Visio-e100r scandia.vsdEvolution 100R
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290
[email protected]
Installation Instructions
Before you begin assembling your new E 100-R steam shower, site
preparation will make the installation go smoothly.
1 For wall installations, your ½ inch water connections should be
approximately 25" from the side wall and 51" from the floor. It is
advised to use flexible tubing (that meets your local code) that
provides at least 18" of length that will allow you to connect the
water lines while the unit is spaced from the wall for assembly
purposes. Plumbing must be performed according to local codes and
by a licensed professional.
2
3
The power connection for your Scandia E 100-R feeds the entire
electrical system. The power feeds should be located according to
the below listed parameters. Facing the wall, 120V (30A) GFI
breaker should be centered 7" from the left side. This GFI breaker
can also be located in main panel if according to local code. It
should be approximately 77" from the floor. The electrical
connection must be done according to local codes and by a licensed
professional.
In order to provide a direct drain to the plumbing system. Prepare
the shower drain location according to the specifications below.
The E 100-R drain and P-Trap provided is 1.7" dia. Local codes may
require larger drain diameters so it is important to anticipate
these requirements in order to make drain modifications if
necessary. Direct vertical drain location is 9 1/2" from back wall.
When using supplied P-trap assembly, place drain 3" from wall
(centered at 24 ½ ")
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-331-2880
[email protected]
Scandia E 100R Pre-Installation Setup
NOTE: all electrical and plumbing connections must be done by a
licensed professional and according to local codes.
Back-wall footprint 49"
120V 30A Supply Feed
Required
Your Scandia E 100R system is an advanced computer controlled steam
shower system. The system comes completely pre-wired with simple
snap-connectors allowing for easy assembly. To connect power to the
E 100R a waterproof GFI Breaker or Waterproof J-box must be
supplied behind the steam shower unit. For this 120 V system; the
black wire is for positive, white for neutral and green for
ground.
Circuit Breaker 30 Amp Power Supply 120V 20 Amp 50/60Hz Generator
3KW Radio 12V Fan 12V Lights 12V
E 100R Specifications
Positive Neutral Ground
Green - Ground
Green - Ground
Green - Ground
This Schematic is for reference only - actual connections may
vary
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290
[email protected]
Scandia E 100R Electrical Overview
NOTE: all electrical and plumbing connections must be done by a
licensed professional and according to local codes.
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290
[email protected]
Scandia E 100R Plumbing Overview
(Scandia E-100R, Water-line Overview)
To Steam Generator Intake
½” NPT Connection
½” NPT Connection
Your Scandia E 100R system water connections comes entirely
pre-plumbed from the factory. The only required connections are the
hot and cold water supply lines. The below plumbing diagram is for
reference only, if a water filter is desired for the steam
function, it should be placed before the cold water inlet. Factory
plumbing sequence may vary from below diagram. See below for drain
requirements.
NOTE: all electrical and plumbing connections must be done by a
licensed professional and according to local codes.
49" (1250 mm) 24 1/2"
(620 mm)
When Using P-Trap
Drain Location (10 - 12" from Wall)
Note: Drain diameter is 1.5". Local codes may require larger
drain
diameters. Consult your plumber for alternative drain
assemblies.
1.5"
(2) Glass Wall panels and wall frame runners.
(1) Ceiling (1) Base (2) Door runners.
(2) Wall Skirts (1) Back Wall Assembly
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290
[email protected]
Scandia E 100R Cabin Components
#1 #2 #3 #4 #5 Diameter 1/8" 1/8" 1/8" 3/16" 1/8" Length 5/8" 3/4"
1 1/8" 1" 2 1/4" Qty 14 10 8 5 4
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290
[email protected]
Scandia E 100R Accessories
Shower Bracket
Step 1 : Place both wall panels and wall runners on top and bottom
door runner assemblies. Use clear silicon sealant in the grooves
before inserting the wall panels. The glass wall panels will fit
tightly into the grooves on both sets of runners.
1
2
NOTE: all electrical and plumbing connections must be done by a
licensed professional and according to local codes.
Step 2 : Fasten door runners to wall panels (fig 2.1) with screws
#4. Next fasten wall runners to door runners (fig 2.2) with #3
screws. Install glass doors.
(fig 2.1)
(fig 2.1)
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290
[email protected]
Scandia E 100R Cabin Assembly
Step 3: Bring together the back wall panel with the newly assembled
glass wall unit. Run silicon bead along entire length of back panel
edge where it meets with the wall assembly.
3
Step 4: Fasten the back wall unit with newly assembled glass wall
unit (fig 4.1) with #1 screws. This must be done from behind the
back-wall unit into the glass wall assembly (see fig 4.2). NOTE: Do
not use electric or power screwdrivers - these assembly screws must
be tightened by hand.
4
(fig 4.2)
NOTE: Do not use electric or power screwdrivers - these assembly
screws must be tightened by hand.
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290
[email protected]
Scandia E 100R Cabin Assembly
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290
[email protected]
Scandia E 100R Cabin Assembly
Leveling peg locations
Step 5: Place the drain cover and flute on the top of the shower
pan. From below, tighten the black flute nut and screw on the
p-trap assembly. Place a small bead of silicone sealant on the
flute ring where it makes contact with the shower pan - wipe off
excess with a paper towel.
5
6 Step 6: The E100R shower pan contains seven leveling pegs. With a
cresent wrench, adjust the height of each peg so that they provide
flush support of the entire pan. It is helpful to run a straight
edge (e.g. board) along the pan skirt to set leg levels. This
system is designed to support applications where the floor is
slightly uneven. WARNING: improper setting of the leveling pegs can
result in damage of the pan’s metal support frame.
6
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290
[email protected]
Scandia E 100R Assembly
8 Step 8: Place the top panel on the wall assembly and fasten with
#2 screws from top down. Screw hole locations can be found on top
door runner and back-panel flange. When finished, seal entire seam
with silicone sealant.
7 Step 7: Once the shower pan is assembled, leveled and plumbing
connections made, place the wall/back-panel assembly on top of the
pan. This step will require two people. Next; screw the back panel
to the shower pan (fig 7.1) with #4 screws. Next; seal entire top
assembly and pan seam with silicone sealant.
Fig 7.1 Fig 7.1
8
7
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290
[email protected]
Scandia E 100R Assembly
)
9 Step 9: Insert the two side wall trim panels and fasten with #2
screws.
9
9 Step 9: Insert shower bracket, shower cable/head and door
handles.
1 2
Temperature D isp lay
Radio D isp lay
S team T ime Con t ro l
S team Temperature Cont ro l
CD / Radio ON / OFF Bu tton
Radio Vo lume Con t ro l
L igh t ON / OFF Bu t ton
Fan ON / OFF Bu t ton
Radio Tuner Con t ro ls
Shower ON / OFF Con t ro ls
Massage Je t ON / OFF Cont ro ls
Massage Con t ro ls
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Scandia E 100R Assembly
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290
[email protected]
Scandia E 100R Control Panel
1 Start-up
After complete assembly and installation of the unit, the computer
system will conduct self check-up. When the check-up is
complete, ‘-----‘ will appear on the time display and temperature
display, which means the unit is ready for operation.
Press on/off button, the indicator lamp is on, and the unit is
ready for operation.
(1) Steam Function
Press the steam button, the indicator lamp is on, and steam comes
out in 3 to 6 minutes regardless if the time and
or temperature was initially set. In case you want to select the
time and temperature, press +/- button to select the
time period which is showed in the indicator (ranging from 1 to 90
minutes). When the time is up, the steamer will be
switched off automatically. Press +/- button to select the
temperature which shall be kept constant (the steamer will
not
work with a selected temperature lower than the indoor
temperature). If it is adjusted to 50 degrees C, steam will
be
created automatically when the indoor temperature is lower than 50
degrees C. Push steam button again to stop the
steamer and the indicator lamp goes out (to avoid affecting the
water fill level of the steamer, don’t use the massage jet
system when using steamer).
(2) Hydraulic Massage Function
Press round massage button, the indicator lamp is on, massage
through auto-cycle pressure jet
(upper, middle and lower parts respectively) and the function will
not be controlled by time.
Press square button for directed massage. Press round button again
to stop massage system.
(3) Shower Function
Press shower button to start pressure jet shower from the top Press
the button again to stop the shower.
(5) Press round ON button, then press CD/FM button to select FM or
an external CD player. To set the
station, press use TUN (tuner button) button to select. The volume
can be adjusted by pressing the
VOL buttons. Press the round ON / OFF button to turn off the
radio.
(6) Shower Light and Fan
Both the light and fan can be controlled by their respective
control buttons illustrated here
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290
[email protected]
Scandia E 100R Control Panel
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290
[email protected]
Scandia E 100R Maintenance & Troubleshooting Guide
You can keep your E 110R like new for many year by following a few
simple rules.
Water Filtration The most important consideration is the quality of
water in your area. If your water supply has a high sulfur,
chlorine, limestone or other high-mineral content, it is
recommended that a water filter is placed before both hot and cold
water inlets. Be sure to change the filter at least every three
months. Such filter will reduce or eliminate harmful buildup on the
steam heating coils and reduce possible discoloration of the
acrylic panels. This filter will also ensure a clean and pleasant
steam bath experience.
Cleaning the Acrylic Panels NOTE: do not use an abrasive household
cleaning product, this will scratch the surface. Use a mild liquid
detergent to clean the panels. For polishing purposes you can use
any non-abrasive car polish (preferably #10) or any other solution
designed for acrylic.
Cleaning the Glass Walls/Doors Use any off-the-shelf glass cleaning
product that does not contain ammonia or any acid-based
solvent.
Cleaning the Shower Head In the event minerals begin to block your
shower head. Remove, disassemble and soak in a vinegar/water
solution for 24 hours. Do not use a wire brush for this will damage
the nozzle.
Repairing the Acrylic Panels Scratches in your acrylic panels can
be buffed out with #600 grit sand paper and followed with an
acrylic polish paste application. Cracks and significant damage can
be repaired on-site by a shower repair professional. Search your
local phone book under the BATHROOM/SHOWER heading.
Problem Possible Cause Solutions Control panel does not illuminate
or have power
• The control panel fuse is blown. • The GFI breaker has tripped. •
The main breaker has tripped.
• Replace the fuse. • Reset GFI breaker. • Reset main
breaker.
The steam generator does not work
• The control panel settings are not correct. • The high limit
switch has tripped. • The heating element has quit due to mineral
build-up. • The heating element has failed. • No water to steam
generator. • The system wires are loose or disconnected.
• Review operating instructions and repeat steps.
• Check the high-limit switch and its connections.
• Test and replace heating element. • Check the water supply. •
Clean the steam solenoid valve.
Check the connection wires and/or replace solenoid valve.
The controls are illumi- nated but the steam generator produces wa-
ter but no steam'
• Water-level probe wire loose or damaged. • Too much mineral
build-up on the water level probe.
• Check all connection wires. • De-scale generator heating
elements
and probe.
The shower nozzle does not spray water
• The solenoid valve wire is loose or damaged. • The water tap is
not turned on. • The water line to system has been turned
off.
• Check connections and/or change solenoid valve.
• Turn on water. • Open water line to system.
The shower/jet water pressure is low.
• The main water supply system is off or has limited
pressure.
• The filter is plugged.
• Open water-line to system. • Clean or replace water filter.
No sound from the radio • Wire connections are loose/damaged. • The
speakers are damaged.
• Check speaker wire connections. • Replace speakers.
The lights do not work • The wire connections are loose/damaged or
incorrect. • The bulb is out.
• Check light wire connections. • Replace bulb.
The fan does not work • The connection is incorrect. • The fan
motor is damaged.
• Check fan wire connections. • Replace fan motor.
PE Should be performed by an Licensed Electrician Should be
performed by an Licensed Plumber
P
P
E
E
E
E
E
E
P
P
E
Seats
Fan
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616
www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290
[email protected]
Scandia E 100R Features Overview