Flygt 3102, 50Hz
TechnicalSpecification
Table of Contents
C-pump, Standard Motor......................................................................................................................2Product description.............................................................................................................................2Motor rating and performance curves..............................................................................................4
C-pump, Premium Efficiency Motor.....................................................................................................6Product description.............................................................................................................................6Motor rating and performance curves..............................................................................................8
D-pump.................................................................................................................................................10Product description..........................................................................................................................10Motor rating and performance curves...........................................................................................12
F-pump..................................................................................................................................................15Product description..........................................................................................................................15Motor rating and performance curves...........................................................................................17
M-pump.................................................................................................................................................19Product description..........................................................................................................................19Motor rating and performance curves...........................................................................................21
N-pump, Standard Motor...................................................................................................................24Product description..........................................................................................................................24Motor rating and performance curves...........................................................................................26
N-pump, Premium Efficiency Motor (IE3).........................................................................................30Product description..........................................................................................................................30Motor rating and performance curves 3102.800/.810.................................................................32Motor rating and performance curves 3102.820/.830.................................................................35Motor rating and performance curves 3102.900/.910.................................................................38
Dimensions and Weight......................................................................................................................42Drawings, C-pump............................................................................................................................42Drawings, D-pump............................................................................................................................46Drawings, F-pump.............................................................................................................................47Drawings, M-pump...........................................................................................................................48Drawings, N-pump............................................................................................................................49
Table of Contents
Flygt 3102, 50Hz Technical Specification 1
C-pump, Standard MotorProduct descriptionUsage
Submersible pump for pumping clean water, surface water and waste water containingsolids or long-fibred material.
Denomination
Type Non explosion proofversion
Explosion proofversion
Pressure class Installation types
Standard 3102.181 3102.090 MT — Medium head P, S, T, Z
The pump can be used in the following installations:
P Semi permanent, wet well arrangement with pump installed on two guide bars withautomatic connection to discharge.
S Portable semi permanent, wet well arrangement with hose coupling or flange forconnection to discharge pipeline.
T Vertical permanent, dry well arrangement with flange connection to suction anddischarge piping.
Z Horizontal permanent, dry well arrangement with flange connection to suction anddischarge piping.
Application Limits
Feature Description
Liquid temperature Maximum 40°C, (104°F)
Liquid temperature, warm water version Maximum 70°C, (158°F)
Depth of immersion Maximum 20 m (65 ft)
pH of the pumped liquid 5.5 – 14
Liquid density Maximum 1100 kg/m3
Motor data
Feature Description
Motor type Squirrel-cage induction motor
Frequency 50 Hz
Power supply
Starting method • Direct on-line• Star-delta
Number of starts per hour Maximum 30
Code compliance IEC 60034-1
Rated output variation ±10%
C-pump, Standard Motor
2 Flygt 3102, 50Hz Technical Specification
Feature Description
Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%
Voltage imbalancebetween phases
Maximum 2%
Insulation class H (180°C, 356°F)
Cables
Application Type Denomination
Direct-on-line start SUBCAB® heavy-duty submersiblecable
4G2.5 mm2
4G2.5+2×1.5 mm2
Y/D start SUBCAB® heavy-duty submersiblecable
7G2.5 mm2
7G2.5+2×1.5 mm2
Monitoring EquipmentThermal contacts opening temperature 125° C (257° F)
MaterialsDenomination Material ASTM EN
Major castings Cast iron, gray 35B GJL-250
Pump housing,alternative 1
Cast iron, gray 35B GJL-250
Pump housing,alternative 2
Cast iron, gray ASTM A 48 NO 30B GJL-200
Impeller Cast iron, gray 35B GJL-250
Wear ring, alternative 1 Rubber material, NBR
Wear ring, alternative 2 Bronze C924 CC491K, CC492K
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH
O-rings, alternative 2 Fluorinated rubber (FPM)70° IRH
Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878(a)
Table 1: Mechanical face seals
Alternative Inner seal Outer seal
1 Aluminum oxide/ Corrosion resistantcemented carbide
Aluminum oxide/ Corrosion resistantcemented carbide
2 Aluminum oxide/ Corrosion resistantcemented carbide
Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
C-pump, Standard Motor
Flygt 3102, 50Hz Technical Specification 3
Alternative Inner seal Outer seal
3 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Aluminum oxide/ Corrosion resistantcemented carbide
4 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Surface Treatment
Priming Finish
Painted with a primer, see internal standardM0700.00.0002
Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.
Options• Warm liquid version (non-explosion proof versions)• Leakage sensor in the stator housing (FLS)• Leakage sensor in the oil housing (CLS)• Surface treatment (Epoxy)• Zinc anodes• Other cables
AccessoriesDischarge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables.
Motor rating and performance curvesStar-delta starting current is 1/3 of Direct on-line starting current.
C-pump, Standard Motor
4 Flygt 3102, 50Hz Technical Specification
MT
WS005029A
Table 2: 400 V, 50 Hz, 3–phase
Ratedpower kW
Ratedpower hp
Curve/ImpellerNo
Revolutions perminute,rpm
Ratedcurrent, A
Startingcurrent, A
Powerfactor, cosφ
Impellerthoughlet,mm
Installation
2,4 3,2 432 1455 5,1 33 0,8 76 T,Z
2,4 3,2 433 1455 5,1 33 0,8 76 T,Z
2,4 3,2 434 1455 5,1 33 0,8 76 T,Z
2,4 3,2 435 1455 5,1 33 0,8 76 T,Z
3,1 4,2 430 1440 6,3 33 0,85 76 P,S
3,1 4,2 432 1440 6,3 33 0,85 76 P,S
3,1 4,2 433 1440 6,3 33 0,85 76 P,S
3,1 4,2 434 1440 6,3 33 0,85 76 P,S
3,1 4,2 435 1440 6,3 33 0,85 76 P,S
C-pump, Standard Motor
Flygt 3102, 50Hz Technical Specification 5
C-pump, Premium Efficiency MotorProduct descriptionUsage
Submersible pump for pumping clean water, surface water and waste water containingsolids or long-fibred material.
Denomination
Type Non explosion proofversion
Explosion proofversion
Pressure class Installation types
Standard 3102.800 3102.810 • MT — Mediumhead
P, S, T, Z
The pump can be used in the following installations:
P Semi permanent, wet well arrangement with pump installed on two guide bars withautomatic connection to discharge.
S Portable semi permanent, wet well arrangement with hose coupling or flange forconnection to discharge pipeline.
T Vertical permanent, dry well arrangement with flange connection to suction anddischarge piping.
Z Horizontal permanent, dry well arrangement with flange connection to suction anddischarge piping.
Application Limits
Feature Description
Liquid temperature Maximum 40°C, (104°F)
Liquid temperature, warm water version Maximum 70°C, (158°F)
Depth of immersion Maximum 20 m (65 ft)
pH of the pumped liquid 5.5 – 14
Liquid density Maximum 1100 kg/m3
Motor data
Feature Description
Motor type Line started permanent magnet motor (LSPM)
Frequency 50 Hz
Power supply 3-phase
Starting method • Direct on-line• Star-delta
Number of starts per hour Maximum 30
Code compliance IEC 60034-1
Rated output variation ±10%
C-pump, Premium Efficiency Motor
6 Flygt 3102, 50Hz Technical Specification
Feature Description
Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%
Voltage imbalancebetween phases
Maximum 2%
Insulation class H (180°C, 356°F)
Cables
Application Type Denomination
Direct-on-line start SUBCAB® heavy-duty submersiblecable
4G2.5+2×1.5 mm2
S3×2.5 mm2
S6×2.5+2×1.5 mm2
Y/D start SUBCAB® heavy-duty submersiblecable
7G2.5+2×1.5 mm2
Screened SUBCAB® heavy-dutysubmersible cable
S3×2.5+3×2.5/3+4×1.5 mm2
Monitoring EquipmentThermal contacts opening temperature 125° C (257° F)
MaterialsDenomination Material ASTM EN
Major castings Cast iron, gray 35B GJL-250
Pump housing,alternative 1
Cast iron, gray 35B GJL-250
Pump housing,alternative 2
Cast iron, gray ASTM A 48 NO 30B GJL-200
Impeller Cast iron, gray 35B GJL-250
Wear ring, alternative 1 Rubber material, NBR – –
Wear ring, alternative 2 Bronze C924 CC491K, CC492K
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH – –
O-rings, alternative 2 Fluorinated rubber (FPM)70° IRH
– –
Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878(a)
– –
Table 3: Mechanical face seals
Alternative Inner seal Outer seal
1 Aluminum oxide/ Corrosion resistantcemented carbide
Aluminum oxide/ Corrosion resistantcemented carbide
C-pump, Premium Efficiency Motor
Flygt 3102, 50Hz Technical Specification 7
Alternative Inner seal Outer seal
2 Aluminum oxide/ Corrosion resistantcemented carbide
Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
3 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Aluminum oxide/ Corrosion resistantcemented carbide
4 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Surface Treatment
Priming Finish
Painted with a primer, see internal standardM0700.00.0002
Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.
Options• Leakage sensor in the stator housing (FLS)• Leakage sensor in the oil housing (CLS)• Surface treatment (Epoxy)• Zinc anodes• Other cables
AccessoriesDischarge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables.
Motor rating and performance curvesStar-delta starting current is 1/3 of Direct on-line starting current.
C-pump, Premium Efficiency Motor
8 Flygt 3102, 50Hz Technical Specification
MT
Q [l/s]
H [m]
2P [kW]
0 5 10 15 20 25 30 35 400
2
4
6
8
10
12
0.0
0.5
1.0
1.5
2.0
2.5
MT
432
432
433
433
434
434435
435
WS005230A
Table 4: 400 V, 50 Hz, 3–phase
Rated powerkW
Rated powerhp
Curve/Impeller No
Revolutionsper minute,rpm
Ratedcurrent, A
Startingcurrent, A
Power factor,cos φ
Installation
3.5 4.7 432 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 433 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 434 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 435 1500 6.3 40 .88 P,S,T,Z
C-pump, Premium Efficiency Motor
Flygt 3102, 50Hz Technical Specification 9
D-pumpProduct descriptionUsage
Submersible pump for pumping liquids containing solids, abrasive media or low volumesat high heads.
Denomination
Type Non explosion proofversion
Explosion proofversion
Pressure class Installation types
Standard 3102.181 3102.090 • MT — Mediumhead
• HT — High head
P, T, Z
The pump can be used in the following installations:
P Semi permanent, wet well arrangement with pump installed on two guide bars withautomatic connection to discharge.
T Vertical permanent, dry well arrangement with flange connection to suction anddischarge piping.
Z Horizontal permanent, dry well arrangement with flange connection to suction anddischarge piping.
Application Limits
Feature Description
Liquid temperature Maximum 40°C, (104°F)
Liquid temperature, warm water version Maximum 70°C, (158°F)
Depth of immersion Maximum 20 m (65 ft)
pH of the pumped liquid 5.5 – 14
Liquid density Maximum 1100 kg/m3
Motor data
Feature Description
Motor type Squirrel-cage induction motor
Frequency 50 Hz
Power supply 3-phase
Starting method • Direct on-line• Star-delta
Number of starts per hour Maximum 30
Code compliance IEC 60034-1
Rated output variation ±10%
Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%
D-pump
10 Flygt 3102, 50Hz Technical Specification
Feature Description
Voltage imbalancebetween phases
Maximum 2%
Insulation class H (180°C, 356°F)
Cables
Application Type Denomination
Direct-on-line start SUBCAB® heavy-duty submersiblecable
4G2.5 mm2
4G2.5+2×1.5 mm2
Y/D start SUBCAB® heavy-duty submersiblecable
7G2.5 mm2
7G2.5+2×1.5 mm2
Monitoring EquipmentThermal contacts opening temperature 125° C (257° F)
MaterialsDenomination Material ASTM EN
Major castings Cast iron, gray 35B GJL-250
Pump housing Cast iron, gray 35B GJL-250
Impeller Cast iron, gray 35B GJL-250
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH – –
O-rings, alternative 2 Fluorinated rubber (FPM)70° IRH
– –
Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878(a)
– –
Table 5: Mechanical face seals
Alternative Inner seal Outer seal
1 Aluminum oxide/ Corrosion resistantcemented carbide
Aluminum oxide/ Corrosion resistantcemented carbide
2 Aluminum oxide/ Corrosion resistantcemented carbide
Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
3 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Aluminum oxide/ Corrosion resistantcemented carbide
4 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
D-pump
Flygt 3102, 50Hz Technical Specification 11
Surface Treatment
Priming Finish
Painted with a primer, see internal standardM0700.00.0002
Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.
Options• Warm liquid version (non-explosion proof versions)• Leakage sensor in the stator housing (FLS)• Leakage sensor in the oil housing (CLS)• Surface treatment (Epoxy)• Zinc anodes• Other cables
AccessoriesDischarge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables.
Motor rating and performance curvesStar-delta starting current is 1/3 of Direct on-line starting current.
D-pump
12 Flygt 3102, 50Hz Technical Specification
MT
WS005023A
Table 6: 400 V, 50 Hz, 3–phase
Ratedpower kW
Ratedpower hp
Curve/ImpellerNo
Revolutions perminute,rpm
Ratedcurrent, A
Startingcurrent, A
Powerfactor, cosφ
Impellerthroughlet,mm
Installation
3,1 4,2 470 1440 6,3 33 0,85 – P
3,1 4,2 471 1440 6,3 33 0,85 100 P
3,1 4,2 472 1440 6,3 33 0,85 100 P
D-pump
Flygt 3102, 50Hz Technical Specification 13
HT
WS005032A
Table 7: 400 V, 50 Hz, 3–phase
Ratedpower kW
Ratedpower hp
Curve/ImpellerNo
Revolutions perminute,rpm
Ratedcurrent, A
Startingcurrent, A
Powerfactor, cosφ
Impellerthroughlet,mm
Installation
4,2 5,6 276 2850 8,2 52 0,94 52 P
4,2 5,6 278 2850 8,2 52 0,94 52 P
D-pump
14 Flygt 3102, 50Hz Technical Specification
F-pumpProduct descriptionUsage
Submersible pump for pumping liquid manure, or heavily contaminated sewage andsludge. The impeller is S-shaped and fitted with a cutting device.
Denomination
Type Non explosion proofversion
Explosion proofversion
Pressure class Installation types
Standard 3102.181 3102.090 LT — Low head P, S
The pump can be used in the following installations:
P Semi permanent, wet well arrangement with pump installed on two guide bars withautomatic connection to discharge.
S Portable semi permanent, wet well arrangement with hose coupling or flange forconnection to discharge pipeline.
Application Limits
Feature Description
Liquid temperature Maximum 40°C, (104°F)
Liquid temperature, warm water version Maximum 70°C, (158°F)
Depth of immersion Maximum 20 m (65 ft)
pH of the pumped liquid 5.5 – 14
Liquid density Maximum 1100 kg/m3
Motor data
Feature Description
Motor type Squirrel-cage induction motor
Frequency 50 Hz
Power supply 3-phase
Starting method • Direct on-line• Star-delta
Number of starts per hour Maximum 30
Code compliance IEC 60034-1
Rated output variation ±10%
Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%
Voltage imbalancebetween phases
Maximum 2%
Insulation class H (180°C, 356°F)
F-pump
Flygt 3102, 50Hz Technical Specification 15
Cables
Application Type Denomination
Direct-on-line start SUBCAB® heavy-duty submersiblecable
4G2.5 mm2
4G2.5+2×1.5 mm2
Y/D start SUBCAB® heavy-duty submersiblecable
7G2.5 mm2
7G2.5+2×1.5 mm2
Monitoring EquipmentThermal contacts opening temperature 125° C (257° F)
MaterialsDenomination Material ASTM EN
Major castings Cast iron, gray 35B GJL-250
Pump housing Cast iron, gray 35B GJL-250
Impeller Cast iron, nodular – GJS-400-18-LT
Suction cover Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH – –
O-rings, alternative 2 Fluorinated rubber (FPM)70° IRH
– –
Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878(a)
– –
Table 8: Mechanical face seals
Alternative Inner seal Outer seal
1 Aluminum oxide/ Corrosion resistantcemented carbide
Aluminum oxide/ Corrosion resistantcemented carbide
2 Aluminum oxide/ Corrosion resistantcemented carbide
Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
3 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Aluminum oxide/ Corrosion resistantcemented carbide
4 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Surface Treatment
Priming Finish
Painted with a primer, see internal standardM0700.00.0002
Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.
F-pump
16 Flygt 3102, 50Hz Technical Specification
Options• Warm liquid version (non-explosion proof versions)• Leakage sensor in the stator housing (FLS)• Leakage sensor in the oil housing (CLS)• Surface treatment (Epoxy)• Zinc anodes• Other cables
AccessoriesDischarge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables.
Motor rating and performance curvesStar-delta starting current is 1/3 of Direct on-line starting current.
LT
Q [l/s]
H [m]
2P [kW]
0 5 10 15 20 25 300
2
4
6
8
10
12
1.5
2.0
2.5
3.0
LT
490
490
491
491
492
492
493
493
494
494
WS005033A
Table 9: 400 V, 50 Hz, 3–phase
Rated powerkW
Rated powerhp
Curve/Impeller No
Revolutionsper minute,rpm
Ratedcurrent, A
Startingcurrent, A
Power factor,cos φ
Installation
3,1 4,2 490 1440 6,3 33 0,85 P,S
3,1 4,2 491 1440 6,3 33 0,85 P,S
3,1 4,2 492 1440 6,3 33 0,85 P,S
3,1 4,2 493 1440 6,3 33 0,85 P,S
F-pump
Flygt 3102, 50Hz Technical Specification 17
Rated powerkW
Rated powerhp
Curve/Impeller No
Revolutionsper minute,rpm
Ratedcurrent, A
Startingcurrent, A
Power factor,cos φ
Installation
3,1 4,2 494 1440 6,3 33 0,85 P,S
F-pump
18 Flygt 3102, 50Hz Technical Specification
M-pumpProduct descriptionUsage
Submersible pump for pumping waste water containing solids that need to be macerated.The impeller is equipped with a grinder device.
Denomination
Type Non explosion proofversion
Explosion proofversion
Pressure class Installation types
Standard 3102.170 3102.890 • LT — Low head• HT — High head
F, H, P
The pump can be used in the following installations:
F Free standing semi permanent, wet well arrangement where the pump is placed on afirm surface.
H Semi permanent, wet well quick connection suspended arrangement, incorporatingintegral non-return valve.
P Semi permanent, wet well arrangement with pump installed on two guide bars withautomatic connection to discharge.
Application Limits
Feature Description
Liquid temperature Maximum 40°C, (104°F)
Depth of immersion Maximum 20 m (65 ft)
pH of the pumped liquid 5.5 – 14
Liquid density Maximum 1100 kg/m3
Motor data
Feature Description
Motor type Squirrel-cage induction motor
Frequency 50 Hz
Power supply 3-phase
Starting method • Direct on-line• Star-delta
Number of starts per hour Maximum 30
Code compliance IEC 60034-1
Rated output variation ±10%
Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%
Voltage imbalancebetween phases
Maximum 2%
M-pump
Flygt 3102, 50Hz Technical Specification 19
Feature Description
Insulation class H (180°C, 356°F)
Cables
Application Type Denomination
Direct-on-line start SUBCAB® heavy-duty submersiblecable
4G2.5 mm2
4G2.5+2×1.5 mm2
Y/D start SUBCAB® heavy-duty submersiblecable
7G2.5 mm2
7G2.5+2×1.5 mm2
Monitoring EquipmentThermal contacts opening temperature 125° C (257° F)
MaterialsDenomination Material ASTM EN
Major castings Cast iron, gray 35B GJL-250
Pump housing Cast iron, gray 35B GJL-250
Impeller Cast iron, gray 30B GJL-200
Cutter wheel Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)
Cutter plate Stainless steel – –
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings Nitrile rubber (NBR) 70° IRH – –
Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878(a)
– –
Table 10: Mechanical face seals
Alternative Inner seal Outer seal
1 Aluminum oxide/ Corrosion resistantcemented carbide
Aluminum oxide/ Corrosion resistantcemented carbide
2 Aluminum oxide/ Corrosion resistantcemented carbide
Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
3 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Aluminum oxide/ Corrosion resistantcemented carbide
4 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
M-pump
20 Flygt 3102, 50Hz Technical Specification
Surface Treatment
Priming Finish
Painted with a primer, see internal standardM0700.00.0002
Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.
Options• Leakage sensor in the stator housing (FLS)• Leakage sensor in the oil housing (CLS)• Surface treatment (Epoxy)• Zinc anodes• Other cables
AccessoriesDischarge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables.
Motor rating and performance curvesStar-delta starting current is 1/3 of Direct on-line starting current.
M-pump
Flygt 3102, 50Hz Technical Specification 21
LT
WS005036A
Table 11: 400 V, 50 Hz, 3–phase
Rated powerkW
Rated powerhp
Curve/Impeller No
Revolutionsper minute,rpm
Ratedcurrent, A
Startingcurrent, A
Power factor,cos φ
Installation
4,4 5,9 210 2885 8,7 72 0,89 F,H,P
M-pump
22 Flygt 3102, 50Hz Technical Specification
HT
Q [l/s]
H [m]
2P [kW]
0 1 2 3 4 5 60
5
10
15
20
25
30
35
40
3.0
3.5
4.0
4.5
5.0
HT
261
261
WS005037A
Table 12: 400 V, 50 Hz, 3–phase
Rated powerkW
Rated powerhp
Curve/Impeller No
Revolutionsper minute,rpm
Ratedcurrent, A
Startingcurrent, A
Power factor,cos φ
Installation
4,4 5,9 261 2885 8,7 72 0,89 F,H,P
M-pump
Flygt 3102, 50Hz Technical Specification 23
N-pump, Standard MotorProduct descriptionUsage
The submersible pump is designed for pumping clean water, surface water, andwastewater containing solids or long-fibred material.
Denomination
Type Non explosion proofversion
Explosion proofversion
Pressure class Installation types
Adaptive 3102.160 3102.190 • LT — Low head• MT — Medium
head• SH — Super head
P, S, T, Z
Standard 3102.181 3102.090 L, P, S, T, Z
Hard-Iron™ 3102.185 3102.095 P, S, T, Z
The pump can be used in the following installations:
L Semi permanent, wet well column pipe arrangement where the well is divided into asuction part and a discharge part. Pump end equipped with guide vanes.
P Semi permanent, wet well arrangement with pump installed on two guide bars withautomatic connection to discharge.
S Portable semi permanent, wet well arrangement with hose coupling or flange forconnection to discharge pipeline.
T Vertical permanent, dry well arrangement with flange connection to suction anddischarge piping.
Z Horizontal permanent, dry well arrangement with flange connection to suction anddischarge piping.
Application Limits
Feature Description
Liquid temperature Maximum 40°C, (104°F)
Liquid temperature, warm water version Maximum 70°C, (158°F)
Depth of immersion Maximum 20 m (65 ft)
pH of the pumped liquid 5.5 – 14
Liquid density Maximum 1100 kg/m3
Motor data
Feature Description
Motor type Squirrel-cage induction motor
Frequency 50 Hz
Power supply 3-phase
Starting method • Direct on-line• Star-delta
Number of starts per hour Maximum 30
N-pump, Standard Motor
24 Flygt 3102, 50Hz Technical Specification
Feature Description
Code compliance IEC 60034-1
Rated output variation ±10%
Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%
Voltage imbalancebetween phases
Maximum 2%
Insulation class H (180°C, 356°F)
Cables
Application Type Denomination
Direct-on-line start SUBCAB® heavy-duty submersiblecableScreened SUBCAB® heavy-dutysubmersible cable
4G2.5 mm2
4G2.5+2×1.5 mm2
S3×2.5 mm2
S6×2.5+2×1.5 mm2
Y/D start SUBCAB® heavy-duty submersiblecable
7G2.5+2×1.5 mm2
S3×2.5+3×2.5/3+4×1.5 mm2
Monitoring EquipmentThermal contacts opening temperature 125° C (257° F)
MaterialsDenomination Material ASTM EN
Major castings Cast iron, gray 35B GJL-250
Pump housing,alternative 1
Cast iron, gray 35B GJL-250
Pump housing,alternative 2
Cast iron, gray ASTM A 48 NO 30B GJL-200
Impeller Alt 1 Cast iron, gray 35B GJL-250
Impeller Alt 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)
Insert ring Alt 1 Cast iron, gray 35B GJL-250
Insert ring Alt 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH – –
O-rings, alternative 2 Fluorinated rubber (FPM)70° IRH
– –
N-pump, Standard Motor
Flygt 3102, 50Hz Technical Specification 25
Denomination Material ASTM EN
Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878(a)
– –
Table 13: Mechanical face seals
Alternative Inner seal Outer seal
1 Aluminum oxide/ Corrosion resistantcemented carbide
Aluminum oxide/ Corrosion resistantcemented carbide
2 Aluminum oxide/ Corrosion resistantcemented carbide
Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
3 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Aluminum oxide/ Corrosion resistantcemented carbide
4 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Surface Treatment
Priming Finish
Painted with a primer, see internal standardM0700.00.0002
Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.
Options• Warm liquid version (non-explosion proof versions)• Leakage sensor in the stator housing (FLS)• Leakage sensor in the oil housing (CLS)• Surface treatment (Epoxy)• Zinc anodes• Other cables
AccessoriesDischarge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables.
Motor rating and performance curvesStar-delta starting current is 1/3 of Direct on-line starting current.
N-pump, Standard Motor
26 Flygt 3102, 50Hz Technical Specification
LT
Q [l/s]
H [m]
2P [kW]
0 10 20 30 40 50 60 700
2
4
6
8
10
1.5
2.0
2.5
3.0
3.5
420**
421*
421**
423**
423**
423*
423*
420**
420*
420*
421**
421*
LT
WS005038A
* Pumphousing with outlet 100 mm
** Pumphousing with outlet 150 mm
Table 14: 400 V, 50 Hz, 3–phase
Ratedpower kW
Ratedpower hp
Curve/Impeller No
Revolutions perminute, rpm
Ratedcurrent, A
Startingcurrent, A
Powerfactor, cos φ
Installation
2,4 3,2 421 1460 5,7 40 0,71 T,Z
2,4 3,2 423 1460 5,7 40 0,71 T,Z
3,1 4,2 420 1450 6,8 40 0,78 P,S
3,1 4,2 421 1450 6,8 40 0,78 P,S
3,1 4,2 423 1450 6,8 40 0,78 P,S
N-pump, Standard Motor
Flygt 3102, 50Hz Technical Specification 27
MT
Q [l/s]
H [m]
2P [kW]
0 10 20 30 40 500
2
4
6
8
10
12
14
0
1
2
3
460
460
461
461
462
462
464
464
463
463
MT
WS005039A
Table 15: 400 V, 50 Hz, 3–phase
Ratedpower kW
Ratedpower hp
Curve/Impeller No
Revolutions perminute, rpm
Ratedcurrent, A
Startingcurrent, A
Powerfactor, cos φ
Installation
2,4 3,2 462 1460 5,7 40 0,71 T,Z
2,4 3,2 463 1460 5,7 40 0,71 T,Z
2,4 3,2 464 1460 5,7 40 0,71 T,Z
3,1 4,2 460 1450 6,8 40 0,78 P,S
3,1 4,2 461 1450 6,8 40 0,78 P,S
3,1 4,2 462 1450 6,8 40 0,78 P,S
3,1 4,2 463 1450 6,8 40 0,78 P,S
3,1 4,2 464 1450 6,8 40 0,78 P,S
N-pump, Standard Motor
28 Flygt 3102, 50Hz Technical Specification
SH
Q [l/s]
H [m]
2P [kW]
0 5 10 15 20 25 300
5
10
15
20
25
30
2
3
4
5
256
255
255
256
SH
WS005040A
Table 16: 400 V, 50 Hz, 3–phase
Ratedpower kW
Ratedpower hp
Curve/Impeller No
Revolutions perminute, rpm
Ratedcurrent, A
Startingcurrent, A
Powerfactor, cos φ
Installation
4,2 5,6 255 2850 8,2 52 0,94 P,S
4,2 5,6 256 2850 8,2 52 0,94 T,Z
N-pump, Standard Motor
Flygt 3102, 50Hz Technical Specification 29
N-pump, Premium Efficiency Motor(IE3)Product descriptionUsage
The submersible pump is designed for pumping clean water, surface water, andwastewater containing solids or long-fibred material.
Denomination
Type Non explosion proofversion
Explosion proofversion
Pressure class Installation types
Standard 3102.800 3102.810 • LT — Low head• MT — Medium
head• SH — Super head
P, S, T, Z
Hard-Iron™ 3102.820 3102.820
Adaptive 3102.900 3102.910
The pump can be used in the following installations:
P Semi permanent, wet well arrangement with pump installed on two guide bars withautomatic connection to discharge.
S Portable semi permanent, wet well arrangement with hose coupling or flange forconnection to discharge pipeline.
T Vertical permanent, dry well arrangement with flange connection to suction anddischarge piping.
Z Horizontal permanent, dry well arrangement with flange connection to suction anddischarge piping.
Application Limits
Feature Description
Liquid temperature Maximum 40°C, (104°F)
Liquid temperature, warm water version Maximum 70°C, (158°F)
Depth of immersion Maximum 20 m (65 ft)
pH of the pumped liquid 5.5 – 14
Liquid density Maximum 1100 kg/m3
Motor data
Feature Description
Motor type Line started permanent magnet motor (LSPM)
Frequency 50 Hz
Power supply 3-phase
Starting method • Direct on-line• Star-delta
Number of starts per hour Maximum 30
N-pump, Premium Efficiency Motor (IE3)
30 Flygt 3102, 50Hz Technical Specification
Feature Description
Code compliance IEC 60034-1
Rated output variation ±10%
Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%
Voltage imbalancebetween phases
Maximum 2%
Insulation class H (180°C, 356°F)
Cables
Application Type Denomination
Direct-on-line start SUBCAB® heavy-duty submersiblecable
4G2.5 mm2
4G2.5+2×1.5 mm2
7G2.5 mm2
7G2.5+2×1.5 mm2
Y/D start SUBCAB® heavy-duty submersiblecable
7G2.5 mm2
7G2.5+2×1.5 mm2
Screened SUBCAB® heavy-dutysubmersible cable
S3×2.5 mm2
S3×2.5+3×2.5/3+4×1.5 mm2
S6×2.5+2×1.5 mm2
Monitoring EquipmentThermal contacts opening temperature 125° C (257° F)
MaterialsDenomination Material ASTM EN
Major castings Cast iron, gray 35B GJL-250
Pump housing,alternative 1
Cast iron, gray 35B GJL-250
Pump housing,alternative 2
Cast iron, gray ASTM A 48 NO 30B GJL-200
Impeller Alt 1 Cast iron, gray 35B GJL-250
Impeller Alt 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)
Insert ring Alt 1 Cast iron, gray 35B GJL-250
Insert ring Alt 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)
Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …
O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH – –
O-rings, alternative 2 Fluorinated rubber (FPM)70° IRH
– –
N-pump, Premium Efficiency Motor (IE3)
Flygt 3102, 50Hz Technical Specification 31
Denomination Material ASTM EN
Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878(a)
– –
Table 17: Mechanical face seals
Alternative Inner seal Outer seal
1 Aluminum oxide/ Corrosion resistantcemented carbide
Aluminum oxide/ Corrosion resistantcemented carbide
2 Aluminum oxide/ Corrosion resistantcemented carbide
Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
3 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Aluminum oxide/ Corrosion resistantcemented carbide
4 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide
Surface Treatment
Priming Finish
Painted with a primer, see internal standardM0700.00.0002
Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.
Options• Leakage sensor in the stator housing (FLS)• Leakage sensor in the oil housing (CLS)• Surface treatment (Epoxy)• Zinc anodes• Other cables
AccessoriesDischarge connections, adapters, hose connections, and other mechanical accessories.
Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables.
Motor rating and performance curves 3102.800/.810Star-delta starting current is 1/3 of Direct on-line starting current.
N-pump, Premium Efficiency Motor (IE3)
32 Flygt 3102, 50Hz Technical Specification
LT
Q [l/s]
H [m]
2P [kW]
0 10 20 30 40 50 60 700
2
4
6
8
10
12
2.0
2.5
3.0
3.5
LT
420
420
420
421
421
421
423
423
423
WS005227A
Table 18: 400 V, 50 Hz, 3–phase
Rated powerkW
Rated powerhp
Curve/Impeller No
Revolutionsper minute,rpm
Ratedcurrent, A
Startingcurrent, A
Power factor,cos φ
Installation
3.5 4.7 420 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 421 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 423 1500 6.3 40 .88 P,S,T,Z
N-pump, Premium Efficiency Motor (IE3)
Flygt 3102, 50Hz Technical Specification 33
MT
Q [l/s]
H [m]
2P [kW]
0 10 20 30 40 500
2
4
6
8
10
12
14
16
0
1
2
3
MT
460
460
460
460
461
461461
462
462462
463
463463
464
464464
WS005228A
Table 19: 400 V, 50 Hz, 3–phase
Rated powerkW
Rated powerhp
Curve/Impeller No
Revolutionsper minute,rpm
Ratedcurrent, A
Startingcurrent, A
Power factor,cos φ
Installation
3.5 4.7 460 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 461 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 462 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 463 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 464 1500 6.3 40 .88 P,S,T,Z
N-pump, Premium Efficiency Motor (IE3)
34 Flygt 3102, 50Hz Technical Specification
SH
Q [l/s]
H [m]
2P [kW]
0 5 10 15 20 25 300
5
10
15
20
25
30
1.52.02.53.03.54.0
SH
256
256
256
256
256
256256256
256
256
258
258
258258
WS005229A
Table 20: 400 V, 50 Hz, 3–phase
Rated powerkW
Rated powerhp
Curve/Impeller No
Revolutionsper minute,rpm
Ratedcurrent, A
Startingcurrent, A
Power factor,cos φ
Installation
2.8 3.8 256 3000 5.9 64 .77 T,Z
4.5 6 256 3000 8.5 64 .86 P,S
4.5 6 258 3000 8.5 64 .86 P,S
Motor rating and performance curves 3102.820/.830Star-delta starting current is 1/3 of Direct on-line starting current.
N-pump, Premium Efficiency Motor (IE3)
Flygt 3102, 50Hz Technical Specification 35
LT
Q [l/s]
H [m]
2P [kW]
0 10 20 30 40 50 60 700
2
4
6
8
10
12
2.0
2.5
3.0
3.5
LT
420
420420
421
421
421
423
423
WS005224A
Table 21: 400 V, 50 Hz, 3–phase
Rated powerkW
Rated powerhp
Curve/Impeller No
Revolutionsper minute,rpm
Ratedcurrent, A
Startingcurrent, A
Power factor,cos φ
Installation
3.5 4.7 420 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 421 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 423 1500 6.3 40 .88 P,S,T,Z
N-pump, Premium Efficiency Motor (IE3)
36 Flygt 3102, 50Hz Technical Specification
MT
Q [l/s]
H [m]
2P [kW]
0 10 20 30 40 500
2
4
6
8
10
12
14
16
0
1
2
3
MT
460
460460
461
461461
462
462462
463
463463
464
464464
WS005225A
Table 22: 400 V, 50 Hz, 3–phase
Rated powerkW
Rated powerhp
Curve/Impeller No
Revolutionsper minute,rpm
Ratedcurrent, A
Startingcurrent, A
Power factor,cos φ
Installation
3.5 4.7 460 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 461 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 462 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 463 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 464 1500 6.3 40 .88 P,S,T,Z
N-pump, Premium Efficiency Motor (IE3)
Flygt 3102, 50Hz Technical Specification 37
SH
Q [l/s]
H [m]
2P [kW]
0 5 10 15 20 25 300
5
10
15
20
25
30
1.52.02.53.03.54.0
SH
256
256
256
256
256
256
256
256
256
256
256
256
258258
258
258
WS005226A
Table 23: 400 V, 50 Hz, 3–phase
Rated powerkW
Rated powerhp
Curve/Impeller No
Revolutionsper minute,rpm
Ratedcurrent, A
Startingcurrent, A
Power factor,cos φ
Installation
2.8 3.8 256 3000 5.9 64 .77 T,Z
4.5 6 256 3000 8.5 64 .86 P,S
4.5 6 258 3000 8.5 64 .86 P,S
Motor rating and performance curves 3102.900/.910Star-delta starting current is 1/3 of Direct on-line starting current.
N-pump, Premium Efficiency Motor (IE3)
38 Flygt 3102, 50Hz Technical Specification
LT
Q [l/s]
H [m]
2P [kW]
0 10 20 30 40 50 60 700
2
4
6
8
10
12
2.0
2.5
3.0
3.5
LT
420
420420
421
421
421
423
423
423
WS005222A
Table 24: 400 V, 50 Hz, 3–phase
Rated powerkW
Rated powerhp
Curve/Impeller No
Revolutionsper minute,rpm
Ratedcurrent, A
Startingcurrent, A
Power factor,cos φ
Installation
3.5 4.7 420 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 421 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 423 1500 6.3 40 .88 P,S,T,Z
N-pump, Premium Efficiency Motor (IE3)
Flygt 3102, 50Hz Technical Specification 39
MT
Q [l/s]
H [m]
2P [kW]
0 10 20 30 40 500
2
4
6
8
10
12
14
16
0
1
2
3
MT
460
460
460
460
461
461461
462
462462
463
463463
464
464464
WS005223A
Table 25: 400 V, 50 Hz, 3–phase
Rated powerkW
Rated powerhp
Curve/Impeller No
Revolutionsper minute,rpm
Ratedcurrent, A
Startingcurrent, A
Power factor,cos φ
Installation
3.5 4.7 460 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 461 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 462 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 463 1500 6.3 40 .88 P,S,T,Z
3.5 4.7 464 1500 6.3 40 .88 P,S,T,Z
N-pump, Premium Efficiency Motor (IE3)
40 Flygt 3102, 50Hz Technical Specification
SH
Q [l/s]
H [m]
2P [kW]
0 5 10 15 20 25 300
5
10
15
20
25
30
1.52.02.53.03.54.0
SH
256256256256
256
256
258
258
258
WS005215A
Table 26: 400 V, 50 Hz, 3–phase
Rated powerkW
Rated powerhp
Curve/Impeller No
Revolutionsper minute,rpm
Ratedcurrent, A
Startingcurrent, A
Power factor,cos φ
Installation
2.8 3.8 256 3000 5.9 64 .77 T,Z
4.5 6 256 3000 8.5 64 .86 P,S
4.5 6 258 3000 8.5 64 .86 P,S
N-pump, Premium Efficiency Motor (IE3)
Flygt 3102, 50Hz Technical Specification 41
Dimensions and WeightDrawings, C-pump
All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).Contact your sales representative for more information.
All dimensions are in mm.
Figure 1: LT, P-installation Figure 2: LT, P-installation
Dimensions and Weight
42 Flygt 3102, 50Hz Technical Specification
Figure 3: LT, P-installation Figure 4: LT, S-installation
Figure 5: LT, S-installation Figure 6: LT, T-installation
Dimensions and Weight
Flygt 3102, 50Hz Technical Specification 43
Figure 7: LT, T-installation Figure 8: LT, Z-installation
Figure 9: LT, Z-installation Figure 10: MT, P-installation
Dimensions and Weight
44 Flygt 3102, 50Hz Technical Specification
Figure 11: MT, S-installation Figure 12: MT, T-installation
Figure 13: MT, Z-installation Figure 14: HT/SH, P-installation
Dimensions and Weight
Flygt 3102, 50Hz Technical Specification 45
Figure 15: HT/SH, S-installation Figure 16: HT/SH, T-installation
Figure 17: HT/SH, Z-installation
Drawings, D-pumpAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).Contact your sales representative for more information.
All dimensions are in mm.
Dimensions and Weight
46 Flygt 3102, 50Hz Technical Specification
Figure 18: MT, P-installation Figure 19: HT, P-installation
Figure 20: HT, P-installation
Drawings, F-pumpAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).Contact your sales representative for more information.
All dimensions are in mm.
Dimensions and Weight
Flygt 3102, 50Hz Technical Specification 47
Figure 21: J-installation Figure 22: LT, P-installation
Figure 23: LT, S-installation
Drawings, M-pumpAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).Contact your sales representative for more information.
All dimensions are in mm.
Dimensions and Weight
48 Flygt 3102, 50Hz Technical Specification
Figure 24: LT, F-installation Figure 25: LT, P-installation
Figure 26: HT, F-installation Figure 27: HT, P-installation
Drawings, N-pumpAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).Contact your sales representative for more information.
All dimensions are in mm.
Dimensions and Weight
Flygt 3102, 50Hz Technical Specification 49
Figure 28: LT, P-installation Figure 29: LT, P-installation
Figure 30: LT, S-installation Figure 31: LT, S-installation
Dimensions and Weight
50 Flygt 3102, 50Hz Technical Specification
Figure 32: MT, P-installation Figure 33: MT, P-installation
Figure 34: MT, S-installation Figure 35: MT, S-installation
Dimensions and Weight
Flygt 3102, 50Hz Technical Specification 51
Figure 36: HT/SH, P-installation Figure 37: HT, S-installation
Figure 38: J-installation
Dimensions and Weight
52 Flygt 3102, 50Hz Technical Specification
Xylem |’zīləm|
1) The tissue in plants that brings water upward from the roots2) A leading global water technology company
We're 12,500 people unified in a common purpose: creatinginnovative solutions to meet our world's water needs. Developing newtechnologies that will improve the way water is used, conserved, andre-used in the future is central to our work. We move, treat, analyze,and return water to the environment, and we help people use waterefficiently, in their homes, buildings, factories and farms. In more than150 countries, we have strong, long-standing relationships withcustomers who know us for our powerful combination of leadingproduct brands and applications expertise, backed by a legacy ofinnovation.
For more information on how Xylem can help you, go to xyleminc.com
Xylem Water Solutions ABGesällvägen 33174 87 SundbybergSwedenTel. +46-8-475 60 00Fax +46-8-475 69 00http://tpi.xyleminc.com
Visit our Web site for the latest version of thisdocument and more information
The original instruction is in English. All non-English instructions are translations of the originalinstruction.
© 2012 Xylem Inc.
883450_1.0_en.US_2012-07_TS_3102_50Hz