Download - Direct Measurement of the W boson Decay Width at DØ Neeti Parashar

Transcript
Page 1: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 1

Direct Measurement of the W boson Decay Width at DØ

Neeti ParasharNortheastern UniversityBoston, Massachusetts

U.S.A.

DPF Meeting, College of William and Mary, VA, USA.

24 May, 2002

Page 2: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 2

Outline

Introduction Event Selection Monte Carlo Simulation Background Estimation W Width Determination Systematic Uncertainty Conclusions

Page 3: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 3

Introduction

W decay width, W , is an important parameter in the Standard Model (SM)

In pp collisions, W’s are produced by process: ud Wdecay leptonic: W l; l = e,

hadronic: W q’q; q’ or q = u, d, s,c or b (not t)Considering 3 color charges, total of 9 decay channels

yield a total width of ~ 9(W e)

Including QCD corrections, the SM prediction for the full width is given by

0025.00921.2 W GeV

Page 4: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 4

Introduction

Indirect measurement

Assumes W coupling to lepton to determine (W e)

(W)/(Z) from theory and Br(Z0 ee) from LEP

Measured by UA1, UA2, LEP, CDF, DØ

DØ result (2000):

CDF result (1995):

)(

)(

)(

)(R

00

eeZBr

eWBr

XZpp

WXpp

)(

)()(

W

eWeWBr

084.0064.2 W

GeV079.0169.2 WGeV

Motivation for Direct Measurement a test of SM a probe for possible new physics

Page 5: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 5

Direct Measurement

The total decay width, W, of the W could be measured by the transverse mass mT of We

mT spectrum is sensitive to the W decay width, particularly in the high end

Theoretical input of (W)/(Z) not required

Radiative corrections to W can be observed

))cos(1(2 eT

eT ppm T

Page 6: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 6

Event Selection

W e event selection1994-1995 Run I data, 85 pb-1

“Loose” ElectronsFiducial region: ||< 1.1 in central

calorimeter (CC)High EM fraction: fem > 0.9

Isolation of EM cluster: fiso< 0.15

Shower shape consistent with that expected for e: 2 < 100

“Tight” Electrons

“Loose” Electrons ANDTrack match: trk < 5

4-variable likelihood (2,trk,fem,fiso) 4vl < 0.25

Missing ET> 25 GeV

pT(W) < 15 GeV

Page 7: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 7

Event Selection

W transverse massA typical W e event in Run I

Total W candidates = 24487

W candidates in mT bins (45, 200) 2447(75, 200) 6286

(90, 200) 319

Page 8: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 8

Zee event selection

To study

Electron Efficiency &

Monte Carlo (MC) simulation

Both electrons are in CC region and “tight”

pt(e) > 25 GeV

Invariant mass of dielectron pair

60 GeV < mee < 120 GeV

Total candidates = 1997

Page 9: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 9

Monte Carlo

A fast Monte Carlo, also used in the W mass analysis Three main steps

W(Z) boson production

For MRSA, β = 0.00852 0.00013 For CTEQ4M, β = 0.00852 0.00012

W(Z) boson decay Include W e

Detector simulation Parameterized simulation Parameters need to be constrained from real data (Zee, π0, etc)

2

24222

2

)(W

W

m

MmMm

m

m

e

dm

d

Page 10: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 10

Background

Multijet events Energy is mis-measured (missing Et)

The other passes electron cuts (fake electron)

Z ee One electron is missing or mis-measured HERWIG Z events and GEANT simulation MC sample passed through W selection cuts Normalized, total = 102

W e Same signature as W e, but at low pt

Included in MC

Three main backgrounds to W e sample

Page 11: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 11

Multijet Background

Method (Data based) Loose sample: N = Ns + Nb

Tight (data) sample: Nt = eNs + jNb

Background in data Nb= j(eN- Nt)/(e-j) The difference between loose and tight

samples is the e requirement cuts

Efficiencies e: electron efficiency

Use Zee data e=0.8633 ±0.0118

j: jet efficiency Use non-isolated data without missing Et requirement Calculate j in low missing Et region (0-10 GeV) j = 0.0583 ±0.0016

Page 12: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 12

Inclusive number

368±32

In 90 <mT< 200 GeV

25.4±2.2

Background distribution vs. mT

Smooth background with exponential function in tail

33

2210)( xaxaxaaexf

Multijet Background

Page 13: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 13

Fast MC simulationGenerate W e events with different W

Run through W selection cutsNormalize MC to data with background subtractedAdd background

QCD backgroundZee background

Calculate likelihood for different W

Calculate likelihood data vs. MC

Find W at maximum likelihood

Find statistical uncertainty

W Determination

Page 14: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 14

W Determination

For fitting region mT(90,200) with 319 events

W =2.231+0.145/-0.138 GeV

2=22.6/22 and Kolmogorov-Smirnov test, k = 0.434

Page 15: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 15

Uncertainties

Parameter Value (MeV)

Hadronic Energy Resolution 0.49 0.14 55

Electron Energy Scale 0.95450.0008 41

Background (ensemble) N=40 39

Luminosity slope dependence (8.52 0.12)E-3 28

Electron Energy Resolution 0.0115 +0.0027-0.0036 27

PDF(MRSA, MRST, CTEQ5M, CTEQ4M) - 27

Hadronic Energy Scale 0.6930.060 22

Background (uncertainty) - 15

W mass 80.436 0.037 15

Wpt theory 0.58 0.06 12

Radiative corrections 0.3 0.1 10

Angular calibration of e trajectory 0.998 0.001 10

Selection bias - 9

Systematic Uncertainty - 99

Statistical Uncertainty - +145 / -138

Total Uncertainty - +176 / -170

Page 16: Direct Measurement of the  W  boson Decay Width at DØ Neeti Parashar

N. Parashar 16

DØ Direct W width measurement

(hep-ex/0204009, submitted to PRD)

Consistent with SM

CDF+D0 direct measurement (preliminary)

Preliminary world average

Conclusions

105.0115.2 W

069.0135.2 W

0025.00937.2 W

175.0170.0

145.0138.0

231.2

.)(099.0.)(231.2

W

W sysstat

GeV

GeV

GeV

GeV