To make your t raceabi l i ty, our pr ior i ty…
TRACEABIL ITY AND MONITORING
SPY RF ® W I R E L E S S S Y S T E M S
2
S P Y R F ® S O L U T I O N S F O R S
Kitchen
> St André Les Lille Central kitchen (59)
> St Malo Police school (35)> Louvres Hotels (Le Ritz, Ambassador,> Hôtel du Louvre, Concorde Montparnasse,> Concorde St Lazare, Lutetia, Concorde Lafayette)> Charles Perrens Hospital (33)> Crous of Rennes (Student service) (35)> Mc Donalds (94)> Total service stations (multi-site)> HRC Restaurant " l’Arche " (Elior Group 61)> Européenne de confiserie (59)> Holder Moulin Bleu (59)
Supermarkets/dealers
> Total Argedis (Chanteraine site)
> Locaservice (59)> Leclerc Supermarkets (69)
Industries
> Delpierre Mer et Tradition (62)
> Milhaud Salting(81)> Berthillon Ice Cream(75)> Condat Paper mill (24)> CBV delicatessen (61)> …
St André Les Lille CentralKitchenApplication : control of ambient temperatures and products in coldchambers, storage and freezing areas.
Total ArgedisApplication : constant monitoring of chilled cabinets, cold chambers and ice boxes.
> "Archives Départementales" du Finistère (29)> Carnavalet Museum of Nice (06)> Paris National School of Beaux-Arts (75)
> Marc Chagall National Museum (06)
> Museum of Vire (14)> Fernand Léger Museum (06)> ...
Marc Chagall National Museum Application : Temperature and humidity recordfor preservation of artwork.
DelpierreMer et TraditionApplication : automaticdata archiving inIndustrial processes.
MUSEUMS ARCHIVES
FOOD
…and hundreds of working SPY RF® systemsall over the world.Ask us for your local distributor details.
JRI Maxant has developed a wireless traceability system which is adaptable and user friendly. Its aim is tomaximise security and gain time. This global traceability system SPY RF ® meets perfectly the requirementsof current regulations (HACCP, COFRAC and EU equivalents, ISO, GLP, GMP…) and quality control.
Today, JRI Maxant provides all the components of an efficient traceability system : on site radiocommunication survey, metrology, radio communication, hot line, software and maintenance contracts.Easy to use and delivering reliable results, the SPY RF ® system also offers automatic monitoring of yourlaboratory or production plant.
Some of our french users...
3
T A B L E Q U A L I T Y C O N T R O L
Blood Transfusion Centers and Blood Banks> EFS P.A.C.A.> (Marseille, Avignon, Gap, Aix, Cannes, Bastia, Ajaccio, > Toulon, Arles)> EFS NORMANDIE (76)> (Caen, Rouen, Lisieux, St Lô, Le Havre, Alençon,> Dieppe, Evreux)> EFS Pyrénées Méditerranée
Laboratories> Lexobio Lisieux (14)
Hospitals> CHU of Brest (29)
> CHRU of Lille (59)
> CHU de Grenoble (38)> CHU de Mulhouse (68)> CHU de Reims (51)> CHU de Nîmes (30)> J. Verdier Hospital (93)> "Assistance Publique des Hôpitaux de Paris" (75)> "Hospices Civiles de Lyon" (69)> Hospital of Dourdan (91)
Industries> Avantis Pharma (37)
> Alliance Healthcare (92)
> Pharmalog (27)> CERP (Multi-Site)> STEF (Multi-Site)> …
CHRU de LilleApplication : temperature monitoringIn chambers at -200°C, -80°C, -40 °Cand ovens.
> Transports Antoine Group (85)
> Logidis> Geodis Logistics Ile de France (multi-site)> Flash Europe (57)> …
Transports Antoine GroupApplication : real time data monitoringand product traceability.
Alliance HealthcareApplication : monitoring of temperature sensitive products.
HEALTH
TRANSPORT UNDER MONITORED TEMPERATURE
>MEASURES>RECORDS>COMMUNICATE>ARCHIVES>WARNS(real time alarm)
> EDF (77)> Siemens Automotive (31)> Virbac (06)> Procter & Gamble (41)> …
INDUSTRY
EXAMPLES OF WORKING SPY RF ® SOLSir ius L i te vers ion wi th repeater
Si r ius Transpor t Vers ion
4
UTION SYSTEMS
04,78
SPY RF ®
SPY RF ® RelaY
SPY RF ® ModeM
SPY RF ® AlarM
Ethernet Network
USB Cable
Radio communication (200 - 300 m)
Radio communication (800 - 1000 m)
04,78
Message alert
E-mail Alert
Visual and Audible Alert
Telephone Alert
SPY RF ® Ethernet ModemMODEMSPY RF ® Visu04,78
LEGEND
04,78
04,78
04,78
04,78
Second
ary bu
ilding Main
buildi
ng
MODEM
04,78
04,78
04,78
Consultation
MODEM
Consultation InternetServer
Sir ius Storage vers ion v ia Ethernet network
5
A M B I E N T S P Y R F ® R E C O R D
Possibility to addan anti-theft
on the mounting bracket
Replaceable battery
Push button
LCD screen
6
Pause mode
Channel number
Thresholdwarningindicator
Internal memory
Radio signal level
Measurement valueand unit
Pressurecompensation zone
Input cable protection
Splashproof
LED alarm
Record mode
T E C H N I C A L F E A T U R E SFrom -40°C to + 85°C
1�0.5°C from -30°C to +70°C ; �1°C above +70°C
Measurement range Channel number Measurement accuracy at 23°C
0,1°Cfrom -40°C to +85°C
ResolutionOperating conditions
Lithium battery4 years - not replaceable
Power supplyBattery life*
Internal (temperature PTC)1 to 90 minutes
Type of inputRecording interval
10 000 measurements1km line of sight
Internal memory Radio range
868 Mhz (ISM : Industrial Scientific Medical)25 mW
Radio bandPower
NoDigital display 123X69X30 mm (HxWxD)Dimensions
IP68
User manual
Protection index
Included
Complies with EN 12830 norm and recyclableaccording to EU regulation n° 2005 - 229
E R S
Key features> High color for easy location.> Economic.> Splashproof.
SPY RF ® TAmbient temperaturerecorder
Reference 06165
Conformities
T E C H N I C A L F E A T U R E Sfrom -30°C to + 70°C
1�0.5°C from -30°C to +70°C ; �1°C above +70°C
Measurement range Channel number Measurement accuracy at 23°C
0,1°Cfrom -30°C to +70°C
ResolutionOperating conditions
Lithium battery4 years - not replaceable
Power supplyBattery life*
Protruding (temperature PTC)30 seconds to 90 minutes
Type of inputRecording interval
10 000 measurements1km line of sight
Internal memory Radio range
868 Mhz ISM (Industrial Scientific Medical)25 mW
Radio bandPower
YesDigital display 123X69X30 mm (HxWxD)Dimensions
IP68Protection index Complies with EN 12830 norm and recyclable
according to EU regulation n° 2005 - 229Included User manual
Key features> Has a temperature protruding
probe for a faster responsetime.
> High color for easy location.> Splashproof and
contaminationproof.
SPY RF ® T+Ambient temperature recorderwith protruding probe
Reference 06166
AMBIENTSPYRF ®
RECORDERS
7
Did youknow?
JRI MAXANT offers COFRACcalibration certificatesfor its whole range
of recorders.
Conformities
T E C H N I C A L F E A T U R E SFrom -30°C to + 70°C; from 0 to 100% HR non condensing
1 or 2�0.5°C from -30°C to +70°C and 2% RHfrom 10% to 90% RH ; 3,5% above 90%
Measurement range Channel number
Measurement accuracy at 23°C
0,1°CFrom -30°C to +70°C
RésolutionOperating conditions
Lithium battery2 years - replaceable
Power supplyBattery life*
Internal (temperature et relative humidity)1 second to 90 minutes
Type of inputRecording interval
20 000 measurements (10000 per channel)1km line of sight
Internal memory Radio range
868 Mhz ISM (Industrial Scientific Medical)25 mW
Radio bandPower
YesDigital display 123X69X35 mm (HxWxD)Dimensions
IP34
User manual, wall-mounting bracket
Protection index
IncludedRecyclable according to EU regulation n° 2005 - 229
Key features> Has a low inertia during
measurement variations.> The probe has integrated
protection.> Replaceable battery.
SPY RF ® THAmbient temperature andrelative humidity recorder
Reference 06167
Conformities
* Depending on operating conditions.
T E C H N I C A L F E A T U R E SMeasurement rangeChannel numberMeasurement accuracy at 23°CResolutionOperating conditionsPower supplyBattery life*: Type of inputRecording intervalInternal memoryRadio rangeRadio band Power
DimensionsProtection index
from -200°C to + 400°C/4-20mA/0-1V/dry contact1 or 2
�0.3°C (on short MR** only)0,1°C
From -30°C to +70°CLithium battery
2 years - replaceableExternal (PT100/PT1000/4-20mA/ 0-20Ma/0-1V/dry contact)
1 second to 90 minutes10 000 measurements per channel
1km line of sight868 Mhz ISM (Industrial Scientific Medical)
25 mWDigital display Yes
123X69X35 mm (HxWxD)IP65
Conformities Complies with EN 12830 norm and recyclable accordingto EU regulation n° 2005 - 229
Included User manual, wall-mounting bracket and cable input protection
Conformities Complies with EN 12830 norm and recyclable accordingto EU regulation n° 2005 - 229
Included User manual, wall-mounting bracket and cable input protection
Conformities Complies with EN 12830 norm and recyclable accordingto EU regulation n°2005 - 229
IncludedUser manual, wall-mounting bracket, cable input protection,
3 points COFRAC calibration certificate (-18, +2, +8°C), temperature probe supplied with 3m cable
Key features> Compatible with most
probes and sensors : PT100,PT1000, 4-20mA, 0-1 V,contact.
> Monitors all types oftemperature-controlledequipment(-200°C to +400°C)
> Allows recording to startwhen specific events occur.
> Possibility to have differenttypes of input in2-channel model (analogueor electrical).
SPY RF ® UUniversal recorder
Reference : U1 : 06168U2 : 06169
T E C H N I C A L F E A T U R E SMeasurement range
Channel number
Measurement accuracy at 23°C
ResolutionOperating conditionsPower supplyBattery life* Type of inputRecording intervalInternal memoryRadio rangeRadio band PowerDigital display
Protection index
T probe : from -55°C to +80°C and TH probe :from -30°C to +70°C from o to 100% HR non condensing
1 or 2
0,1°CFrom -30°C to +70°C
Lithium battery2 years - replaceable
External (temperature, relative humidity and dry contact) 1 second to 90 minutes
10 000 measurements per channel1 Km line of sight
868 Mhz ISM (Industrial Scientific Medical)25 mW
YesDimensions 123X69X35 mm (HxWxD)
IP65
Key features> Probes are interchangeable
for easy maintenance.> Suitable for dry contact
inputs.> Allows recording to start
when a specific event occurs. > Possibility to have different
type of input on the2 channels model(digital or electrical).
SPY RF ® NDigital recorder(T° / RH / contact)
Reference :N1 : 06428N2 : 06429
T E C H N I C A L F E A T U R E S
Measurement range
Channel numberResolutionOperating conditionsPower supplyBattery life* Type of inputRecording intervalInternal memoryRadio rangeRadio band PowerDigital display
Protection index
SPY RF ® Health NT : from -55°C to +80°CTH : from -30°C to +70°C
SPY RF ® Health U
T : from -50°C to +180°C
� 0.3°C with probe
1 or 20,1°C
Measurement accuracy between+2°C and +8°C
From -30°C to +70°CLithium battery
2 years - replaceableExternal (temperature, relative humidity and dry contact)
1 second to 90 minutes10 000 measurements per channel
1km line of sight868 Mhz ISM (Industrial Scientific Medical)
25 mWYes
Dimensions 123X69X35 mm (HxWxD)IP65
Key features> Possibility to monitor the hot
and cold spots of yourchamber (using the 2-channelSPY RF ® Health recorder).
> High accuracy in the range+2 to +8°C.
> Supplied with COFRACcalibration certificates(equivalent to EU standards).
Reference :U1 : 08634U2 : 08635N1 : 08636N2 : 08637
D I S T A N T S P Y R F ® R E C O R D
8
SPY RF ® HealthDedicated range for pharmacy and medical biologydeveloped in collaborationwith the experts of ParisHospitals Trust (" AP-HP ")from SPY RF ® U and N.
� 0.3°C and 2% RH with probe
�0.5°C (within a range of 50°C) RH : �2% RH from0 to 90% RH and �3% from 90% to 100% RH (with probe)
T E C H N I C A L F E A T U R E SMeasurement rangeChannel numberMeasurement accuracy at 23°CResolutionOperating conditionsPower supplyBattery life*Type of inputRecording intervalInternal memory Radio rangeRadio bandPower
DimensionsProtection index
From 0 to 200Hz1 or 2
-1
FRom -30°C to +70°CLithium battery
2 years - replaceableExternal (pulses)
1 second to 90 minutes10 000 measurements per channel
1km line of sight868 Mhz ISM (Industrial Scientific Medical)
25 mW
123X69X35 mm (HxWxD)IP65
Key features> Compatible with most pulse
sensors.
SPY RF ® CRecorder for countable events
Reference :C1 : 06426C2 : 06427
T E C H N I C A L F E A T U R E SMeasurement rangeChannel numberMeasurement accuracy at 23°CResolutionOperating conditionsPower supplyBattery life*Type of inputRecording intervalInternal memory Radio rangeRadio bandPower
DimensionsProtection index
Depending on the probe from +200°C to +1370°C1 or 2
�1°C (for short MR only)0,1°C
From -30°C to +70°CLithium battery
2 years - replaceableExternal (thermocouple) 1 second to 90 minutes
10 000 measurements per channel1km line of sight
868 Mhz ISM (Industrial Scientific Medical)25 mW
123X69X35 mm (HxWxD)Digital display Yes
Digital display Yes
IP65
Key features> Compatible with all types
of thermocouple K probes.> Compatible with Hygitherm
probe, specially designedfor pipes.
SPY RF ® TCTemperature recorder forThermocouple K probes
Reference :TC1 : 06170TC2 : 06171
E R S
9
DISTANTSPYRF ®
RECORDERS
Conformities Recyclable according to EU regulation n° 2005 - 229Included User manual, wall-mounting bracket and cable input protection
Conformities Recyclable according to EU regulation n° 2005 - 229Included User manual, wall-mounting bracket and cable input protection
T E C H N I C A L F E A T U R E SMeasurement rangeChannel numberMeasurement accuracy at 23°CResolutionOperating conditionsPower supplyBattery life*Type of inputRecording intervalInternal memory Radio rangeRadio bandPower
DimensionsProtection index
-80°C to +40°C depending on sensors1
�0.1°C from -20 to +40°C and -0.2°C from -80 to -20°C0,01°C
From -30°C to +70°CLithium battery
1 years - replaceableExternal (PT100)
1 second to 90 minutes10 000 measurements per channel
1km line of sight868 Mhz ISM (Industrial Scientific Medical)
25 mWDigital display Yes
123X69X35 mm (HxWxD)IP65
Conformities Recyclable according to EU regulation n° 2005 - 229Included User manual, wall-mounting bracket, cable input protection and PT100 probe
Key features> Resolution of 0,01°C.> Supplied with a 1/3 DIN
PT100 probe.> High accuracy.
SPY RF ® ReferencEReference Device
Reference 09509
* Depending on operating conditions.** Measurement range.
R A D I O C O M M U N I C A T I O N D EV I C E S
A C C E S S O R I E S
10
A C C E S S O R I E S A N D P E R I P
Connects to your PC, enables communication with SPY RF ® recorders.> Communicates with an unlimited number of recorders.> USB connector.> Remote alarm driven by integrated dry contact output
(vocal telephonic transmitter, buzzer, light). > Software or PC failure alarm.> Can be used with or without SPY RF ® RelaY.> Supplied with a wall-mounting bracket.> Operating conditions from 0°C to +70°C.
SPY RF ® ModeM
Enables Ethernet connection to maximise distances betweenrecorders and PC server.> Operating conditions from 0°C to +40°C.
* POE : Power Over Ethernet* VDC : Main power supply required (9VDC)
ModeM Ethernet POE / VDC*References :VDC : 08913POE : 08917
References :USB : 06337RS232 : 06214
Enables direct RF communication to maximise distances between recorders and PC server.> Can relay one or more SPY RF ®.> Works with external power supply and supplied with a backup battery.> Include two power ranges : 25 mW to communicate with recorders and
500 mW to communicate with ModeM.> Supplied with a wall-mounting bracket.> Operating conditions from -10°C to +70°C
SPY RF® RelaY
Reference 06215
Did youknow ?
JRI Maxant hasdeveloped a deviceto enable on site radiocommunication survey,
the SPY RF ® TesT.
Reference 06220
Rubber protector
Reference 06569
Replacement battery pack (batteries + seals) x10
Reference 06222
Wall mounting bracket (x5)
A L A R M D E V I C E S
11
H E R A L S S P Y R F ®
ACCESSORIES
AND
PERIPHERALS
SPY
RF ®
Real time warning if a problem occurs.> Local warning.> Integrated sound and visual alarm. > Works with an external power supply and supplied with a backup
battery.> Pushbutton for local alarm acknowledgement.> Relay output to trigger remote alarm
(vocal telephonic transmitter …)> Warns SIRIUS software when the battery is low. > Supplied with a wall-mounting bracket.> Operating conditions from -10°C to +70°C.
SPY RF ® AlarMReference 06216
Visualisation of measurements and alarms,(can be used only with SIRIUS Transport).> Real time warning if a problem occurs. > Works with an external power supply and supplied
with backup battery.> Sound and visual alarm. > Rolling measurement display.> Can manage up to 20 SPY RF ® recorders.
SPY RF ® VisuReference 06216
> Warns if a problem occurs.> Works with an external power supply. > Connects directly to SPY RF ® ModeM or to SPY RF ® AlarM.> Audible and visual Alarm .
Audible and visual alarm device
Reference 06570
The GSM ModeM is used with SIRIUS Storage, SIRIUS Transport, and enables SMS messages.
GSM ModeM Reference 00998
The vocal telephonic transmitter is an ideal component for anyalarm installation. In vocal mode it will call from 1 to 4 phonenumbers and inform them clearly on the nature of the incident.Thanks to its vocal help, the VTT is easy to use.> Need a digital telephone line.> Customization of identification, alarms and acknowledgement
of alarms.> Need external power (ref. 04729).
Vocal Telephonic Transmitter (VTT)
Reference 03833
P R O B E S A N D S E N S O R S
12
Technological features of probes The JRI Maxant Metrology service recommends the use of two types of probes in order to ensure accuratemeasurements. The PT100 probe is recognised as the industrial standard. Available in a range of accuracy levels(B, A, 1/3 Din, 1/10 Din).The digital probe stores its gauging coefficient. It makes it interchangeable without any gauging or calibrationconstraints on site. Indeed digital probes are gauged in optimal conditions within our laboratory.All our probes have their binder connector to be connected to the SPY RF ® Recorders.
PT100 ProbesReference 08513 Stainless steel CL.B (� 0,30°C to 0°C), 3 wires, ø5x40 mm, 5cm silicone cable (-50+180°c).
Reference 00967 CL.B (� 0,30°C to 0°C), 3 wires, 3m teflon silicone cable, case ø4x150 mm,Stainless steel handle ø9x100 mm (-50+180 °c).
Reference 00966 Stainless steel CL.B (� 0,30°C to 0°C), 3 wires, ø5x40 mm, 3m silicone cable (-50+180°c).
Reference 08512 Stainless steel CL.B (� 0,30°C to 0°C), 3 wires, ø5x40 mm, 15m silicone cable (-50+180°c).
* No condensing.** Saline or corrosive environment.
PT100 Piercing probe
Reference 00968 Stainless steel ø6x50 mm, CL.B (� 0,30°C to 0°C), 3 wires, 3m teflon/teflon cable (-90+160°c).
PT100 Probe (-80°C)
Reference 08891 Stainless steel ø6X50 mm, 3m cable, 3 wires, interwoven stainless steel & fibreglass (0+400°c).
PT100 High temperature probe
Reference 08511 (� 0,1°C to 0°C), 3 wires, ø3x50mm, 3m cable (-90+250°C).
PT100 1/3 DIN probe
Reference 09520 CL.B (� 0,30°C to 0°C), 3m cable, 3 wires, ø5x15 mm (-50+125°C).
PT100 Flat cable probe
Reference 06556
Reference 08872
(-40+80°C) 3m flat cable, from � 0,5°C on the whole range to � 0,2°C on a smaller range.
(-40+80°C) 50cm flat cable with IP67connector, from � 0,5°C on the whole range to � 0,2°C on a smaller range.
Digital probes
Reference 09471
Reference 09501
(-40+80°C / 0-100% RH*) extension lead available (see page 13).
With protecting coating** (-40+80°C / 0-100% RH*) extension lead available(see page 13).
TH Digital probes
Reference 06621 CL.B (� 0,30°C to 0°C), 3 wires, ø3x18 mm, 2m teflon/teflon cable (-250+150°c).
PT100 Cryogenic probe
A C C E S S O R I E S A N D P E R I P
Didyou know ?
For measurement channels composed of SPY RF ® U recorders associated
with PT100 or digital probes, our metrology laboratory guarantees
the following Maximum Permissive Error :For use across a 35°C temperature
range between the limits of -20 and +40°C : �0.3°C
For use across a 5°C temperature range between the limits of
-20 and +40°C : �0.2°C
For SPY RF ® U
For SPY RF ® N
P R O B E S A C C E S S O R I E S
Reference 05886
TH Transmitter
Reference 05887
RH Transmitter
Reference 08371
∆P Transmitter
Reference 08337
Mounting bracket for CO2 Transmitter
Reference 08991
Reference 08537
TCK Probeø6x400 mm (-200+1100°C), inconel duct, insulated soldering.
Reference 08784 Alerts to mains power supply failure. This sensor links the mainspower supply to the SPY RF ® recorder.When a power supply failure occurs, the DCS sends the informationto SIRIUS software which triggers an alarm.
13
Reference 08873
CO2 Transmitter
Reference 06499 Specially developed sensor to monitor the temperature of sanitary water in pipes (-20+75°C).
Hygitherm TCK probe
Power Supply Failure Detector (DCS)
For digital T probe with IP67 connector for SPY RF ® N.
Reference 06465 For digital TH probe with IP67 connectorfor SPY RF ® TH.
Reference 08874 For digital T probe with IP67 connector for SPY RF ® N.
Référence 09468 For digital TH probe with IP67 connectorfor SPY RF ® TH.
Reference 00949
Universal adaptator(5m) with connector IP67for SPY RF ® N or U.
Wall mounting 2x4-20mA (0 +50°c/0-100% RH*), without power supply, or universal adapter.
Wall mounting 4-20mA (0-100% HR*), without power supply,or universal adapter.
(0 to 20%), � 0.3% + 2% of the reading.Supplied with 1power supply and a 2m cable for SPY RF ® U.
Measurement range from o to � 100 Pa, ABS shell, IP65, 2 visualand sound alarms, requires power of 230 V, and 2 inputs (4-20 mAor 0-10 V), universal adapter to be ordered seperatly.
H E R A L S S P Y R F ®
ACCESSORIES
AND
PERIPHERALS
SPY
RF ®
3 m extension lead
Reference 04729 For transmitters, up to 4 transmitters 4/20 mA or 1 VocalTelephone Transmitter.
Reference 04732
24VDC Power supplyFor transmitters,up to 16 transmitters 4/20 mA.
12VDC Power supply
For SPY RF ® U
For SPY RF ® TC
For SPY RF ® U ou N
12 m extension lead
The benefits of SIRIUS Lite :> Management of several SPY RF ® recorders.> Collects recorded data From SPY RF ® recorders.> Data are secured (not falsifiable).> Displays graphs and tables together with statistics> Data can be exported to Excel.> Does not require a dedicated PC.> Manages alarms via either a dry contact or a SPY RF ®
AlarM device (telephone call, flashing light, buzzer).
SIRIUS Lite, simple mono-user software
JRI Maxant has developed a user friendlysoftware range which enables configurationof an unlimited number of recorders, as wellas management of data and alarms.SIRIUS range is available in 3 versions tomeet your specific needs.
14
R A N G E O F S I R I U S
SIRIUS Storage, advanced software dedicated to storage applications
15
S O F T W A R E
Did you know ?
This system enables data access via Internet,
helping you to react quickly should
a problem occur.
The benefits of SIRIUS Storage compared to Sirius Lite :> Quick overview of the system via a site mapping function.> Enables remote alarms (SMS, e-mail, telephone call, light,
buzzer …).> Programmable task planner: alarm inhibition, upload of data ,
audit trail and alarm report printing, defrost cycles …> Choice of 3 accessibility levels: administrator, batch manager
and user.> Can accept several SPY RF ® ModeM devices.> Capable of monitoring large and distant systems.> Available in mono-user and multi-user versions.> Complies with FDA CFR 21 part 11.
RANGE
OF S
IRIUS
SOFTWARE
16
R A N G E O F S I R I U S
The benefits of SIRIUS Transport compared to Sirius Lite :> Enables access to information while SPY RF ® recorders remain
in vehicle.> Enables configuration of transport data sheet
(type of transport, details of sender and receiver, vehicleregistration, driver name, stages, dates).
> Allows tracing of each delivery step on the graph.> Choice of 2 accessibility levels : administrator and user.> Can accept several SPY RF ® ModeM devices.> Graph annotation function following alarm activation.> Local alarm system.> Allows management of data archives.> Available in mono-user and multi-user versions.
SIRIUS Transport,designed for single or multi step transport applications
Didyou know ?JRI Maxant offers both calibration
software for SPY RF devices ®
and temperature mapping software complying
with the NFX 15140 norm.
Technical features of SIRIUS software Sirius Stockage
Reading last measurement √ √√Upload memory of one or all SPY RF ® recorders √ √√Management of several modems √ √ConfigurationManagement from several PCs √ √Software control panel with site map √
√√√√√√√√√√√√√√
Software control panel without site map √√User and batch managment (CFR 21 Part 11)Upload measurements √√Reading of the last measurement √Inhibition d'alarmeAutomatic printing of reports Defrost cycle management Alarm acknowledgement function including cause of alarmTyping a cause of alarm √SMSE-mailTelephone calls Other (via dry contact) √Audit trail report √Configuration and recording √Archive management √User friendly data transfer (E-mail) √
√ √√√ √√√ √√√ √√√ √√√ √√√ √√√√√√√√√
Mono-user : 06448Multi-user : 06449
Mono-user : 06451Multi-user : 0645206450
√
Sirius TransportSirius LiteRecorder management
Reference
Select the channel to be displayed Zoom and statistics Event displaySecondary scale Super-imposed graphsCursor displayExport pictures to Word Save an archiveValues and statistics Alarm reports Export to Excel
17
S O F T W A R E
SIRIUS Point,Enables gauging of SPY RF ® recorders (except SPY RF ® Nand SPY RF ® C) and printing of gauging certificates.
Reference 06632
Measurements
RANGE
OF S
IRIUS
SOFTWARE
SPY RF ® W I R E L E S S S Y S T E M S
JRI MAXANT SERVICES < Installation
In France and worldwide, various services are offered : on siteradio communication survey, installation, commissioning,IQ/OQ qualification of systems, on site metrology andtraining.
< MetrologyOur metrology laboratory provides : COFRAC-linkedchecking reports, gauging certificates, temperaturemapping reports, as well as calibration certificates fordevices of any brand.(Temperature, relative humidity,CO2, pressure…)
< TrainingJRI Maxant offers different levels of training : technicalmaintenance and metrology, installation and commissioning,use and administration of a wireless system.The JRI Maxant training can be integrated in your annualtraining/education plan.
< Maintenance contract available through your localdistributor● Preventive maintenance.● Corrective maintenance.● Metrology.
18
AS THE DEVICE USES RADIOFREQUENCY, WILL IT AFFECT SENSITIVE ELECTRICAL EQUIPMENT ?
NO : If your electrical equipment is conform to the European norms then theradio frequency waves will not interfere with it.
ARE RADIOFREQUENCY DEVICES SUITABLE FOR A MEDICALENVIRONMENT ?
YES : Radio waves function within the ISM 868 MHz bands(Industrial Scientific and Medical).
ARE RADIOFREQUENCY DEVICES DANGEROUS FOR HUMANS ?
NO : The energy emission of radio frequency devices is very low. It is around40 or 50 times less than that emitted by a mobile phone.
IS THERE A LIMIT TO RADIO WAVE TRANSMISSIONRANGE INSIDE BUILDINGS ?
NO : Modern Radio Frequency technology enables transmissionup to 5 km line of sight. JRI Maxant offers technical solutions to overcome physical obstacles and long distances.
IS IT POSSIBLE TO INSTALLARADIO FREQUENCY SYSTEM IN ANYLOCATION, WITH ANY TYPE OF WALLS ?
YES : We can assure you that radio frequency works everywhere with any type of walls even if they are thick, providing that the installation recommendations are followed.
DOES THE USE OF THESE DEVICESREQUIRE AUTHORISATION ?
NO : You are allowed to use them anywhere because they comply with the European norm ETS 300-220.
ARE MEASUREMENTS DELIVERED BY RADIOFREQUENCY SYSTEMSAS ACCURATE AS THOSE FROM AN ELECTRONIC DEVICE ?
YES : Radio Frequency doesn’t interfere with the measurement, thereforethese devices have the same accuracy as equivalent electronic wire devices.
1
3
5
7
2
4
6
F A Q
19
To make your t raceabi l i ty, our pr ior i ty…
JRI MaxantRue de la VoivreParc d’Activités Technoland - BP 5102725490 FESCHES LE CHÂTEL CEDEX - FRANCE
Ph. : +33(0)3 81 30 68 04Fax : +33(0)3 81 30 60 99www.jri.fr - E-mail : [email protected]
JRI Maxant - Head office : 116, quai de Bezons - BP 20085 - 95101 ARGENTEUIL CEDEX - FRANCES.A.S. 4 000 000 € CAPITAL - R.C.S. PONTOISE 380 332 858
MA
RQ
UE
JAU
NE
Cre
atio
n -
ww
w.m
arqu
e-ja
une.
com
- Ju
ne 2
008.
Top Related