Commissioning Procedure RBS 6201 2G

Transcript of Ericsson Rbs 6201 commisioning (1)

Page 1: Ericsson Rbs 6201 commisioning (1)

Commissioning Procedure

RBS 6201 2G

Page 2: Ericsson Rbs 6201 commisioning (1)

Requirements

Note:

• We will require OMT R41H for configuration of 2G part of 6201.

• BTS sw will be GSM-BTS_SW_G11A_R29E_(OMT_FORMAT)

• BSC sw will be GSM-BTS_SW_G11A_R29E_(BSC-FORMAT)

Page 3: Ericsson Rbs 6201 commisioning (1)

EC Bus Termination

OMT Login Port

E1 Interface

Incoming power to DUG from PDU

Page 4: Ericsson Rbs 6201 commisioning (1)

PIN Configuration

• Console Cable

• AT RJ 45 end--- 123

• AT 9 PIN connector--- 532

Page 5: Ericsson Rbs 6201 commisioning (1)

Go to create IDB then select the cabinet type as 6201 RUG, power system as -48 V Dc & cabinet system as Extended because in combo there are 4 no of Fans.

Page 6: Ericsson Rbs 6201 commisioning (1)

Define the sector as below, same as 2964

Page 7: Ericsson Rbs 6201 commisioning (1)

Select the configuration

Page 8: Ericsson Rbs 6201 commisioning (1)

Select all parameter then Tick mark on RBS configuration wizard click ok

Page 9: Ericsson Rbs 6201 commisioning (1)

Shelf definitions at 6201

Shelf “F1”

Shelf “E1”

Shelf “D1”

Shelf “C1”

Shelf “B1”

Page 10: Ericsson Rbs 6201 commisioning (1)

Now in configuration wizard define RU position. In this window we can define DUG,RUG,PDU shelf & slot position. In the beginning it will b shows as undefined

Page 11: Ericsson Rbs 6201 commisioning (1)

For 2G all RUs (DUG & RUG) shelves are define as C1/E1and corresponding slots are define as above i.e.(1,3,5,7,9,11,13) For the PDU s shelves are define as F1,D1,B1

& respective slots will be 1.

Page 12: Ericsson Rbs 6201 commisioning (1)

Define HUB Position as B1 then click OK

Page 13: Ericsson Rbs 6201 commisioning (1)

Define Feeder Loss in dB for all the sectors as per requirement

Page 14: Ericsson Rbs 6201 commisioning (1)

Define Delay for all the sectors as per requirement

Page 15: Ericsson Rbs 6201 commisioning (1)

Define PCM same as 2964, sand alone/cascade as per the site status

Page 16: Ericsson Rbs 6201 commisioning (1)

Define Tie (Mandatory)

Page 17: Ericsson Rbs 6201 commisioning (1)

This is same as 2964 External alarm definition window. Define it and then click ok

Page 18: Ericsson Rbs 6201 commisioning (1)

Click on YES

Page 19: Ericsson Rbs 6201 commisioning (1)

Define power as default , as below . Then click ok and install IDB.

Page 20: Ericsson Rbs 6201 commisioning (1)

After click on install IDB if wrong RBS operational sate is shown then u should change RBS state in local mode softly (go to cabinet –right click on DUG-change

maintenance state) then u observe a blue LED IS FLASING in DUG i.e. it is in local mode.

Page 21: Ericsson Rbs 6201 commisioning (1)

As describe in previous slide . Then click on the install IDB icon and go for the process . After complete IDB installation

change DUG maintenance state in REMOTE & physically the BLUE LED is OFF. Then go to Define Present RUS make PDU2

as not present .

Page 22: Ericsson Rbs 6201 commisioning (1)