WATER TECHNOLOGY
withoutany
chemicals!
EFFICIENTLY SEPERATES YOUR WASTEWATER IN WASTE AND WATER
The MORSELT REDBOX electrocoagulation technology is a simple and highly effective technique for cleaning industrial wastewater, sewage water and surface water. This technology is suitable for removing almost any type of contamination from your wastewater. The purified water is ideal for discharging into the wastewater sewer within the applicable standards or for reuse in the production process.
A cost-saving solution for purifying your wastewater, fully tailored to your wishes.
MORE THAN 30 YEARS OF EXPERIENCE!
WASTEWATER TREATMENT SYSTEMMORSELT REDBOX
WATERTECHNIEK BV
Member of the Group
TEST YOUR WASTEWATER!
Is your waste water suitable for the MORSELT REDBOX? Send us 5 litres of your industrial waste- water and our laboratory will investigate free of charge whether this can be cleaned by REDBOX with-in the environmental standards. We calculate which installation is required and of course what the REDBOX means for your residual waste.
Electrocoagulation is the fusion of dissolved and / or suspended substan-ces by means of electricity. Direct current is applied to an iron anode and cathode reactor plate. The iron plates oxidize to Fe³ + and the water to OH- due to the electricity.
Together these molecules form Fe (OH) ² +, for example. These molecules are positively or negatively charged and therefore poorly soluble in water and as a result attract the waste substances in the water and bind with it. This creates flakes in the water which can be filtered out.
MORSELT REDBOX
Gildestraat 127622 AC Borne
The NetherlandsT +31 74 - 266 11 66
www.morselt.com
00
6/m
orse
lt-sp
alec
k/a
untreatedwaste water
waste waterwith flocs
treatedwaste water
Copy
right
Mor
selt
Wat
erte
chni
ek B
V |
03/
2020
| Su
bjec
t to
prin
ting
err
ors,
tech
nica
l cha
nges
and
err
ors.
ADVANTAGES OF ELECTROCOAGULATION
Treatment without any chemicals
Continuous process
Suitable for every wastewater
Effective for many years
Easy to insert in existing process
Very easy to operate
Fast return of investment
High savings on discharge costs GALVANIC INDUSTRIES
Pollution Units Influent Effluent Reduction
Chrome ( mg/l ) 8 0,03 99%
Phosphate ( mg/l ) 865 2,4 99%
Iron ( mg/l ) 4 1,3 67%
Copper ( mg/l ) 4,1 0,03 98%
Lead ( mg/l ) 0,9 0,3 66%
Minerals ( mg/l ) 74 1 98%
Nickel ( mg/l ) 6 0,3 95%
Tin ( mg/l ) 0,64 < 0,1 84%
Zinc ( mg/l ) 9,4 0,03 99%
Susp. solids ( mg/l ) 86 1 98%
CORRUGATED CARDBOARD
Pollution Units Influent Effluent Reduction
Arsenic ( ug/l ) 4.9 0.5 89%
Cadmium ( ug/l ) 0.6 < 0.1 83%
Chrome ( ug/l ) 62 < 0.5 99%
Cyanide ( ug/l ) 5050 630 87%
Copper ( ug/l ) 22000 25 99%
Lead ( ug/l ) 28 10 64%
Nickel ( ug/l ) 79 18 77%
Silver ( ug/l ) < 40 < 10 75%
Zink ( ug/l ) 780 < 10 98%
METAL INDUSTRIES
Pollution Units Influent Effluent Reduction
Cadmium ( mg/l ) 5.5 < 0.05 99%
Chrome ( mg/l ) 2 < 0.1 95%
COD ( mg/l ) 5600 1900 66%
Iron ( mg/l ) 60 10 83%
Copper ( mg/l ) 17 0.25 98%
Lead ( mg/l ) 220 0.44 99%
Molybdenum ( mg/l ) 1 0.6 40%
Nickel ( mg/l ) 4 0.43 89%
Tin ( mg/l ) 10 < 2 80%
Zink ( mg/l ) 19 0.11 99%