WoodN Australia
ph: NSW +61 2 9673 8010 | VIC +61 3 8540 0503
email: [email protected] | [email protected]
web: www.woodn.com
WoodN Australia Physical Properties - V2.4 - 24072012.docx
Page 1 of 4
Green Building Council of Australia Green Building Council of Italy
Unless otherwise shown or indicated the below test results are valid for all classifications of WoodN profile range.
[ General Properties ] …
Flexural Stress
(test conditions: 23°C)
EN ISO 178.03
31.7 MPa - versatilis
20 MPa – aeternus
Modulus of Elasticity (MoE)
(test conditions: 23°C)
1.996 GPa - versatilis
1.6 GPa – aeternus
Penetration Property (Brinell) EN 1534:2000 HB = 2.40 Kg/mm2
Indentation UNI 4712:61 0.388 mm
Moisture Content EN 322:93 3.13%
Screw Extraction EN 322:93 142 N/mm
Dynamic - Mechanic Analysis ASTM D4065/95 78.7°C
Density GB/T1033-1986 950 - 1100 g/dm3
Dimensional change associated to Temperature.
(15 cycles) UNI 9429:89
ornans / ornans compositus
24h +50°C longitudinal
transversal
0%
-0.1%
24h + -20°C longitudinal
transversal
-0.13%
-0.25%
versatilis / aeternus
24h +50°C longitudinal
transversal
0.07%
-0.15%
24h + -20°C longitudinal
transversal
-0.03%
-0.30%
Dimensional Change assoc. to relative humidity.
(test at 20°C) EN 318:2002
aeternus from 65% to 85% longitudinal 0.3 mm/m
from 65% to 30% longitudinal -0.2 mm/m
WoodN Australia
ph: NSW +61 2 9673 8010 | VIC +61 3 8540 0503
email: [email protected] | [email protected]
web: www.woodn.com
WoodN Australia Physical Properties - V2.4 - 24072012.docx
Page 2 of 4
versatilis / ornans / ornans compositus from 65% to 85% longitudinal 0.3 mm/m
from 65% to 30% longitudinal -0.2 mm/m
Cold-check test
(after 15 cycles, range -20 to +50°C) UNI 9429:89
Level 5:
no surface defects
Linear thermal expansion coefficient
(range -10% to +70°C)
TMA ASTM
E 831/2006
longitudinal: 46.9µm/(m°C)
transversal: 48.9 µm/(m°C)
Swelling and Water absorption - versatilis
(7 days in cold water at 20°C) /
longitudinal: 0.07%
transversal: 0.23%
thickness: 1.22%
weight 2.89%
Impact resistance at a constant temp. - aeternus
(49x33 board) GB/T 14153 6.8 [KJ/m2]
Bending Strength - aeternus
(49x33 board) GB/T 9341-2000 34 [Mpa] ≥15
Resistance to flexion at room temp.- aeternus
(span = 500mm) EN 310:1983
Break 3266 N
Distortion
2mm 500 N
Determination of resistance to chlorinated water
- aeternus
(288h at 23°C)
UNI EN ISO 10545-
13:2000
UA Class
(neither dimensional nor
structural deterioration)
Hardness - ornans / ornans compositus
(shore D) EN ISO 868/97 73
Abrasion test on pre-finished varnished planks
(4000 revolutions, results comparable to AC4
classifications)
EN 13329/00
ornans / ornans compositus Weight variation (mg) -3399
Thickness variation (mm) -0.88
Abrasion test on pre-finished varnished planks
(6500 revolutions, results comparable to AC4
classifications)
EN 13329/00
ornans / ornans compositus Weight variation (mg) -5601
Thickness variation (mm) -1.40
Determination of friction coefficient
(for B.C.R.A. method flooring with varnish)
(0.40 - 0.74 --- satisfactory friction)
ornans / ornans compositus
Direction A → B ↓
Wet Surface 0.62 0.67
Dry Surface 0.67 0.68
WoodN Australia
ph: NSW +61 2 9673 8010 | VIC +61 3 8540 0503
email: [email protected] | [email protected]
web: www.woodn.com
WoodN Australia Physical Properties - V2.4 - 24072012.docx
Page 3 of 4
aeternus
Direction A → B ↓
Wet Surface 0.62 0.66
Dry Surface 0.58 0.63
Tolerance
(general tolerance on the extrusion of the profiles) ± 0.2 mm
[ Environmental ] …
Formaldehyde release Gas analysis
(qualified class E1 EN 14041) EN 717-2/94 0.1 mg HCHO / m2 h
(max. allowed 3.5 mg HCHO / (m2 h)
Plastic-Evaluation of the action of micro-
organism. Method A. - aeternus / versatilis
(scale 0 - 5, best obtainable: “0”)
EN ISO 846/97
Incubation temp. ±29°C for 4 weeks
Obtained test level: 1
Assessment of surface resistance to cold
liquids
(classification using test UNI 10944:2001)
EN 12720:1997 Class E
[ Slip Resistance ] …
Slip Resistance Classification for New Surface
Materials
(aeternus brushed surface – SB)
AS/NZS 4586:2004 Across Grain
Wet Pendulum Test W Low
Wet Barefoot Ramp Test 37° C
Oil Wet Ramp Test 31° R12
[ Fire Properties ] …
Fire classification of construction products
and building elements.
(classification using data from reaction to fire test)
EN 13501-1
(test method:
EN ISO 11925-2
EN ISO 9239-1:2002)
Class Bfl - S1
(self-extinguishing)
EN ISO 9239-1:2002
AS ISO 9239.1:2003
Mean
Critical Radiant Flux 10.62 kW/m2
Smoke Value 163.19 %min
WoodN Australia
ph: NSW +61 2 9673 8010 | VIC +61 3 8540 0503
email: [email protected] | [email protected]
web: www.woodn.com
WoodN Australia Physical Properties - V2.4 - 24072012.docx
Page 4 of 4
(radiant panel - isotropic material) UNI 9174/87 and
9174/A1/96
Class Bfl - S1
(self-extinguishing)
(small flame - isotropic material) UNI 8457/87 and
8457/A1/96
Class 1
(self-extinguishing)
Bushfire Attack Level ( BAL ) AS 3959:2009 BAL – 29
Fire Hazard Property - BCA AS/NZS 3837:1998 Group 3
Fire Indices AS/NZS 1530.3:1999
Ignitability Index
Spread of Flame
Heat Evolved
Smoke Developed
8 [0-20]
0 [0-10]
0 [0-10]
7 [0-10]
[ UV Resistance ] …
DT13835
aeternus SB – (light – W9)
SAE J1960-2004
ISO-105-A02-1993
500h – Colour Change 3
1000h – Colour Change 2-3
DT13835
aeternus SB – (dark – W13)
SAE J1960-2004
ISO-105-A02-1993
500h – Colour Change 3-4
1000h – Colour Change 3
This publication is intended as an aid for architects, engineers, specifiers and professionals involved in the design and specification of
WoodN products.
This publication is subject to modifications without notice.
Top Related