Page 1
Name of presentationby Mr X
ELCONN ENERGY SYSTEMS (INDIA) PVT. LTD
INTELLIGENT ENERGY MANAGEMENT
Page 2
First Page
"Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum."
Why Elconn Energy?
• Reduces energy consumption by up to 25%• Reduces harmonics by up to 90%• Improves power factor by up to 20%• Improves the life expectancy of your
equipment• Comes with guaranteed savings
• Is fully designed and manufactured in India
Page 3
System comprise the following indices
• Reduction in consumed current ranges from 13.18% to 29.68%.
• KVA release ranges from 14.48% to 32.06% • Voltage rise ranges from0.28% to 2.65% • Increase in PF ranges from 6.09% to 27.18%. • Reduction in KW/KWH ( as seen by the consumer) ranges
from 8.84% to 19.57%.
• Reduction in KW/KWH ( as seen by the Utility) ranges from 10.54% to 23.55%.
• Reduction in distribution losses ranges from 1.75% to 8.25%.
• Reduction in voltage unbalance ranges from 3.23% to 75%.
• Reduction in negative current unbalance ranges from 5.76% to 79%
• Reduction in current THD ranges from 23.01% to 52.15%
• Reduction in voltage THD ranges from 15.86% to 45.98%
Page 4
How the Savings Happen?
• Controlled your losses.• Reduced 3rd level harmonics.• Voltage & current optimization• Phase unbalancing• Reduced neutral current• Improving in power factor.• Reducing your copper losses and iron losses
Page 5
PHASE UNBALANCE
Page 6
SURGE
Page 7
Losses in transmitions
Page 8
Second Page
"Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum."
Zig-Zag Configuration
• The two windings for each phase (outer and inner windings) are wound on the same core but in opposite directions.
• The windings are connected in a zig-zag fashion. For instance, the primary winding of R phase may be connected to the secondary of Y, the primary of Y phase would be connected to the secondary of B.
Page 9
Second Page
"Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum."
Zig-Zag Configuration
• Zig-zag transformers are used to filter harmonic currents. Since the transformer has opposing windings, the harmonic currents get cancelled out.
Page 10
Second Page
"Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum."
Page 11
Voltage Optimization
• The Elconn Energy’s Eluma Intelligent Energy Management system will automatically adjust the incoming voltage to suit your requirements.
Page 12
Real Time Monitoring
• The Eltrak Energy Monitoring system provides real time monitoring with trend analysis at no extra charge. Therefore, our clients do not only save energy through the installation of the Eluma Intelligent Energy Management system but can continue to monitor in real time their supply and achieve additional savings through monitoring and targeting (M&T).
Page 13
• In addition, the system stores the following information (every 1 minute):
• KVA per phase• kWh per phase• KVar per phase• Total Kwh (this will match your main
meter reading if Installed at the main incoming supply)
• Total kVA
• Current per phase• Voltage per phase
Real Time Monitoring
Page 14
Real Time Monitoring
• Power Factor per phase• Harmonics (both Voltage and Current)
3rd, 5th, 7th, 9th, 11th,13th and 15th• The Eltrak system can be viewed on-
line and/or through an internal network and has its own IP address.
Page 15
Why Energy Monitoring?
• The Eltrak Energy Monitoring system certainly provides an excellent platform for your company to clearly identify your electricity usage at any time and take action to further reduce this
Page 16
Connectivity
Page 17
CASE STUDY
Page 18
CASE STUDY
BEFORE (WITHAUT ENERGY METER) JAN 2010 AFTER (WITH ENERGY METER)BILL IS-712,869.00 UNITS- 118693MARCH 2010 BILL IS- 628,283.00UNITS- 106725Actual saving in percentage 18.60%On installation of Elconn energy saver
Page 19
CASE STUDY
Page 20
CASE STUDY
Page 21
CASE STUDY
Page 22
OUR CLIENTS
Page 23
THANKS……….
MANOJ A MAURYA