XR550 SeRieS Bank aTM SySTeM - DMP · XR550 Series Bank ATM System ... for banks with Bank Safe &...

2
XR550 SERIES BANK ATM SYSTEM SYSTEM FEATURES • Selectable arming & disarming options • 32 individual reporting areas, with common areas • Up to 16 supervised door access-points and/or keypads • 32 character names available for user, zone, area, profiles and group names • ATM size enclosure • Up to 4 profiles per user • Fully supervised 10/100 network and 3G/4G cellular communication • Communications Diagnostics check network and cellular communication status from the keypad. • Eight communication paths between the panel and Central Station • Up to three separate protected systems • 10,000 user codes with 99 profiles • 506 Outputs • 12,000 event buffer • Card plus pin and temporary codes • Built-in phone line monitor • Multi-lingual menus available by user • 1.5 Amps 12 VDC smoke and auxiliary output with OVC protection • User inactivity audit • SimpleNET persistent connection for the DMP App XR550DN/XR550DE SYSTEM FEATURES • Bank, Safe and Vault Operation • Two Man Rule, Panic Button Test and Early Morning Ambush XR550DE SYSTEM FEATURES • 128 Bit AES (Advanced Encryption Standard) Encryption • NIST Certified • Meets ICPG 705 Delivers the dependable communication flexibility required for an on-site or remote ATM bank branch, and is secure, cost-effective, and small enough for use in a single ATM. • Many arming & disarming options that ensure your ATM's are secure • On site programmable from laptop or keypad. Programmable over Network, GSM or dialup. • For backup up communication simply add the DMP 263C or 263H Cellular Communicator that requires no additional enclosures, power supplies, batteries, or cabling Take advantage of built-in networking and encryption features offered with the XR550N or XR550E panels. XR550N shown with 263C Digital Communicator and 383 Rubberduck Antenna; additional antennas available. 341 Panel Enclosure sold separately. Search dmpalarms

Transcript of XR550 SeRieS Bank aTM SySTeM - DMP · XR550 Series Bank ATM System ... for banks with Bank Safe &...

Page 1: XR550 SeRieS Bank aTM SySTeM - DMP · XR550 Series Bank ATM System ... for banks with Bank Safe & Vault operation, Two-Man Rule ... their PIN code or access credentials during a

XR550 SeRieS Bank aTM SySTeM

SySTeM FeaTUReS• Selectablearming&disarmingoptions• 32individualreportingareas,withcommonareas• Upto16superviseddooraccess-pointsand/orkeypads• 32characternamesavailableforuser,zone,area,profilesandgroupnames

• ATMsizeenclosure• Upto4profilesperuser• Fullysupervised10/100networkand3G/4Gcellularcommunication

• CommunicationsDiagnosticschecknetworkandcellularcommunicationstatusfromthekeypad.

• EightcommunicationpathsbetweenthepanelandCentralStation

• Uptothreeseparateprotectedsystems• 10,000usercodeswith99profiles• 506Outputs

• 12,000eventbuffer• Cardpluspinandtemporarycodes• Built-inphonelinemonitor• Multi-lingualmenusavailablebyuser• 1.5Amps12VDCsmokeandauxiliaryoutputwithOVCprotection

• Userinactivityaudit• SimpleNETpersistentconnectionfortheDMPApp

XR550Dn/XR550De SySTeM FeaTUReS• Bank,SafeandVaultOperation• TwoManRule,PanicButtonTestandEarlyMorningAmbush

XR550De SySTeM FeaTUReS• 128BitAES(AdvancedEncryptionStandard)Encryption• NISTCertified• MeetsICPG705

Delivers the dependable communication flexibilityrequiredforanon-siteorremoteATMbankbranch,andissecure,cost-effective,andsmallenoughforuseinasingleATM.

• Manyarming&disarmingoptionsthatensureyourATM'saresecure

• Onsiteprogrammablefromlaptoporkeypad.ProgrammableoverNetwork,GSMordialup.

• ForbackupupcommunicationsimplyaddtheDMP263Cor263HCellularCommunicatorthatrequiresnoadditionalenclosures,powersupplies,batteries,orcabling

Takeadvantage of built-in networking andencryptionfeaturesofferedwiththeXR550NorXR550Epanels.

XR550Nshownwith263CDigitalCommunicatorand383RubberduckAntenna;additionalantennasavailable.

341PanelEnclosuresoldseparately.

Searchdmpalarms

Page 2: XR550 SeRieS Bank aTM SySTeM - DMP · XR550 Series Bank ATM System ... for banks with Bank Safe & Vault operation, Two-Man Rule ... their PIN code or access credentials during a

© 2

013

Dig

ital M

onito

ring

Prod

ucts

, Inc

. |

LT-1

235

| 7/1

3

Intrusion | Fire | Access | Network | Cellular 2500 North Partnership BoulevardSpringfield, Missouri 65803-8877

800.641.4282 | dmp.comDesigned, Engineered & Assembledin Springfield, Missouri

XR550 Series Bank ATM System

aUToMaTic aRMing/ DiSaRMingTheXR550Seriesuseaspecialarming/disarmingzone, triggered from the shunt on the ATMCombinationLockorastandarddoor contact toautomatically disarm/rearm the system.Whenservice is complete, use the normal keypadsequencetoarmtheATM.Anoptionalentrydelaytimecanbeprogrammed.IftheATMortopperisnot closedat theendof theexit delay time, thezone force arms and sends amessage to theCentralStation.

coMBinaTion lock aRMingUsing a KABA-MAS, Seargent-Greenleaf,LaGuard or other combination safe lockwithshunt output, the XR550Series automaticallydisarmswhen the lock isopened,and rearmswhen it is lockedshut again. Additionally youcanarmordisarmthesystemwithastandardDMPKeypadorWiegandoutputreaderdevice.

Special Bank FeaTUReSTheXR550NandXR550EprovidegreatersecurityforbankswithBankSafe&Vaultoperation,Two-ManRule,PanicButtonTest,andEarlyMorningAmbushfeatures.

eighT coMMUnicaTion paThSCreate, configure and manage up to eightcommunicationpathsbetweenthepanelandCentralStation.Eachpathhasitsownpanelcommunicationprogrammingparameters,andcanbeidentifiedaseitherprimaryorbackup.Thisenables installerstoconfigureareliablecommunicationlink,offeringgreater confidence that thepanelwill alwaysbeconnectedtotheCentralStation.

WiReleSS one BUTTon keyFoB WiTh pRoX paTchThe1145-1-BP is awearable andportablepanicbutton fob,programmable to function inmultiplebranches,withalertsforlostfobs,latetotest,andlowerbatterypower.

SpeciFicaTionSPrimaryPower(included) 16.5VAC50VAtransformerSecondaryPower 12VDCBatteryModels 364,365,366,368or369

OutputRatingBell 1.5Ampsat12VDCSmokeandAuxiliary 1.5Ampsat12VDC

CurrentDraw 183mADimensions 13.5”X7.0”X3.5”Enclosure 20-gaugecoldrolledsteel

Includesa36”batterychargingcable.One318requiredfortwo7ahbatteries.One318Rrequiredforoneortwo18ahbatteries.

neTWoRk oR cellUlaR coMMUnicaTionBuilt-in 10/100auto-sensingEthernet connectionenhancesbothstandardandencryptedlinesecurityoptions.BothUDPandTCPare supported. Thenetwork option can be used as the primary orbackuppathtothedigitaldialerorcellularoption.The 263C/263H p lug- in D ig i ta l Ce l lu larCommunicator canbeusedas theprimarypath,providing installation flexibilitywhere no landlinesareavailable.Itcanbeusedasastand-alonecommunicatorwithout the need for a backup.When used as the backup path, the 263C/263Hprovidesthesecurityofacommunicationlinkthatcontinuestofunction,evenwhenlandlinesarecutor compromised. This interfaceworksondigitalCellular CDMAorHSPA+data networks over avarietyofcarriersintheUSAandCanadaandCDMAdatanetworksinCanada.

aTM Size encloSURe With big security features, the XR550 Seriescomes in anATMsize enclosure to fit nearlyanywhere. At less than half the size of thesmalleststandardsecurityenclosure,theXR550Seriesevenfitsinthesmalleststand-aloneATMunits.

USeR coDeSEachof10,000usercodescanbeassignedoneof99differentprofilesforaccesstocombinationsofareasorATMs.

USeR inacTiviTyTheUser inactivity audit provides notificationof user codes or credentials not used over aprogrammable period of time. For example,employeesorserviceprovidesthathaven’tusedtheirPIN codeor access credentials duringadefinedperiodoftime.Thisnotificationpromotesthepurgingofuserandaccessrightsasaresultof employee termination or service providerchanges.ThisoptionisfoundinSystemOptionsProgramming.

zone aUDiT DaySZoneAuditDaysprovideanalertwhenanintrusionor panic zone has not changed status in thearmedordisarmedstateoveraprogrammableperiodoftime.Thealertincludesthezonenameandnumber. This feature is a valuable tool inmaintainthehighestlevelofsecurityaswellasintegrityofthesystem.ThisfeaturecanbefoundinZoneInformation–AdvancedOptions.

aUToMaTic BURglaRy SySTeM DiSaRMingSince theXR550 isan integratedburglaryandaccesscontrolsystem,ausercangainaccessanddisarmthesite,allinasinglecardread!

acceSSoRieS•263C/263HDigitalCellularCommunicator(comeswith383Antenna)

•270NetworkTransientSuppressor•341BBatteryBracketforusewith364•381-110"CoaxExtensionCable•381-1212FootSMAExtensionCable•381-218"CoaxExtensionCable•381-2525FootSMAExtensionCable•383DualBandRubberDuckAntenna•385-DualBandSmartDiscAntenna•386WallMountAntennaBracket•387SeriesAntennas&ExtensionCables•716OutputExpansionModule•734WiegandInterfaceModule•734NNetworkWiegandInterfaceModule•734N-WiFiWiegandInterfaceModule•860RelayOutputModule•893ADualPhoneLineModule•DMPReadersandCredentials•PotterVibrationSensors,Contacts,Hold-upButtons,SoundAlarms

•1100SeriesWireless

liSTingS anD appRovalSFCCPart68FCCPart15NISTValidatedCertificate#2350

UnderwritersLaboratories(UL)Listed ULBank,Safe,andVault ULStandardLineSecurity ULEncryptedLineSecurity

UnderwritersLaboratoriesCanada(ULC)Listed

Foradditionalapprovalinformation,accesswww.dmp.comandselectCompliance.