OPC Tunneller
Connection to DeltaV
December 13, 2007
Tunneller Connecting to DeltaV 2
OPC Tunneller Connection to DeltaV
This manual is a product of Matrikon Inc.
Matrikon Inc.
Suite 1800, 10405 Jasper Avenue
Edmonton, AB T5J 3N4
Canada
Phone: 780.448.1010
Fax: 780.448.9191
www.matrikonopc.com
Document Revision History:
Date Document
Version Description Author
2007-12-13 1.0 Initial Document Template BM
Tunneller Connecting to DeltaV 3
SOFTWARE VERSION
Version: 3.0.1.0
DOCUMENT VERSION
Version: 1.0
COPYRIGHT INFORMATION
Copyright 2007, Matrikon Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, translated, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of Matrikon Inc.
CONFIDENTIAL
The information contained herein is confidential and proprietary to Matrikon Inc. It may not be disclosed or transferred, directly or indirectly, to any third party without the explicit written permission of Matrikon Inc.
LIMITATIONS
Matrikon has made its best effort to prepare this manual. Matrikon makes no representation or warranties of any kind with regard to the completeness or accuracy of the contents herein and accepts no liability of any kind including without limitation warranties of merchantable quality, satisfactory quality, merchantability and fitness for a particular purpose on those arising by law, statute, usage of trade, course of dealing or otherwise. Matrikon shall not be liable for any losses or damages of any kind caused or alleged to be caused directly or indirectly from this manual.
LICENSE AGREEMENT
This document and the software described in this document are supplied under a license agreement and may only be used in accordance with the terms of that agreement. Matrikon reserves the right to make any improvements and/or changes to product specifications at any time without notice.
TRADEMARK INFORMATION
The following are either trademarks or registered trademarks of their respective organizations: Matrikon and MatrikonOPC are trademarks or registered trademarks of Matrikon Inc.
OTHER
MatrikonOPC is a division of Matrikon Inc.
Tunneller Connecting to DeltaV 4
Who Should Use This Guide This guide is intended for anyone who is intending to create a connection between OPC Tunneller
and a DeltaV workstations OPC Server.
Overview of Guide This document uses icons to highlight valuable information. Remember these icons and what they
mean, as they will assist you throughout the manual.
This symbol denotes important information that must be
acknowledged.
BOLD
Font displayed in this color and style indicates a hyperlink to the
applicable/associated information within this document, or if
applicable, any external sources.
Introduction
MatrikonOPC Tunneller is an OPC Application that converts a DCOM connection between 2 different
computers and converts it into a TCP/IP stream, to facilitate a connection between a remote client
and a remote server.
Due to the nature of the Tunneller software, there are 2 different setups that will need to be taken
into account. One is the Client-Side configuration, and the second is the Server-Side configuration.
This guide will discuss in detail how to configure both sides of the Tunneller connection so that a
link to a DeltaV Operating system can be established.
Please note that the Username and Password DeltaVAdmin are old
DeltaV defaults. Please substitute as necessary for your system. Also
note that this user name and password are the user name and
password are what are commonly used to log into the DeltaV
computer with.
Please note also that these configuration steps are intended for Windows XP and Windows
2003, with any service packs.
Tunneller Connecting to DeltaV 5
Server Side Configuration
1. Open the Services Configuration Utility, by going to Start -> Run -> services.msc
2. Scroll down to the MatrikonOPC Tunneller SSC
Tunneller Connecting to DeltaV 6
3. Right- Click and hit Properties.
4. Under the Log On Tab select This account and enter in the information for your DeltaV
Administrator. In this example we will use the former defaults of DeltaVAdmin for the
username and password.
Tunneller Connecting to DeltaV 7
5. Once this is done, you will have to restart the service as prompted by Windows.
6. Once you have completed this, the Server side is fully configured, and you will now be able
to move onto the client side configuration of Tunneller.
Tunneller Connecting to DeltaV 8
Client Side Configuration
1. On the Client Side configuration, open the Tunneller GUI from the start menu, as shown
below.
2. Once the configuration Screen is open, simply point the Tunneller CSC at your remote
computer (the DeltaV workstation.)
Tunneller Connecting to DeltaV 9
Once this is done a Tunneller connection to the DeltaV OPC Server on the remote computer may
now be established.
You will see the Remote connection prefaced with a Tunneller: as shown below.
Tunneller Connecting to DeltaV 10
If you have any questions or concerns, please contact MatrikonOPCs Support group at