www.grassvalley.com
APPLICATION NOTE1 RU BROADLINX CHASSIS INSTALLATION REQUIREMENTSLee BuchananDavid BlairJune 2014
This document provides guidance for upgrading existing Grass Valley Trinix 512x512 systems based on the 4 RU Unipower power supply chassis to the latest 1 RU BroadLinx chassis and 1 RU Lineage power supply chassis.
1 RU BROADLINX CHASSIS INSTALLATION REQUIREMENTS
www.grassvalley.com 2
TABLE OF CONTENTS
BACKGROUND: TRINIX DV-33512/NXT-512X512 BROADLINX AND POWER INTERCONNECTS ...... 3
4 RU Unipower Chassis (TRX-PS-33500) .......................................................................................................................... 4
1 RU Unipower Chassis (TRX-PS-BU1200/BU2400/BU3600) ............................................................................................ 6
1 RU Lineage Tertiary Power Supply Chassis (TRX-PSFRM-TER-1 RU) ........................................................................... 7
1 RU Lineage Power Supply Chassis (TRX-PSFRM-1 RU) ............................................................................................... 8
PLANNING: TRINIX DV-33512/NXT-512X512 1 RU BROADLINX DEPLOYMENT REQUIREMENTS . 10
DV-33512 with 1 RU BroadLinx Chassis and 1 RU Power Supplies .................................................................................10
NXT-512x512 with 1 RU BroadLinx Chassis and 1 RU Power Supplies ...........................................................................11
IMPLEMENTATION: TRINIX DV-33512/NXT-512X512 TO 1 RU BROADLINX UPGRADE PATH ........ 12
TRX-BL-FRM-1 RU ............................................................................................................................................................. 12
1 RU BROADLINX CHASSIS INSTALLATION REQUIREMENTS
www.grassvalley.com 3
INTRODUCTION
BACKGROUND: TRINIX DV-33512/NXT-512X512 BROADLINX AND POWER INTERCONNECTS
For enhanced serviceability, Grass Valley Trinix digital video routers now support 1 RU BroadLinx—Grass Valley’s web-based status and monitoring solution. The 1 RU BroadLinx option combines network interface, sync input and output monitor circuitry, allowing LAN-based control by Encore/SMS and system monitoring function via Microsoft Internet Explorer. SNMP/NetCentral system monitoring is also available.
However, prior to deploying the 1 RU BroadLinx, users need to plan and provision their Trinix digital video routers, chassis and power supplies to accommodate the updated interconnects.
This document provides guidance for upgrading existing Trinix 512x512 systems based on the 4 RU Unipower power supply chassis to the latest 1 RU BroadLinx chassis and 1 RU Lineage power supply chassis. The document is split into three sections:
a) Background: Trinix DV-33512/NXT-512x512 BroadLinx and power interconnects
b) Planning: Trinix DV-33512/NXT-512x512 required connectivity to deploy the 1 RU BroadLinx-based system
c) Implementation: Trinix DV-33512/NXT-512x512 upgrade path to the 1 RU BroadLinx
There are also variations in the power supply chassis used with Trinix 512x512 systems. Four different models of power supply chassis have been made commercially available:
• 4 RU Unipower Chassis (TRX-PS-33500)
• 1 RU Unipower Chassis (TRX-PS-BU1200/BU2400/BU3600)
• 1 RU Lineage Tertiary Power Supply Chassis (TRX-PSFRM-TER-1 RU)
• 1 RU Lineage Power Supply Chassis (TRX-PSFRM-1 RU)
Trinix 512x512 systems have been commercially available in two different models: the DV-33512 and the NXT-512x512. These chassis are very similar but vary with respect to the manner in which external power is connected to the system. The two power terminal variants are:
• DV-33512 with DC terminal lug input
• NXT-512x512 with circular DC input
DV-33512 with DC terminal lug input NXT-512x512 with circular DC input
BACKGROUND: TRINIX DV-33512/NXT-512X512 BROADLINX AND POWER INTERCONNECTS (CONT.)
1 RU BROADLINX CHASSIS INSTALLATION REQUIREMENTS
www.grassvalley.com 4
4 RU Unipower Chassis (TRX-PS-33500)
• 751-0090-02; ASSY POWER SUPPLY CHASSIS ONLY (NO PS)
• 731-0132-00 (QTY=2) or 731013201 (QTY=2)
—731-0132-00; ASSY DC POWER CABLE PS-33500
BACKGROUND: TRINIX DV-33512/NXT-512X512 BROADLINX AND POWER INTERCONNECTS (CONT.)
1 RU BROADLINX CHASSIS INSTALLATION REQUIREMENTS
www.grassvalley.com 5
—731-0132-01 (QTY=1); ASSY DC POWER CABLE TRINIX NXT 512
• 174-8187-00 (QTY=1); Cable, Shld Patch Cord 4PR STRD RJ45 10FT
• 731-0088-00 (QTY=1); Assy RF-33500 PS Intf Cable
BACKGROUND: TRINIX DV-33512/NXT-512X512 BROADLINX AND POWER INTERCONNECTS (CONT.)
1 RU BROADLINX CHASSIS INSTALLATION REQUIREMENTS
www.grassvalley.com 6
1 RU Unipower Chassis (TRX-PS-BU1200/BU2400/BU3600)
• 862-773-50; VCONV - EQPT,RACK 1 RU 3X PWR SPLY 15A IE
• 731-0044-01 (QTY=1); ASSY CABLE TRINIX BACKUP
BACKGROUND: TRINIX DV-33512/NXT-512X512 BROADLINX AND POWER INTERCONNECTS (CONT.)
1 RU BROADLINX CHASSIS INSTALLATION REQUIREMENTS
www.grassvalley.com 7
1 RU Lineage Tertiary Power Supply Chassis (TRX-PSFRM-TER-1 RU)
• 751-0326-01 (QTY=1); ASSY,PS RACK FRAME TRINIX
• 731-0270-00 (QTY=1); ASSY TRX NXT DC POWER CABLE RY
BACKGROUND: TRINIX DV-33512/NXT-512X512 BROADLINX AND POWER INTERCONNECTS (CONT.)
1 RU BROADLINX CHASSIS INSTALLATION REQUIREMENTS
www.grassvalley.com 8
1 RU Lineage Power Supply Chassis (TRX-PSFRM-1 RU)
• 751-0326-00 (QTY=1); ASSY,PS RACK FRAME TRINIX
BACKGROUND: TRINIX DV-33512/NXT-512X512 BROADLINX AND POWER INTERCONNECTS (CONT.)
1 RU BROADLINX CHASSIS INSTALLATION REQUIREMENTS
www.grassvalley.com 9
• 86229200 (QTY=1); ASSY DC POWER CABLE TRINIX NXT 512
• 731-0265-00 (QTY=1); ASSY CNTL INTERFACE CABLE TRINIX
PLANNING: TRINIX DV-33512/NXT-512X512 1 RU BROADLINX DEPLOYMENT REQUIREMENTS
1 RU BROADLINX CHASSIS INSTALLATION REQUIREMENTS
www.grassvalley.com 10
The 1 RU BroadLinx chassis and 1 RU power supplies require one of the two following configurations based on Trinix chassis (DV-33512 or NXT-512x512):
DV-33512 with 1 RU BroadLinx Chassis and 1 RU Power Supplies
These chassis are comprised of a Trinix DV-33512 chassis, 1 RU BroadLinx chassis (with BroadLinx cards) and two 1 RU Lineage power supply chassis (with 1200W power supplies) which are interconnected as follows:
• Main power cable(s) (731-0270-00; ASSY TRINIX NXT EXT DC POWER CABLE) from 1 RU Lineage power supply chassis to DV-33512 chassis via socket to terminal block connectors.
• Secondary power cable(s) (731-0341-00; CBL,ASSY,TRX-BL-FRM-1
RU PWR) from 1 RU Lineage power supply chassis to 1 RU BroadLinx chassis via terminal block to socket connectors.
• “PM Bus” cable(s) (731-0265-00; ASSY CNTL INTERFACE CABLE TRINIX) from 1 RU Lineage power supply chassis to 1 RU BroadLinx chassis via Header to D-type connectors.
• “IFC” cable (731-0343-00; ASSY CABLE IFC TRX512 TO TRX-BL-FRM-1 RU) from 1 RU BroadLinx chassis to DV-33512 chassis via D-type to D-type connectors.
• “Com Bus” cable(s) (174-8187-00; CABLE,SHLD PATCH CORD 4PR STRD RJ45 10FT) from 1 RU BroadLinx chassis to DV-33512 via RJ-45 connectors.
• LAN cables(s) (not provided) from 1 RU BroadLinx chassis to management network via RJ-45 connectors.
1 RU Power Supply
1 RU Power Supply
1 RU Broadlinx
TrinixDV-33512
731
-027
0-00
174-
8187
-00
731-
0343
-00
731-
0265
-00
731-0341-00
731-0341-00
731-
0265
-00
731
-027
0-00
PLANNING: TRINIX DV-33512/NXT-512X512 1 RU BROADLINX DEPLOYMENT REQUIREMENTS (CONT.)
1 RU BROADLINX CHASSIS INSTALLATION REQUIREMENTS
www.grassvalley.com 11
NXT-512x512 with 1 RU BroadLinx Chassis and 1 RU Power Supplies
These systems are comprised of a Trinix NXT-512x512 chassis, 1 RU BroadLinx chassis (with BroadLinx cards) and two 1 RU Lineage power supply chassis (with 1200W power supplies) which are interconnected as follows:
• Main power cable(s) (86229200; ASSY DC POWER CABLE) from 1 RU Lineage power supply chassis to NXT-512x512 chassis via socket to terminal block connectors.
• Secondary power cable(s) (731-0341-00; CBL,ASSY,TRX-BL-FRM-1 RU PWR) from 1 RU Lineage power supply chassis to 1 RU BroadLinx chassis via terminal block to socket connectors.
• “PM Bus” cable(s) (731-0265-00; ASSY CNTL INTERFACE CABLE TRINIX) from 1 RU Lineage power supply chassis to 1 RU BroadLinx chassis via Header to D-type connectors.
• “IFC” cable (731-0343-00; ASSY CABLE IFC TRX512 TO TRX-BL-FRM-1 RU) from 1 RU BroadLinx chassis NXT-512x512 chassis via D-type to D-type connectors.
• “Com Bus” cable(s) (174-8187-00; CABLE,SHLD PATCH CORD 4PR STRD RJ45 10FT) from 1 RU BroadLinx chassis to DV-33512 via RJ-45 connectors.
• LAN cables(s) (not provided) from 1 RU BroadLinx chassis to management network via RJ-45 connectors.
1 RU Power Supply
1 RU Power Supply
1 RU Broadlinx
TrinixNXT-512x512
8622
9200
174-
8187
-00
731-
0343
-00
731-
0265
-00
731-0341-00
731-0341-00
731-
0265
-00
8622
9200
IMPLEMENTATION: TRINIX DV-33512/NXT-512X512 TO 1 RU BROADLINX UPGRADE PATH
1 RU BROADLINX CHASSIS INSTALLATION REQUIREMENTS
www.grassvalley.com 12
The 1 RU BroadLinx chassis is available in the following package:
TRX-BL-FRM-1 RU
• 751-0339-01 (QTY=1); ASSY, CHASSIS 1 RU BLINX
Note: The wires connecting to terminal lugs L3 and L4 have black shrink sleeve. The red wires on L1 and L2 indicate the positive connections (+48v) and the black-sleeved wires to L3 & L4 indicate the negative connections (-48V).
• 731-0341-00 (QTY=2); CBL,ASSY,TRX-BL-FRM-1 RU PWR
125
X.X .030" (.75mm) X.XX .015" (.35mm) X.XXX .005" (.12mm) ANGULAR 0.5°
4X 3" 76.2mm
7" 177.8mm
10.0'[3.048m]
L1
L2
L3
L4
L5
1 6X 2
9 9
7
4
3
5
68
10
654
321
J1
10. BAG AND TAG, ITEMS 9-11 ONTO GND CABLE (L5)
9. SHRINK TUBE OVER EXPOSE DRAIN WIRE
8. PACKAGE IN ANTI_STATIC BAG
7. STAMP OR LABEL WITH GV PART NUMBER
6. ALL DIMENSIONS ARE IN INCHES AND ARE FINISHED DIMENSIONS.
5. MATERIAL AND PACKAGING MUST BE MARKED WITH A RoHS COMPLIANCE MARKINGAND LABELIN
4. MATERIAL AND FINISH MUST BE A RoHS COMPLAINT
3. MANUFACTURE'S UL RECOGNITION LABEL AND CSA CERTIFICATION FORM/LATTER MUST BE PROVIDED WITH ALL SHIPMENT
2. PART MUST BE MANUFACTURED BY A UL RECOGNIZED AND CSA CERTIFIED WIRE HARNESS MFG. MATERIAL AND PROCESS MUST MEET UL AND CSA REQUIREMENTS.
1. DIMENSIONING AND TOLERANCING PER ASME Y14.5M-2009
NOTES: UNLESS OTHERWISE SPECIFIED
LIST OF MATERIALITEM QTY PART NUMBER MFG MFG PN DESCRIPTION
1 1 131-7605-00 MOLEX INC 39-01-2065 CONN,RCPT 6 POS MINI FIT
2 6 131-6931-00 MOLEX INC 39-00-0090 CONN,CNT FEMALE 16 AWG CRIMP
3 1 TA6315-10 PANDUIT PN14-10R-3K TERM, RING 14-16 AWG #10 STUD INSUL
4 4 131-8382-00 TE CONNECTIVITY 2-320563-2 TERM RING LUG #1/4 STUD 16-14 AWG
5 AR 176-0532-00 ALPHA WIRE CORP 85604CY CABLE,4 COND 16AWG W/SHIELD
6 AR 162-0016-00 RAYCHEM INC VERSAFIT-1/2-0 HEAT SHRINK, 1/2 INCH, BLACK
7 AR 162-0015-00 RAYCHEM INC VERSAFIT-1/8-0 HEAT SHRINK, 1/8 INCH, BLACK
8 AR 162-0027-00 3M FP-301-3/4-Black-48" HEAT SHRINK, 3/4 INCH, BLACK
9 1 22-008523-135 -------- -------- SCW PFH 10-32X3/8 STL ZC RoHS
10 1 004-5336-00 LANDSBERG 103343 POLY BAG, RECLOSABLE 3X5" 2 MIL
11 1 334-9882-00 BRADY USA LAT-6-747-10 LABEL, BLANK ADH BACKING IDENT 1/4"XL"
WIRE DIAGRAMWIRE NUMBER FROM TO COLOR NOTES
1 J1-3 L1 RED #1 POSITIVE 48V A
2 J1-6 L2 RED #2 POSITIVE 48V B
3 J1-1 L3 RED #3 NEGATIVE 48V A4 J1-4 L4 YEL/GRN NEGATIVE 48V B5 J1-2 L5 BRAID GROUND SHIELD
6 J1-5 L5 BRAID GROUND SHILED
REVISIONS
ECO REV. DESCRIPTION DATE APPROVED
609-7C A1 INITIATED PART 24JAN14
D
C
B
A
B
C
D
12345678
8 7 6 5 4 3 2 1
E
F
E
F
A
SHEET 1 OF 1
CAD FILE A1THIRD ANGLE
MFG
-
QA
NONE WT:
07AUG13
07AUG13
DRAWN
DATEENG
DATE
06-731-0341-00.SLDDWGC
CBL, ASSY, TRX-BL-FRM-1RU PWR
PROPRIETARY NOTE:
GENERAL TOLERANCES(UNLESS OTHERWISE SPECIFIED)
SCALE:
6KG60REVDRAWING NO.PREFIXCAGE CODE
DATE-
DATE
06SIZE
P. HER
P. HER
-
731-0341-00
125
X.X ± .030" (.75mm)X.XX ± .015" (.35mm)X.XXX ± .005" (.12mm)ANGULAR ± 0.5°
D
C
B
A
B
C
D
12345678
8 7 6 5 4 3 2 1
E
F
E
F
A
SHEET 1 OF 1
CAD FILE B1THIRD ANGLE
NONE WT:
DRAW
ENG
DATE
C
PROPRIETARY NOTE:
GENERAL TOLERANCES(UNLESS OTHERWISE SPECIFIED)
SCALE:6KG60
REVDRAWING NO.PREFIXCAGE CODE
22SIZE
390-7111-00
Y USA, LLCELLAV SSARG.DR ENIM ECNEDIVORP 004
95959 .AC ,YTIC ADAVEN
MFG
QA
DATE
DATE
DATEThis drawing contains information proprietary to Grass Valley USA, LLC, and when distributed outside Grass Valley USA, LLC, is supplied for identi�cation, engineering evaluation and/or inspection purposes only and may not be used as a basis for manufacture or sales of products without written permission from Grass Valley USA, LLC. If this drawing is furnished under any United States government contract, it is furnished as limited rights data and shall not be released outside the government, or used, duplicated, or disclosed in whole or in part for manufacture or procurement without the written permission of Grass Valley USA, LLC, except for: (1) Emergency repair or overhaul of work by or for the government, where the item or process concerned is not otherwise reasonably available to enable timely performance of the work, or (2) release to a foreign government as the interests of the United States may require, provided that in either case the release, use, duplication or disclosure hereof shall be subject to the foregoing limitations. The limited rights claimed herein are not subject to an expiration date. If this drawing is reproduced in whole or in parts, this entire legend block must appear on all reproduced copies. Copyright Grass Valley USA, LLC. All rights reserved.
REVISIONS
PRODUCTION RELEASED
ECO DFTRREV DATE CHK BY
A1 TD 03FEB14
REAR PANEL 1RU TRINIXBL ARTWORK
T DOUN
T DOUN
30JAN14
30JAN14
22-390-7111-00.ai
This PDF accurately represents the actual silkscreen art and its placement on the part. However, due to scaling errors, this PDF must only be used to review silkscreen content and placement. USE THE CORRESPONDING .eps FILE TO CREATE THE SILKSCREEN.
656-7C
ARTWORK CHANGED TO MEET SAFETY REQUIREMENTS
B1 TD 27MAR14671-7C
-+
48VD
C @
1.5
AM
P
A
B
G
-+ G
REF IN1
2
PRIM
ARY
CONSOLE A
COM BUS SECO
NDAR
Y
NIC A1
PMBUS A
XPT
BUS
REF IN1
2
CONSOLE B
COM BUS
NIC B1
PMBUS B
FRAME IFC
GPIO/TC
ALM
REAR PANEL 1RU TRINIX BL ARTWORK
30JAN14BROADLINK
390-7111-00
100% BLACK, PER STD-018
B1PART NUMBER
TITLE
SILKSCREEN COLOR
REV USED ON DESIGNER
DATE
TD
FILM NUMBER REV
390-7111-00 7
_ _
_
-+
48VD
C @
1.5
AM
P
A
B
G
-+ G
REF IN1
2
PRIM
ARY
CONSOLE A
COM BUS SECO
NDAR
Y
NIC A1
PMBUS A
XPT
BUS
REF IN1
2
CONSOLE B
COM BUS
NIC B1
PMBUS B
FRAME IFC
GPIO/TC
ALM
_ _
_
• 731-0343-00 (QTY=1); ASSY CABLE IFC TRX512 TO TRX-BL-FRM-1 RU
1 RU BROADLINX CHASSIS INSTALLATION REQUIREMENTS
Copyright © 2014 Belden Inc. All rights reserved. Belden, Belden Sending All The Right Signals, Grass Valley, Trinix, BroadLinx and the Belden logo are trademarks or registered trademarks of Belden Inc. or its affiliated companies in the United States and other jurisdictions. All other tradenames referenced are service marks, trademarks, or registered trademarks of their respective companies. Specifications subject to change without notice. RMC-6039M
ABOUT GRASS VALLEY
The new Grass Valley keeps broadcasters, content owners and service providers future-ready as they navigate the changing landscape of television. With the most comprehensive collection of workflow solutions in the industry, Grass Valley delivers end-to-end television production and content distribution workflows that enable the efficiency and flexibility broadcasters need to stay competitive today—while offering technological foresight they need to keep pace with consumers’ desires for more content on more devices. Grass Valley, headquartered in Montreal, leverages the collective expertise and depth of the Grass Valley Group and Miranda Technologies, each having been acquired by St. Louis-based
Belden Inc. Belden delivers a comprehensive product portfolio designed to meet the mission-critical network infrastructure needs of industrial, enterprise and broadcast markets. With innovative solutions targeted at reliable and secure transmission of rapidly growing amounts of data, audio and video needed for today’s applications, Belden is at the center of the global transformation to a connected world. For more information visit www.belden.com.
For information about Grass Valley solutions and services, please visit www.grassvalley.com.
Join the Conversation at
GrassValleyLive on Facebook,
Twitter and YouTube.
IMPLEMENTATION: TRINIX DV-33512/NXT-512X512 TO 1 RU BROADLINX UPGRADE PATH (CONT.)
125
X.X .030" (.75mm) X.XX .015" (.35mm) X.XXX .005" (.12mm) ANGULAR 0.5°
10.00 ft
A
P1 P2
3
7 76 36X 5 2 36X 1
DETAIL A SCALE 3 : 1
4 8
(TWO PLACES)
15 3014 44 2913 43 2812 42 2711 41 2610 40 25 9 39 248 38 237 37 226 36 215 35 204 34 193 33 182 32 171 31 16
NOTES: UNLESS OTHERWISE SPECIFIED
1. ALL PARTS PER PRINT OR EQUIVALENT. EQUIVALENT PARTS CAN BE USED ONLY WITH PRIOR GRASS VALLEY APPROVAL.
2. DO NOT SCALE DRAWING.
3. LABEL EACH BAG WITH PART NUMBER, REVISION AND UL RECOGNITION LABEL.
4. TOLERANCES: +/-.25 INCHES UNLESS NOTED.
5. DIMENSIONS ARE IN INCHES, 6. USE ONLY ANTI-STATIC BAGS.
7. PART MUST BE MANUFACTURED BY A UL RECOGNIZED AND CSA CERTIFIED WIRE HARNESS MANUFACTURE.
8. INSTALL TWO 2-1/2” PIECES OF SLEEVING (ITEM 4) OVER CABLE ENDS BEFORE INSTALLING PINS AND CONNECTORS INTO BACKSHELL. REFERANCE DOCUMENT FROM NORTHERN TECHNOLOGIES (DWG NO. 0002-080-038) FOR BACK SHELL (ITEM 7) INSTALLATION.
9. MATERIAL, HARDWARE AND FINISHES MUST BE RoHS COMPLIANT.
10. ASSEMBLY OR PACKAGING MUST BE MARKED WITH RoHS COMPLIANCE MARKING OR LABEL.
16 1 31 172 32 183 33 194 34 205 35 216 36 22 7 37 238 38 249 39 2510 40 2611 41 2712 42 2813 43 2914 44 3015
REVISIONS
ECO REV. DESCRIPTION DATE APPROVED
609-7C A1 INITIATED PART 24JAN14
LIST OF MATERIALITEM QTY PART NUMBER MFG MFG PN DESCRIPTION
1 36 131-8439-00 NORTHERN TECH. DCHESX1022AF CONN O/F PIN 22-30 AWG CRIMP
2 1 131-8440-00 NORTHERN TECH. DC3E44ST CONN M/F CABLE 44PIN DSUB
3 10 FT 176-0533-00 BELDEN 9519 CABLE 19 PAIR 24AWG SHLD
4 5 IN 37-003362-009 RAYCHEM RNF-100-3/4 SLVNG SHK IRRD POLYOL 3/4
5 36 131-8441-00 NORTHERN TECH. DCHEPX1022AF CONN O/M PIN 22-30AWG CRIMP
6 1 131-8443-00 NORTHERN TECH. DC3E44PTE CONN F/M CABLE 44PIN DSUB
7 2 131-8442-00 NORTHERN TECH. C88E000203 TWO PIECE METAL STRAIGHT EXIT BACKSHELL WITH COMPRESSION INSERTS
WIRE DIAGRAMWIRE NUMBER CONNECTOR P1 FEMALE
(FROM)CONNECTOR P2 MALE
(TO) COLOR WIRE PAIR NOTES
1 NC NC WHT WHT/BLK NO CONNECTION2 P1-16 P2-31 BLK3 NC NC NO CONNECTION
4 NC NC NO CONNECTION
5 NC NC NO CONNECTION
6 NC NC NO CONNECTION
7 NC NC NO CONNECTION
8 NC NC NO CONNECTION9 P1-17 P2-32 WHT WHT/RED10 NC NC RED11 NC NC WHT WHT/GRN12 P1-19 P2-12 GRN13 P1-5 P2-5 WHT WHT/BLU14 P1-35 P2-35 BLU15 P1-6 P2-6 GRN GRN/YEL16 P1-36 P2-36 YEL17 P1-20 P2-20 GRN GRN/BRN18 NC NC BRN NO CONNECTION19 P1-7 P2-7 BLK BLK/BRN20 P1-37 P2-37 BRN21 P1-8 P2-8 BLK BLK/RED22 P1-38 P2-38 RED23 P1-22 P2-22 BLK BLK/ORN24 P1-23 P2-23 ORN25 P1-9 P2-9 BLK BLK/YEL26 P1-39 P2-39 YEL27 P1-24 P2-24 BLK BLK/GRN28 P1-25 P2-25 GRN29 P1-10 P2-10 BLK BLK/BLU30 P1-40 P2-40 BLU31 P1-11 P2-11 GRN GRN/BLU32 P1-26 P2-26 BLU33 NC NC BLK BLK/GRY NO CONNECTION
34 NC NC GRY NO CONNECTION35 P1-12 P2-13 BRN BRN/RED36 P1-27 P2-21 RED37 NC NC RED RED/ORN NO CONNECTION38 P1-28 P2-28 ORN39 P1-14 P2-14 RED RED/YEL40 P1-29 P2-42 YEL41 P1-15 P2-15 RED RED/GRN42 P1-30 P2-30 GRN43 P1-43 P2-43 RED RED/BLU44 P1-44 P2-44 BLU45 P1-GND P2-GND CBL-GND SEE NOTE 10
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
E
F
E
F
REV
731-
0343
-00
D02
21 A1
11OCT13
DATE-
MFG
GENERAL TOLERANCES(UNLESS OTHERWISE SPECIFIED)
THIRD ANGLE
731-0343-00
-
731-0343-00.SLDDRW
DO NOT SCALE DRAWING
DRAWN
ENGINEER
SIZE
CAGE CODE
PREFIX DRAWING NO. REV
D6KG60 WT
CAD FILE
ASSY CABLE IFC TRX512 TO TRX-BL-FRM-1RU
PROPRIETARY NOTE:
DATEP. HER
P. HER
-
SHEET 1 OF 1
DATE
FINISH
Upgrading DV-33512 systems will require the deployment of the 1 RU BroadLinx chassis (TRX-BL-FRM-1RU), two 1 RU Lineage tertiary power supply chassis (TRX-PSFRM-TER-1RU), two DC power cables (731-0270-00) and a total of 4-6 Lineage power supplies (TRX-PSU-1200W). The Lineage tertiary power supply chassis and power supplies will need to be added to any systems that do not currently have them in place. The 1 RU BroadLinx chassis will need to be added to all systems. If the existing system does not already include two DC power cables (731-0270-00) they will have to be added as well.
Upgrading NXT-512x512 systems will require the deployment of the 1 RU BroadLinx chassis (TRX-BL-FRM-1RU), two 1 RU Lineage power supply chassis (TRX-PSFRM-1RU) and a total of 4-6 Lineage power supply chassis (TRX-PSU-1200W). The Lineage power supply chassis and power supplies will need to be added to any systems that do not currently have them in place. The 1 RU BroadLinx chassis will need to be added to all systems.
Any Unipower tertiary power supply chassis and power supplies should be removed from the system (DV-33512 or NXT-512x512) during the upgrade process.
Top Related