Compressor Step 1. Plea Local Altitude (0 - 10,000 Max. Ambient Operating Tem Max. Ambient Relative Humi Step 2. Enter The Air Tool / Equipment Quantity Example- 1/2" Impact Wrench 20 Example- 1" Grinder 1 Based on the air consumption indicate Horsepower: Receiver Tank (gal): Thi - A duplex compressor has built-in redund - A Quiet Power series compressor reduces - A rotary screw can operate 24/7 w

Transcript of napaaircompressors.comnapaaircompressors.com/NAPA-Sizing-Ca… · XLS file · Web view ·...

Page 1: napaaircompressors.comnapaaircompressors.com/NAPA-Sizing-Ca… · XLS file · Web view · 2014-02-06Compressor Sizing Calculator Air Tool / Equipment CFM Per Tool Example- 1/2"

Compressor Sizing CalculatorStep 1. Please Enter Your Site Conditions

Local Altitude (0 - 10,000 ft)

Max. Ambient Operating Temperature (ºF)

Max. Ambient Relative Humidity (%)

Step 2. Enter The Air Consumption of Your ToolsAir Tool / Equipment Quantity CFM Per Tool

Example- 1/2" Impact Wrench 20 5

Example- 1" Grinder 1 12

Total CFM For Equipment =Total CFM Needed Based on Site Conditions =

Based on the air consumption indicated, you should consider a compressor with at least:

Horsepower: 12Receiver Tank (gal): 120

Things to consider…- A duplex compressor has built-in redundancy and can provide the most cfm on single phase power

- A Quiet Power series compressor reduces employee fatigue and provides a better work environment- A rotary screw can operate 24/7 without stopping and carries the longest warranty

Page 2: napaaircompressors.comnapaaircompressors.com/NAPA-Sizing-Ca… · XLS file · Web view · 2014-02-06Compressor Sizing Calculator Air Tool / Equipment CFM Per Tool Example- 1/2"

Compressor Sizing CalculatorStep 1. Please Enter Your Site Conditions

2,000

65

0

Step 2. Enter The Air Consumption of Your ToolsHourly Use Factor % Total

40% 40.0040% 4.80

0.000.000.000.000.000.000.000.000.000.00

Total CFM For Equipment = 44.80Total CFM Needed Based on Site Conditions = 47.55

Based on the air consumption indicated, you should consider a compressor with at least:

(If gas drive, 30 gal tank is good)Things to consider…

- A duplex compressor has built-in redundancy and can provide the most cfm on single phase power- A Quiet Power series compressor reduces employee fatigue and provides a better work environment

- A rotary screw can operate 24/7 without stopping and carries the longest warranty