ZXR10 2900E SeriesEasy-maintenance Secure Switch
Hardware Manual
Version: 2.05.10
ZTE CORPORATIONNO. 55, Hi-tech Road South, ShenZhen, P.R.ChinaPostcode: 518057Tel: +86-755-26771900Fax: +86-755-26770801URL: http://ensupport.zte.com.cnE-mail: [email protected]
LEGAL INFORMATIONCopyright © 2011 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by
contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.
Revision History
Revision No. Revision Date Revision Reason
R1.0 2012-07-02 First edition
Serial Number: SJ-20120409144109-001
Publishing Date: 2012-07-02(R1.0)
ContentsAbout This Manual ......................................................................................... I
Chapter 1 Safety Instruction...................................................................... 1-11.1 Safety Instruction ............................................................................................... 1-1
1.2 Safety Signs ...................................................................................................... 1-1
Chapter 2 System Overview ...................................................................... 2-12.1 Product Introduction ........................................................................................... 2-1
2.2 Functions........................................................................................................... 2-2
2.3 Technical Features and Parameters..................................................................... 2-3
Chapter 3 Hardware Descroption.............................................................. 3-13.1 Hardware Structure ............................................................................................ 3-1
3.1.1 ZXR10 2918E .......................................................................................... 3-3
3.1.2 ZXR10 2928E .......................................................................................... 3-8
3.1.3 ZXR10 2952E ........................................................................................ 3-13
3.1.4 ZXR10 2910E-PS................................................................................... 3-18
3.1.5 ZXR10 2918E-PS................................................................................... 3-23
3.1.6 ZXR10 2928E-PS................................................................................... 3-30
3.1.7 Optical Module ....................................................................................... 3-37
3.2 Cables............................................................................................................. 3-39
3.2.1 Power Cable .......................................................................................... 3-39
3.2.2 Protective Cables ................................................................................... 3-42
3.2.3 Serial Console Cable.............................................................................. 3-46
3.2.4 Network Cable ....................................................................................... 3-46
3.2.5 Fiber...................................................................................................... 3-48
Chapter 4 Installation................................................................................. 4-14.1 Desktop Installation ............................................................................................ 4-1
4.2 Cabinet Installation............................................................................................. 4-1
4.3 Cable Laying...................................................................................................... 4-6
4.3.1 Installation Specifications.......................................................................... 4-6
4.3.2 Power-on Procedure................................................................................. 4-7
4.4 Lightning Protection of the Switch(Optional) ......................................................... 4-8
4.4.1 Installation of Lightning Arrester for AC Power ........................................... 4-8
4.4.2 Installation of Lightning Arrester for Network Port ....................................... 4-9
Figures............................................................................................................. I
I
Tables ............................................................................................................ III
II
About This ManualPurpose
This manual is ZXR10 2900E (V2.05.10) Series Easy-Maintenance Secure SwitchHardware Manual. It is applicable for ZXR10 2900E (V2.05.10) series easy-maintenancesecure switch (brieved as ZXR10 2900E series, also named as switch in common part).It includes:
l ZXR10 2910E-PS easy-maintenance secure switchl ZXR10 2918E-PS easy-maintenance secure switchl ZXR10 2918E easy-maintenance secure switchl ZXR10 2928E easy-maintenance secure switchl ZXR10 2952E easy-maintenance secure switch
What Is in This Manual
ZXR10 2900E (V2.05.10) series easy-maintenance secure switch hardware manualcontains the following chapters:
Chapter Summary
Chapter 1 Safety Instruction Describes the safety instructions and signs.
Chapter 2 System Overview Describes the overview of ZXR10 2900E.
Chapter 3 Hardware Descroption Describes ZXR10 2900E structure and principle
Chapter 4 Installation Describes ZXR10 2900E installation modes and methods.
I
II
Chapter 1Safety InstructionTable of ContentsSafety Instruction .......................................................................................................1-1Safety Signs...............................................................................................................1-1
1.1 Safety InstructionOnly duly trained and qualified personnel can install, operate and maintain the devices.
During the device installation, operation and maintenance, please abide the local safetyspecifications and related operation instructions, otherwise physical injury may occuror devices may be broken. The safety precautions mentioned in this manual are onlysupplement of local safety specifications.
The debug commands on the devices will affect the performance of the devices, whichmay bring serious consequences. So take care to use debug commands. Especially, thedebug all command will open all debug processes, so this command must not be used onthe devices with services. It is not recommended to use the debug commands when theuser networks are in normal state.
ZTE Corporation will assume no responsibility for consequences resulting from violationof general specifications for safety operations or of safety rules for design, production anduse of the devices.
1.2 Safety SignsThe contents that users should pay attention to when they install, operate and maintaindevices are explained in the following formats:
Warning!
Indicates the matters needing close attention. If this is ignored, serious injury accidentsmay happen or devices may be damaged.
Caution!
Indicates the matters needing attention during configuration.
1-1
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Note:
Indicates the description, hint, tip and so on for configuration operations.
1-2
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 2System OverviewTable of Contents
Product Introduction ...................................................................................................2-1Functions ...................................................................................................................2-2Technical Features and Parameters ...........................................................................2-3
2.1 Product IntroductionProduct Overview
The ZXR10 2918E-LE/2928E-LE/2952E-LE and the corresponding ZXR10 2918E/2928E/2952E have the same contents except names.
The ZXR10 2900E series switch is the easy-maintenance secure switch developed byZTE independently. The ZXR10 2900E series switch provides 100M access and supportsingress/egress ACL. It is used in education network access layer, enterprise networkaccess layer, political service network access layer and carrier building access layer.
Depending on switch capacity, the ZXR10 2900E series switch includes six products:l ZXR10 2918El ZXR10 2928El ZXR10 2952El ZXR10 2910E-PSl ZXR10 2918E-PSl ZXR10 2928E-PS
Product Features
The ZXR10 2900E series switch is environment friendly, safe, highly reliable, and easy tomaintain, which brings enjoyable experience to customers.
l Environment-friendly energy-saving design
Due to dynamic fan speed adjustment, intelligent power supply management, andreasonable PCB layout, the power of the series switch is reduced while the systemperformance is improved.
l Advanced lightning-protection technology
The series switch uses an advanced lightning-protection technology to minimize theprobability of damage in lightning weather. Thus the reliability is improved.
l Intelligent PoE supply
2-1
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
TheZXR10 2900E series switch supports the simple Power over Ethernet (PoE)supply mode IEEE 802.3af and IEEE 802.3at. Each PoE port supplies up to 30W.The series switch can supply power for devices that need high power, such as thenew generation IP visual telephone, dual-frequency WiFi AP, visual monitor camera,multi-function STB, and RFID card reader. As a result, network complexity is reduced.
The ZXR10 2900E series switch can control power by time segment. As a result, thepower consumption of network devices is effectively managed and operation costsare greatly reduced.
The ZXR10 2900E series switch also provides the functions of overload protection,short circuit protection, and real-time power detection to protect powered devices andpower sourcing equipment and maintain a sound circuit system.
l Powerful security platform
The ZXR10 2900E series switch supports two-way ACL to provide double securityguarantee. To control the access to a server, you need only enable egress ACL onthe port connected to the server.
Even if an illegal user breaks through the security system of a firewall, the user stillcannot attack the internal server.
l Abundant maintenance methods
Remote upgrades in batch mode: Lots of devices of the same type can be upgradedin batch mode. As a result, various network problems due to minor errors can beavoided.
Cluster management: On the master switch, you can view the statuses of otherswitches.
Power-down alarm: After a device is powered down, a power-down alarm isautomatically reported to the management center.
Multiple remote management methods: include Web, Telnet, and SNMP.
M-button: allows you to easily learn the operational statuses of switches.
2.2 FunctionsThe ZXR10 2900E series switch has the following functions:
l It supports the port duplex, speed, auto-negotiation, jumbo frame and line orderidentification configuration.
l It supports port–based VLAN.l It supports PVLAN, VLAN translation, QinQ and SQinQ.l It supports MAC line rate learning, port address number limit, port address fix and
manual MAC management.l It supports layer 2 line rate switching.l It supports ingress ACL, egress ACL and QoS.l It supports layer 2 multicast and IPTV.
2-2
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 2 System Overview
l It supports IEEE802.1X, IP SOURCE GUARD, CONSOLE port authentication anduser ranking.
l It supports LOOP DETECT and SSTP/RSTP/MSTP.l It supports ZESR, ZESS and link aggregation.l It supports OAM link detect mechanism.l It supports SFLOW network flow analysis function.l It supports cluster management, unified network management, TELNET and WEB.l It supports DHCP Snooping, DHCP Option82 and DHCP Client.l It supports NTP.l It supports Dot1X and Radius authentication.l It supports VBAS and PPPoE+.l It supports GARP/GVRP registry protocol.l It supports dynamic LACP protocol and static link aggregation.l It supports Syslog function.
2.3 Technical Features and ParametersThe ZXR10 2900E technical features and parameters are listed in Table 2-1.
Table 2-1 ZXR10 2900E Technical Features and Parameters
ItemZXR102918E
ZXR102928E
ZXR102952E
ZXR102910E-PS
ZXR102918E-PS
ZXR102928E-PS
Size
43.6 mm
(High)×442
mm
(Width)×220
mm (Depth)
43.6 mm
(High)×442
mm
(Width)×220
mm (Depth)
43.6 mm
(High)×442
mm
(Width)×280
mm (Depth)
43.6 mm
(High)×340
mm
(Width)×220
mm (Depth)
43.6 mm
(High)×442
mm
(Width)×220
mm (Depth)
43.6 mm
(High)×442
mm
(Width)×440
mm (Depth)
Weight <2.8 kg <3 kg <3.4 kg <3.0 kg <3.8 kg <6.4kg
Power
They support AC and DC inputs:
l AC Power Supply:
Rated voltage range: 100 V-240 V AC,
50 Hz/60 Hz
l DC Power Supply:
Rated voltage range: -48 V DC
It only
supports AC
input:Rated
voltage
range: 100
V-240 V AC,
50 Hz/60 Hz
It supports
AC and DC
RPS input:
l AC:
Rated
voltage
range:
100
V-240 V
AC, 50
Hz/60
Hz
l DC RPS
input:
Rated
voltage:
One or
two AC
input power
modules are
supported.
Rated
voltage
range: 100
V-240 V AC,
50 Hz/60 Hz
2-3
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
ItemZXR102918E
ZXR102928E
ZXR102952E
ZXR102910E-PS
ZXR102918E-PS
ZXR102928E-PS
-54 V
DC
Con-
sump-
tion
<13 W <17.1 W <27.2 W
<306 W,
PoE external
power is 240
W
<317 W,
PoE external
power is
246.4 W
<831W, PoE
external
power is 720
W
Envi-
ron-
ment
Tem-
pera-
ture
Work environment temperature
l For long-term work: -5 ℃ to +50 ℃l For short-term work: -5 ℃ to +55 ℃Storage environment temperature: -40 ℃ to +70 ℃
Work-
ing Hu-
midity
Relative Humidity 10%-90%, non-condensation
Mem-
ory
Size
128 MB
Ex-
change
Capac-
ity of
Ports
7.2 Gbps 12.8 Gbps 17.6 Gbps 5.6 Gbps 7.2 Gbps 12.8Gbps
Packet
For-
ward-
ing
Rate
5.4 Mpps 9.6 Mpps 13.2Mpps 4.2 Mpps 5.4 Mpps 9.6Mpps
Capac-
ity of
MAC
Ad-
dress
Table
16K
2-4
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3Hardware DescroptionTable of Contents
Hardware Structure ....................................................................................................3-1Cables......................................................................................................................3-39
3.1 Hardware StructureThe ZXR10 2900E adopts the box structure and is 1U (1U=44.45 mm) high. The hardwareincludes the box, power supply device, the Ethernet switching main board, and fans.
Box Body
The box is mainly composed of chassis and shell with light weight and simple structure,which is convenient for installation and disassembly.
On the front panel of ZXR10 2918E/2928E/2910E-PS/2918E-PS, there are AC or DCpower supply interface, power supply switch, service interfaces, interface status indicator,serial configuration port and system status indicators. On the back panel of ZXR102918E-PS, there are RPS power interface.
On the front panel of ZXR10 2952E, there are service interfaces, interface status indicator,serial configuration port and system status indicators. On the back panel , there are AC orDC power supply interface and power supply switch.
ZXR10 2928E-PS provides service ports, uplink interface slots, port status indicators,management network ports, serial configuration interfaces, mode button and systemstatus indicators on the front panel. In addition, ZXR10 2928E-PS provides 1 fan moduleslot and 2 slots for modularized power supplies which have switches on the rear panel.Both the modularized power supplies and fan modules support hot swap.
Power Supply
The power supply is separately provided. It supports -48V DC or 110V/220V AC. Inaddition, ZXR10 2918E-PS supports RPS power input.
ZXR10 2928E-PS supports two input power modules. You can configure single-module ordual-module power supply as required. The switch supports 110V/220V AC power supply,and power modules are hot-swappable.
For the power module of the ZXR10 2900E, pay attention to the following points:
l The structure and interfaces of the power module on the shelf vary with the powerinput mode.
3-1
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
l During operations and maintenance, avoid performing any operation on the powermodule when the power module is supplied with power.
l For the AC power mode, the system only supports single-phase.
Ethernet Switching Main Board
Ethernet switching main board is the core hardware of ZXR102910E-PS/2918E-PS/2928E-PS/2918E/2928E/2952E, which implements the switchingand forwarding function of switch.
Heat Dissipation System
The ZXR10 2918E/2928E/2952E uses natural cooling mode with vent hole configured onback and two sides of these devices.
The ZXR10 2910E-PS and ZXR10 2918E-PS uses air extraction for heat dissipation.The system supports the functions of automatically adjusting the fan speed based on theoperating and environmental conditions, fan status monitoring, and fault alarming. Forthe technical parameters of fans, refer to Table 3-1.
Table 3-1 Technical Parameters of ZXR10 2910E-PS/2918E-PS Fans
Parameter Description
Size 40 mm × 40 mm × 20 mm (width × height × depth)
Aperture 3.3mm~3.7 mm
Wire length 490mm~510 mm
Rated voltage 12 V
Operational voltage range 7V~15 V
Power 0.5 A (max)
The ZXR10 2928E-PS uses active air cooling for heat dissipation. A heat dissipation fanmodule is installed on the rear panel of the switch, and two speed-adjustable fans canbe installed. The fan module is hot-swappable and speed-adjustable. For the technicalparameters of fans, refer to Table 3-2.
Table 3-2 Technical Parameters of ZXR10 2928E-PSS Fans
Parameter Description
Size 40 mm × 40 mm × 20 mm (width × height × depth)
Aperture 3.2mm~3.8 mm
Wire length 140mm~160 mm
Rated voltage 12 V
Operational voltage range 7V~15 V
Power 0.5A (max)
3-2
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
3.1.1 ZXR10 2918E
Device Appearance
ZXR10 2918E is 1U (1U=44.45 mm) high. It provides AC and DC power supplies.
For the front panel of ZXR10 2918E AC model, see Figure 3-1.
Figure 3-1 ZXR10 2918E AC Model Front Panel
For the front panel of ZXR10 2918E DC model, see Figure 3-2.
Figure 3-2 ZXR10 2918E DC Model Front Panel
Power Supply
ZXR10 2918E supports two power supply modes: -48 V DC power supply and 110 V/220V AC power supply. When the -48 V DC power supply is used, use –48 V DC power cable.When the AC power supply is used, use AC power cables.
3-3
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Interfaces
For ZXR10 2918E interface descriptions, refer to Table 3-3.
Table 3-3 ZXR10 2918E Interface Descriptions
Name Quantity Description
10/100Base-TX Ethernet port 16 These Ethernet ports are fixed.
Combo port 2
You can configure either 10/100/1000Base-T
Ethernet ports or SFP ports (100Base-FX/1000Base-
FX) as combo ports. 10/100/1000Base-T and
100Base-FX/1000Base-FX cannot be used
simultaneously.
CONSOLE port 1 The CONSOLE port implements service
configuration and management.
Indicators
The following indicators are used on the ZXR10 2918E.
l 16 indicators indicate the statuses of the 16 10/100Base-TX ports. Each interfacecorresponds to one indicator.
l Four indicators indicate the statuses of two Combo interfaces (the RJ45 port andSFP port with the same port number are Combo ports for each other). Each10/100/1000Base-T Ethernet interface has two indicators. The left indicator indicatesthe status of the interface below. The right indicator indicates the status of interfaceabove. Each SFP port has one indicator indicating port status.
l Three system indicators.
Indicators running statuses are described as follows:
1. System indicator
System indicators include power indicator (PWR), running indicator (SYS) and alarmindicator (ALM).
l After the system is powered up, the PWR indicator is on and the SYS indicator ison.
l When Boot starts to load the version, if the version is unavailable, the states ofindicators do not change. If the version is loaded normally, the SYS indicatorflashes at a frequency of one time per second.
The ZXR10 2918E system indicators are listed as Table 3-4.
3-4
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Table 3-4 ZXR10 2918E System Indicators
Indicator Position State Meaning
Off Power off
green The device is starting.SYS
On the right side
of CONSOLE
port Green indicator
is flashingThe device is running.
Off The device runs normally.
ALM
On the right side
of CONSOLE
port green The device runs abnormally.
Off Power off
PWR
On the right side
of CONSOLE
port On Power on
2. Port indicator
There is a M_button on the front panel. The mode is selected according to modebutton. The corresponding port state indicator will turn on, which makes it convenientto maintain our equipments.
ZXR10 2918E port indicator descriptions are listed as Table 3-5.
Table 3-5 ZXR10 2918E Port Indicator Description
Indicator PositionM_buttonFunctionOption
State Meaning
Off No connection
Green
indicator is
on
The connection is established.
None
Green
indicator is
flashing
Data is transferred.
Off No Link
Green
indicator is
on
Link
LINK
Green
indicator is
flashing
Data is transferred.
Green
indicator is
on
Port speed is 100M.SPD
10/100B-
ase-TX port
On top of
the port
3-5
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Indicator PositionM_buttonFunctionOption
State Meaning
Yellow
indicator is
on
Port speed is 10M.
Green
indicator is
on
Port is in full-duplex state.
DUPYellow
indicator is
on
Port is in half-duplex state.
Off The STP state of port is disable.
Green
indicator is
on
The STP state of port is forward.
STAT
Yellow
indicator is
on
Other
CPU%
Green
indicator is
on
Uses the indicator of port 1~10 to show
the current CPU utilization ratio, each
port indicates 10%.
MEM%
Green
indicator is
on
Uses the indicator of port 1~10 to show
the current memory utilization ratio,
each port indicates 10%.
↑BW%
Green
indicator is
on
Uses the indicator of port 1~10 to
display current uplink port outbound
bandwidth occupation rate, take the
uplink port current speed as baseline.
↓BW%
Green
indicator is
on
Uses the indicator of port 1~10 to
display current uplink port inbound
bandwidth occupation rate, take the
uplink port current speed as baseline.
Green
indicator is
on
Equipment will send 5 ICMP packets to
network management center, for each
ICMP packet, use 1-5 port indicators
to indicate the right reply is received.
PING
3-6
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Indicator PositionM_buttonFunctionOption
State Meaning
Yellow
indicator is
on
Equipment will send 5 ICMP packets to
network management center, for each
ICMP packet, use 1-5 port indicators to
indicate the right reply is not received.
CRC
Green
indicator is
on
Port has CRC error frame statistics.
STORM
Green
indicator is
on
Port is storm port.
NoMAC
Green
indicator is
on
Port does not learn MAC.
Off No connection
Green
indicator is
on
The connection is established.
None
Green
indicator is
flashing
Data is transferred.
Off No Link
Green
indicator is
on
Link
LINK
Green
indicator is
flashing
Data is transferred.
Green
indicator is
on
Port speed is 1000M.
SPDYellow
indicator is
on
Port speed is 10M/100M.
Green
indicator is
on
Port is in full-duplex state.
Combo
port(10/10
0/1000B-
ase-T or
100Base-
FX/1000B-
ase-FX)
below the
port
DUP
3-7
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Indicator PositionM_buttonFunctionOption
State Meaning
Yellow
indicator is
on
Port is in half-duplex state.
3.1.2 ZXR10 2928E
Device Appearance
ZXR10 2928E is 1U (1U=44.45 mm) high. It provides AC and DC power supplies.
The front panel of ZXR10 2928E AC model is shown in Figure 3-3.
Figure 3-3 ZXR10 2928E AC Model Front Panel
The front panel of ZXR10 2928E DC model is shown in Figure 3-4.
Figure 3-4 ZXR10 2928E DC Model Front Panel
3-8
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Power SupplyZXR10 2928E supports two power supply modes: -48 V DC power supply and 110 V/220V AC power supply. When the -48 V DC power supply is used, use –48 V DC power cable.When the AC power supply is used, use AC power cables.
InterfacesFor ZXR10 2928E interface descriptions, refer to Table 3-6.
Table 3-6 ZXR10 2928E Interface Descriptions
Name Quantity Description
10/100Base-TX Ethernet port 24 These Ethernet ports are fixed.
Combo port 2
You can configure either 10/100/1000Base-T
Ethernet ports or SFP ports (100Base-FX/1000Base-
FX) as combo ports. 10/100/1000Base-T and
100Base-FX/1000Base-FX cannot be used
simultaneously.
SFP port 2 You can configure 1000Base-FX as SFP ports.
CONSOLE port 1 The CONSOLE port implements service
configuration and management.
IndicatorsThe following indicators are used on the ZXR10 2928E.
l 24 indicators indicate the status of the 24 10/100Base-TX ports. Each interfacecorresponds one indicator.
l Four indicators show the status of two Combo ports (the RJ45 port and SFP port withthe same port number are Combo ports for each other). Each 10/100/1000Base-TEthernet port has two indicators. The left indicator of port shows the status of the portbelow. The right indicator of port shows the status of port above. Each SFP port hasone indicator indicating port status.
l Two port indicators show the two fixed SFP port status. Each interface has oneindicator below it.
l Three system indicators.
Indicators running statuses are described as follows:
1. System indicator
System indicators include power indicator (PWR), running indicator (SYS) and alarmindicator (ALM).
l After the system is powered up, the PWR indicator is on and the SYS indicator ison.
l When Boot starts to load the version, if the version is unavailable, the states ofindicators do not change. If the version is loaded normally, the SYS indicatorflashes at a frequency of one time per second.
3-9
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
The ZXR10 2928E system indicators are listed as Table 3-7.
Table 3-7 ZXR10 2928E System Indicators
Indicator Position State Meaning
Off Power off
green The device is starting.SYS
On the right side
of CONSOLE
port Green indicator
is flashingThe device is running.
Off The device runs normally.
ALM
On the right side
of CONSOLE
port green The device runs abnormally.
Off Power off
PWR
On the right side
of CONSOLE
port On Power on
2. Port indicator
There is a M_button on the front panel. The mode is selected according to modebutton. The corresponding port state indicator will turn on, which makes it convenientto maintain our equipments.
ZXR10 2928E port indicator descriptions are listed as Table 3-8.
Table 3-8 ZXR10 2928E Port Indicator Description
Indicator PositionM_buttonFunctionOption
State Meaning
Off No connection
Green
indicator is
on
The connection is established.
None
Green
indicator is
flashing
Data is transferred.
Off No link
Green
indicator is
on
link
LINK
Green
indicator is
flashing
Data is transferred.
10/100B-
ase-TX port
On top of
the port
3-10
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Indicator PositionM_buttonFunctionOption
State Meaning
Green
indicator is
on
Port speed is 100M.
SPDYellow
indicator is
on
Port speed is 10M.
Green
indicator is
on
Port is in full-duplex state.
DUPYellow
indicator is
on
Port is in half-duplex state.
Off The STP state of port is disable.
Green
indicator is
on
The STP state of port is forward.
STAT
Yellow
indicator is
on
Other
CPU%
Green
indicator is
on
Uses the indicator of port 1-10 to show
the current CPU utilization ratio, each
port indicates 10%.
MEM%
Green
indicator is
on
Uses the indicator of port 1-10 to show
the current memory utilization ratio,
each port indicates 10%.
↑BW%
Green
indicator is
on
Uses the indicator of port 1-10 to
display current uplink port outbound
bandwidth occupation rate, take the
uplink port current speed as baseline.
↓BW%
Green
indicator is
on
Uses the indicator of port 1-10 to
display current uplink port inbound
bandwidth occupation rate, take the
uplink port current speed as baseline.
Green
indicator is
on
Equipment will send 5 ICMP packets to
network management center, for each
ICMP packet, use 1-5 port indicators
to indicate the right reply is received.
PING
3-11
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Indicator PositionM_buttonFunctionOption
State Meaning
Yellow
indicator is
on
Equipment will send 5 ICMP packets to
network management center, for each
ICMP packet, use 1-5 port indicators to
indicate the right reply is not received.
CRC
Green
indicator is
on
Port has CRC error frame statistics.
STORM
Green
indicator is
on
Port is storm port.
NoMAC
Green
indicator is
on
Port does not learn MAC.
Off No connection
Green
indicator is
on
The connection is established.
None
Green
indicator is
flashing
Data is transferred.
Off No Link
Green
indicator is
on
Link
LINK
Green
indicator is
flashing
Data is transferred.
Green
indicator is
on
Port speed is 1000M.
SPDYellow
indicator is
on
Port speed is 10M/100M.
Green
indicator is
on
Port is in full-duplex state.
Combo
port(10/10
0/1000B-
ase-T or
100Base-
FX/1000B-
ase-FX)
below the
port
DUP
3-12
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Indicator PositionM_buttonFunctionOption
State Meaning
Yellow
indicator is
on
Port is in half-duplex state.
Off No connection
Green
indicator is
on
The connection is established.Fixed SFP
port(100B-
ase-FX/100
0Base-FX)
below the
portNone
Green
indicator is
flashing
Data is transferred.
3.1.3 ZXR10 2952E
Device Appearance
ZXR10 2952E is 1U (1U=44.45 mm) high. It provides AC and DC power supplies.
The front panel of ZXR10 2952E is shown in Figure 3-5.
Figure 3-5 ZXR10 2952E Front Panel
Power Supply
ZXR10 2952E supports two power supply modes: -48 V DC power supply and 110 V/220V AC power supply. When the -48 V DC power supply is used, use –48 V DC power cable.When the AC power supply is used, use AC power cables.
The power socket and switch of ZXR10 2952E are on the back panel. For the AC modelback panel, see Figure 3-6. For the DC model back panel, see Figure 3-7.
3-13
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Figure 3-6 ZXR10 2952E Back Panel (AC power)
Figure 3-7 ZXR10 2952E Back Panel (DC power)
InterfacesFor ZXR10 2952E interface descriptions, refer to Table 3-9.
Table 3-9 ZXR10 2952E Interface Descriptions
Name Quantity Description
10/100Base-TX Ethernet port 48 These Ethernet ports are fixed.
SFP port 4 You can configure 1000Base-FX as SFP ports.
CONSOLE port 1 The CONSOLE port implements service
configuration and management.
ZXR10 2952E provides the following types of access ports.
l 48 fixed 10/100Base-TX Ethernet ports.l 4 fixed SFP ports, which can be configured as 1000Base-FX.l One console port is to realize the management and configuration of various services.
IndicatorsThe following indicators are used on the ZXR10 2952E:
l 48 indicators indicate the status of the 48 10/100Base-TX ports. Each interfacecorresponds one indicator.
3-14
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
l Four port indicators show the four fixed SFP port status. Each interface has oneindicator below it.
l Three system indicators.
Indicators running statuses are described as follows:
1. System indicator
System indicators include power indicator (PWR), running indicator (SYS) and alarmindicator (ALM).
l After the system is powered up, the PWR indicator is on and the SYS indicator ison.
l When Boot starts to load the version, if the version is unavailable, the states ofindicators do not change. If the version is loaded normally, the SYS indicatorflashes at a frequency of one time per second.
ZXR10 2952E system indicators are listed as Table 3-10.
Table 3-10 ZXR10 2952E System Indicators
Indicator Position State Meaning
Off Power off
green The device is starting.SYS
On the lower
right side of
CONSOLE port Green indicator
is flashingThe device is running.
Off The device runs normally.
ALM
On the lower
right side of
CONSOLE port green The device runs abnormally.
Off Power off
PWR
On the lower
right side of
CONSOLE port On Power on
2. Port indicator
There is a M_button on the front panel. The mode is selected according to modebutton. The corresponding port state indicator will turn on, which makes it convenientto maintain our equipments.
ZXR10 2952E port indicator descriptions are listed as Table 3-11.
3-15
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Table 3-11 ZXR10 2952E Port Indicator Description
Indicator PositionM_buttonFunctionOption
State Meaning
Off No connection
Green
indicator is
on
The connection is established.
None
Green
indicator is
flashing
Data is transferred.
Off No Link
Green
indicator is
on
Link
LINK
Green
indicator is
flashing
Data is transferred.
Green
indicator is
on
Port speed is 100M.
SPDYellow
indicator is
on
Port speed is 10M.
Green
indicator is
on
Port is in full-duplex state.
DUPYellow
indicator is
on
Port is in half-duplex state.
Off The STP state of port is disable.
Green
indicator is
on
The STP state of port is forward.
STAT
Yellow
indicator is
on
Other
10/100B-
ase-TX port
On top of
the port
3-16
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Indicator PositionM_buttonFunctionOption
State Meaning
CPU%
Green
indicator is
on
Uses the indicator of port 1-10 to show
the current CPU utilization ratio, each
port indicates 10%.
MEM%
Green
indicator is
on
Uses the indicator of port 1-10 to show
the current memory utilization ratio,
each port indicates 10%.
↑BW%
Green
indicator is
on
Uses the indicator of port 1-10 to
display current uplink port outbound
bandwidth occupation rate, take the
uplink port current speed as baseline.
↓BW%
Green
indicator is
on
Uses the indicator of port 1-10 to
display current uplink port inbound
bandwidth occupation rate, take the
uplink port current speed as baseline.
Green
indicator is
on
Equipment will send 5 ICMP packets to
network management center, for each
ICMP packet, use 1-5 port indicators
to indicate the right reply is received.PING
Yellow
indicator is
on
Equipment will send 5 ICMP packets to
network management center, for each
ICMP packet, use 1-5 port indicators to
indicate the right reply is not received.
CRC
Green
indicator is
on
Port has CRC error frame statistics.
STORM
Green
indicator is
on
Port is storm port.
NoMAC
Green
indicator is
on
Port does not learn MAC.
Off No connection
Green
indicator is
on
The connection is established.Fixed SFP
port(100B-
ase-FX/100
0Base-FX)
below the
portNone
Green
indicator is
flashing
Data is transferred.
3-17
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
3.1.4 ZXR10 2910E-PS
Device Appearance
ZXR10 2910E-PS is 1U (1U=44.45 mm) high.
The front panel of 2910E-PS is shown in Figure 3-8.
Figure 3-8 ZXR10 2910E-PS Front Panel
Power Supply
ZXR10 2910E-PS supports AC power supply. The AC power socket and switch are on thefront panel.
Interfaces
For ZXR10 2910E-PS interface descriptions, refer to Table 3-12.
Table 3-12 ZXR10 2910E-PS Interface Descriptions
Name Quantity Description
10/100Base-TX Ethernet port 8
These Ethernet ports are fixed. PoE is supported,
and 45/78 line pairs are used to supply power, see
Figure 3-9.
Combo port 2 You can configure either 10/100/1000Base-T
Ethernet ports or SFP ports (100Base-FX/1000Base-
FX) as combo ports. 10/100/1000Base-T and
100Base-FX/1000Base-FX cannot be used
simultaneously.
CONSOLE port 1 The CONSOLE port implements service
configuration and management.
3-18
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Figure 3-9 ZXR10 2910E-PS 45/78 line pair for power supply
Indicators
The following indicators are used on the ZXR10 2910E-PS.
l 8 indicators indicate the status of the 8 10/100Base-TX ports. Each interfacecorresponds one indicator.
l Four indicators show the status of two Combo ports (the RJ45 port and SFP port withthe same port number are Combo ports for each other). Each 10/100/1000Base-TEthernet port has two indicators. The left indicator of port shows the status of the portbelow. The right indicator of port shows the status of port above. Each SFP port hasone indicator indicating port status.
l Three system indicators.
Indicators running statuses are described as follows:
1. System indicator
System indicators include power indicator (PWR), running indicator (SYS) and alarmindicator (ALM).
l After the system is powered up, the PWR indicator is on and the SYS indicator ison.
l When Boot starts to load the version, if the version is unavailable, the states ofindicators do not change. If the version is loaded normally, the SYS indicatorflashes at a frequency of one time per second.
ZXR10 2910E-PS system indicators are listed as Table 3-13.
3-19
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Table 3-13 ZXR10 2910E-PS System Indicators
Indicator Position State Meaning
Off Power off
green The device is starting.SYS
On the right side
of CONSOLE
port Green indicator
is flashingThe device is running.
Off The device runs normally.
ALM
On the right side
of CONSOLE
port green The device runs abnormally.
Off Power off
PWR
On the right side
of CONSOLE
port On Power on
2. Port indicator
There is a M_button on the front panel. The mode is selected according to modebutton. The corresponding port state indicator will turn on, which makes it convenientto maintain our equipments.
ZXR10 2910E-PS port indicator descriptions are listed as Table 3-14.
Table 3-14 ZXR10 2910E-PS Port Indicator Description
Indicator PositionM_buttonFunctionOption
State Meaning
Off No connection
Green
indicator is
on
The connection is established.
None
Green
indicator is
flashing
Data is transferred.
Off No Link
Green
indicator is
on
Link
LINK
Green
indicator is
flashing
Data is transferred.
Green
indicator is
on
Port speed is 100M.SPD
10/100B-
ase-TX port
On top of
the port
3-20
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Indicator PositionM_buttonFunctionOption
State Meaning
Yellow
indicator is
on
Port speed is 10M.
Green
indicator is
on
Port is in full-duplex state.
DUPYellow
indicator is
on
Port is in half-duplex state.
Off The STP state of port is disable.
Green
indicator is
on
The STP state of port is forward.
STAT
Yellow
indicator is
on
Other
Off Port is power off.
Green
indicator is
on
Port is power on.
PoE
Yellow
indicator is
on
Port power supply is abnormal.
CPU%
Green
indicator is
on
Uses the indicator of port 1-8 to show
the current CPU utilization ratio, each
port indicates 12.5%
MEM%
Green
indicator is
on
Uses the indicator of port 1-8 to show
the current memory utilization ratio,
each port indicates 12.5%
STORM
Green
indicator is
on
Port is storm port.
3-21
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Indicator PositionM_buttonFunctionOption
State Meaning
Off No connection
Green
indicator is
on
The connection is established.
None
Green
indicator is
flashing
Data is transferred.
Off No Link
Green
indicator is
on
Link
LINK
Green
indicator is
flashing
Data is transferred.
Green
indicator is
on
Port speed is 1000M.
SPDYellow
indicator is
on
Port speed is 10M/100M.
Green
indicator is
on
Port is in full-duplex state.
Combo
port(10/10
0/1000B-
ase-T or
100Base-
FX/1000B-
ase-FX)
below the
port
DUPYellow
indicator is
on
Port is in half-duplex state.
3. Power indicator
Power has two indicators including PoE PWR and FAULT.
ZXR10 2910E-PS power indicator descriptions are listed as Table 3-15.
Table 3-15 ZXR10 2910E-PS Power Indicator Descriptions
Indicator Position State Meaning
Off Power off
PoE PWROn the left of AC
power socket Green indicator
is onPower works normally.
3-22
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Indicator Position State Meaning
Off Power off or power has no faults.
FAULTOn the left of AC
power socket Red indicator is
on
Power has temperature alarm or has
faults.
3.1.5 ZXR10 2918E-PS
Device Appearance
ZXR10 2918E-PS is 1U (1U=44.45 mm) high.
The front panel of 2918E-PS is shown in Figure 3-10.
Figure 3-10 ZXR10 2918E-PS Front Panel
Power Supply
ZXR10 2918E-PS supports AC power supply and RPS power supply. When 110 V/220V AC power supply is applied, use AC power cable. When RPS power supply is applied,RPS power developed by ZTE (RPS550 or RPS1100) and the private RPS power cablemust be used and AC power should be off.
The AC power socket and switch are on the front panel. The front panel of 2918E-PS isshown in Figure 3-10.
RPS power panel is shown as Figure 3-11.
Figure 3-11 ZXR10 2918E-PS Back Panel
The RPS power supply detailed information is as follows:
l The RPS550 front panel is shown in Figure 3-12. Two three-core interfaces on the leftare the RPS power supply output interfaces. Any of them can be used when ZXR102900E interconnects to the ZXR10 2918E-PS. Refer to the ”Power Cable” chapter forcable connections.
The technical parameter of RPS550 power supply. The device can operate properlyunder the following environment:
3-23
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Parameter Value
Input voltage 100 V to 240 V AC
Output maximum voltage -54 V
Output electrical current 10.2 A
Output maximum power 550 W
Figure 3-12 Front Panel of RPS550
l TheRPS1100 front panel is shown in Figure 3-13. Two three-core interfaces on the leftare the RPS power supply output interfaces. Any of them can be used when ZXR102900E interconnects to the ZXR10 2918E-PS. Refer to the ”Power Cable” chapter forcable connections.
The technical parameter of RPS1100 power supply. The device can operate properlyunder the following environment:
Parameter Value
Input voltage 100 V to 240 V AC
Output maximum voltage -54 V
Output electrical current 20.4 A
Output maximum power 1100 W
Figure 3-13 Front Panel of RPS1100
3-24
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Interfaces
For ZXR10 2918E-PS interface descriptions, refer to Table 3-16.
Table 3-16 ZXR10 2918E-PS Interface Descriptions
Name Quantity Description
10/100Base-TX Ethernet port 16
These Ethernet ports are fixed. PoE is supported,
and 45/78 line pairs are used to supply power, see
Figure 3-14.
Combo port 2 You can configure either 10/100/1000Base-T
Ethernet ports or SFP ports (100Base-FX/1000Base-
FX) as combo ports. 10/100/1000Base-T and
100Base-FX/1000Base-FX cannot be used
simultaneously.
CONSOLE port 1 The CONSOLE port implements service
configuration and management.
Figure 3-14 ZXR10 2918E-PS 45/78 line pair for power supply
Indicators
The following indicators are used on the ZXR10 2918E-PS.
l 16 indicators indicate the status of the 16 10/100Base-TX ports. Each interfacecorresponds one indicator.
l Four indicators show the status of two Combo ports (the RJ45 port and SFP port withthe same port number are Combo ports for each other). Each 10/100/1000Base-TEthernet port has two indicators. The left indicator of port shows the status of the portbelow. The right indicator of port shows the status of port above. Each SFP port hasone indicator indicating port status.
l Three system indicators.
Indicators running statuses are described as follows:
3-25
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
1. System indicator
System indicators include power indicator (PWR), running indicator (SYS) and alarmindicator (ALM).
l After the system is powered up, the PWR indicator is on and the SYS indicator ison.
l When Boot starts to load the version, if the version is unavailable, the states ofindicators do not change. If the version is loaded normally, the SYS indicatorflashes at a frequency of one time per second.
ZXR10 2918E-PS system indicators are listed as Table 3-17.
Table 3-17 ZXR10 2918E-PS System Indicators
Indicator Position State Meaning
Off Power off
green The device is starting.SYS
On the right side
of CONSOLE
port Green indicator
is flashingThe device is running.
Off The device runs normally.
ALM
On the right side
of CONSOLE
port green The device runs abnormally.
Off Power off
PWR
On the right side
of CONSOLE
port On Power on
Off Without RPS power supply
RPS
On the right side
of CONSOLE
port green RPS power supply
2. Port indicator
There is a M_button on the front panel. The mode is selected according to modebutton. The corresponding port state indicator will turn on, which makes it convenientto maintain our equipments.
ZXR10 2918E-PS port indicator descriptions are listed as Table 3-18.
Table 3-18 2918E-PS Port Indicator Description
Indicator PositionM_buttonFunctionOption
State Meaning
Off No connection
Green
indicator is
on
The connection is established.None
10/100B-
ase-TX port
On top of
the port
3-26
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Indicator PositionM_buttonFunctionOption
State Meaning
Green
indicator is
flashing
Data is transferred.
Off No Link
Green
indicator is
on
Link
LINK
Green
indicator is
flashing
Data is transferred.
Green
indicator is
on
Port speed is 100M.
SPDYellow
indicator is
on
Port speed is 10M.
Green
indicator is
on
Port is in full-duplex state.
DUPYellow
indicator is
on
Port is in half-duplex state.
Off The STP state of port is disable.
Green
indicator is
on
The STP state of port is forward.
STAT
Yellow
indicator is
on
Other
Off Port is power off.
Green
indicator is
on
Port is power on.
PoE
Yellow
indicator is
on
Port power supply is abnormal.
3-27
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Indicator PositionM_buttonFunctionOption
State Meaning
CPU%
Green
indicator is
on
Uses the indicator of port 1~10 to show
the current CPU utilization ratio, each
port indicates 10%
MEM%
Green
indicator is
on
Uses the indicator of port 1~10 to show
the current memory utilization ratio,
each port indicates 10%
↑BW%
Green
indicator is
on
Uses the indicator of port 1~10 to
display current uplink port outbound
bandwidth occupation rate, take the
uplink port current speed as baseline.
↓BW%
Green
indicator is
on
Uses the indicator of port 1~10 to
display current uplink port inbound
bandwidth occupation rate, take the
uplink port current speed as baseline.
Green
indicator is
on
Equipment will send 5 ICMP packets to
network management center, for each
ICMP packet, use 1-5 port indicators
to indicate the right reply is received.PING
Yellow
indicator is
on
Equipment will send 5 ICMP packets to
network management center, for each
ICMP packet, use 1-5 port indicators to
indicate the right reply is not received.
CRC
Green
indicator is
on
Port has CRC error frame statistics.
STORM
Green
indicator is
on
Port is storm port.
NoMAC
Green
indicator is
on
Port does not learn MAC.
3-28
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Indicator PositionM_buttonFunctionOption
State Meaning
Off No connection
Green
indicator is
on
The connection is established.
None
Green
indicator is
flashing
Data is transferred.
Off No Link
Green
indicator is
on
Link
LINK
Green
indicator is
flashing
Data is transferred.
Green
indicator is
on
Port speed is 1000M.
SPDYellow
indicator is
on
Port speed is 10M/100M.
Green
indicator is
on
Port is in full-duplex state.
Combo
port(10/10
0/1000B-
ase-T or
100Base-
FX/1000B-
ase-FX)
below the
port
DUPYellow
indicator is
on
Port is in half-duplex state.
3. Power indicator
Power has two indicators including PoE PWR and FAULT.
ZXR10 2918E-PS power indicator descriptions are listed as Table 3-19.
Table 3-19 ZXR10 2918E-PS Power Indicator Descriptions
Indicator Position State Meaning
Off Power off
PoE PWROn the left of AC
power socket Green indicator
is onPower works normally.
3-29
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Indicator Position State Meaning
Off Power off or power has no faults.
FAULTOn the left of AC
power socket Red indicator is
on
Power has temperature alarm or has
faults.
3.1.6 ZXR10 2928E-PS
Device Appearance
ZXR10 2928E-PS is 1U (1U=44.45 mm) high.
For the front panel of 2928E-PS, see Figure 3-15.
Figure 3-15 ZXR10 2928E-PS Front Panel
1. RS-29EC-4GE-SFPdaughter card
2. RS-29EC-4GE-RJ45daughter card
3. RS-29EC-4FE-SFPdaughter card
Power Supply
ZXR10 2928E-PS utilizes a modularized power supply and it supports one or two ACmodularized power supplies (used simultaneously) which are available for hot swap. If110V/220V AC power is used, use AC power cables.
The sockets and switch for the AC power supplies are located on the rear panel of thedevice, see Figure 3-16.
Figure 3-16 Rear Panel of the AC Modularized Power Supply in ZXR10 2928E-PS
Interfaces
For ZXR10 2928E-PS interface descriptions, refer to Table 3-20.
3-30
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Table 3-20 ZXR10 2928E-PS Interface Descriptions
Name Quantity Description
10/100Base-TX Ethernet port 24
PoE is supported, which the IEEE 802.3af and IEEE
802.3at standards. 45/78 line pairs are used to
supply power, see Figure 3-17.
Uplink subcard slot 1 Supported uplink subcards include the 4–port GE
optical subcard RS-29EC-4GE-SFP, the 4–port GE
electrical subcard RS-29EC-4GE-RJ45, and the
4–port FE optical subcard RS-29EC-4FE-SFP.
CONSOLE port 2 One RJ45 interface and one Mini USB interface are
configured, which cannot be used simultaneously.
The CONSOLE ports implement service
configuration and management.
Management port 1 The management port implements the boot and
version downloading operations.
Figure 3-17 ZXR10 2928E-PS 45/78 Line Pair for Power Supply
IndicatorsThe following indicators are used on the ZXR10 2928E-PS.
l 24 port indicators indicate the statuses of 24 10/100Base-TX interfaces, each portcorresponding to an indicator.
l The uplink interface self-contains 4 interface indicators indicating the statuses of thefour interfaces, each interface corresponding to an indicator.
l 1 debugging network interface indicator, indicating the status of the debugging networkinterface.
l 3 system indicators.
Indicators running statuses are described as follows:
1. System indicator
3-31
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
System indicators include power indicator (PWR), running indicator (SYS) and alarmindicator (ALM).
l After the system is powered up, the PWR indicator is on and the SYS indicator ison.
l When Boot starts to load the version, if the version is unavailable, the states ofindicators do not change. If the version is loaded normally, the SYS indicatorflashes at a frequency of one time per second.
l ZXR10 2918E-PS system indicators are listed as Table 3-21.
Table 3-21 ZXR10 2928E-PS System Indicators
Indicator Position Status Description
Off Power off
green The device is starting.SYS
Below the
CONSOLE
interface of the
Mini USB formGreen indicator
is flashingThe device is running.
Off The device runs normally.
ALM
Below the
CONSOLE
interface of the
Mini USB formgreen The device runs abnormally.
Off Power off
PWR
Below the
CONSOLE
interface of the
Mini USB formOn Power on
2. Port indicator
There is a M_button on the front panel. The mode is selected according to modebutton. The corresponding port state indicator will turn on, which makes it convenientto maintain our equipments.
ZXR10 2928E-PS port indicator descriptions are listed as Table 3-22.
Table 3-22 2928E-PS Port Indicator Description
Indicator PositionM_buttonFunctionOption
Status Description
Off No connection
Green
indicator is
on
The connection is established.
None
Green
indicator is
flashing
Data is transferred.
10/100B-
ase-TX in-
terface indi-
cator
On top of
the port
3-32
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Indicator PositionM_buttonFunctionOption
Status Description
Off No Link
Green
indicator is
on
Link
LINK
Green
indicator is
flashing
Data is transferred.
Green
indicator is
on
Port speed is 100M.
SPDYellow
indicator is
on
Port speed is 10M.
Green
indicator is
on
Port is in full-duplex state.
DUPYellow
indicator is
on
Port is in half-duplex state.
Off The STP state of port is disable.
Green
indicator is
on
The STP state of port is forward.
STAT
Yellow
indicator is
on
Other
Off Port is power off.
Green
indicator is
on
Port is power on.
POE
Yellow
indicator is
on
Port power supply is abnormal.
CPU%
Green
indicator is
on
Uses the indicator of port 1-10 to show
the current CPU utilization ratio, each
port indicates 10%
3-33
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Indicator PositionM_buttonFunctionOption
Status Description
MEM%
Green
indicator is
on
Uses the indicator of port 1-10 to show
the current memory utilization ratio,
each port indicates 10%
↑BW%
Green
indicator is
on
Uses the indicator of port 1-10 to
display current uplink port outbound
bandwidth occupation rate, take the
uplink port current speed as baseline.
↓BW%
Green
indicator is
on
Uses the indicator of port 1-10 to
display current uplink port inbound
bandwidth occupation rate, take the
uplink port current speed as baseline.
Green
indicator is
on
Equipment will send 5 ICMP packets to
network management center, for each
ICMP packet, use 1-5 port indicators
to indicate the right reply is received.PING
Yellow
indicator is
on
Equipment will send 5 ICMP packets to
network management center, for each
ICMP packet, use 1-5 port indicators to
indicate the right reply is not received.
CRC
Green
indicator is
on
Port has CRC error frame statistics.
STORM
Green
indicator is
on
Port is storm port.
NoMAC
Green
indicator is
on
Port does not learn MAC.
Off No connection.
Green
indicator is
on
Gigabit connection is created.Debugging
network
interface
indicator
At the
bottom
right of the
debugging
network
interface
None
Green
indicator is
flashing
Data is transferred.
3. Power indicator
Power has two indicators including PoE PWR and FAULT.
3-34
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
ZXR10 2928E-PS power indicator descriptions are listed as Table 3-23.
Table 3-23 ZXR10 2928E-PS Power Indicator Descriptions
Indicator Position Status Description
Off Power is off.
RUN
At the bottom left
of the panel with
the AC power
module
Green indicator
is onPower operates normally.
OffThe power supply is not on or the
power supply has no faults/alarms.FAULT
At the bottom left
of the panel with
the AC power
moduleRed indicator is
on
A power supply temperature alarm or
a fault exists, or no DC output exists.
Uplink Daughter Cards
2928E-PS provides users a slot for an expansion card of various forms to implement theuplink function of the device. Available uplink daughter cards include:
l RS-29EC-4GE-SFP daughter card
Caution!
An RS-29EC-4GE-SFP daughter card is unavailable for hot swap.
An RS-29EC-4GE-SFP daughter card provides 4–way gigabit Ethernet uplink opticalinterfaces, see Figure 3-18.
Figure 3-18 Front Panel of RS-29EC-4GE-SFP
On the panel of RS-29EC-4GE-SFP, four indicators are provided corresponding to thefour gigabit Ethernet uplink optical interfaces. For the descriptions of the indicators,refer to Table 3-24.
3-35
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Table 3-24 Descriptions of RS-29EC-4FE-SFP Indicators
Indicator Mode Off Green Yellow
Green indicator is on:
1G Link
Yellow indicator is on:
100M LinkGigabit optical
interface
indicator
SDP modeUncon-
nected Green indicator is
flashing: 1G Active
Yellow indicator is
flashing: 100M Active
l RS-29EC-4GE-RJ45 daughter card
Caution!
An RS-29EC-4GE-RJ45 daughter card does not support hot swap.
An RS-29EC-4GE-RJ45 daughter card provides 4 gigabit Ethernet uplink electricalinterfaces, see Figure 3-19.
Figure 3-19 Front Panel of RS-29EC-4GE-RJ45
The panel of RS-29EC-4GE-RJ45 has four indicators corresponding to the four gigabitelectrical interfaces, respectively. For descriptions, refer to Table 3-25.
Table 3-25 Descriptions of Indicators on RS-29EC-4GE-RJ45
Indicator Mode Off Green Yellow
Green indicator is on:
1G Link
Yellow indicator is on:
100/10M LinkGigabit
electrical
interface
indicator
SDPmodeUncon-
nected Green indicator is
flashing: 1G Active
Yellow indicator is flashing:
100/10M Active
l RS-29EC-4FE-SFP daughter card
3-36
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Caution!
An RS-29EC-4FE-SFP daughter card does not support hot swap.
An RS-29EC-4FE-SFP daughter card provides 4 100M Ethernet uplink opticalinterfaces, see Figure 3-20.
Figure 3-20 Front Panel of RS-29EC-4FE-SFP
The panel of RS-29EC-4FE-SFP has four indicators corresponding to the four 100Moptical interfaces, respectively. For descriptions, refer to Table 3-26.
Table 3-26 Descriptions of Indicators on RS-29EC-4FE-SFP
Indicator Off Green
Green indicator is on: 100M Link100M optical interface
indicatorUnconnected Green indicator is flashing: 100M
Active
3.1.7 Optical Module
OverviewThe interface board of the ZXR10 2900E switch uses pluggable optical modules calledSmall Form-factor Pluggable (SFP), see Figure 3-21.
3-37
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Figure 3-21 SFP
Attributes of SFP
For the attributes of an SFP optical module, refer to Table 3-27.
Table 3-27 Attributes of SFP
AttributeMMF/500 MPort
SMF/10 KMPort
SMF/40 KMPort
SMF/80 KMPort
SMF/120KM Port
Transmission
distance
500 m 10 km 40 km 80 km 120 km
Central
wavelength
850 nm 1310 nm 1310 nm/1550
nm
1550 nm 1550 nm
Minimum optical
transmission
power
-9.5 dBm -11.5 dBm -11.5 dBm -11.5d Bm -11.5 dBm
Maximum optical
transmission
power
-4 dBm -3 dBm -3 dBm -3 dBm -3 dBm
Receiving
sensitivity
<-19 dBm <-19d Bm <-19 dBm <-19 dBm <-19 dBm
Overload optical
power
0 dbm -3 dbm -3 dbm -3 dbm -3 dbm
Fiber type Multi-mode Single-mode Single-mode Single-mode Single-
mode
3-38
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
3.2 Cables
3.2.1 Power CablePower cable can be divided into three types according to different power modules: ACpower cable, DC power cable and RPS.
1. Connection of AC Power Cable
For the appearance of an AC power cable of the ZXR10 2900E, see Figure 3-22.
Figure 3-22 Appearance of an AC Power Cable
1. 10 A internationalstandard 3-pin flatmale plug
2. 3×0.75mm2 powercable (with 3Ccertification)
3. 10 A internationalstandard T-shapedfemale plug
For the models and specifications of the AC power cables of the ZXR10 2900E, referto Table 3-28.
Table 3-28 Technical Parameters of AC Power Cables
Item Description
10 A international standard 3-pin flat male plugTerminal model
10 A international standard T-shaped female plug
Cable model 3 × 0.75mm2, with 3C certification
2. Connection of DC Power Cable
DC -48 V power cable C-PWR-084 is shown in Figure 3-23.
Figure 3-23 DC Power Cable C-PWR-084 Diagram
Corresponding relationship between two ends of DC power cable is as shown in Table3-29.
3-39
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Table 3-29 Corresponding Relationship between Two Ends of DC Power Cable
End A End B Power Signal
1 End B1 -48 V GND
2 End B2 -48 V
End A is connected to a -48 V input socket of the device, and two terminals on endB shall be connected according to labels pasted on each conductor, where B1 isconnected to DC power supply -48 VGND and B2 is connected to DC power supply-48 V. The details on B1 and B2 labels are shown in Table 3-30.
Table 3-30 Label Details
End B1 End B2
-48 V GND -48 V
3. RPS550 Power cable
The RPS550 power supply cable used by ZXR10 2918S-PS is shown as , the ratingoperating voltage is 250 V, the rating operational current is 30 A.
The core wire corresponding relation of RPS cable is listed as Table 3-31.
Table 3-31 RPS550 Core Wire Corresponding Table
Pin of End A Cable Color Pin of End B
2 Black 1
3 Black 3
End A connects ZXR10 2918E-PS, End B connects RPS power device developed byZTE.
For device connection, end A connects to the RPS input end on the ZXR10 2918E-PSrear board, and end B connects to the output end of the ZTE RPS550 power supply,as shown in Figure 3-24.
3-40
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Figure 3-24 ZXR10 2918E-PS and RPS550 Connection Diagram
4. RPS1100 Power cable
The ZXR10 2918E-PS uses the RPS1100 power supply cable, as shown in Figure3-25. The rated cable operating voltage is 250 V, and rated operating current is 20 A.
Figure 3-25 RPS1100 Power Supply Cable
Core wires relations of the RPS cable are shown in Table 3-32.
Table 3-32 RPS1100 Core Wire Corresponding Table
Pin of End A Cable Color Pin of End B Pin of End C
2 Black 1 1
3 Blue 3 3
For device connection, end A connects to the RPS input end on the ZXR10 2918E-PSrear board, and end B connects to the output end of the ZTE RPS1100 power supply,as shown in Figure 3-26.
3-41
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Figure 3-26 ZXR10 2918E-PS and RPS1100 Connection Diagram
3.2.2 Protective CablesProtective grounding cables prevent the switch from lightning and interference. For theappearance of a protective grounding cable, see Figure 3-27.
Figure 3-27 Appearance of a Protective Grounding Cable
Technical Parameters
For the technical parameters of protective grounding cables of the ZXR10 2900E switch,refer to Table 3-33.
Table 3-33 Technical Parameters of Protective Grounding Cables
Parameter Description
Diameter of the main grounding cable 4 mm²
Size of the main grounding screw M4
Diameter of the main grounding cable lug 6.3 mm
3-42
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Installation Steps
Caution!
Correctly connecting the switch ground wire is crucial to the lightning protection andelectromagnetic susceptibility (EMS) of a switch.
The power input end of the switch is connected to a noise filter, whose central groundis directly connected to the chassis, forming the chassis ground (commonly known asPGND). This chassis ground must be securely connected to the earth ground so that thefaradism and leakage electricity can be safely released to the ground, enhancing the EMScapability of the switch.
The correct grounding methods are as below:
l If a grounding strip is available on the installation site, attach one end of theyellow/green ground wire of the switch to the grounding screw on the grounding stripand fasten the captive nut, see Figure 3-28. (Note that the fire main and lightning rodof a building are not suitable for grounding the switch. The ground wire of the switchshould be connected to the grounding device for the equipment room).
Figure 3-28 Grounding the Switch through a Grounding Strip
1. Protective groundingterminal of the switch
2. Grounding bar in theequipment room
l When there is no grounding strip but earth near the equipment room that allows agrounding body to be buried, hammer an angle iron/steel pipe longer than 0.5 m into
3-43
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
the earth, see Figure 3-29. Weld the yellow-green ground wire of the switch onto theangle iron/steel pipe, and process the joint against erosion.
Figure 3-29 Grounding the Switch by Burying the Grounding Body into the Earth
1. Protective groundingterminal of the switch
2. Ground 3. Angle steel or steeltube
l For an AC-powered switch, if none of the above two conditions is available, groundit through the PE wire of the AC power supply, see Figure 3-30. In this case, makesure this PE wire is well connected to the ground at the power distribution room or ACtransformer side.
3-44
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Figure 3-30 Grounding through the AC PE Wire
1. AC power input 2. PE protectivegrounding cable
l For a DC-powered switch, if none of the first two conditions is available, ground itthrough the return wire (RTN) of the DC power supply, see Figure 3-31. In this case,make sure this RTN wire is well connected to the ground at the DC output of the DCpower cabinet.
Figure 3-31 Grounding through the PGND of a Power cabinet
1. AC/DC power cabinet2. -48V bar
3. -48V4. RTN bar
5. -48VRTN6. PGND bar
3-45
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
7. Grounding8. Ground wire
9. Ground terminal10. DC input
3.2.3 Serial Console CableSerial console cable is the basic cable used in configuring and maintaining ZXR10 2900E.
Serial configuration line is provided together with ZXR10 2900E, one end to be DB9console port (connected to serial port of PC) and the other end to be RJ45 port (connectedto Console port on main Board of ZXR10 2900E).
The serial console cable is shown in Figure 3-32.
Figure 3-32 ZXR10 2900E Serial Console Cable Diagram
1. D-type 9-core plasticinjection molded cable plug(hole)
2. Label/self-covering winderlaser print II
3. Horizontal twisted pairSBVVP-2 × 2
4. 8P8C straight cable crimpplug
Line order of serial console cable is shown in Table 3-34.
Table 3-34 Serial Console Cable Line Order Table
End A Cable Chromatogram End B
2 White 3
3 Blue 6
White 45
Orange 5
4 White 7
6 Green 2
7 White 8
8 Brown 1
3.2.4 Network CableThere are two types of Ethernet cables: crossover and straight-through.
3-46
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
Straight-through Ethernet cables are used in the following cases.
l Ethernet connection between ZXR10 2900E and line concentrator.l Ethernet connection between ZXR10 2900E and Ethernet switch.l Ethernet connection between computer and line concentrator.l Ethernet connection between computer and Ethernet switch.
Crossover Ethernet cables are used in the following cases.
l Ethernet connection between two ZXR10 2900E devices.l Ethernet connection between ZXR10 2900E and computer Ethernet card.l Ethernet connection between two line concentrators.l Ethernet connection between line concentrator and Ethernet switch.l Ethernet connection between two Ethernet switches.l Ethernet card connection between two computers.
Both crossover and straight-through Ethernet cables are standard shielded cables that useRJ45 connectors. Structure of the Ethernet cable is shown in Figure 3-33.
Figure 3-33 Ethernet cable
1. RJ45 crystal headconnector
2. Network cable label3. Network cable sleeve
4. Twisted-pair wire
The corresponding relationship between straight-through cable core wires and pin positionis described in Table 3-35.
Table 3-35 Straight-through Ethernet Cable Sequence
Wire Color Code End A End B Wire Color Code Legend
White orange 1 1 White orange
Orange 2 2 Orange
White green 3 3 White green
Blue 4 4 Blue
White blue 5 5 White blue
3-47
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Wire Color Code End A End B Wire Color Code Legend
Green 6 6 Green
White brown 7 7 White brown
Brown 8 8 Brown
The corresponding relationship between crossover cable core wires and pin position isdescribed in Table 3-36.
Table 3-36 Crossover Ethernet Cable Sequence
Wire Color Code End A End B Wire Color Code Legend
White orange 1 3 White green
Orange 2 6 Green
Wihite green 3 1 Orange white
Blue 4 4 Blue
White blue 5 5 White blue
Green 6 2 Orange
White brown 7 7 White brown
Brown 8 8 Brown
Technical parameters of the Ethernet cable (straight-through and crossover) are describedin Table 3-37.
Table 3-37 Technical Parameters of Ethernet Cable
Cable plug name Model Technical parameters
8P8C straight cable crimp plug E5088-001023 Rated current: 1.5 A; rated
voltage: 125 V; crimp
AWG24-28# WG round cable
3.2.5 Fiber
OverviewOptical fiber is a communication medium that uses a bundle of thin glass rods to transmitthe modulated light. There are two fiber types: single mode fiber and multimode fiber. Theuser may select one according to the particular situation.l Multimode fiber: transmitting signals by using the multiple modes of light; used for
short-distance transmission; usually named as the 8.3/125 um fiber.
3-48
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 3 Hardware Descroption
l single mode fiber: transmitting signals by using the single mode of light; used forlong-distance transmission; usually named as the 50/125 um or 62.5/125 um fiber.
Each fiber cable is composed of five parts: fiber core, cladding layer, buffer layer,strengthening layer and outer jacket. Fiber core is the optical transmission componentlocated at the cable core. It is usually made of silicon or glass. The chemical compositionsof fiber core are partially different from those of the cladding layer, so that the lightentering at a specified angle would be reflected continuously by fiber core and claddinglayer. Therefore, light remains in the fiber core during the whole transmission process.
The Physical cross-sectional area of a fiber cable is shown in Figure 3-34. The figureshows the location of the five components.
Figure 3-34 Fiber Cable Cross-sectional Area
Laser Usage Safety
The ZXR10 2900E series Ethernet switch belongs to type I laser equipment.
If an optical interface of the ZXR10 2900E series switch is in working state, do not look atthe interface directly. The beam emitted by the fiber has very great energy, and looking atit directly will damage your retina.
Note:
It will hurt your eyes to have eye contact with laser beams of optical fiber.
Fiber Installation
Each optical interface of the ZXR10 2900E can be connected to an SFP module. Forthe supported rates, refer to the model description. Two types of fibers are available:single-mode fiber andmulti-mode fiber. User can configure the fiber according to the actualapplication. Table 3-38 shows 6 types of fiber.
3-49
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Table 3-38 Fiber Type Table
Mode Switch End Connector Type Opposite End Connector Type
FC/PC Connector
SC/PC ConnectorSingle-mode fiberSC-PC Connector (Square
Panhead)ST/PC Connector
FC/PC Connector
SC/PC ConnectorMulti-Mode FiberSC-PC Connector (Square
Panhead)ST/PC Connector
As for fiber out of the cabinet, make sure to protect the fiber against any damages withplastic corrugated sleeve. The fiber within the protect sleeve must not be wound up andthe corners must be radian. The labels at two ends of the fiber must be clear. The meaningof the label must correctly reflect corresponding serial numbers and relationship betweencabinets and between rows.
3-50
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 4InstallationTable of Contents
Desktop Installation ....................................................................................................4-1Cabinet Installation.....................................................................................................4-1Cable Laying ..............................................................................................................4-6Lightning Protection of the Switch(Optional) ...............................................................4-8
4.1 Desktop InstallationTo install a switch on the desktop, install four plastic bottom blocks (plastic bottom blocksare strews provided together with the device) on the bottom plate of the switch to form anair passage. Through the air passage, the heat generated by the power module can bedissipated efficiently. The detailed installation is shown in Figure 4-1 (taking ZXR10 2952Efor example).
Figure 4-1 Desktop Installation
1. Box 2. Bottom block
4.2 Cabinet InstallationZXR10 2918E/2928E/2952E/2918E-PS Installation
1. To install ZXR10 2918E/2928E/2952E/2918E-PS onto a 19-inch cabinet, fix twoflanges (both flanges and screws are provided together with the device) on two sidesof the switch shell, see Figure 4-2 (taking ZXR10 2952E for example).
4-1
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Figure 4-2 Installation of Flanges
2. Install a pair of symmetric holding plates inside the 19-inch cabinet to supportswitching, see Figure 4-3.
Figure 4-3 Installation of Holding Plates
3. After fixing holding plates, push in switch along the holding plates and fix flanges ontothe cabinet, see Figure 4-4 (taking ZXR10 2952E for example).
4-2
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 4 Installation
Figure 4-4 Fixing Device
ZXR10 2910E-PS Installation
1. To install ZXR10 2910E-PS onto a 19-inch cabinet, fix two flanges (both flanges andscrews are provided together with device) on two sides of the switch shell, see Figure4-5.
Figure 4-5 Installation of Flanges (ZXR10 2910E-PS)
2. Install a pair of symmetric holding plates inside the 19-inch cabinet to supportswitching, see Figure 4-6.
4-3
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Figure 4-6 Installation of Holding Plates (ZXR10 2910E-PS)
3. After fixing holding plates, push in switch along the holding plates and fix flanges ontothe cabinet, see Figure 4-7 .
Figure 4-7 Fixing Device (ZXR10 2910E-PS)
ZXR10 2928E-PS Installation
1. To install ZXR10 2928E-PS onto the 19-inch cabinet, fix two flanges (both flanges andscrews are provided together with the switch) on two sides of the switch shell. SeeFigure 4-8.
4-4
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 4 Installation
Figure 4-8 Flange Installation
2. Install a pair of symmetric holding plates on inner sides of the 19-inch cabinet to supportthe switch. See Figure 4-9.
Figure 4-9 Holding Plate Installation
3. After fixing holding plates, push in the switch along the holding plates and fix flangesonto the cabinet. See Figure 4-10 .
Figure 4-10 Fixing the Switch
4-5
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
4.3 Cable LayingThe ZXR10 2900E cables consist of group wire, power cable, serial console cable, networkcable and fiber.
4.3.1 Installation Specifications
Installation Specifications for Power Cables and Grounding Cables
l Layout Principles
Power cables are straight and with smooth arcs at turning sections.
No connecting or wielding point exists in the middle of a power cable.
The extra part of a cable is cut off, instead of being coiled.
The bending radius at a turning section of a power cable is 5 times greater than thecable diameter.
Power cables are laid properly, without crossing, coiling, or twisting.
Before a signal cable is installed, a connectivity test must be carried out. Both endsof the signal cable are attached with marks or engineering tags.
Power cables and signaling cables are separated by at least 300mm. Do not bindthem together.
For an optical fiber, the turning radius is not less than 4cm.
l Binding Principles
Power cables and signal cables are bound separately.
The binding interval of power cables is 200mm.
Do not let turning components (such as a door) press or drag the cables, and bindingis not allowed at turning sections.
Wire fasteners are facing the same direction. Cut the excessive part after binding,and the cutting is even.
l Overhead Cabling Principle
In overhead cabling mode, the cables are routed out of the top of the DC powerdistribution cabinet to the top of each device cabinet through a cable try.
l Raised-floor Cabling Principle
In raised-floor cabling mode, the cables are routed out of the bottom of the DC powerdistribution cabinet to the bottom of each device cabinet through the anti-static floor.
Installation Steps
1. Plan the cabling path.
When planning the cabling path, take future expansion into consideration, so that thesystem can still operate properly after expansion.
4-6
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 4 Installation
2. Install protective grounding cables and power cables.
Before installing power cables, ensure that the protective grounding cables of theswitch contact the earth well. For details of how to install grounding cables and powercables, refer to Section 3.2 "Cables".
3. Install signal cables.l Install configuration cables.l Lay network cables.l Lay optical fibers.
For details of how to install signal cables, refer to Section 3.2 "Cables".
4.3.2 Power-on ProcedureCheck the lab environment and hardware installation before power-on ZXR10 2900E.
1. To make sure that the switch operates normally and has a normal service life, thecertain temperature and humidity of equipment room should be maintained.l If the humidity of the equipment room has been too high for a long time,
leakage will happen or the insulating function will not good. Sometimes materialmechanical feature will change or metal components will rust. If the relativehumidity is too low, the insulating pad will shrink and cause loose of fastenedscrew. At the same time, static will happen which endangers the circuit of switch.
l The harm of high temperature is larger. The longtime high temperature will speedthe aging process of insulating material, which reduces the reliability of switch andaffects the life of the switch.
2. Check whether the power cable and other cables are connected correctly and reliably.3. Check other hardware.
a. Check whether devices are labeled completely, correctly and clearly.
b. Check whether the switch is firmly installed in a 19-inch standard rack or ondesktop.
c. Check whether rack has a good contact and whether the earthing resistancemeetstechnical requirements.
4. Power on ZXR10 2900E in the following steps:
a. Connect the switch AC power cable.
b. Turn on the external power supply.
5. Power off ZXR10 2900E in the following steps:
a. Turn off the external power supply.
b. Disconnect the switch AC power cable.
4-7
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
4.4 Lightning Protection of the Switch(Optional)
4.4.1 Installation of Lightning Arrester for AC Power
Caution!
Lightning arrester will not be delivered with the switch. You should purchase it if needed.
If an outdoor AC power cord should be directly led to the switch, serially connect thelightning arrester for AC power (Socket Strip with Lightning Protection) before you plugthe AC power cord into the switch, thus to prevent possible damages to the switch due tolightning strike. You can use cable clips and screws to fasten the lightning arrester for ACpower on the cabinet, workbench or the wall of equipment room. A lightning arrester isshown as Figure 4-11.
Figure 4-11 Diagram of Lightning Arrester
1. Multipurpose socket:connects the device power.
2. Standard socket: connectsthe equipment room powerthrough a power cable.
3. Grounding alarm indicator:indicates whether thepower has PE. If yes, theindicator is off. Otherwise,the indicator is on.
4. Reversed polarity indicator:indicates whether L and Nare connected reversely.If yes, the indicator is on.Otherwise, the indicator isoff.
5. Lightning protectionindicator: indicates whetherthe lightning protectionfunction is normal. If yes,
the indicator is green.Otherwise, the indicator isred.
6. Lightning protection module7. Grounding screw8. Hanger, fixed by an M6
screw9. Power Socket switch10. Fuse
4-8
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 4 Installation
Caution!l Make sure that the arrester is well grounded before using the lightning arrester for
power.l After inserting AC power cord plug of switch into the socket of lightning arrester, if the
green LED is on and the red LED does not alarm, it means that the lightning arresterof power is running and the function of lightning protection has taken effect.
l When the arrester is installed, users should install and debug according to theinstruction to arrester and comply with the engineering technical requirementsin GB50343 Building Electronic Information System lightning- proof TechnologySpecification and YD/T5098 Telecommunication Bureaus (Stations) LightingOvervoltage Protection Engineering Design Specification, which ensures reasonablegrounding, bonding and isoelectric connection.
l The security of lightning- proof system should be checked regularly such as the checkbefore and after each thunderstorm season including if the lightning- proof moduleof device is damaged or performance is not good, if the bonding performance ofconnection is not good. If these conditions above happen, please change or handlein time.
4.4.2 Installation of Lightning Arrester for Network Port
Note:
Lightning arrester for network port is specially designed for the Ethernet port of 10/100Melectrical interface (RJ-45 connector is used in this case).
Caution!
Lightning arrester for network port will not be provided along with the switch, and youshould purchase it if needed.
If an outdoor network cable should be led to the switch, serially connect the lightningarrester for network port before you plug this cable into the interface on the switch, incase of the possibility that the switch may be damaged due to lightning strike.
Tools
l Phillips screwdriver or Flat-blade screwdriverl Multimeterl Tilted wire cutter
4-9
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
Installation procedure
1. Tear the protection paper at one side of the double faced adhesive tape apart from thetape, and stick the tape on the surface of the arrester. Tear the protection paper atanother side apart from the tape, and stick the arrester onto the chassis of the switch.The arrester should be attached on the chassis as close to the grounding screw aspossible.
2. According to the distance to the grounding screw of the switch, cut the ground wireof the arrester, and securely tightening its ground wire to the grounding screw of theswitch.
3. Use a multimeter to measure whether the ground wire of the arrester contacts wellwith the grounding screw of chassis.
4. According to the instruction of arrester for network port, connect the arrester with switchby the cables (be carefully with the cable direction. Outdoor network cable should beinserted into the arrester‘s IN end, and the cable connected to the switch should beinserted into the arrester’s OUT end). When you do that, observe whether the arresterindicators normally display.
Note:
When an arrester is installed, users should install and debug according to theinstruction to arrester and comply with the engineering technical requirementsin GB50343 Building Electronic Information System lightning- proof TechnologySpecification and YD/T5098 Telecommunication Bureaus (Stations) LightingOvervoltage Protection Engineering Design Specification, which ensures reasonablegrounding, bonding and isoelectric connection.
5. Use the nylon ties to bundle the cables neatly.
Installation of lightning arrester for network port is shown as Figure 4-12.
4-10
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
Chapter 4 Installation
Figure 4-12 Installation Diagram of Lightning Arrester For Network Port
Installation precautions
Fully consider the following items in the installation process, otherwise, the performanceof the lightning arrester for network port will be affected:
l Lightning arrester for network port is installed in reverse direction. In practice, the“IN” end should be connected to the outdoor network cable and the “OUT” end to thenetwork port on the switch.
l Lightning arrester for the network port is not well grounded. The ground wire for thearrester should be as short as possible to ensure its good contact with the groundingscrew of the switch. After the connection, use the multimeter to confirm that.
l The lightning arrester for the network port is not installed completely. If the switch hasmore than one network port to interconnect to other devices via cables outdoor, installlightning arresters for all these network ports for protection.
4-11
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
ZXR10 2900E Series Hardware Manual
This page intentionally left blank.
4-12
SJ-20120409144109-001|2012-07-02(R1.0) ZTE Proprietary and Confidential
FiguresFigure 3-1 ZXR10 2918E AC Model Front Panel....................................................... 3-3
Figure 3-2 ZXR10 2918E DC Model Front Panel ...................................................... 3-3
Figure 3-3 ZXR10 2928E AC Model Front Panel....................................................... 3-8
Figure 3-4 ZXR10 2928E DC Model Front Panel ...................................................... 3-8
Figure 3-5 ZXR10 2952E Front Panel ..................................................................... 3-13
Figure 3-6 ZXR10 2952E Back Panel (AC power)................................................... 3-14
Figure 3-7 ZXR10 2952E Back Panel (DC power)................................................... 3-14
Figure 3-8 ZXR10 2910E-PS Front Panel ............................................................... 3-18
Figure 3-9 ZXR10 2910E-PS 45/78 line pair for power supply................................. 3-19
Figure 3-10 ZXR10 2918E-PS Front Panel ............................................................. 3-23
Figure 3-11 ZXR10 2918E-PS Back Panel .............................................................. 3-23
Figure 3-12 Front Panel of RPS550 ........................................................................ 3-24
Figure 3-13 Front Panel of RPS1100 ...................................................................... 3-24
Figure 3-14 ZXR10 2918E-PS 45/78 line pair for power supply............................... 3-25
Figure 3-15 ZXR10 2928E-PS Front Panel ............................................................. 3-30
Figure 3-16 Rear Panel of the AC Modularized Power Supply in ZXR102928E-PS ............................................................................................. 3-30
Figure 3-17 ZXR10 2928E-PS 45/78 Line Pair for Power Supply ............................ 3-31
Figure 3-18 Front Panel of RS-29EC-4GE-SFP ...................................................... 3-35
Figure 3-19 Front Panel of RS-29EC-4GE-RJ45..................................................... 3-36
Figure 3-20 Front Panel of RS-29EC-4FE-SFP....................................................... 3-37
Figure 3-21 SFP ..................................................................................................... 3-38
Figure 3-22 Appearance of an AC Power Cable...................................................... 3-39
Figure 3-23 DC Power Cable C-PWR-084 Diagram ................................................ 3-39
Figure 3-24 ZXR10 2918E-PS and RPS550 Connection Diagram........................... 3-41
Figure 3-25 RPS1100 Power Supply Cable............................................................. 3-41
Figure 3-26 ZXR10 2918E-PS and RPS1100 Connection Diagram......................... 3-42
Figure 3-27 Appearance of a Protective Grounding Cable ...................................... 3-42
Figure 3-28 Grounding the Switch through a Grounding Strip ................................. 3-43
Figure 3-29 Grounding the Switch by Burying the Grounding Body into theEarth..................................................................................................... 3-44
Figure 3-30 Grounding through the AC PE Wire ..................................................... 3-45
I
ZXR10 2900E Series Hardware Manual
Figure 3-31 Grounding through the PGND of a Power cabinet ................................ 3-45
Figure 3-32 ZXR10 2900E Serial Console Cable Diagram ...................................... 3-46
Figure 3-33 Ethernet cable...................................................................................... 3-47
Figure 3-34 Fiber Cable Cross-sectional Area......................................................... 3-49
Figure 4-1 Desktop Installation.................................................................................. 4-1
Figure 4-2 Installation of Flanges .............................................................................. 4-2
Figure 4-3 Installation of Holding Plates.................................................................... 4-2
Figure 4-4 Fixing Device .......................................................................................... 4-3
Figure 4-5 Installation of Flanges (ZXR10 2910E-PS)............................................... 4-3
Figure 4-6 Installation of Holding Plates (ZXR10 2910E-PS)..................................... 4-4
Figure 4-7 Fixing Device (ZXR10 2910E-PS) ............................................................ 4-4
Figure 4-8 Flange Installation.................................................................................... 4-5
Figure 4-9 Holding Plate Installation.......................................................................... 4-5
Figure 4-10 Fixing the Switch.................................................................................... 4-5
Figure 4-11 Diagram of Lightning Arrester................................................................. 4-8
Figure 4-12 Installation Diagram of Lightning Arrester For Network Port ................. 4-11
II
TablesTable 2-1 ZXR10 2900E Technical Features and Parameters ................................... 2-3
Table 3-1 Technical Parameters of ZXR10 2910E-PS/2918E-PS Fans...................... 3-2
Table 3-2 Technical Parameters of ZXR10 2928E-PSS Fans .................................... 3-2
Table 3-3 ZXR10 2918E Interface Descriptions......................................................... 3-4
Table 3-4 ZXR10 2918E System Indicators............................................................... 3-5
Table 3-5 ZXR10 2918E Port Indicator Description ................................................... 3-5
Table 3-6 ZXR10 2928E Interface Descriptions......................................................... 3-9
Table 3-7 ZXR10 2928E System Indicators............................................................. 3-10
Table 3-8 ZXR10 2928E Port Indicator Description ................................................. 3-10
Table 3-9 ZXR10 2952E Interface Descriptions....................................................... 3-14
Table 3-10 ZXR10 2952E System Indicators ........................................................... 3-15
Table 3-11 ZXR10 2952E Port Indicator Description................................................ 3-16
Table 3-12 ZXR10 2910E-PS Interface Descriptions ............................................... 3-18
Table 3-13 ZXR10 2910E-PS System Indicators ..................................................... 3-20
Table 3-14 ZXR10 2910E-PS Port Indicator Description.......................................... 3-20
Table 3-15 ZXR10 2910E-PS Power Indicator Descriptions .................................... 3-22
Table 3-16 ZXR10 2918E-PS Interface Descriptions ............................................... 3-25
Table 3-17 ZXR10 2918E-PS System Indicators ..................................................... 3-26
Table 3-18 2918E-PS Port Indicator Description ..................................................... 3-26
Table 3-19 ZXR10 2918E-PS Power Indicator Descriptions .................................... 3-29
Table 3-20 ZXR10 2928E-PS Interface Descriptions ............................................... 3-31
Table 3-21 ZXR10 2928E-PS System Indicators ..................................................... 3-32
Table 3-22 2928E-PS Port Indicator Description ..................................................... 3-32
Table 3-23 ZXR10 2928E-PS Power Indicator Descriptions .................................... 3-35
Table 3-24 Descriptions of RS-29EC-4FE-SFP Indicators ....................................... 3-36
Table 3-25 Descriptions of Indicators on RS-29EC-4GE-RJ45 ................................ 3-36
Table 3-26 Descriptions of Indicators on RS-29EC-4FE-SFP .................................. 3-37
Table 3-27 Attributes of SFP ................................................................................... 3-38
Table 3-28 Technical Parameters of AC Power Cables............................................ 3-39
Table 3-29 Corresponding Relationship between Two Ends of DC PowerCable ..................................................................................................... 3-40
Table 3-30 Label Details ......................................................................................... 3-40
III
ZXR10 2900E Series Hardware Manual
Table 3-31 RPS550 Core Wire Corresponding Table............................................... 3-40
Table 3-32 RPS1100 Core Wire Corresponding Table ............................................. 3-41
Table 3-33 Technical Parameters of Protective Grounding Cables .......................... 3-42
Table 3-34 Serial Console Cable Line Order Table .................................................. 3-46
Table 3-35 Straight-through Ethernet Cable Sequence............................................ 3-47
Table 3-36 Crossover Ethernet Cable Sequence..................................................... 3-48
Table 3-37 Technical Parameters of Ethernet Cable................................................ 3-48
Table 3-38 Fiber Type Table.................................................................................... 3-50
IV