It is always recommended to anchor the unit to the ground. Drill through the four holes in the base of the unit using 6mm dia masonry drill to a depth of 70mm. Screw in the anchor fixings. (These have a self cutting thread). If not anchoring the unit, fit the self seal plugs BEFORE BUILDING to seal the fixing holes from underneath. Please note product must be bolted down to comply with LPS1175.
TOOLS REQUIREDPower driver POSI-DRIV screwdriver, 6mm dia. masonry drill and a13mm socket or spanner.
CENTURION
LH F. SIDE PANEL
32941 x1
LH R. SIDE PANEL
32874 x1
F. BASE PANEL
32940 x1
R. BASE PANEL
32871 x1
LH
DO
OR
3294
3 x1
RH
DO
OR
3294
4 x1
FRONT FASCIA32948 x1
ZSC
REW
32 x
8
ZSIL
CO
1 x
1
ZSC
REW
04 x
4
ZSC
REW
100
x18
4
ZSC
REW
340
x24
3267
0 x
16
13mm Spanner
18V
ZCO
MPP
LZS0
2 x
8
ZCO
MPP
LAS2
2-23
-24
x12
4x 2
mm
, 4x
3mm
, 4x
5mm
BASE
CO
VER
CH
ANN
EL 3
7364
x1
SID
E C
OVE
R C
HAN
NEL
329
16 x
2
RO
OF
CO
VER
CH
ANN
EL 3
2918
x2
F. TOP PANEL
32986 x1
TOP SHROUD
32945 x2
R. TOP PANEL
32987 x1
RH F. SIDE PANEL
32942 x1
RH R. SIDE PANEL
32875 x1
BASE INSTRUCTIONSFlat and firm base. Recommended: concrete, tarmac or paving flags. Min. distance from walls/ shrubbery: 1000mm.Min. base size (WxDxH) 2640mm x 1730mm x 50mm.
LEVELING THE UNITCorrectly level the constructed unit using the shims (ZCOMPPLAS) provided prior to fixing the unit to the ground. Slide the packing pieces under the corners of the unit base as required until an equal gap has been achieved around the door allowing for its smooth operation and alignment.
LH
BAC
K PA
NEL
3286
7 x1
RH
BAC
K PA
NEL
3287
6 x1
For maintenance instructions of this product visit www.asgardsss.co.uk
Warning: some panels may weigh over 20KgBeware of manual handling
Warning: Please keepthis key card safe! Referto if replacement key is required.
x2
SEAL
ANT
00001
YOUR UNIQUEKEY CODE
ROOF JOINT
STRIP 40446 x2
6mm Dia.
Posi-DrivScrewdriver
RH
BAC
K PA
NEL
3287
6
RH
R. S
IDE
PAN
EL32
875
REAR BASE PANEL
32871
x15
1
3
5 6
4
2
x19 x22
x10
PLEASE NOTE ALL SCREWS ARE FIXED FROM THE INSIDE
LH R
. SID
E PA
NEL
3287
4
x16 x13
R. T
OP
PAN
EL32
987
F. BASE PANEL
32940 x1
LH B
ACK
PAN
EL32
867
x15
x3
x7
x3
x16
x7
x15
x13
x4
x4
x4x4
7 8
9 10
11 12
x34 x6
x30 x24
x4 x4
LH F
. SID
E PA
NEL
3294
1
RH F. SIDE PANEL
32942
FRO
NT
FASC
IA32
948
F. TOP PANEL
32986
LH D
OO
R32
943
RH
DO
OR
32
944
1ST TOP SHROUD
32945
2ND TOP SHROUD
32945
SHROUDS 32945
x15
x3
x3
x15
x7
x7
x4x4
x4
x4 x7
x7
x2
x2
x4
x3
x3
x3
x3
x3
x3
x3
x3
SHROUDS
ROOF STRIP
ROOF JOINT STRIP 40446
APPLY TO BOTH
ROOF JOINT STRIP 40446
ROOF JOINT STRIP END40446
13 14
15 16
www.asgardsss.co.uk
x16
x8
REMOVE SCREWS WHICH ALIGNWITH THE COVER CHANNELS. ALIGN AND PLACE SCREWS BACK!
REMOVE SCREWS WHICH ALIGNWITH THE COVER CHANNELS. ALIGN AND PLACE SCREWS BACK!
SID
E C
OVE
R C
HAN
NEL
329
16
BASE
CO
VER
CH
ANN
EL 3
7364
033015/03.08.15/KW/REV4
RO
OF
CO
VER
CH
ANN
EL 3
2918
3267
0
Top Related