Download - A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data

Transcript
Page 1: A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data

European Instituteof Molecular Imaging

A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data

M Dawood, C Brune, X Jiang, F Büther, M Burger, O Schober, M Schäfers, KP Schäfers

Department of Computer Science,European Institute for Molecular Imaging

University of Münster, Germany

Page 2: A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data

2

European Instituteof Molecular Imaging Motion Correction on 3D PET/CT Data with Optical Flow Algorithms

PET, Minutes

CT, Seconds

Acquisition Times

Page 3: A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data

3

European Instituteof Molecular Imaging Motion Correction on 3D PET/CT Data with Optical Flow Algorithms

Gating

Page 4: A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data

4

European Instituteof Molecular Imaging Motion Correction on 3D PET/CT Data with Optical Flow Algorithms

Mass conserved in cardiac data

Systole FDG-PET 1 h.p.i. non-AC Diastole

Continuity Equation:

Page 5: A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data

5

European Instituteof Molecular Imaging Motion Correction on 3D PET/CT Data with Optical Flow Algorithms

Motion vectors

Page 6: A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data

6

European Instituteof Molecular Imaging Motion Correction on 3D PET/CT Data with Optical Flow Algorithms

All gates deformed to Diastole

Visual result

Cardiac phases

Page 7: A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data

7

European Instituteof Molecular Imaging Motion Correction on 3D PET/CT Data with Optical Flow Algorithms

Quantitative results 1: Correlation with target phase

Page 8: A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data

8

European Instituteof Molecular Imaging Motion Correction on 3D PET/CT Data with Optical Flow Algorithms

Quantitative results 2: Myocardial thickness

Page 9: A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data

9

European Instituteof Molecular Imaging Motion Correction on 3D PET/CT Data with Optical Flow Algorithms

Quantitative results 3: Time activity curves in blood pool

Page 10: A Continuity Equation Based Optical Flow Method for Cardiac Motion Correction in 3D PET Data

10

European Instituteof Molecular Imaging Motion Correction on 3D PET/CT Data with Optical Flow Algorithms

Thank you