A Q
UALI
TY B
EYO
NDIn
tegr
ated
Con
trol &
Saf
ety
Syst
ems
What we can build for youTotal System Solutions
ECONOMICALSOLUTION
HIGH QUALITYPRODUCT
EXPEDITIOUSDELIVERY
Ensuring total customer satisfaction is the company key objective
• Conventional / Addressable Fire Detection Systems (Fire Alarm Controller / PLC)• Gas Detection System (Gas Detection Controller / PLC)• Abilities to Integrated with Process Control & Safety Systems.• Integrated with Audio Communication Systems.• Integrated with Public Address and General Alarm System.
MODEM
ETHERNET
31 NODES MAXIMUM
RS232
MAXIMUM DISTRBUTIONUP TO 15 LOCAL REPEATERS
ADDRESSABLE DETECTION
LOOP
RS485
TRIPLE IRFLAME
CATALYTICGAS DETECTOR
IR GAS DETECTOR
OXYGEN DETECTOR
UP TO 128 DEVICES
24VDC
CONVERTER
SMOKE DETECTOR HEAT DETCTORSMOKE DETECTOR BREAKGLASS CALL POINT
BREAKGLASS CALL POINT
ONE PAIR TWISTED CABLE CONVENTIONALSMOKE DETECTOR
I.S.
DIGITAL
UP TO 20 DETECTORS
24VDC
FOR INTERFACE OF OTHER EQUIPMENT THROUGH POTENTIAL FREE CONTACTS
CONVENTIONALSMOKE DETECTOR
SMOKE DETECTOR
SOLAR POWEREDGAS DETECTOR
MODEM
PRINTER #2
PRINTER #1
WORKSTATION #2
WORKSTATION #1
WORKSTATION #3
FIRE & GASPANEL
FIRE ALARM PANEL
CONVERTER
PROVIDING TOTAL SOLUTIONS
S A F E T Y TECHNOLOGIESTM
SaTechSYSTEM AUTOMATIONSaTech
SYSTEM AUTOMATION
Fire and Gas SystemPhilosophy
Systems aredesigned to meetthe most stringentrequirements for the industries, such asNFPA requirement, Bureau Veritas standard, Norsok standard, American Bureau of Shipping standard, TÜV certified SIL level, etc. The systems are also designed for use in hazardous andnon-hazardous areas.
Integrated Control & Safety SystemsSystem Integration
TM
Specialist Solutions
PLC: Expertise and experience in logic design and programming combined with proven technology for customized control and/or safety related systems.
SCADA: Solutions range from simple data acquisition and display systems to full monitoring and control functionality for major installations.
White Oil Pipeline Project (WOPP)Pak Arab Pipeline Co. Ltd.
White Tiger Field, MSP-1 Platform"Vietsovpetro" Joint Venture
2
Fire & Gas Detection System
Fire DetectionController
Gas DetectionController
REDUNDANTCONTROLLER
SYSTEM
SYSTEM CONTROLLERSECTION
OUTPUT FOR AUDIBLE& VISUAL DEVICES
FIRE DETECTION SECTIONSMOKE DETECTOR FLAME DETECTOR
ANNUNCIATOR
HEAT DETECTOR CALL POINT
GAS DETECTION &CONTROLLER SECTION
CATALYTICINFRARED
ESD, SHIP/ABANDON VESSEL PUSHBUTTON SHUTDOWN STATION
FROM FIELDPROCESS SYSTEM DCS/ PROCESS F & G SYSTEM
WITH SUITABLE COMMUNICATION LINK TO SHUTDOWN VARIOUS SHIP
EQUIPMANTS
BEACONS STROBE LIGHT
ALARM SOUNDERS
MODBUS
Fire and Gas System is designed to monitor, detect and alert on any possible hazard situation. To achieve this the Fire and Gas System is generally based on two philosophies. The fire detection philosophy is potential fires or fires are first of all prevented from occurring. Any fires are rapidly detected, contained and extinguished. The gas detection philosophy is to detect and indicate continuously the combustible gas accumulation well before it reaches a potentially hazardous level .Upon detection of any hazard situation the Fire and Gas System must first alert the situation to all personnel in the area either by audio or visual. Next, a definite controlled action can be automatically or manually initiated. These actions includes steps to isolate and shut off fuel sources or ignition sources, control or extinguish the fire manually or automatically with help of other systems. For this purpose Fire & Gas system is normally linked to fire fighting equipment such as Fire Water Pump, CO2 release systems, Foam release systems, etc. As the first level of safety precaution, Fire and Gas system must be independent of other systems as such any disturbance in other system will not affect Fire and Gas performance. This requirement has led to various safety level to be considered during design of the system.
We can supply SIL 1, SIL 2 , SIL 3 and Non SIL certified systems. Safety Technologies modular fire and gas system are designed to meet the stringent and demanding specifications required by Refineries, Chemical and Sewage Plants, Power Plants, Process Plants, Offshore Oil and Gas Platforms and Petrochemical Industries. The system is designed to operate and provide a wide range of warning signals involving a variety of fire and gas detectors/ controllers commonly used and approved in the market. Programmable Logic Controllers or SCADA systems are also incorporated to perform control logic, monitoring of multiple system functions, and control of automatic fire extinguishing systems.Safety Technologies is in a position to offer comprehensive systems in which smoke alarm, fire alarm and gas detection equipment are integrated. Our system is designed to meet the strict requirements of the oil and gas industries. It is suitable for use on offshore exploration and production platforms, chemical process plants and power generation plants. The systems are also designed to be used for hazardous areas.
S A F E T Y TECHNOLOGIES TM
S A F E T Y TECHNOLOGIESTM
TM
PROVIDING TOTAL SOLUTIONS
Safety Services
We have a wide range of experience and our innovative use of leading edge technology confirms us as the world's foremost specialist safety service company, offering you one point of contact for all fire and safety requirements.
Fire Protection Systems
We are committed to continuously developing system expertise, design tools and new systems to meet the ever improving industry. We offer complete turnkey packages for all offshore and onshore fire protection and detection requirements.
Areas of expertise: Waterspray systems - medium & high velocity Deluge systems Gaseous extinguishing systems Watermist systems Manual fire fighting systems Integrity Testing
Interface Engineering
We provide design services, installation and commissioning for interface systems between fixed offshore platforms and mobile drilling rigs or vessels.As part of our service, we are prepared to be involved in the project conceptual design and selection process in order to ensure systems compatibility with the fire & gas detection system, fire fighting system, facility layout requirements, public address / General Alarm system, etc…..
3
LCOT MFAP Replacement ProjectSabah Shell Petroleum Co. Ltd
Marine 500 ProjectMarine Drilling Companies Inc
Panyu FPSO ProjectChina National Offshore Oil Corporation
Project References
S A F E T Y TECHNOLOGIES TMPROVIDING TOTAL SOLUTIONS
is an extremely flexible system that is able to provide variable
redundancy from the input modules through one, two or three PLC CPU processors to the output modules. Typical uses of Genius Modular Redundancy technology are applications that require operation on demand—high system availability. These applications include equipment protection, environmental release protection, and Safety critical protection systems, such as: Emergency Shutdown Environmental Protection Systems Boiler/Burner Management Systems Fire and Gas Detection Systems
is reliable, powerful yet flexible Analogue Addressable Fire Alarm Panel. The microprocessor based controller is available in two to eight loops. The panel has user-friendly operator interface and easy to maintain. Conventional and addressable detectors are communicated via 2 wire loops. An LCD display is available for viewing of status and location of detectors. Communication to other instrument can easily be done via RS 232 or RS 485.
provides the high performance microprocessor controller that is easily adapted to any solution required. Its user-friendly programming gives the advantages for immediate understanding and ease to use . ControlLogix can be configured as fully-redundant controller. The architecture provides bumpless switchover and high availability . Selected ControlLogix products are TUV-certified for use in SIL 2 applications . Communications are available in RS 232, RS 485, modbus, ethernet, etc.
Allen-Bradley ControlLogix
Programmable Microprocessor Controllers
Genius Modular Redundancy Genius® Distributed I/O
ControlLogix
FA 1000 Series
Channel Partners – Relationship with OEM’s
FA 1000 Series
GE Fanuc Genius Modular Redundancy& Genius® Distributed I/O
features a flexible and scalable SIL compliant design. 800xA high integrity controllers and I/O (see Figure 6) are highly modular, offering many interconnection options and making them suitable for all safety and business critical process automation applications, from small to large. Through its modular design, AC 800M controllers and associated I/O options contribute to lower costs, higher engineering quality, and higher operating efficiency.
ABB IndustrialIT 800xA
IndustrialITSystem 800xA
4
S A F E T Y TECHNOLOGIES TM PROVIDING TOTAL SOLUTIONS
Addressable Field Devices & Interface
Our services covers a wide area of application as listed below :
Chemical Food and Beverage Mining and Mineral Processing Pulp and Paper Waste and Wastewater Petrochemical Plants Pharmaceutical Plants Aircraft Hangars Sewage Plants, Power Plants, Process Plants Oil and Gas:
Compressors and Pumps Wells and Remote Wells Pipelines Refineries Processing Plants Loading Stations Offshore Oil Rigs Offshore Production Platforms Floating Production Vessels (FPSO)
Application
5
Customized System Components
Detectors and Call Points
The available detectors are microprocessor-based, standalone detectors and controller-based systems for monitoring flammable, toxic and oxygen gas risks. Utilizing the latest ranges of catalytic, pellistor, thermal conductivity, electro chemical point, UV (ultraviolet) and IR (Infrared) principle flame and gas sensor to provide total fire & gas hazard detection. Net-Safety flame and gas detectors certified for use in hazardous location, Manual Alarm Stations, ESD Pushbuttons.
Sounders and Beacons
Selected Horns and Beacons
Selected Smoke and Heat Detectors, Repeater Panel, Mimic Panel, Control Panel, VDU-based Operator, Interface Displays with HMI, Data Transfer Systems, Networking components.
The fire and gas detectors used are robust and require minimum maintenance even in the most arduous conditions.
Net-Safety
MEDC
Notifier, Apollo, Autronica, …
Yodalarm
MEDC
S A F E T Y TECHNOLOGIES TMPROVIDING TOTAL SOLUTIONS
Service, Maintenance, Training, Quality & CustomersWe are committed to a totally integrated Quality Assurance management program, which ensures that design, manufacture, installation, commissioning and life support functions are consistently performed. This is further enhanced by our maintenance and training programs.
Service
Repairs - Refurbishment - Modifications - Operations
Individual customer requirements met through tailored service agreements including on-call response.
Engineering support. Project management. ‘Through-life’ support - customized to meet client’s specification,
time-scale & budget for both new and established installations. ‘Healthcare’ service contracts. Onshore workshop facility.
Training
Systems Training Client support and systems training. Tailor made comprehensive courses. System courses covering:- design philosophy, control
software, system hardware and instrumentation.
Product Training/Familiarization Our professional team explains the use of all equipment
clearly and simply ensuring your staff can operate with confidence.
Practical instruction balanced with required theoretical course content.
Tailored to suit customer requirements.
Maintenance
Our maintenance commitments cover not only routines but can encompass all functions traditionally performed by the client compliance to acceptable level of reliability such as :
• planning maintenance routines,• scheduling work submitting reports,• performance monitoring,• design & consultancy back-up,• spares inventory• providing full technical support.
We ensure compliance of your systems to appropriate legislative standards.
Optimization and retention of the integrity of the system.
Quality Assurance / Health & Safety
A safety management system is in place and we operate in full compliance with all relevant safety legislation.
Risk assessments have been undertaken for all our workshop operations, which incorporate health, safety and environmental controls.
Petroleum Technical Services Company Indorama Petrochem Co Generation Co., Ltd. (coco) PT Chiyoda International Indonesia Pak Arab Pipeline Co. Ltd. China National Offshore Oil Corporation National Petrochemical Public Co. Ltd. National University of Singapore "Vietsovpetro" Joint Venture Marine Drilling Management Company Public Utilities Board, Singapore Sarawak Shell Berhad / Sabah Shell Petroleum Co. Ltd Xiamen Paktank Company, etc…
Customers
Standards & ApprovalsNFPA – National Fire Protection Association.Bureau Veritas – Rules for Classification of Offshore Units.TUV SIL levels, in accordance to IEC 61508 – Functional Safety of electrical / electronic / programmable electronic safety related systems.American Bureau of Shipping – Rules for Building and Classing Steel Vessels. FSS Code – International Code For Fire Safety SystemsIEC 60079 – Electrical Apparatus for Explosive Gas Atmosphere.IEC 60332 – Test on electronic cables under fire condition.
6
S A F E T Y TECHNOLOGIES TM PROVIDING TOTAL SOLUTIONS
7
PUBL
ICAD
DRES
S(P
A / G
A)SY
STEM
BY O
THER
S
SEMI
-SUB
MERS
IBLE
DRI
LLIN
G RI
GFI
RE &
GAS
SYS
TEM
CONF
IGUR
ATIO
N
H2S
GAS
DETE
CTOR
SIEG
ER C
H4
GAS
CONT
ROLL
ER
SIEG
ER H
2S
GAS
CONT
ROLL
ER
FIRE
GUA
RD A
DD
RESS
ABLE
FIRE
CO
NTRO
LLE
R
H2S
GAS
DETE
CTOR
H2S
GAS
DETE
CTOR
H2S
GAS
DETE
CTOR
H2S
GAS
DETE
CTOR
CH4 G
ASDE
TECT
ORCH
4 GAS
DETE
CTOR
CH4 G
ASDE
TECT
ORCH
4 GAS
DETE
CTOR
CH4 G
ASDE
TECT
ORCH
4 GAS
DETE
CTOR
I.S. IO
N SM
OKE
DETE
CTOR
I.S. H
EAT
DETE
CTOR
HEAT
DETE
CTOR
I.S. M
ANUA
L CA
LL P
OINT
I.S. IO
NSM
OKE
DETE
CTOR
MAN
UAL
CALL
POI
NT
MAN
UAL
CALL
POI
NTHE
ATDE
TECT
ORIO
N SM
OKE
DETE
CTOR
HEAT
DETE
CTOR
MAN
UAL
CALL
POI
NT
MAN
UAL
CALL
POI
NTHE
ATDE
TECT
OR
ION
SMOK
EDE
TECT
OR
XENO
NBEA
CON
ALAR
M S
OUND
ERXE
NON
BEAC
ONAL
ARM
SOU
NDER
XENO
N BE
ACON
ALAR
M S
OUND
ER
FIRE
LO
OPS
(4 LO
OPS)
HARD
WIRE
D
HARD
WIRE
D
HARD
WIRE
D
HARD
WIRE
D
FIRE
& G
ASPA
NEL
POW
ER S
UPPL
YW
ITH
BACK
UP F
OR
24 H
OUR
OPR.
OR
1 HOU
R AL
ARM
MARI
NE 5
00 U
PGRA
DEMa
rine D
rilling
Com
panie
s, Inc
.
REPE
ATER
PANE
LHA
RDWI
RED
PROVIDING TOTAL SOLUTIONS
Web
site:
www
.satec
h.co
m.sg
: ste
vena
y@sa
tech
.com.
sg
S A
F E
T Y
TECH
NO
LOG
IES
TM
8
FLOA
TING
PRO
DUCT
ION
STOR
AGE
& OF
FLOA
DING
UNI
T (F
PSO)
FIRE
& G
AS S
YSTE
M CO
NFIG
URAT
ION
OPTI
C SM
OKE
DETE
CTOR
OPTI
C SM
OKE
DETE
CTOR
IP 4
4 MCP
I.S. M
ANUA
L CA
LL P
OINT
I.S.
SMOK
E DE
TECT
ORI.S
. HE
ATDE
TECT
OR
IP 5
6 MCP
IP 5
6 MCP
OPTI
C SM
OKE
DETE
CTOR
HEAT
DE
T EC
TOR
HEAT
DE
T EC
TOR
HEAT
DE
T EC
TOR
IR F
LAM
EDE
TECT
OR
IDC
UNIT
DCU
UNIT
DCU
UNIT
DCU
UNIT
DCU
UNIT
IR G
ASDE
TECT
ORIR
GAS
DETE
CTOR
IR G
ASDE
TECT
ORCA
TALY
TIC
GAS
DETE
CTOR
IR G
ASDE
TECT
ORIR
GAS
DETE
CTOR
DCU
UNIT
DCU
UNIT
IDC
UNIT
IDC
UNIT
IDC
UNIT
FIRE
& G
ASPA
NEL
RS 23
2AU
TRON
ICA
BS 12
/2
DUAL
RS 23
2 / M
ODBU
S
DUAL
RS 23
2 / M
ODBU
S
AUTR
ONIC
A AD
DRES
SABL
EFI
RE C
ONTR
OLLE
R
DET-
TRON
ICS
FLAM
E &
GAS
CONT
ROLL
ER
DET-
TRON
ICS
FLAM
E &
GAS
CONT
ROLL
ER
PUSH
BUTT
ON
PUSH
BUTT
ON
STAT
US LI
GHT
STRO
BE LI
GHT
FIRE
LO
OPS
(14 L
OOPS
)
HARD
WIRE
D
HA
RD
WIR
ED
HARD
WIRE
D
HARD
WIRE
D
HARD
WIRE
DFL
AME &
GA
S LOO
P
FLAM
E &
GAS L
OOP
POW
ER S
UPPL
YW
ITH
BACK
UP F
OR
3 HOU
R OP
R. O
R10
MIN
. ALA
RM
PANY
U FP
SOCh
ina N
ation
al Of
fshor
e Oil C
orpo
ratio
n
IR F
LAM
EDE
TECT
ORIR
FLA
ME
DETE
CTOR
IR F
LAM
EDE
TECT
OR
OPTI
C SM
OKE
DET
ECTO
ROP
TIC
SMOK
EDE
T EC
TOR
IP 4
4 MCP
HEAT
DETE
CTOR
OPTI
C SM
OKE
DET
ECTO
RIO
N SM
OKE
DET
ECTO
R
I.S.
SMOK
E DE
TECT
ORI.S
. ZE
NER
BARR
IER
I.S.
ZENE
R BA
RRIE
R
REPE
ATER
PANE
L
OPER
ATOR
STA
TION
BY O
THER
S
OPER
ATOR
STA
TION
BY O
THER
S
SAFE
TYSH
UTDO
WN
SYST
EM(S
SS)
BY O
THER
S
PROVIDING TOTAL SOLUTIONS
Web
site:
www
.satec
h.co
m.sg
: ste
vena
y@sa
tech
.com.
sg
S A
F E
T Y
TECH
NO
LOG
IES
TM
9
NOTI
FIER
FIRE
CON
TROL
LER
230V
AC 5
0HZ
INPU
T PO
WER
230V
AC 5
0HZ
INPU
T PO
WER
230V
AC 5
0HZ
INPU
T PO
WER
230V
AC 5
0HZ
INPU
T PO
WER
FWP
P-12
01A
STA
RTFW
P P-
1201
A S
TOP
FW
P P-
1201
B S
TART
FWP
P-12
01B
STO
P
FWP
P-12
02
STAR
TFW
P P-
1202
ST
OPFW
P P-
1201
A S
TART
FWP
P-12
01A
SW
ITCH
FWP
P-12
01B
SW
ITCH
FW T
ANK
LOW
LEV
EL
FWP
P-12
01C
STA
RTFW
P P-
1201
C S
TOP
FW P
-120
1 SW
ITCH
SPAR
E
FWP
P-12
01A
STA
RTFW
P P-
1201
A S
TOP
FW
P P-
1201
B S
TART
FWP
P-12
01B
STO
P
BEAC
ON (2
NOS
)SP
ARE
(4)
FWP
P-12
02
STOP
FWP
P-12
01A
STA
RTFW
P P-
1201
A S
TOP
FWP
P-12
01C
STA
RTFW
P P-
1201
C S
TOP
ESD
FIRE
DET
ECTI
ONFI
RE E
SD R
ESET
SPAR
ES
SOUN
DER
INCO
MIN
G PO
WER
SUP
PLY
23OV
AC 50
HZ
EMER
GENC
YSH
UTDO
WN
SYST
EM(E
SD S
YSTE
M)BY
OTH
ERS
SCAD
A SY
STEM
BY O
THER
S
ALLE
N BR
ADLE
Y IN
DUST
RIAL
PC
SPAR
ES
UVIR
FLA
ME
DETE
CTOR
OPER
ATOR
INTE
RFAC
E ST
ATIO
NBY
OTH
ERS
HARD
WIR
ED
CONF
IRM
ED F
IRE
RESE
TSI
LENC
E NO
TIFI
ER
COM
MON
FAU
LT
PANE
LSO
UNDE
R
MOS
AIC
TILE
GR
APHI
C
OIL
PIPE
LINE
FIRE
DET
ECTI
ON S
YSTE
M CO
NFIG
URAT
ION
ALLE
N BR
ADLE
YFI
RE &
GAS
CON
TROL
LER
MAN
UAL
CALL
POI
NT
SPAR
ESSP
ARES
UVIR
FLA
ME
DETE
CTOR
UVIR
FLA
ME
DETE
CTOR
MAN
UAL
CALL
POI
NT
MAN
UAL
CALL
POI
NTM
ANUA
LCA
LL P
OINT
MAN
UAL
CALL
POI
NT
BEAC
ON
RS-4
85 M
ODBU
S RT
U CO
MM
UNIC
ATIO
N
OPTI
C SM
OKE
DETE
CTOR
GATE
WAY
FIRE
LO
OPS
(18 L
OOPS
)
HARD
WIR
ED
RS-4
85 M
ODBU
S RT
U CO
MM
UNIC
ATIO
N
FIRE
& G
AS P
ANEL
POW
ER S
UPPL
YEX
TERN
AL B
ACKU
P BY
OTH
ERS
WHI
TE O
IL PI
PELIN
EPa
k Ara
b Pipe
line
Co. L
td.
OPER
ATOR
INTE
RFAC
E ST
ATIO
NBY
OTH
ERS
OPER
ATOR
INTE
RFAC
E ST
ATIO
NBY
OTH
ERS
OPER
ATOR
INTE
RFAC
E ST
ATIO
NBY
OTH
ERS
MAN
UAL
CALL
POI
NTOP
TIC
SMOK
ED
ETEC
TOR
UVIR
FLA
ME
DETE
CTOR
SOUN
DER
HEAT
DETE
CTOR
ION
SMOK
EDE
TECT
OR
ION
SMOK
EDE
TECT
OR
HEAT
DETE
CTOR
PROVIDING TOTAL SOLUTIONS
Web
site:
www
.satec
h.co
m.sg
: ste
vena
y@sa
tech
.com.
sg
S A
F E
T Y
TECH
NO
LOG
IES
TM
10
COM
BUST
IBLE
GAS
DETE
CTOR
COM
BUST
IBLE
GAS
DETE
CTOR
PURI
FIED
TER
EPHT
HALI
C AC
ID (P
TA)
FIRE
& G
AS S
YSTE
M CO
NFIG
URAT
ION
ENGI
NEER
ING
WOR
KSTA
TION
BUILD
ING
FIRE
ALA
RM P
ANEL
BY O
THER
S
OPEN
PAT
H SM
OKE
DETE
CTOR
FIRE
MAN
UAL
CALL
POI
NTTO
XIC
MAN
UAL
CALL
POI
NT
LOW
OXY
GEN
GAS
DETE
CTOR
COM
BUST
IBLE
GAS
DETE
CTOR
DELU
GE V
ALVE
DELU
GE V
ALVE
TOXI
C XE
NON
BEAC
ONFI
REXE
NON
BEAC
ON
VERS
AMAX
RE
MOT
E CO
NTRO
LLER
FIRE
& G
AS P
ANEL
MAIN
FIR
E &
GAS
PANE
LRE
PEAT
ER P
ANEL
GE F
ANUC
IN
DUST
RIAL
PC
VERS
AMAX
REM
OTE
I/OHA
RDWI
RED
HARD
WIRE
D
HARD
WIRE
D
BUS A
BUS B
ETHE
RNET
MODB
US
GAS
XENO
N BE
ACON
MOTO
RCO
NTRO
LCE
NTRA
L(M
CC)
BY O
THER
S
DIST
RIBU
TED
CONT
ROL
SYST
EM(D
CS)
BY O
THER
S
POW
ER S
UPPL
YW
ITH
BACK
UP F
OR
12 H
OUR
OPR.
OR
30 M
IN. A
LARM
INDO
RAMA
PTA
Indor
ama P
etroc
hem
Limite
d
BUILD
ING
FIRE
ALA
RM P
ANEL
BY O
THER
SBU
ILDIN
GFI
RE A
LARM
PAN
ELBY
OTH
ERS
BUILD
ING
FIRE
ALA
RM P
ANEL
BY O
THER
S
BUILD
ING
FIRE
ALA
RM P
ANEL
BY O
THER
S
GE F
ANUC
IN
DUST
RIAL
PC
PROVIDING TOTAL SOLUTIONS
Web
site:
www
.satec
h.co
m.sg
: ste
vena
y@sa
tech
.com.
sg
S A
F E
T Y
TECH
NO
LOG
IES
TM
Automation, Software and Informations Technology (ASI)'s main accreditation is:Quality and safety especially functional safety including safety management of software and systems (with or without software) and their components (electronic components, measuring and control devices, programmable electronic systems).TÜV Rheinland Group is a European Notified Body, authorized to certify to EU Directives (Machinery, Elevators, Low-Voltage, Pressure equipment, ATEX and EMC) and a Nationally Recognized Test Laboratory (NRTL) accredited by OSHA to certify to UL and other US standards, and by SCC to certify to CSA and other Canadian standards.
Systems, Devices & ComponentsThe automation of technical equipment for safety-related tasks by Programmable Electronic Systems (PES) involves risks. If this equipment fails to function - for example, through technical defects, faulty sequence of events or false human reaction, the environment and technology may well be endangered.Programmable Electronic Systems (PES) used for safety purposes normally consist of input devices (e.g. sensors), programmable electronics and output devices (e.g. actuators). Sufficient measures must be applied in order to keep the risk of a process within tolerable limits. These tolerable limits depend on the application, in accordance with national and international standards for the components of a PES with functional safety. Measures to avoid faults and detect and control failures must be implemented within the PES in order to accomplish functional safety.TÜV Rheinland Group, ASI carries out a type-approval to ensure that the related product includes sufficient functional safety according to the intended Safety Integrity Levels (SIL). TÜV Rheinland Group takes the requirements of national and international standards (IEC 61508, IEC 61511, IEC 62061, EN 954, ISO 13849 etc.) into consideration and ensures the related product's suitability for the intended application area.
11
Technical GuideType Approved Programmable Electronic Systems (PES) (PLC's)
There are considerable restrictions on the use of the PES in safety related applications, especially for the timing restrictions after faults have been detected. These timing restrictions are depending on calculations or applications. Refer to the detailed test reports of the respective TÜV test institute.
Safety Integrity Level AvailabilityRequired
Probability to Failon Demand
Mean TimeBetween Failures
IEC 4 >99.99% E-005 to < E-004 10,000 to 100,000
ISA 3 99.90% E-004 to < E-003 1,000 to 10,000
2 99.00 - 99.90% E-003 to < E-002 100 to 1,000
1 90.00 - 99.00% E-002 to < E-001 10 to 100
Safety Integrity Levels (SIL)SIL and availability are simply statistical representations of the integrity of the system when a process demand occurs. The acceptance of a SIL 1 means that the level of hazard or economic risk is sufficiently low that a system with a 10% chance of failure (90% availability) is acceptable. For example, consider the installation of a SIL 1 system for a high level trip in a liquid tank. The availability of 90% would mean that out of every 10 times that the level reached the high level trip point there would be one predicted failure of the system and subsequent overflow of the tank
SIL 1 2 3 4
TUV Class AK2 AK3 AK4 AK5 AK6 AK7
There is no direct conversion between the AK categories and SIL levels. However in general correlation between SIL and TUV Class are interpreted as follow:
Fault-free system
Degradation 1 Degradation 2 Degradation 3 System structure
2oo4 1oo2 1oo1* Shutdown Safety related and fault tolerant *with time Restriction
2oo4 1oo2 Shutdown Safety related and fault tolerant
1oo3 Shutdown Safety Related
2oo3 1oo2 1oo1* Shutdown Safety related and fault tolerant *with time Restriction
2oo3 1oo2 Shutdown Safety related and fault tolerant
1oo2D 1oo1D Shutdown Safety related and fault tolerant with time Restriction
1oo2 Shutdown Safety Related
2oo2 1oo1 Shutdown Safety related and fault tolerant
1oo1 Shutdown Safety related
Part 4 of the IEC 61508 gives the defintion ofMooN : M out of N channel architecture (for example 1oo2 is 1 out of 2 architecture, where either of the two
channels can perform the safety function)MooND : M out of N channel architecture with diagnostic
Extracted from TÜV Industrie Service GmbH/ last change: 20.03.2004 and other resources
System StructuresThe nomenclature for system structures describes the possible degradation behaviour after fault detection and fault localisation for the central processing units. Variations are possible due to different implementation possibilities. This table shall give a first guideline. In the I/O area different degradation mechanisms are possible and implemented on the different systems.
S A F E T Y TECHNOLOGIES TMPROVIDING TOTAL SOLUTIONS
From our factory in SingaporeWe have developed a worldwide network of distributors, sales and service partners.
Location Exclusive Agents WorldwideBRUNEI
CHINA
INDIA
INDONESIA
JAPAN
KOREA
MALAYSIA
PAKISTAN
THAILAND
UAE
USA
VIETNAM
S. A. Technologies Pte LtdNo.1 Soon Lee Street, # 03-52 Pioneer Centre Building, Singapore 627605Tel: (65) 6561 5671Fax: (65) 6567 0301Email : [email protected] : www.satech.com.sg
Sales & Marketing Connection
Steven Au Yong Skype Name : stevenauyong
HP : +65 9638-2123 [email protected]
Sales Team
TEL: +65 6561-5671 [email protected]
Website : www.satech.com.sgEmail : [email protected]
S.A. TECHNOLOGIES PTE LTDSaTechSYSTEM AUTOMATIONSaTech
SYSTEM AUTOMATION
COPYRIGHT© 2013
SATECH FGS Product Brochure (Ed 050619 0900Hr)Issue 1