Evolution 100R Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected] Installation Instructions

Transcript of Evolution 100R

Visio-e100r scandia.vsdEvolution 100R
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected]
Installation Instructions
Before you begin assembling your new E 100-R steam shower, site preparation will make the installation go smoothly.
1 For wall installations, your ½ inch water connections should be approximately 25" from the side wall and 51" from the floor. It is advised to use flexible tubing (that meets your local code) that provides at least 18" of length that will allow you to connect the water lines while the unit is spaced from the wall for assembly purposes. Plumbing must be performed according to local codes and by a licensed professional.
2
3
The power connection for your Scandia E 100-R feeds the entire electrical system. The power feeds should be located according to the below listed parameters. Facing the wall, 120V (30A) GFI breaker should be centered 7" from the left side. This GFI breaker can also be located in main panel if according to local code. It should be approximately 77" from the floor. The electrical connection must be done according to local codes and by a licensed professional.
In order to provide a direct drain to the plumbing system. Prepare the shower drain location according to the specifications below. The E 100-R drain and P-Trap provided is 1.7" dia. Local codes may require larger drain diameters so it is important to anticipate these requirements in order to make drain modifications if necessary. Direct vertical drain location is 9 1/2" from back wall. When using supplied P-trap assembly, place drain 3" from wall (centered at 24 ½ ")
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-331-2880 [email protected]
Scandia E 100R Pre-Installation Setup
NOTE: all electrical and plumbing connections must be done by a licensed professional and according to local codes.
Back-wall footprint 49"
120V 30A Supply Feed
Required
Your Scandia E 100R system is an advanced computer controlled steam shower system. The system comes completely pre-wired with simple snap-connectors allowing for easy assembly. To connect power to the E 100R a waterproof GFI Breaker or Waterproof J-box must be supplied behind the steam shower unit. For this 120 V system; the black wire is for positive, white for neutral and green for ground.
Circuit Breaker 30 Amp Power Supply 120V 20 Amp 50/60Hz Generator 3KW Radio 12V Fan 12V Lights 12V
E 100R Specifications
Positive Neutral Ground
Green - Ground
Green - Ground
Green - Ground
This Schematic is for reference only - actual connections may vary
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected]
Scandia E 100R Electrical Overview
NOTE: all electrical and plumbing connections must be done by a licensed professional and according to local codes.
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected]
Scandia E 100R Plumbing Overview
(Scandia E-100R, Water-line Overview)
To Steam Generator Intake
½” NPT Connection
½” NPT Connection
Your Scandia E 100R system water connections comes entirely pre-plumbed from the factory. The only required connections are the hot and cold water supply lines. The below plumbing diagram is for reference only, if a water filter is desired for the steam function, it should be placed before the cold water inlet. Factory plumbing sequence may vary from below diagram. See below for drain requirements.
NOTE: all electrical and plumbing connections must be done by a licensed professional and according to local codes.
49" (1250 mm) 24 1/2"
(620 mm)
When Using P-Trap
Drain Location (10 - 12" from Wall)
Note: Drain diameter is 1.5". Local codes may require larger drain
diameters. Consult your plumber for alternative drain assemblies.
1.5"
(2) Glass Wall panels and wall frame runners.
(1) Ceiling (1) Base (2) Door runners.
(2) Wall Skirts (1) Back Wall Assembly
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected]
Scandia E 100R Cabin Components
#1 #2 #3 #4 #5 Diameter 1/8" 1/8" 1/8" 3/16" 1/8" Length 5/8" 3/4" 1 1/8" 1" 2 1/4" Qty 14 10 8 5 4
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected]
Scandia E 100R Accessories
Shower Bracket
Step 1 : Place both wall panels and wall runners on top and bottom door runner assemblies. Use clear silicon sealant in the grooves before inserting the wall panels. The glass wall panels will fit tightly into the grooves on both sets of runners.
1
2
NOTE: all electrical and plumbing connections must be done by a licensed professional and according to local codes.
Step 2 : Fasten door runners to wall panels (fig 2.1) with screws #4. Next fasten wall runners to door runners (fig 2.2) with #3 screws. Install glass doors.
(fig 2.1)
(fig 2.1)
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected]
Scandia E 100R Cabin Assembly
Step 3: Bring together the back wall panel with the newly assembled glass wall unit. Run silicon bead along entire length of back panel edge where it meets with the wall assembly.
3
Step 4: Fasten the back wall unit with newly assembled glass wall unit (fig 4.1) with #1 screws. This must be done from behind the back-wall unit into the glass wall assembly (see fig 4.2). NOTE: Do not use electric or power screwdrivers - these assembly screws must be tightened by hand.
4
(fig 4.2)
NOTE: Do not use electric or power screwdrivers - these assembly screws must be tightened by hand.
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected]
Scandia E 100R Cabin Assembly
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected]
Scandia E 100R Cabin Assembly
Leveling peg locations
Step 5: Place the drain cover and flute on the top of the shower pan. From below, tighten the black flute nut and screw on the p-trap assembly. Place a small bead of silicone sealant on the flute ring where it makes contact with the shower pan - wipe off excess with a paper towel.
5
6 Step 6: The E100R shower pan contains seven leveling pegs. With a cresent wrench, adjust the height of each peg so that they provide flush support of the entire pan. It is helpful to run a straight edge (e.g. board) along the pan skirt to set leg levels. This system is designed to support applications where the floor is slightly uneven. WARNING: improper setting of the leveling pegs can result in damage of the pan’s metal support frame.
6
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected]
Scandia E 100R Assembly
8 Step 8: Place the top panel on the wall assembly and fasten with #2 screws from top down. Screw hole locations can be found on top door runner and back-panel flange. When finished, seal entire seam with silicone sealant.
7 Step 7: Once the shower pan is assembled, leveled and plumbing connections made, place the wall/back-panel assembly on top of the pan. This step will require two people. Next; screw the back panel to the shower pan (fig 7.1) with #4 screws. Next; seal entire top assembly and pan seam with silicone sealant.
Fig 7.1 Fig 7.1
8
7
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected]
Scandia E 100R Assembly
)
9 Step 9: Insert the two side wall trim panels and fasten with #2 screws.
9
9 Step 9: Insert shower bracket, shower cable/head and door handles.
1 2
Temperature D isp lay
Radio D isp lay
S team T ime Con t ro l
S team Temperature Cont ro l
CD / Radio ON / OFF Bu tton
Radio Vo lume Con t ro l
L igh t ON / OFF Bu t ton
Fan ON / OFF Bu t ton
Radio Tuner Con t ro ls
Shower ON / OFF Con t ro ls
Massage Je t ON / OFF Cont ro ls
Massage Con t ro ls
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Scandia E 100R Assembly
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected]
Scandia E 100R Control Panel
1 Start-up
After complete assembly and installation of the unit, the computer system will conduct self check-up. When the check-up is
complete, ‘-----‘ will appear on the time display and temperature display, which means the unit is ready for operation.
Press on/off button, the indicator lamp is on, and the unit is ready for operation.
(1) Steam Function
Press the steam button, the indicator lamp is on, and steam comes out in 3 to 6 minutes regardless if the time and
or temperature was initially set. In case you want to select the time and temperature, press +/- button to select the
time period which is showed in the indicator (ranging from 1 to 90 minutes). When the time is up, the steamer will be
switched off automatically. Press +/- button to select the temperature which shall be kept constant (the steamer will not
work with a selected temperature lower than the indoor temperature). If it is adjusted to 50 degrees C, steam will be
created automatically when the indoor temperature is lower than 50 degrees C. Push steam button again to stop the
steamer and the indicator lamp goes out (to avoid affecting the water fill level of the steamer, don’t use the massage jet
system when using steamer).
(2) Hydraulic Massage Function
Press round massage button, the indicator lamp is on, massage through auto-cycle pressure jet
(upper, middle and lower parts respectively) and the function will not be controlled by time.
Press square button for directed massage. Press round button again to stop massage system.
(3) Shower Function
Press shower button to start pressure jet shower from the top Press the button again to stop the shower.
(5) Press round ON button, then press CD/FM button to select FM or an external CD player. To set the
station, press use TUN (tuner button) button to select. The volume can be adjusted by pressing the
VOL buttons. Press the round ON / OFF button to turn off the radio.
(6) Shower Light and Fan
Both the light and fan can be controlled by their respective control buttons illustrated here
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected]
Scandia E 100R Control Panel
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected]
Scandia E 100R Maintenance & Troubleshooting Guide
You can keep your E 110R like new for many year by following a few simple rules.
Water Filtration The most important consideration is the quality of water in your area. If your water supply has a high sulfur, chlorine, limestone or other high-mineral content, it is recommended that a water filter is placed before both hot and cold water inlets. Be sure to change the filter at least every three months. Such filter will reduce or eliminate harmful buildup on the steam heating coils and reduce possible discoloration of the acrylic panels. This filter will also ensure a clean and pleasant steam bath experience.
Cleaning the Acrylic Panels NOTE: do not use an abrasive household cleaning product, this will scratch the surface. Use a mild liquid detergent to clean the panels. For polishing purposes you can use any non-abrasive car polish (preferably #10) or any other solution designed for acrylic.
Cleaning the Glass Walls/Doors Use any off-the-shelf glass cleaning product that does not contain ammonia or any acid-based solvent.
Cleaning the Shower Head In the event minerals begin to block your shower head. Remove, disassemble and soak in a vinegar/water solution for 24 hours. Do not use a wire brush for this will damage the nozzle.
Repairing the Acrylic Panels Scratches in your acrylic panels can be buffed out with #600 grit sand paper and followed with an acrylic polish paste application. Cracks and significant damage can be repaired on-site by a shower repair professional. Search your local phone book under the BATHROOM/SHOWER heading.
Problem Possible Cause Solutions Control panel does not illuminate or have power
• The control panel fuse is blown. • The GFI breaker has tripped. • The main breaker has tripped.
• Replace the fuse. • Reset GFI breaker. • Reset main breaker.
The steam generator does not work
• The control panel settings are not correct. • The high limit switch has tripped. • The heating element has quit due to mineral build-up. • The heating element has failed. • No water to steam generator. • The system wires are loose or disconnected.
• Review operating instructions and repeat steps.
• Check the high-limit switch and its connections.
• Test and replace heating element. • Check the water supply. • Clean the steam solenoid valve.
Check the connection wires and/or replace solenoid valve.
The controls are illumi- nated but the steam generator produces wa- ter but no steam'
• Water-level probe wire loose or damaged. • Too much mineral build-up on the water level probe.
• Check all connection wires. • De-scale generator heating elements
and probe.
The shower nozzle does not spray water
• The solenoid valve wire is loose or damaged. • The water tap is not turned on. • The water line to system has been turned off.
• Check connections and/or change solenoid valve.
• Turn on water. • Open water line to system.
The shower/jet water pressure is low.
• The main water supply system is off or has limited pressure.
• The filter is plugged.
• Open water-line to system. • Clean or replace water filter.
No sound from the radio • Wire connections are loose/damaged. • The speakers are damaged.
• Check speaker wire connections. • Replace speakers.
The lights do not work • The wire connections are loose/damaged or incorrect. • The bulb is out.
• Check light wire connections. • Replace bulb.
The fan does not work • The connection is incorrect. • The fan motor is damaged.
• Check fan wire connections. • Replace fan motor.
PE Should be performed by an Licensed Electrician Should be performed by an Licensed Plumber
P
P
E
E
E
E
E
E
P
P
E
Seats
Fan
Scandia Mfg P.O. Box 636 Eagle Idaho, USA 83616 www.scandiahealth.com Tel: 877-467-2862 Fax: 208-286-0290 [email protected]