Commissioning Procedure

RBS 6201 2G

Requirements

Note:

• We will require OMT R41H for configuration of 2G part of 6201.

• BTS sw will be GSM-BTS_SW_G11A_R29E_(OMT_FORMAT)

• BSC sw will be GSM-BTS_SW_G11A_R29E_(BSC-FORMAT)

EC Bus Termination

OMT Login Port

E1 Interface

Incoming power to DUG from PDU

PIN Configuration

• Console Cable

• AT RJ 45 end--- 123

• AT 9 PIN connector--- 532

Go to create IDB then select the cabinet type as 6201 RUG, power system as -48 V Dc & cabinet system as Extended because in combo there are 4 no of Fans.

Define the sector as below, same as 2964

Select the configuration

Select all parameter then Tick mark on RBS configuration wizard click ok

Shelf definitions at 6201

Shelf “F1”

Shelf “E1”

Shelf “D1”

Shelf “C1”

Shelf “B1”

Now in configuration wizard define RU position. In this window we can define DUG,RUG,PDU shelf & slot position. In the beginning it will b shows as undefined

For 2G all RUs (DUG & RUG) shelves are define as C1/E1and corresponding slots are define as above i.e.(1,3,5,7,9,11,13) For the PDU s shelves are define as F1,D1,B1

& respective slots will be 1.

Define HUB Position as B1 then click OK

Define Feeder Loss in dB for all the sectors as per requirement

Define Delay for all the sectors as per requirement

Define PCM same as 2964, sand alone/cascade as per the site status

Define Tie (Mandatory)

This is same as 2964 External alarm definition window. Define it and then click ok

Click on YES

Define power as default , as below . Then click ok and install IDB.

After click on install IDB if wrong RBS operational sate is shown then u should change RBS state in local mode softly (go to cabinet –right click on DUG-change

maintenance state) then u observe a blue LED IS FLASING in DUG i.e. it is in local mode.

As describe in previous slide . Then click on the install IDB icon and go for the process . After complete IDB installation

change DUG maintenance state in REMOTE & physically the BLUE LED is OFF. Then go to Define Present RUS make PDU2

as not present .