PROFISAFE SDK
Data sheet
1 Description
Safety-related automation devices with PROFINET
interface require a certified safety layer. PROFIsafe is thecommunication profile for functional safety applications
based on PROFINET. PROFIsafe can be used in safety-
related applications up to SIL 3/SIL CL 3 according to
IEC 61508/IEC 62061, safety category 4 or PL e according
to ISO 13849-1.
Phoenix Contact provides the PROFIsafe F-Host/F-Device
layer as ANSI C source code. The source code is certified
and protected against manipulation using a CRC check-
sum.
Features
– Certified according to PROFIsafe specification 2.61
– Independent of hardware and operating system
– PROFIsafe CRC calculation using a lookup table or
formula
– Transition T9 of the F-Host state machine supported
2 Scope of delivery
– PROFIsafe F-Host (ANSI C source code);
library: CRC-protected– PROFIsafe F-Device (ANSI C source code);
library: CRC-protected
– PROFIsafe header (ANSI C source code)
– Samples (ANSI C source code)
– Templates for an exemplary F-Host
– Templates for an exemplary F-Device
– Documentation
– PROFIsafe F-Host integration guide
– PROFIsafe F-Device integration guide
Make sure you always use the latest documentation.
It can be downloaded at phoenixcontact-software.com.
PROFIsafe Software Development Kits for F-Hostand F-Device
8/18/2019 Db en Profisafe Sdk 106857 en 00
http://slidepdf.com/reader/full/db-en-profisafe-sdk-106857-en-00 2/2
PROFISAFE SDK
106857_en_00 2 / 2PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germanyphoenixcontact.com
3 Technical data
PROFIsafe
F-Host functionality using PROFINET According to PROFIsafe specification 2.61 and IEC 61784-3-3 profile part,F-Host
F-Device functionality using PROFINET According to PROFIsafe specification 2.61 and IEC 61784-3-3 profile part,F-Device
General requirements
Development process The development process for safety-related automation devices needs to beconfigured according to the rules of IEC 61508, EN 62061, andEN ISO 13849.
Hardware platform Using a two-channel system, the PROFIsafe layer must be implemented oneach channel and executed during runtime.
PROFINET interface The PROFINET interface used is based on certified technology componentsfrom Phoenix Contact.
System time base 1 ms
Available products
PROFIsafe Software Development KitPROFIsafe V2.6 F-Host SDK 1.0 PROFIsafe layer F-Host for implementation in safety-related PROFINETcontrollers
PROFIsafe V2.6 F-Device SDK 1.0 PROFIsafe layer F-Device for implementation in safety-related PROFINETdevices
Additional PROFINET technology components
PROFINET Software Development Toolkits (software stacks) – PROFINET SDK Controller
– PROFINET SDK Device
PROFINET device interface – Single chip device interface TPS-1
– TPS-1 Development Toolkit
Configuration software PROFINET Configurator
Top Related