applied on Insulators in Substations.)

We are Sole Agent for this Product in India.

THE ELIMINATION OF POLLUTION FLASHOVER WITH THE

SYSTEM

INSILCOTE

IF A SUBSTATION IS SUFFERING FROM POLLUTION FLASHOVERS, WHAT ACTION SHOULD BE TAKEN?

• HAND CLEANING?• LIVE SPRAY WASHING?• INSTALL A FIXED WASHING SYSTEM?• SILICONE GREASING?• SILICONE RUBBER COATING?

LET’S EXAMINE THESE OPTIONS…..

HAND CLEANING

LIVESPRAYWASHING

ADVANTAGES:

• NO OUTAGE REQUIRED

DISADVANTAGES:

• NOT SUITED TO ALL CONTAMINANTS• NEEDS SPECIALISED EQUIPMENT• NEEDS SKILLED OPERATOR• NEEDS SOURCE OF LOW COND. WATER• FREQUENCY – NEEDS TO BE DONE OFTEN• INVOLVES RISK OF FLASHOVER FROM INCORRECT TECHNIQUE AND OVERSPRAY• DISTORTION OF FIELDS CAN CAUSE EQUIPMENT FAILURE

FIXEDSPRAYWASHINGSYSTEMS

…AND THE BIGGEST PROBLEM WITH ANYWASHING PROGRAM?….

TIMING!

• CLIMATIC VARIABLES & UNPREDICTABILITY

• MONITORING LIMITATIONS

• PRE-DEPOSITED VS. INSTANTANEOUS POLLUTION

SILICONEGREASING

ADVANTAGES:

• HYDROPHOBIC SURFACE

• CONTAMINANT ENCAPSULATION

• EXTEND MAINTENANCE INTERVAL

DISADVANTAGES:

• HIGH MATERIAL COST

• HIGH LABOUR COST

• LONG OUTAGES

• NOT FOR BULKY CONTAMINANTS

• SPENT MATERIAL DISPOSAL

• UNPLEASANT TASK

WARNING SIGN!

LEAKAGE CURRENTSARE DEGRADING THE GREASE TO A WHITE,WATER-ABSORBENTSILICA.

REPLACEMENT ISURGENTLY NEEDED.

SILICONE RUBBER COATING

GREASE IS NOW BEING LARGELY REPLACEDBY RTV SILICONE RUBBER COATINGS.

INSILCOTE HV2000 COATING FEATURES:

• EXCELLENT HYDROPHOBICITY• THE ABILITY TO TRANSFER THIS WATER- REPELLENCY TO A POLLUTION LAYER ON THE SURFACE• INHIBITS THE FORMATION OF MOIST LAYERS• LIMITS THE FLOW OF LEAKAGE CURRENTS• DUE TO IONISED CONTAMINANTS, IT PREVENTS FORMATION OF DRY BANDS

• INSILCOTE CONTAINS LOW MOLECULAR WEIGHT POLYMERS. THIS IMPARTS WATER REPELLANCY PROPERTIES TO THE POLLUTANTS WHICH GET ACCUMULATED ON THE SURFACE

• INSILCOTE HAS GOOD RESISTANCE TO ULTRA- VIOLATE RAYS AND MANY ORGANIC CHEMICALS

• IT PROVIDES GOOD SURFACE ARC RESISTANCE • USED FOR TRANSMISION LINES, SUBSTATIONS• USED FOR ALL POLLUTED AREAS LIKE CEMENT, CHEMICAL,STEEL, THERMAL POWER PLANTS

MACE TECHNOLOGIES’ INSILCOTE HV2000SILICONE RUBBER COATING HAS SERVEDFOR MORE THAN TWENTY YEARS IN THEMOST EXTREME ENVIRONMENTS.IT HAS BEEN USED IN SUBSTATIONS FROM 11kV TO 400kV AC AND 3kV TO 533kV DC.

INSILCOTE HV2000 IS THE ONLY INSULATOR COATING TO HAVE PASSED ESKOM’SSEVERE APPROVAL PROCEDURE AT THEIRKOEBERG TEST STATION ON THE HARSH WEST COAST OF SOUTH AFRICA

Time Trends

Date

00:00:002004/04/01

00:00:002004/03/15

00:00:002004/03/01

00:00:002004/02/15

00:00:002004/02/01

00:00:002004/01/15

00:00:002004/01/01

00:00:002003/12/15

00:00:002003/12/01

00:00:002003/11/15

00:00:002003/11/01

00:00:002003/10/15

00:00:002003/10/01

00:00:002003/09/15

00:00:002003/09/01

00:00:002003/08/15

00:00:002003/08/01

00:00:002003/07/15

00:00:002003/07/01

00:00:002003/06/15

00:00:002003/06/01

00:00:002003/05/15

00:00:002003/05/01

Acc

.CA

(C

A)

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

INSILCOTE

HV2000

COATINGTYPE 2UNCOATED

PORCELAIN

FOURTH FLASHOVER(sample disconnected)

NO FLASHOVERS

6 Mnths 9 Mnths

ACCUMULATED COULOMB AMPERE LEAKAGE CURRENTSMEASURED AT KOEBERG TEST STATION OVER A PERIOD OF 1 YEAR

Time of day trends of the average Peak Leakage Current

Time Of Day

23:0022:0021:0020:0019:0018:0017:0016:0015:0014:0013:0012:0011:0010:0009:0008:0007:0006:0005:0004:0003:0002:0001:00

Ave

rage

Pea

k Le

akag

e C

urre

nt (m

A)

5048

46

4442

4038

36

3432

3028

2624

22

2018

1614

12

108

64

2

EPOXY RESIN

EPDM RUBBERPORCELAIN

SILICONE RUBBER

INSILCOTE COATING

AVERAGE DAILY LEAKAGE CURRENT AMPLITUDES MEASURED AT KOEBERG TEST STATION OVER A PERIOD OF ONE YEAR

(IDENTICAL INSULATORS PRODUCED FROM DIFFERENT MATERIALS)

WATER “BEADS UP” ON A SILICONE RUBBER SURFACE…

EVEN WHEN THERE IS A THICK POLLUTION LAYER!

HYDROPHOBICITY OF INSILCOTE HV2000 AFTER3 YEARS ADJACENT TO A POWER STATION AND OPEN-CAST COAL MINE

TYPICAL MAINTENANCE INTERVALS AND/ORREPLACEMENT PERIODS ARE AS FOLLOWS:

WASHING…………………2 WEEKS – 1 YEAR

GREASING………………..1 TO 2 YEARS

INSILCOTE………………….10 TO 15 YEARS

Relative costs for 10 Years : Cleaning & Greasing – INR 6.9 Crores.

Silicone Rubber coating – INR 1.1 Crores. Features of Insilcote:

• 1 Kg covers 2.35 Sq.Meter Area of insulator

• Thickness of coating is 0.3 to 0.5 mm

• Application Procedure :

1. Cleaning, Drying

2. Application of Primer by Spray Gun

3. Application of Insilcote HV2000 by Spray gun

4. After application can charge the Insulator.

Price per Kg is Rs. 6000/- , Taxes & Application Charges are Extra.

Price per Sq. Meter Area of Insulator : Rs. 2550/-

Our INSILCOTE HV 2000 IS TESTED AT

CENTRAL POWER RESEARCH INSTITUTE, BANGALORE

ELECTRICAL RESEARCH & DEVELOPMENT ASSOCIATION, VADODARA

1. Inclined Plane Tracking & Erosion Test as per IEC-60587

2. Hydrophobicity Recovery Test as per REC Spec. No. 76/2006

3. Inclined Plane Tracking & Erosion Test as per ASTMD 2302-97

4. Arc Resistance as per ASTMD 495

Our Product is Sample Tested at

1. MSETCL, Kalwa

2. ADANI Power, Mundra

3. Neyveli Lignite Corp. Ltd.

4. ESSAR Steel, Hazira

Comparative Parameters of Porcelain Insulators before and after Application of Insilcote :

Before Application After Application

1. Volume Resistivity (Ohm Cm) 1011 2.3 x 1013

2. Surface Resistivity (Ohm) 109 1.5 x 1013

3. Puncture Value (KV/mm) 30 64

TECHNICAL CHARACTERISTICS of “ INSILCOTE HV2000 ”

As Supplied – •Appearance after mixing : Light blue•Liquid Specific Gravity at 25 degC : 1.33•Viscosity : 33.5 cSt•Thickness : 0.3 to 0.5 mm•Area Coverage per Kg : 2.35 Sq. Meters•Method of Application : By Spray Guns

As Cured –• Specific Gravity at 25 degC : 1.24 • Dielectric Strength : 64kV/mm• Permittivity : 2.4• Tracking & Erosion Resistance (IEC 60587 test ) : 1A4.5 • Hydrophobicity Recovery test As per REC Spec.76/2006 : HC1-HC2• Tracking Resistance at 2.5 KV ( ASTM D2303- 97 Test) : > 480 minutes•  Dry Arc Resistance ( ASTM D 495 -99) : 187.2 sec• Surface Resistivity : 1.5 x 1013 ohms• Volume Resistivity : 2.29 x 1013 ohm-meters• Loss Tangent at 50Hz : 0.0096• Dielectric Constant : 2.99• Dissipation factor : 0.010• Flammability under dry arcing. : No visible flame • Drying Time Skin over Time : 15 Minutes Cure through : 7 Hour

Customer List

1. Nuclear Power Corporation Ltd, Tarapore

2. MSETCL, Pune

3. Oil & Natural Gas Corporation Ltd, Uran

4. Delhi Metro Rail Corporation, New Delhi

5. UltraTech Cement, Raipur

6. JSW Energy Ltd, Ratnagiri

7. Indian Railways, Secunderabad

8. Mitsubhisi

Thanks All of You

Presentation at MSETCL, Head Office Meeting at Kolhapur on 23.9.2008

Presentation at GETCO, Head Office, Vadodara.

Thanks All of You