Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

35
www.oasys- software.com Predicting Human Induced Vibration with GSA Footfall

Transcript of Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

Page 1: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Predicting Human Induced Vibration with GSA Footfall

Page 2: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Today’s Team

Peter Debney

Application Specialist

Nigel Rees

SalesManager

Page 3: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Today’s Team

Peter Debney

Application Specialist

Rhys Lewis

Consultant

Page 4: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

1. Viewer Window 2. Control Panel

Oasys Software : GSA Footfall

If you cannot hear, please

check this setting

GoToWebinar Attendee Interface

Page 5: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Agenda

• Product Demonstration• GSA

• Questions and Answers

NB: this webinar is designed as an introduction to GSA and footfall and is designed to provide an overview.

Page 6: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Who is Oasys?

• Wholly owned by Arup

• Formed in 1976 to develop software for in-house and external use

• Most developers are engineers who have moved to programming

• In recent years have added marketing and sales staff

• Since 2003 have expanded the development team worldwide

• Wide network of resellers and channel partners

Page 7: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Oasys Customers

Page 8: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Structural

Geotechnical

CAD

Document Management

Sustainability

Crowd simulation

Page 9: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

The ProblemVibration

Page 10: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

The effects of vibration

•Structural Damage• Inelastic response – overload• Fatigue

•Discomfort• Bouncy floors and stairs• Wind-induced sway of buildings• Ride comfort• Noise• Machine operation

•Machine operability• High precision manufacturing

facilities• Medical facilities• Laboratories

Page 11: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

The effects of vibration

•Structural Damage• Inelastic response – overload• Fatigue

•Discomfort• Bouncy floors and stairs• Wind-induced sway of buildings• Ride comfort• Noise• Machine operation

•Machine operability• High precision manufacturing

facilities• Medical facilities• Laboratories

Page 12: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

What is Footfall?

Human induced vibration

Page 13: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

What is Footfall?

Page 14: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

What is Footfall?

Vibration

(a) A bridge as a simply supported beam

(b) The first mode of vibration

(c) The displacement of mid-span after someone jumps once at mid-span

Page 15: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

What is Footfall?

Vibration

Page 16: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

What is Footfall?

Vibration

Page 17: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Results

Velocities and Accelerations

f = 1 / T

ω = 2 π f

x = X sin ωt

v = Xω cos ωt

a = -Xω2 sin ωt

Page 18: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Results

What is R?

BS 6472 base curve for human perception

Page 19: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Modal mass

F = ma a = F/m

Page 20: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Resonance

1st harmonic

Page 21: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Resonance

2nd harmonic

Page 22: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Resonance

3rd harmonic

Page 23: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Resonance

4th harmonic

Page 24: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Damping

-1

-0.8

-0.6

-0.4

-0.2

0

0.2

0.4

0.6

0.8

1

0 5 10 15 20 25

Dis

plac

emen

t

Time

Damped Free Vibration

Damping 0.1 of critical

Critical Damping

Page 25: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Steady State Resonant Amplification Factors for SDOF systems

0

5

10

15

20

25

0 0.5 1 1.5 2 2.5 3

(excitation frequency)/(natural frequency)

Am

pli

ficati

on

Facto

r

0.02 damping

0.05 damping

0.10 damping

0.20 damping

Resonance and DampingDynamic amplification under harmonic (single

frequency) loading

1 - staticexcitation too fast for any significant response

resonance

Page 26: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Resonance and DampingDynamic amplification with multiple

harmonics

Page 27: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Resonance and DampingDynamic amplification with multiple

harmonics

Page 28: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Transient Response – Impulse loading

Page 29: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Footfall Design Guides

Page 30: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Footfall - Simple Method

f0 = 18 / √δ

Page 31: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Footfall - FEA Method

Page 32: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Footfall - FEA Method

Page 33: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

The Solution

Page 34: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

Any Questions?

Page 35: Www.oasys-software.com Predicting Human Induced Vibration with GSA Footfall.

www.oasys-software.com

• Contact Details• Peter Debney – [email protected]• Nigel Rees – [email protected]

• Next Webinars• August 15th: Raft and Soil-Structure Interaction• September 19th: Concrete Design

Webinar has now Ended