Dear customer,
SD3 is very proud to introduce our new catalogue to you.New products, new design, fluent explanations and system views have been our leitmotiv for this latest realisation.
You will find inside a synthetic view of how SD3 works and how it has progressed.
This edition has been enriched with an enlarged range of products in order toalways supply the most complete offer in fire alarm systems.
The European standard and CE CPD certifications become more and more essentialto be recognised as a trustful manufacturer. SD3 constantly aims to meet the latestrules and standards to deliver an updated passport certification.
Our factories SEFI and FARE, pillars of SD3, are now in a new modernisedbuilding including cutting-edge manufacturing and logistic processes.
All this organisation enables us to expand our presence on the market and to getyour confidence to build an excellent partnership.
We wish you the best future with SD3.
Bernard MongelliManaging Director
B-03 2011
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:25 Pagina 2
3
1/ CONVENTIONAL SYSTEMS.......................................................................................................................CONVENTIONAL GENERAL VIEW...................................................................................................
A/ PANELS……………...............…………….....................……………………………………..............B/ FIRE DETECTORS………….………………………..........................….....………..…………………..C/ MANUAL CALL POINTS……………………….....................................................................................D/ AIR DUCT DETECTION...............................................................................................................E/ STAND ALONE SMOKE ALARM DETECTOR.....................................................................................F/ LINEAR HEAT DETECTION..........................................................................................................
2/ INTELLIGENT / INTERACTIVE PANELS AND DETECTORS.......................................................................ADDRESSABLE GENERAL VIEW.........................................................................................................
A/ PANELS………………………………………….........................…………………………………………....B/ INTELLIGENT FIRE DETECTORS………………………………..........................………………................C/ ADDRESSABLE MANUAL CALL POINTS……………………….............................................................D/ LOOP SOUNDERS ……………………………………………................................................................E/ INTERFACE LOOP UNITS………………….......................................................................................F/ PROGRAMMING AND MAINTENANCE TOOL……………………........................................................
SPECIFIC PRODUCTS GENERAL VIEW..............................................................................................
3/ LINEAR SMOKE DETECTORS.................................................................................................................
4/ AIR SAMPLING DETECTION...................................................................................................................
5/ EXPLOSION HAZARD AREA PRODUCTS………………………………………...............................................
6/ WIRELESS SOLUTIONS...........................................................................................................................
7/ ACCESSORIES FOR FIRE SYSTEMS…………………………………………….................................................
8/ MONITORING SOFTWARE…………………………………………………….....................................................
9/ HEPHEA POWER SUPPLY RANGE..........................................................................................................
10/ GAS DETECTION…………………………………………………………………..........................................A/ CONVENTIONAL GAS DETECTORS………………….........................................................................5.B/ ADDRESSABLE PANELS……………………………………….........................……................................C/ ADDRESSABLE GAS DETECTORS................................................................................................D/ EXPLOSION PROOF GAS DETECTION.......................................................................................
11/ MARINE...............................................................................................................................................A/ ADDRESSABLE PANELS..................................................................................................................B/ ADDRESSABLE DETECTORS..........................................................................................................
12/ VOICE EVACUATION SYSTEMS………………………………………………...............................................
13/ ELECTRIC LOCK FOR EMERGENCY EXIT DOORS……………………….....................................................14/ FIRE ALARM CABLE................................................................................................................................
15/ MAINTENANCE EQUIPMENT.................................................................................................................A/ TEST AND MOUNTING TOOLS.......................................................................................................B/ SPARE PARTS............................................................................................................................
8-98-9
101214151515
16-1716-17
182122222323
24-25
26
28
29
30
31
33
34
3535363637
383838
39
4040
414142-43
TABLE OF CONTENTS
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:25 Pagina 3
4
SD3 Presentation
THE COMPANY
Founded in 2002, SD3 Security Detection Direct Distribution belongs to the 1st Frenchfire detection systems factories :
- FARE that designs and manufactures the whole range of detectors.
- SEFI that designs and manufactures the whole range of fire alarm panels.
SD3 represents their export department all over the world.
We use the concept of direct delivery from factories, providing flexibility andcompetitivity.
CERTIFICATIONSOur EN54 and CE certification according
to CPD by a notified body is an export passport to build partnerships.
MADE IN FRANCE
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:26 Pagina 4
5
PRODUCTS A complete range for many applications.
SD3 offers a complete range of fire detection products dedicated to:
- Installers specialized in security systems- Distributors with technical assistance- Security systems manufacturers.
As we are a flexible structure directly in contact with factoriesand R&D departments, we are able to meet all your requirements tomatch your market.
Moreover, we are able to customize your products with yourown brand, logo, and language.
SERVICES Reactive and quality services.
Commercial department : our reliable sales team is able toinform and advise you, adapting our offers to each application.
Technical support : our technical support team is able toanswer all your questions and organize trainings all over theworld in order to help you get the right knowledge on the wholeSD3 products range.
Marketing department : our marketing team is ready toprovide you all necessary tools and useful information tointroduce our range in your country.
Logistic support : our professional experts are able to informyou step by step about the logistical process, from your order tothe delivery.
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:26 Pagina 5
6
SD3 ORGANISATION
Created in 1989, FARE is specialised in developing and
manufacturing conventional and addressable detectors.
FARE aims to develop its business through the quality
design and process of its detectors.
FARE owns a tool of modern production, making high
investment in order to ensure a large production
capacity in SMD cabling.
FARE has also its own R&D department able to design
new detectors or customise them for SD3 partners
thanks to a professional and dynamic staff.
FARE CERTIFICATIONS :
ISO / AFNOR / BOSEC / CPD by notified body
SEFI was founded in 1970. The company
manufactures conventional and addressable fire
alarm panels and auxiliaries.
SEFI owns last generation production tool SMD
machines and sophisticated monitoring tests.
SEFI has also its own R&D department.
SEFI CERTIFICATIONS :
ISO / AFNOR / BOSEC / VDS / CPD by notified body
Gas detectors and panels,Power supply Location: Verona ITALY
First French group manufacturer
FIRE ALARM SYSTEMDetectors, Call points, ModulesLocation: FRANCE
Conventional and Intelligent/Addressable panelsLocation: FRANCE
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:26 Pagina 6
7
AccessoriesLocation: Massy (Paris)FRANCE
EXPORT DEPARTMENT Commercial relationshipsTechnical trainingsAssistanceDistribution under the factoriesbrand all over the worldLocation : Massy (Paris) FRANCE
CUSTOMERS
STEM FACTORIES SD3 view of factories and logistic
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:26 Pagina 7
CONVENTIONAL GENERAL VIEW
8
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:26 Pagina 8
9
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:26 Pagina 9
CONVENTIONAL SYSTEMS
2 zones ALPHA 2 Options
PANELS
10
ALPHA 22 ZONES FIRE DETECTION CONVENTIONALPANEL, max 32 detectors and/or MCP perline. Alarm/fault output relays , 1 monitored sounders line + 3 output relays and 1 programmable open collector. Alarm prealarm management. Compact panel not expandable.Needs 2 internal batteries 12V/4Ah
2 WAYS RELAY output module, NO-NC 30V/1A tobe plugged inside ALPHA2 panel
SR2/24
EX4A4
EX4A4ex
DEAG
REP4R
R4P2
From 4 up to 12 zones ALPHA 4/8/12 Options
ALPHA 4/8/12
12 ZONES FIRE DETECTION CONVENTIONALPANEL equipped with 4 zones(max 12 zones) - max 32 detectors and/orMCP per line. Alarm/fault relays,1 monitored sounders line,4 programmable open collectors,1 programmable input.Alarm prealarm/management + Day nightmode. Expandable panel with availibilityof 2 rooms for one or two 4 zones expansion (EX4A4) or one or two Extinguishing boards (DEAG). EN54-2,EN54-4 AFNOR, BOSEC, CE CPD,EN12094-1 with extinguishing board(DEAG). Needs 2 batteries 12V/7Ah
4 ZONES EXPANSION BOARD, max 32 detectorsand/or MCP per line, 1 or 2 EX4A4 boards canbe plugged in ALPHA 4/8/12 and permitsto expand the panel to 8 (with 1xEX4A4) or to12 zones(with 2xEX4A4)
4 ZONES EXPANSION BOARD Ex VERSION to be used with explosion hasard area detectors, max 10 detectors per line, 1 or2xEX4A4ex can be plugged in ALPHA4/8/12 andpermits to include max 8 intrisically detectorzones
1 ZONE EXTINGUISHING EXPANSION BOARD, to be used for management of 1 extinguishingchannel. All monitored lines : Extinguishing actuators, Evacuation panels, Release button,Abort button, Low presssure contact. Thisboard permits to convert ALPHA 4/8/12 panel ina detection-extinguishing panel
4 WAYS RELAY CARD, NO-NC 30V/1A , to beplugged inside the panel, connection by wireswith programmable open collectors of ALPHA 4/8/12
4 WAYS RELAY CARD, NO-NC 30V/1A, to beplugged inside the panel, serial communication,permits to repeat states of the panel on4 relays
R12P2 12 WAYS RELAY CARD, NO-NC 30V/1A, to beplugged inside ALPHA 4/8/12 panel, serial communication, permits to repeat states of thepanel on 12 relays
R7P2 7 WAYS RELAY CARD, NO-NC 30V/1A, to beplugged inside the panel, serial communication, permits to repeat states of thepanel on 7 relays
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:27 Pagina 10
11
CONVENTIONAL SYSTEMS
ALPHA 16/248248 ZONES FIRE DETECTIONCONVENTIONAL PANEL equipped with1 6 z o n e s e x p a n d a b l e t o 2 4 8 -Alphanumeric display 2x16 - Mimicpanel integrated for 32 zones (alarm,fault, disable, test). Max 32 detectorsand/or MCP per line. Alarm/fault relays, 1 monitored sounders line + 3 output relays and 1 programmable opencollector. Alarm prealarm management.Needs 2xbatteries 12V/12Ah
8 ZONES EXPANSION BOARDmax 32 detectors and/or MCP per line, to be plugged inside ALPHA16/248 panel
EX8Z
From 16 up to 248 zones ALPHA 16/248 Options
PANELS
8 WAYS RELAY CARD, NO-NC 30V/1A, to be plugged inside ALPHA16/248 panel,programmable relays, permits to repeat statesof the panel on 8 relays
EX8R
Accessories for panels
TR-SDIREMOTE INDICATOR PANEL with leds and function keys, to repeat general alarm and fault, local test ledsand silence buzzer
TRI 1010 ZONES REMOTE INDICATOR PANEL with leds and function keys, permits to repeat fire alarm zones, local test ledsand silence buzzer
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:27 Pagina 11
CONVENTIONAL SYSTEMS
12
OC05CONVENTIONAL OPTICAL SMOKED E T E C TOR, 1 remote led output,EN54-7, CE according to CPD.
UNIVERSAL BASE WITH STICK ADDRESS SOCKETfor 05-range conventional and addressabledetectors.
S05SE
FIRE DETECTORS
05 range Bases and accessories
TRC05CONVENTIONAL RATE OF RISE + FIXEDHEAT DETECTOR, T° = 62°C, + 9°C/min, 1 remote led output, EN54-5, CE according to CPD.
TSC05-A1SCONVENTIONAL FIXED HEAT DETECTOR, T°= 62°C, 1 remote led output, EN54-5,CE according to CPD.
OC05.12 or OC05.12-ARCONVENTIONAL OPTICAL SMOKEDETECTOR, for 12V security type systems, to be used with R05 relayboard, alarm latched or autoresettable(AR version)
12Vdc application with 05 range
TRC05.12 or TRC05.12-ARCONVENTIONAL RATE OF RISE + FIXEDHEAT DETECTOR, T° = 62°C, + 9°C/min,for 12V security type systems, to beused with R05 relay board, alarm latched or autoresettable (AR version)
TSC05-A1S.12 or TSC05-A1S.12-ARCONVENTIONAL FIXED HEAT DETECTOR, T° = 62°C, for 12V security type systems, to be used with R05 relay board, alarm latched or autoresettable(AR version)
TSC05-BSCONVENTIONAL FIXED HEAT DETECTOR, T°= 75°C, 1 remote led output, EN54-5,CE according to CPD.
TSC05-BS.12 or TSC05-BS.12-ARCONVENTIONAL FIXED HEAT DETECTOR,T° = 75°C, for 12V security type systems,to be used with R05 relay board, alarm latched or autoresettable (AR version)
FLUSHMOUNTING PIECE FOR BASE (Base not included), permits to flushmount a 05range detector.
PES05
BASE WITH INTERNAL SOUNDER 95db @ 1m,Possibility to select 6 tones and 3 intensitivitylevels, EN54-3, CE according to CPD.
SOUND05+S05
RELAY BOARD (12V or 24V) for 05 detectors (to be plugged in S05), NO-NC 30V/1A
R05
PROTECTION PLATE for S05 base, permits tocover a base without detector.
Universal base with GLANDS HOLE for 05range,base for tubes connections.
WATERPROOF universal base with glands for 05range (IP65), base for tubes connectionssupplied with glands
ANTIVANDALISM protection grid
BRI/EM+ S05
BRI + S05
CS05
GAV
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:28 Pagina 12
13
CONVENTIONAL SYSTEMS
MCY2+S95CONVENTIONAL MULTISENSOR (OPTICAL - HEAT) DETECTOR, 1 remote led output, EN54-7 , base included.
IRY2+S95CONVENTIONAL INFRARED FLAME DETECTOR, 1 remote led output, vision cone ± 45°, Distance max 25m, EN54-10,CE according to CPD , base included.
IRY2-IP65CONVENTIONAL INFRARED FLAME DETECTOR, 1 remote led output, vision cone ± 45°, Distance max 25m, EN54-10, CE according to CPD , IP65 box, dim 225x175x80.
SUV+ESCONVENTIONAL ULTRA VIOLET FLAME DETECTOR, 1 remote led output, vision cone ± 60° , radiation analysis rangefrom 80nm to 270nm, base included.
FIRE DETECTORS
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:28 Pagina 13
CONVENTIONAL SYSTEMS
14
DMCL05CONVENTIONAL MANUAL CALL POINTresettable with key without breakingglass, led and alarm resistor integrated,RED colour, EN54-11, CE according toCPD
TRANSPARENT LIFT-UP protective cover for MCP,permits a double action (supplied with protectionlabel)
VPDM
MANUAL CALL POINTS
DMCL05-JCONVENTIONAL MANUAL CALL POINTresettable with key without breakingglass, led and alarm resistor integrated,YELLOW colour
KIT OF 10 RESET KEYS for MCP KCTDM
PLASTIC FRAME for flush mounting MCPPEDM
WATERPROOF IP65 HOUSING BOX for conventionaland addressable manual call point with reset(call point not included)
STS6535
05 range 05 MCP Accessories
DMCL05-BCONVENTIONAL MANUAL CALL POINTresettable with key without breakingglass, led and alarm resistor integrated,BLUE colour
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:28 Pagina 14
15
CONVENTIONAL SYSTEMS
AIR DUCT DETECTION
LINEAR HEAT DETECTION
HC68LINEAR HEAT DETECTION cable 68° (price per meter) connectable directly to conventional panels or addressable modules
HC105LINEAR HEAT DETECTION cable 105° (price per meter) connectable directly to conventional panels or addressable modules
BTG05-P5901AIR DUCT DETECTOR HOUSING for 05 range (detector not included), dimensions 220x186x105mm, IP55
STAND ALONE SMOKE ALARM
VESTADOMESTIC PHOTOELECTRIC SMOKEALARM DETECTOR with 9V battery, CE EN14604 according to CPD
VESTA VESTA Accessories
PLUG IN CARD with NO contact, permits to repeat the state of alarm (for intrusion panels)
DAAF-REL
PLUG IN CARD for 2 wires interconnection, permits to connect one or more VESTA in 2 wires network
DAAF-INTER
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:29 Pagina 15
16
ADDRESSABLE GENERAL VIEW
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:29 Pagina 16
17
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:29 Pagina 17
INTELLIGENT/INTERACTIVE PANELS ANDDETECTORS
From 1 to 128 addresses HEPHAIS 128 Options
PANELS
18
HEPHAIS 128INTELLIGENT/INTERACTIVE COMPACTCONTROL PANEL, 128 ADDRESSES, 2 master loops or 4 spur circuits (opencircuit with max 32 addresses), 99 ZONES, 1000 memory events,1 monitored sounders line+ 5 programmable output relays,1xRS232 serial output for printer orremote control panel, 2 programmableinputs. The panel can be set by keyboardor software. Needs 2 internal batteries12V/7Ah. EN54-2, EN54-4, CE accordingto CPD
7 RELAY CARD, NO-NC 30V/1A, to be plugged inside the panel, serial communication, permitsto repeat states of the panel on 7 relays
R7P2
ALPHA RE
R12P2
C20R
From 1 to 400 addresses HEPHAIS 1600 NE Options
HEPHAIS 1600 NEINTELLIGENT/INTERACTIVE COMPACTCONTROL PANEL, NOT EXPANDABLE,400 ADDRESSES, 2 master loops or 4 spur circuits (open circuit with max 32addresses), 1000 ZONES, 2700 memoryevents, 2 monitored sounders lines +3 programmable output relays, 1xRS232serial output for printer and 1xRS485serial output for remote control panel,4 programmable inputs, RS422 JBUS monitoring output , needs 2 internalbatteries 12V/12Ah. EN54-2, EN54-4,CE according to CPD
REMOTE USER INTERFACE PANEL with serial 485connection, alphanumeric display LCD 160 characters and keyboard
12 RELAY CARD, NO-NC 30V/1A, to be pluggedinside the panel, serial communication, permitsto repeat states of the panel on 12 relays
20 RELAY CARD, NO-NC 30V/1A, to be pluggedinside the panel, serial communication, permitsto repeat states of the panel on 20 relays
R7P2 7 RELAY CARD, NO-NC 30V/1A, to be pluggedinside the panel, serial communication, permitsto repeat states of the panel on 7 relays
SPLITTING MASTER LOOP CARD, permit to splitone loop up to 4 isolated loops to be plugged inside the panel and completed with ICC05 (onefor each split)
TELEHEPHAIS 128 SOFTWARE PROGRAMMING TOOL forHEPHAIS 128, uploading/downloading
12 RELAY CARD, NO-NC 30V/1A, to be pluggedinside the panel, serial communication, permitsto repeat states of the panel on 12 relays
R12P2
REMOTE USER INTERFACE PANEL with serial 485connection, alphanumeric display LCD 160 characters and keyboard
ALPHA RE
TELEHEPHAIS 1600
SOFTWARE PROGRAMMING TOOL forHEPHAIS 1600
X4EVAC 4 MONITORED WAYS SOUNDER CIRCUIT extension board, permits to multiply 1 soundercircuit in 4 activated simultaneously, to beplugged inside the panel
4ISOL
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:30 Pagina 18
19
7 RELAY CARD, NO-NC 30V/1A, to be pluggedinside the panel, ser ial communication,permits to repeat states of the panel on 7relays
R7P2
12 RELAY CARD, NO-NC 30V/1A, to be pluggedinside the panel, serial communication,permits to repeat states of the panel on 12relays
R12P2
INTELLIGENT/INTERACTIVE PANELS ANDDETECTORS
ALPHA RE
MGNET
RF H 1600
From 1 to 1600 addresses HEPHAIS 1600 Options
HEPHAIS 1600-400/L MODULAR INTELLIGENT/INTERACTIVEFIRE CONTROL PANEL MAX 1600POINTS, 16 LOOPS - supplied asstandard for 400 points on 2 masterloops (max 200 addresses / loop) or4 spur circuits, expandable up to7 x MG2B (loop boards), EN54-2,EN 54-4, in large box with integratedfront panel, 1000 zones,2700 memory events, 2 monitoredsounders lines + 3 programmableoutput relays, 1xRS232 serial outputfor printer and 1xRS485 serial outputfor remote control panel,4 programmable inputs, RS422 JBUSmonitoring output,networkable with MGNET board. Needs 2 internal batteries 12V/17Ah. EN54-2, EN54-4,CE according to CPD
REMOTE USER INTERFACE PANEL with serialconnection, alphanumeric display LCD 160characters and keyboard
NETWORK CARD, must be plugged in eachpanel for network application, network donewith RS485 redundant connection
USER INTERFACE FRONT PANEL ( c o m m a n da n d c o n t r o l ) w i t h alphanumeric display160 characters and keyboard, 19 inches, 3U,can be integrated in cabinet or in CO3U console
MG2B EXTENSION MODULE 2 LOOPS (max 200 pointsper loop) or 4 spur circuits (max 32 points percircuit) to be plugged inside the panel
CO3U PLASTIC BOX CONSOLE for RFH 1600 frontpanel
HEPHAIS 1600-400/SMODULAR INTELLIGENT/INTERACTIVEFIRE CONTROL PANEL MAX 1600POINTS, 16 LOOPS - supplied as standard for 400 points on 2 masterloops (max 200 addresses/loop)or 4 spur circuits, expandable up to7 x MG2B (loop boards), EN54-2, EN 54-4, in small box with integratedfront panel, 1000 Zones,2700 memory events, 2 monitored
sounders lines + 3 programmableoutput relays, 1xRS232 serial outputfor printer and 1xRS485 serial outputfor remote control panel,4 programmable inputs, RS422 JBUSmonitoring output , networkable with MGNET board.Needs 2 internal batteries 12V/12Ah.EN54-2, EN54-4,CE according to CPD
PANELS
IE2M IE2M is an extension board with connectors allowing to connect from 2 to 4 MG2B. Thisboard permits to expand the panel from 10 to16 loops. Necessary if more than 10 loops needed.
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:30 Pagina 19
HEPHAIS 1600-400/L BBMODULAR INTELLIGENT/INTERACTIVEFIRE CONTROL PANEL MAX 1600POINTS, 16 LOOPS - supplied as standardfor 400 points on 2 master loops (max200 addresses/loop) or 4 spur circuits, expandable up to 7 x MG2B (loop boards),EN54-2, EN 54-4, in large boxwithout front panel, 1000 Zones, 2700memory events, 2 monitoredsounders lines + 3 programmable outputrelays, 1xRS232 serial output for printer
and 1xRS485 serial output for remotecontrol panel, 4 programmable inputs,RS422 JBUS monitoring output,networkable with MGNET board. Needs2 internal batteries 12V/17Ah. EN54-2,EN54-4, CE according to CPD
From 1 to 1600 addresses
INTELLIGENT/INTERACTIVE PANELS ANDDETECTORS
PANELS
20
HEPHAIS 1600-400/S BBMODULAR INTELLIGENT/INTERACTIVEFIRE CONTROL PANEL MAX 1600 POINTS,16 LOOPS - supplied as standard for 400points on 2 master loops (max 200 addresses/loop) or 4 spur circuits,expandable up to 7 x MG2B (loop boards),EN54-2, EN 54-4, in small box withoutfront panel, 1000 Zones, 2700 memoryevents, 2 monitored sounders lines +3 programmable output relays, 1xRS232serial output for printer and 1xRS485 serial output for remote control panel,4 programmable inputs, RS422 JBUSmonitoring output, networkable withMGNET board. Needs 2 internalbatteries 12V/12Ah. EN54-2, EN54-4, CE according to CPD
HEPHAIS 1600-400 LPMMODULAR INTELLIGENT/INTERACTIVEFIRE CONTROL PANEL MAX 1600 POINTS,16 LOOPS - supplied as standard for 400points on 2 master loops (max 200adresses/loop) or 4 spur circuits, expandable up to 7 x MG2B (loop boards),EN54-2, EN 54-4, in large metall icwith integrated front panel, 1000Zones, 2700 memory events, 2 monitoredsounders lines + 3 programmableoutput relays, 1xRS232 serial output forprinter and 1xRS485 serial output forremote control panel, 4 programmableinputs, RS422 JBUS monitoring output,networkable with MGNET board. Needs 2internal batteries 12V/17Ah. EN54-2,EN54-4, CE according to CPD
TELEHEPHAIS 1600SOFTWARE PROGRAMMING TOOL forHEPHAIS 1600
20 RELAY CARD, NO-NC 30V/1A, to be pluggedinside the panel, serial communication, permits torepeat states of the panel on 20 relays
C20R
4 MONITORED WAYS SOUNDER CIRCUITextension board, permits to multiply 1sounder circuit in 4 activated simultaneously,to be plugged inside the panel
X4EVAC
INTERNAL SERIAL FLUSH MOUNTED PRINTERcan be directly mounted in metallic box ofHEPHAIS 1600 or through SUPIMP piece forplastic box
IMP
MOUNTING KIT to flushmount IMP printer inLARGE PLASTIC box of HEPHAIS 1600
SUPIMP
EXTERNAL SERIAL PRINTER, dimensions165x135x50mm
IMP/E
PACK OF 10 THERMIC PAPER ROLLSKCT10
SPLITTING MASTER LOOP CARD, permits tosplit one loop up to 4 isolated loops to be plugged inside the panel and completed withICC05 (one for each split)
4ISOL
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:31 Pagina 20
21
INTELLIGENT/INTERACTIVE PANELS ANDDETECTORS
OA05INTELLIGENT/INTERACTIVE OPTICALSMOKE DETECTOR, microprocessorbased, 1 programmable remote alarmindicator output, 8 levels sensitivity setting, EN54-7 CE according to CPD
INTELLIGENT FIRE DETECTORS
05 range Bases
TA05INTELLIGENT/INTERACTIVE HEATDETECTOR, static or/and rate of rise,microprocessor based ,1 programmable remote alarmindicator output, 6 levels sensitivity setting, EN54-5, CE according to CPD
MA05INTELLIGENT/INTERACTIVEOPTICAL-HEAT DETECTOR, multicriteriaor combined, microprocessor based,1 programmable remote alarm indicator output, 8 levels sensitivity setting, EN54-7, CE according to CPD
IR95+S95ANALOGUE/ADDRESSABLE INFRARED FLAME DETECTOR, microprocessor based, 1 programmable remote alarm indicator output, EN54-10 CE according to CPD
Addressable flame detector
UNIVERSAL BASE WITH STICK ADDRESS SOCKETfor 05-range conventional and addressabledetectors
S05SE
PLUG IN ISOLATOR BOARD for 05 detectors (to be plugged in S05SE)
ICC05
SOUND05+S05
PLUG IN CONNECTION BOARD for cable ≥ 1,5mm2 (to be plugged in S05SE)
STRAPP
Universal base with GLANDS HOLE for 05range, base with tubes connections
RELAY BOARD (12V or 24V) for 05 detectors(to be plugged in S05), NO-NC 30V/1A
PROTECTION PLATE for S05 base, permits tocover a base without detector
WATERPROOF universal base with glands for05 range (IP65), base with tubes connections supplied with glands
CS05
BRI/EM+ S05
BRI + S05
ANTIVANDALISM protection grid GAV
BASE WITH INTERNAL SOUNDER 95db @ 1m,Possibility to select 6 tones and 3 intensitivitylevels, EN54-3, CE according to CPD.
R05
FLUSHMOUNTING PIECE FOR BASE (Base not included), permits to flushmount a 05range detector.
PES05
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:32 Pagina 21
22
INTELLIGENT/INTERACTIVE PANELS ANDDETECTORS
DMA05ADDRESSABLE MANUAL CALL POINT resettable with key without breakingglass, integrated isolator, red colour,EN54-11, EN54-17, CE according to CPD
DMA05RADDRESSABLE MANUAL CALL POINT resettable with key without breakingglass, integrated isolator and programmable relay output, redcolour, EN54-11, EN54-17,EN54-18 CE according to CPD
AVSA05/WADDRESSABLE HIGH POWERED PIEZOELECTRIC SOUNDER for indoor use (white colour), integrated isolator, possibility to select 6 tones, 95db@1m, lateral hearings, loop powered, for HEPHAIS range
AVSA05/RADDRESSABLE HIGH POWERED PIEZOELECTRIC SOUNDER for indoor use (red colour), integrated isolator, possibility toselect 6 tones, 95db@1m, lateral hearings, loop powered, for HEPHAIS range
TRANSPARENT LIFT-UP protective cover for MCP,permits a double action
VPDM
PLASTIC FRAME for flush mounting MCPPEDM
KIT OF 10 RESET KEYS for 05 MCP KCTDM
LOOP SOUNDERS
05 range Accessories
Addressable waterproof manual call point
STS6535WATERPROOF IP65 HOUSING BOX for conventional and addressable manual call point with reset (call point not included)
ADDRESSABLE MANUAL CALL POINTS
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:32 Pagina 22
23
INTELLIGENT/INTERACTIVE PANELS AND DETECTORS
INTERFACE LOOP UNITS
MAY1ADDRESSABLE ZONE INTERFACE MODULE with backbox, for max 32 conventional points
MBA95ADDRESSABLE ZONE INTERFACE MODULE with backbox, for max 32 conventional points, isolator integrated,opto-isolated on the secondary line, EN54-17, EN54-18, EN54-13 CE according to CPD
ETC05-BADDRESSABLE INPUT/OUTPUT MODULE with backbox, isolator integrated, NO or NC monitoring for input , relay output NO-NC 30V/1A, EN54-17, EN54-18 CE according to CPD (exists also in RAIL DIN version)
ET4C05-BADDRESSABLE 4 INPUT/OUTPUT MODULE with backbox, isolator integrated, NO or NC monitoring for input , relayoutput NO-NC 30V/1A, EN54-17, EN54-18 CE according to CPD
EDLADDRESSABLE 2 MONITORED INPUT + 1 MONITORED LINE OUTPUT permits to manage 2 monitored inputs anduse monitored sounders line for outputs, EN54-17, EN54-18, CE according to CPD
IAT16R/DADDRESSABLE 16 OUTPUT RELAY MODULE on rail din, relay output NO-NC 30V/1A
IAT16E/DADDRESSABLE 16 MONITORED INPUT MODULE on rail din
PROGRAMMING AND MAINTENANCE TOOL
MINIBT05Portable tool for programming / test / maintenance of detectors and addressable devices (for 05 range)
ED4LADDRESSABLE 8 MONITORED INPUT + 4 MONITORED LINE OUTPUT permits to manage 8 monitored inputs anduse monitored sounders line for outputs, EN54-17, EN54-18, CE according to CPD
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 16:21 Pagina 23
24
SPECIFIC PRODUCTS GENERAL VIEW
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:33 Pagina 24
25
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:33 Pagina 25
LINEAR SMOKE DETECTORS
26
DLFBe IINTELLIGENT INTERACTIVE BEAM DETECTOR (loop powered) for linearsmoke detection supplied with reflectorfor distance from 3 up to 100 meters, integrated isolator, visible ray for alignment, EN54-12, CE according to CPD
DLFB Accessories
DLFBe CCONVENTIONAL BEAM DETECTOR, 2 wires(line powered) for linear smokedetection supplied with reflector for distance from 3 up to 100 meters, visible ray for alignment, EN54-12, CE according to CPD
DLFBe RRELAY BEAM DETECTOR, for linearsmoke detection supplied with reflectorfor distance from 3 up to 100 meters, NO-NC ALARM, NO-NC FAULT, visible rayfor alignment, EN54-12, CE accordingto CPD
DFA05-1C-BCONVENTIONAL SINGLE CHANNEL HIGH SENSITIVITY BASE DETECTOR for one samplingtube with smoke level indicator, to be completed with one detector module SSD,EN54-20 CE according to CPD
DFA05-2C-BCONVENTIONAL DUAL CHANNEL HIGH SENSITIVITY BASE DETECTOR , for one or twosampling tubes with smoke level indicator, to be completed with one or two detectorsmodules SSD, EN54-20 CE according to CPD
DFA05-1CINTELLIGENT/INTERACTIVE SINGLE CHANNELHIGH SENSITIVITY BASE DETECTOR , for onesampling tube, to be completed with one detector module SSD, EN54-20 CE accordingto CPD
DFA05-2CINTELLIGENT/INTERACTIVE DUAL CHANNELHIGH SENSITIVITY BASE DETECTOR , for one ortwo sampling tubes, to be completed with oneor two detectors modules SSD, EN54-20 CEaccording to CPD
WITH HIGH SENSITIVITY DETECTORS Detector modules
REMOTE CONTROL WITH DISPLAY AND KEYPADfor DLFBe, permits to adjust the alignment andprogram the beam
DETTEL
REMOTE BOX FOR BEAM, permits remotely to enable/disable, reset, can be plugged on the remote control DETTEL, 4 wires connections tothe beam
BEAM-BR
HIGH SENSITIVITY SMOKE DETECTOR MODULEwith alarm sensitivity range from 0,01%/m to10%/m to be plugged in DFA05
HIGH SENSITIVITY SMOKE DETECTOR MODULEwith alarm sensitivity range from 0,002%/m to10%/m to be plugged in DFA05
SUNSHIELD PROTECT FOR REFLECTOR, suppliedfor 4 reflectors 10x10 reflectors, permits toprotect against sun rays
BEAM-KIT4CC
RELAY INTERFACE MODULE with 5 programmablerelays, NO-NC 30V/1A to be plugged in DFA05
RIM35
SD-1GO MEMORY CARD MODULE to be pluggedin DFA05 permits to record operating data andstore memory events
MCM35
AIR SAMPLING DETECTION
SSD 535-3
SSD 535-2
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:33 Pagina 26
27
AIR SAMPLING DETECTION
SAMPLING PIPE CONFIGSYSTEM DESIGN SOFTWARE permits to define the network pipe
DFA05 CONFIGPROGRAMMING SOFTWARE permits to download/upload data configuration through USB cable (not supplied)
PROGRAMMING SOFTWARE FOR DFA05
TP2SFIRE LOCALISATION DEVICE HEAD ,this device connected to aspiratingpipe with high sensitive detector(DFA05) permits to address the airsampling point(s). Detector withdouble detection, led integrated P65.To be completed with SP2S
SP2SFILE LOCALISATION DEVICE BASE forwire connection to the fire alarm paneland connection for the aspiratingtype.IP65.To be completed with TP2S
FIRE LOCALISATION DEVICE Options
RELAY BOARD (12V or 24V) for 05 detectors (to be plugged in S05), NO-NC 30V/1A
R05
Filter mat-SFilter Mat Small for FBS 25 PC
FBL 25PCFilter Box Large Ø 25 mm, PC
FBS 25PCFilter Box Small Ø 25 mm, PC
Filter mat-LFilter Mat Small for FBS 25 PC
MV 25 ABSManual ball valve Ø 25 mm, ABS
FILTERS
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:34 Pagina 27
28
ASPIRATING PIPES
AIR SAMPLING DETECTION
TU25RFFIREPROOF AIR SAMPLING PIPE 25mm(3m length), red colour (Qmin =30)
EN25RFFIREPROOF STRAIGHT SOCKET 25mm,red colour, (Qmin =20)
TE25RFFIREPROOF EQUAL TEE PIECE for 25mmtube, red colour, (Qmin =10)
T 25/8FIREPROOF EQUAL TEE PIECE for 8mmcapillary tube or sample point, red co-lour, (Qmin =10)
TT25RFFIREPROOF END CAP, for 25mm tube ,red colour, (Qmin =10)
C90RFFIRE PROOF 90° ELBOW, for 25mm tube,red colour, (Qmin =5)
CF70FLEXIBLE ELBOW for 25mm tube,(Qmin =4)
C45RFFIRE PROOF 45° ELBOW, for 25mm tube,red colour, (Qmin =5)
TF.10FLEXIBLE TUBE 1m length
TC.8CAPILLARY TUBE (10mm OD; 8mm ID)(100m roll)
ABRFIRE PROOF PIPE CLIP for 25mm tube, redcolour, (Qmin =50)
UTRFFIREPROOF UNION TUBE for 25mm tube, redcolour, (Qmin =10)
PMTUSAMPLE POINT 8mm
PMCCONIC SAMPLE POINT, (Qmin =10)
PMPTPLATE SAMPLE POINT vith nut, (Qmin =10)
PMPPLATE SAMPLE POINT vith screws, (Qmin =10)
PMC/8SAMPLE POINT for capillary tube, (Qmin =10)
PCM/10RAISE FOR CLIP , raises for 17mm, (Qmin =10)
PRPMEXTENSION LEAD for sample point, (Qmin =10)
TLWATERPROOF ENDCAP, (Qmin =10)
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:35 Pagina 28
29
EXPLOSION HAZARD AREA PRODUCTS
VTEXCONVENTIONAL RATE OF RISE + FIXED HEAT DETECTOR, Ex version, ATEX II 1G Eex ia IIC T6, EN54-5
SVEXMOUNTING BASE- anti-static design - Ex version
DMEXCONVENTIONAL MANUAL CALL POINT with reset key , Ex version
AVSEXINTRISICALLY SAFE SOUNDER-EX- 100db, to be used with SBEX BZ3
MBA95ExADDRESSABLE ZONE INTRISICALLY INTERFACE MODULE with backbox, for max 10 conventional EEX points, isolatorintegrated, opto-isolated on the secondary line, EN54-17, EN54-18, EN54-13 CE according to CPD
SBEX BZ1SAFETY BARRIER dedicated for intrisically safe detectors and call points
SBEX BZ3SAFETY BARRIER dedicated exclusively for intrisically safe sounders
VIREXCONVENTIONAL INFRARED FLAME DETECTOR - Ex version, ATEX II 1G Eex ia IIC T6, EN54-10
VOEXCONVENTIONAL OPTICAL SMOKE DETECTOR - Ex version, ATEX II 1G Eex ia IIC T6 EN54-7
SBEX BZ2SAFETY BARRIER dedicated for intrisically safe detectors and call points, opto-isolated
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:35 Pagina 29
30
WIRELESS SOLUTIONS
OA05-WWIRELESS OPTICAL SMOKE DETECTOR, 1 remote led output, EN54-7 , EN54-25, CE according to CPD
DMA05-WWIRELESS MANUAL CALL POINT, EN54-11 , EN54-25, CE according to CPD
OI05MONITORING MODULE can be connected on HEPHAIS 1600 ,1 remote led output, monitoring device of wireless equipments EN54-17, EN54-18, EN54-25, CE according to CPD
TELEWIRELESSSOFTWARE PROGRAMMING TOOL for WIRELESS SOLUTIONS
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:35 Pagina 30
31
ACCESSORIES FOR FIRE SYSTEMS
IND05REMOTE ALARM INDICATOR angle of vision = 180°
AVS 2000/WHIGH POWERED PIEZOELECTRIC SOUNDER for INDOOR use (white colour), possibility to select 6 tones, lateralhearings, 95db@1m, EN54-3 according to CPD
AVS 2000/RHIGH POWERED PIEZOELECTRIC SOUNDER for INDOOR use (red colour), possibility to select 6 tones, 95db@1m,lateral hearings, EN54-3 according to CPD
AVSU EFPHIGH POWERED PIEZOELECTRIC SOUNDER for OUTDOOR , 114db@1m, IP65, EN 54-3 according to CPD
AVS2000FLASHCOMBINED SOUNDER AND FLASH for INDOOR use, 95db@1m, EN54-3 according to CPD
AVSFLASHXENON BEACON high luminosity with 360° angle ,from 12Vdc to 48Vdc
4485COMBINED SOUNDER AND FLASH for OUTDOOR use (red colour), IP65, 101db@1m, EN54-3 according to CPD
531024-1019XENON OUTDOOR BEACON high luminosity with 360° angle ,from 9Vdc to 60Vcc, IP65
P7232OPTICAL ACOUSTIC ALARM PANEL WITHBUZZER lighting with high luminosity LED,12V/24Vdc, IP55
P7236SELF-POWERED OPTICAL ACOUSTIC ALARM PANEL WITHBUZZER lighting with high luminosity LED, 12V/24Vdc,IP55
IND05EWATERPROOF REMOTE ALARM INDICATOR angle of vision = 180°
P7264OPTICAL ACOUSTIC ALARM PANEL WITHSOUNDER, lighting with high luminosity LEDIP55
P7265OPTICAL ACOUSTIC ALARM PANEL WITH SOUNDER, lighting with high luminosity LED, 12V/24Vdc, IP43
P7260OPTICAL ACOUSTIC ALARM PANEL WITH SOUNDER, lighting with high luminosity LED, 12V/24Vdc, IP65
P7266SELF-POWERED OPTICAL ACOUSTIC ALARM PANEL WITHSOUNDER, lighting with high luminosity LED IP55
S/EKO F24SELF POWERED OUTDOOR SOUNDER WITH FLASH, IP34, 24 Vdc
P7268SELF-POWERED OPTICAL ACOUSTIC ALARM PANEL WITH SOUNDER, lighting with high luminosity LED IP43
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:36 Pagina 31
ACCESSORIES FOR FIRE SYSTEMS
32
ALTO-DA1B00XINFORMATION AND DIRECTION LIGHTING, IP40, sustained double sided 3 hours, wall mounted (exists also ceilingmounted) , operating voltage 230VAC/50hz, IP40
MARINA-DA3B0XEMERGENCY LIGHT NON-MAINTAINED SINGLE SIDED 3 hours (exists also in sustained), IP65, operating voltage230VAC/50HZ
FENER-2210107XEMERGENCY LIGHT 1 hour (exists also in 3 hours), 2 halogen lamps 20W (exists also with 1), 12V 7Ah battery
VTR0241210ELECTROMAGNETIC DOOR release unit in metal case, 50daN, 24V
1360ELECTROMAGNETIC DOOR release unit in metal case, 100daN, 24V
1388AELECTROMAGNETIC DOOR release unit in metal case, 300kg/250daN, 24V
1450FLOODING AND MOISTURE DETECTOR with free voltage contact relay, 12/24Vdc
2450IP 67 LIQUID DETECTOR with free voltage contact relay, 12/24Vdc
DA4PHONE DIALER with 4 inputs and 4 voice messages
GSM 31 GPRSGSM/GPRS communicator (with metal enclosure, GSM antenna and power supply)
USB/232CONVERTER MODULE USB/232
4476-24RED INTERNAL BELL, diameter 150mm, 93 db, 24Vdc
4479-24RED EXTERNAL BELL, 6 inches diameter ,93 db, 24Vdc
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:36 Pagina 32
33
MONITORING SOFTWARE
JBUS/IPTCPIP INTERFACE for analogue panels (MA53 422/232converter + Procontroller 232/TCPIP converter)
JBUS/IP/4TCPIP interface for 4 analogue panels (MA53 422/232converter + Procontroller 232/TCPIP converter)
MA53CONVERTER MODULE RS232/RS422 with power supply
CONCUFICONVERTER MODULE RS422/RS485/RS232 to optic fiber max distance 6km, multimode, rail din enclosure, 7Vdc to60Vdc power
MAPSKITALPHA-HEPHAISBASE REMOTE MAP MONITORING SOFTWARE for 8 panels(to be completed with MAPSPLUS),compatible with addressableALPHA 500/1000 or HEPHAIS 1600 panels
NET VERSION BASE REMOTE MAP MONITORING SOFTWARE (to be completed with MAPSPLUSALPHANET),compatible with addressableALPHA 500/1000 or HEPHAIS 1600 panels
MAPSKITALPHA-HEPHAIS NET
MAPSKITALPHA-HEPHAIS Options
NET VERSION ADDITIONAL LICENSE for management of 1 panel,compatible with addressable ALPHA 500/1000 or HEPHAIS 1600 panels
MAPSPLUSALPHA-HEPHAIS NET
ADDITIONAL LICENSE for 1 panel management, compatiblewith addressable ALPHA 500/1000 or HEPHAIS 1600 panels
MAPSPLUSALPHA-HEPHAIS
NET VERSION ADDITIONAL LICENSE for management of 4 panels,compatible with addressable ALPHA 500/1000 or HEPHAIS 1600panels
MAPSPLUSALPHA-HEPHAIS NET4
CONVERTERS
Optic fiber converter
Serial converter
MAPSKITALPHA-HEPHAIS FOR NETWORK Options
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:37 Pagina 33
HEPHEA POWER SUPPLY RANGE
34
RACK VERSION
HEPHEA 242POWER SUPPLY IN BOX 24V-2A, including output relays for mains fault and battery fault, metallic box405x385x160mm, EN54-4 (A2), CE according to CPD
HEPHEA 244POWER SUPPLY IN BOX 24V-4A, including output relays for mains fault and battery fault, metallic box405x385x160mm, EN54-4 (A2), CE according to CPD
AL124H-CP01POWER SUPPLY IN PLASTIC BOX 24V-1A, including output relays for mains fault and battery fault
AL424H-CM01EPOWER SUPPLY IN METALLIC BOX 24V-4A, 265x405x140mm, including output relays for mains fault and battery fault
AU224/A2/RPOWER SUPPLY IN RACK VERSION 24V-2A, including output relays for mains fault and battery fault, 19inches, 3U
AU424/A2/RPOWER SUPPLY IN RACK VERSION 24V-4A, including output relays for mains fault and battery fault, 19inches, 3U
AL1024B-CM03POWER SUPPLY IN METALLIC BOX 24V-10A, 405x390x165mm, including output relays for mains fault and batteryfault
HEPHEA 248POWER SUPPLY IN BOX 24V-8A, including output relays for mains fault and battery fault, metallic box405x385x160mm, EN54-4 (A2), CE according to CPD
HEPHEA 2412POWER SUPPLY IN BOX 24V-12A, including output relays for mains fault and battery fault, metallic box405x385x160mm, EN54-4 (A2), CE according to CPD
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:37 Pagina 34
35
GAS DETECTION
GD104CCONVENTIONAL HYDROGENE GAS DETECTOR, H2, IP55, alarm and prealarm resistors integrated, needs external power supply
GD105CCONVENTIONAL LIQUID PROPANE GAS DETECTOR, LPG, IP55, alarm and prealarmresistors integrated, needs external powersupply
METHANE GAS TEST BOTTLE , 40% L.I.E, 12 litersMEGAS
GD100CCONVENTIONAL METHANE GAS DETECTOR,CH4, IP55, can be directly connected onALPHA panel, alarm and prealarm resistors integrated, needs external power supply
GD102CCONVENTIONAL PETROL STEAM GAS DETECTOR, IP55, can be directly connectedon ALPHA panel, alarm and prealarm resistors integrated, needs external power supply
TEST KIT GAS DETECTORS (valve + adapter)P7150V
PLUG-IN 3 RELAY CARD, NO-NC 30V/1A , to beplugged inside the detector, permits to repeatALARM, PREALARM, FAULT of the detector
GDREL
CONVENTIONAL GAS DETECTORS Accessories
REMOTE CONTROL WITH DISPLAY AND KEYPADfor GAS DETECTORS, permits to read level anddata of detectors (sensitivity, thresholds…)
DETTEL
CARBON MONOXIDE GAS TEST BOTTLE, 250ppm,12 liters
COGASGD106CCONVENTIONAL PROPANE GAS DETECTOR,C3H8, IP55, alarm and prealarm resistors integrated, needs external power supply
GD109CCONVENTIONAL ACETILENE GAS DETECTOR,C2H2, IP55, alarm and prealarm resistors integrated, needs external power supply
PETROL STEAM GAS TEST BOTTLE , 40% L.I.E, 12 liters
VPGAS
GD113CCONVENTIONAL CARBON MONOXIDE GASDETECTOR, CO, IP55, ELECTROCHEMICALCELL, alarm and prealarm resistors integrated,needs external power supply
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:42 Pagina 35
GAS DETECTION
36
ADDRESSABLE GAS DETECTORS Accessories
GD100AADDRESSABLE METHANE GAS DETECTOR,CH4, IP55, can be directly connected on HEPHAIS loops, integrated isolator, needs external power supply
CARBON MONOXID GAS TEST BOTTLE, 250ppm,12 liters
COGAS
GD102AADDRESSABLE PETROL STEAM GAS DETECTOR, IP55, can be directly connectedon HEPHAIS loops, integrated isolator, needsexternal power supply
PETROL STEAM GAS TEST BOTTLE , 40% L.I.E, 12 liters
VPGAS
METHANE GAS TEST BOTTLE , 40% L.I.E, 12 litersMEGASGD104AADDRESSABLE HYDROGENE GAS DETECTOR,H2, IP55, can be directly connected on HEPHAIS loops, integrated isolator, needs external power supply
GD105AADDRESSABLE LIQUID PROPANE GAS DETECTOR, LPG, IP55, can be directly connected on HEPHAIS loops, integrated isolator, needs external power supply
GD106AADDRESSABLE PROPANE GAS DETECTOR,C3H8, IP55, can be directly connected on HEPHAIS loops, integrated isolator, needs external power supply
GD109AADDRESSABLE ACETILENE GAS DETECTOR,C2H2, IP55, can be directly connected on HEPHAIS loops, integrated isolator, needs external power supply
TEST KIT GAS DETECTORS (valve + adapter)P7150V
REMOTE CONTROL WITH DISPLAY AND KEYPADfor GAS DETECTORS, permits to read the leveland data of the detector (sensitivity, thresholds…)
DETTEL
GD113AADDRESSABLE CARBON MONOXIDE GAS DETECTOR, CO, IP55, ELECTROCHEMICALCELL, can be directly connected on HEPHAISloops, integrated isolator, needs externalpower supply
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:43 Pagina 36
37
GAS DETECTION
SD2243GPExd LPG GAS DETECTOR, 0-100% LEL,εx 2GD Ex d IIC T6 Ex tD A21 IP65
T 85°C
SD2243H2Exd HYDROGEN GAS DETECTOR, 0-100% LEL, εx 2GD Ex d IIC T6 Ex tDA21 IP65 T 85°C
SD2243MEExd METHANE GAS DETECTOR, 0-100%LEL, εx 2GD Ex d IIC T6 Ex tD A21 IP65 T 85°C
Calibration adapterZMCAP
SD2243VBExd PETROL STEAM GAS DETECTOR, 0-100% LEL, εx 2GD Ex d IIC T6 Ex tDA21 IP65 T 85°C
SD2243BUExd BUTANE GAS DETECTOR, 0-100%LEL, εx 2GD Ex d IIC T6 Ex tD A21 IP65 T 85°C
Calibration keypad to adjust the detector zeroand span values
STS/CKD
PLUG-IN 3 RELAY CARD, NO-NC 30V/1A , to beplugged inside the detector, permits to repeatALARM, PREALARM, FAULT of the detector
STS3REL
SD2243PRExd PROPANE GAS DETECTOR, 0-100%LEL, εx 2GD Ex d IIC T6 Ex tD A21 IP65T 85°C
Flammable gas Accessories
SD2244AMExd AMMONIAC GAS DETECTOR, 0-100% LEL, εx 2GD Ex d IIC T6 Ex tDA21 IP65 T 85°C
Toxic gas
SD2245O2Exd OXYGEN GAS DETECTOR, 0-200ppm, εx 2GD Ex d IIC T6 IP65
SD2246AMExd AMMONIAC GAS DETECTOR, 0-200ppm, εx 2GD Ex d IIC T6 IP65
SD2247AMExd AMMONIAC GAS DETECTOR, 0-1000ppm, εx 2GD Ex d IIC T6 IP65
EXPLOSION PROOF GAS DETECTION
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:44 Pagina 37
MARINE
38
ADDRESSABLE PANELS
HEPHAIS 128-MINTELLIGENT/INTERACTIVE COMPACT CONTROL PANEL, 128 ADDRESSES, 2 loops or 4 spur circuits (open circuit withmax 32 addresses), 99 ZONES, 1000 memory events, 1 monitored sounders line + 5 programmable output relays,1xRS232 serial output for printer or remote control panel, 2 programmable inputs. The panel can be set by keyboard or software. Needs 2 internal batteries 12V/7Ah. EN54-2, EN54-4, CE according to CPD, Marine Bureau veritas approved
From 1 to 1600 addresses
HEPHAIS 1600-400/LPM-MMODULAR INTELLIGENT/INTERACTIVE FIRE CONTROL PANEL MAX 1600 POINTS, 10 LOOPS - supplied as standard for400 points on 2 loops (max 200 addresses/loop) or 4 spur circuits, EN54-2, EN 54-4, in large metallic box withintegrated front panel, 1000 Zones, 2700 memory events, 2 monitored sounders lines + 3 programmableoutput relays, 1xRS232 serial output for printer and 1xRS485 serial output for remote control panel, 4 programmable inputs, RS422 JBUS monitoring output , networkable with MGNET board. Needs 2 internal batteries12V/17Ah. EN54-2, EN54-4, CE according to CPD, Marine Bureau veritas approved
From 1 to 128 addresses
ADDRESSABLE DETECTORS
OA05-MINTELLIGENT/INTERACTIVE OPTICAL SMOKE DETECTOR, microprocessor based , 1 programmable remotealarm indicator output, 8 levels sensitivity setting, EN54-7 edition 2000, CE according to CPD, Marine Bureau veritas approved
TA05-MINTELLIGENT/INTERACTIVE HEAT DETECTOR, static or/and rate of rise, microprocessor based , 1 programmableremote alarm indicator output, 6 levels sensitivity setting, EN54-5 edition 2000, CE according to CPD, Marine Bureau veritas approved
UNIVERSAL BASE WITH STICK ADDRESS SOCKET for 05-range conventional and addressable detectors
S05SE
WATERPROOF universal base with glands for 05 range (IP65), base with tubes connections supplied with glands
DMA05-MADDRESSABLE MANUAL CALL POINT - resettable with key without breaking glass, integrated isolator, red colour,EN54-11, EN54-17, CE according to CPD, Marine Bureau veritas approved
MBA95-MADDRESSABLE ZONE INTERFACE MODULE with backbox, for max 32 conventional points, isolator integrated, opto-isolated onthe secondary line, EN54-17, EN54-18, EN54-13 CE according to CPD, Marine Bureau veritas approved
BRI + S05
PLUG IN ISOLATOR BOARD for 05 detectors (to be plugged in S05SE)ICC05
ETC05-B-MADDRESSABLE INPUT/OUTPUT MODULE with backbox, isolator integrated, NO or NC monitoring for input , relay output NO-NC30V/1A, EN54-17, EN54-18 CE according to CPD (exists also in RAIL DIN version), Marine Bureau veritas approved
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:44 Pagina 38
39
VOICE EVACUATION SYSTEMS
SEV-CVOICE EVACUATION CENTRAL PANEL, manages max 8 speakers, connected to monitored sounder lineor relay contact, needs 24Vdc external power supply, 30s of message + 4s of sound of sounder
SPEAKERS
STR50SATELLITE SPEAKER 105db, max 8 per line
STR44SATELLITE SPEAKER 115db, max 8 per line
SNR35SATELLITE SPEAKER 125db, max 4 per line
VOICE SOUNDERS
DSV110/WHIGH POWERED VOICE SOUNDER 100db@1m, (8s message), white colour, can be directly connected on sounderlines
PROG DSV 110BOARD FOR programming the voice message
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:45 Pagina 39
ELECTRIC LOCK FOREMERGENCY EXIT DOORS
40
DS3000ELECTRIC LOCK FOR EMERGENCY exit doors with single action
DS3000 2VTXELECTRIC LOCK FOR EMERGENCY exit doors with double actions
CLEVLOCAL COMMAND of evacuation with key
FIRE ALARM CABLE
S-3ANT20502x0,5 mm2 (diam 0,8) cable , twisted with screen, polyvinylchloride rated , flame retardant, red colored (rolls by200m)
S-3ANT20102x1,00 mm2 cable , twisted with screen, polyvinylchloride rated , flame retardant, red colored (rolls by 200m)
FIRE PROOF CABLE
S-AFU20152x1,5 mm2 cable ,insulated with flame barrier, fire resistant 750°C according to IEC60331, red colored (rolls by200m)
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:45 Pagina 40
41
MAINTENANCE EQUIPMENT
3010Smoke detector tester
3015Aerosol bottle of 250 ml (pack of 12)
3053Heat detector tester (head and 12V controller)
305912V charger
406505 removal tool
405195 removal tool
2001Telescopic access pole 2x1.50m
2002Telescopic access pole 2x2.00m
Telescopic access Accessories
2.00m extension1005
1.50m extension1004
1.00m extension1001
TEST AND MOUNTING TOOLS
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:45 Pagina 41
MAINTENANCE EQUIPMENT
42
SPARE PARTS
AL2BOARDALPHA 2 MOTHER BOARD
Alpha 4/8/12
AR4DALPHA 4/8/12 MOTHER BOARD
Hephais 128
MP128HEPHAIS 128 MOTHER BOARD
Hephais 1600 NE
MB2BPANEL’S MAIN CPU BOARD
MB2B NEPANEL’S MAIN CPU BOARD
ALBA150POWER SUPPLY FOR HEPHAIS 1600
Alpha 2
Hephais 1600
ALBA150POWER SUPPLY FOR HEPHAIS 1600
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:46 Pagina 42
43
MAINTENANCE EQUIPMENT
Alpha 500/1000
CPUBCPU board for alpha 500/1000
ALBAPOWER supply for ALPHA 500/1000
MD1B05Extension module for 4 spur circuits (max 32 points per circuit) or 2 loops (max 125 points), for 05 intelligent detectors range
MD1BExtension module for 4 spur circuits (max 32 points per circuit) or 2 loops (max 125 points), for 95 detectors range
ESAL D 3UUser interface panel with alphanumeric display 160 characters and keyboard, rack mount version 19", for ALPHA 500/1000
OA95Analogue/addressable optical smoke detector, EN54-7
95 serie detectors
TVA95Analogue/addressable rate of rise + fixed heat detector, EN54-5
TPA95Analogue/addressable fixed heat detector, EN54-5
OTA95Analogue/addressable multicriteria (optical-heat) detector EN54-7
S95Universal base for conventional and analogue detectors
DLFB AADDRESSABLE BEAM DETECTOR (loop powered) for linear smoke detection supplied with reflector for distance from 3 up to 100 meters,integrated isolator,visible ray for alignment, EN54-12, for ALPHA 500/1000 panels
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:47 Pagina 43
lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:47 Pagina 44