WORK PLAN ADDENDUM · 2020-03-03 · GZA GeoEnvironmental, Inc. (R&W/GZA), has prepared this Work...
Transcript of WORK PLAN ADDENDUM · 2020-03-03 · GZA GeoEnvironmental, Inc. (R&W/GZA), has prepared this Work...
WORK PLAN ADDENDUM House Street Disposal AreaPlainfield Township, Kent County, Michigan
November 15, 2019 File No. 16.0062335.52
PREPARED FOR: Wolverine World Wide, Inc. Rockford, Michigan
Rose & Westra, a Division of GZA GeoEnvironmental, Inc. 601 Fifth Street NW | Suite 102 | Grand Rapids, MI 49504 616.956.6123
30 Offices Nationwide www.gza.com
Copyright© 2019 GZA GeoEnvironmental, Inc.
952073
Submitted Via Email Only November 15, 2019 File No. 16.0062335.52 Mr. Jeffrey Kimble, On-Scene Coordinator (OSC) United States Environmental Protection Agency - Region 5 2565 Plymouth Road Ann Arbor, MI 48105 Re: Work Plan Addendum House Street Disposal Site, Plainfield Township, Kent County, Michigan Dear Mr. Kimble: On behalf of Wolverine World Wide, Inc. (Wolverine), Rose & Westra, a Division of GZA GeoEnvironmental, Inc. (R&W/GZA), has prepared this Work Plan Addendum for the former Wolverine House Street Disposal Site in Plainfield Township, Kent County, Michigan. This Work Plan Addendum is being completed pursuant to the October 28, 2019 U.S. EPA Region 5 Administrative Settlement Agreement and Order on Consent for Removal Actions (AOC)1. Very truly yours, Rose & Westra, A Division of GZA GeoEnvironmental, Inc. Loretta J. Powers Jiangeng (Jim) Cai, P.E. Senior Project Manager Senior Consultant Mark A. Westra Principal Attachment j:\62000\623xx\62335.52 - house st pre-inv\0 - task 006 - 2019 workplan\work plan addendum\62335_52_housest_2019workplan addendum-f.docx
1 Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Docket No. V-W-20-C-002
November 15, 2019 WP Addendum
House Street Disposal Site, Plainfield Township, Kent County, Michigan File No. 16.0062335.52
TOC i
1.0 INTRODUCTION ................................................................................................................................... 1
2.0 SITE BACKGROUND .............................................................................................................................. 1
3.0 CERCLA ACTION ITEMS ......................................................................................................................... 1
WP 3.6 TCLP SOIL .......................................................................................................................................... 1
WP 3.6.1 TCLP Soil Delineation .................................................................................................................... 1 WP Task 3.6.2 TCLP Soil Capping .................................................................................................................. 1
4.0 OFF-SITE MIGRATION CONTROL ........................................................................................................... 2
5.0 INVESTIGATION-DERIVED WASTE DISPOSAL ........................................................................................ 2
6.0 ANTICIPATED SCHEDULE ...................................................................................................................... 2
7.0 REFERENCES ........................................................................................................................................ 2
APPENDED FIGURES FIGURE 1 PROPOSED CAPPING PLAN WITH DETAILS FIGURE 2 CHROMIUM TCLP AREAS 1 AND 5 FIGURE 3 CHROMIUM TCLP AREA 2 FIGURE 4 CHROMIUM TCLP AREA 3 FIGURE 5 CHROMIUM TCLP AREA 4
Acronym Definition
AOC Agreement and Order on Consent for Removal Actions
CERCLA Comprehensive Environmental Response, Compensation, and Liability Act
EPA United States Environmental Protection Agency
GRGCC MDEQ Part 201 Generic Residential Groundwater Cleanup Criteria
GCL Geosynthetic Clay Liner
HDPE High Density Polyethylene
LLDPE Linear Low-Density Polyethylene
PFAS Perfluoroalkyl and Polyfluoroalkyl Substances
R&W/GZA Rose & Westra, a Division of GZA GeoEnvironmental, Inc.
Site House Street Site, 1855 House Street NE, Plainfield Township, Michigan
TCLP Toxicity Characteristic Leaching Procedure
VOCs Volatile Organic Compounds
TCRA Time Critical Response Action (as defined by EPA)
Wolverine Wolverine World Wide, Inc.
WP Work Plan
November 15, 2019 WP Addendum
House Street Disposal Site, Plainfield Township, Kent County, Michigan File No. 16.0062335.52
Page 1 of 16
1.0 INTRODUCTION
On behalf of Wolverine, R&W/GZA prepared this WP Addendum as a follow up to the July 12, 2019 WP. This WP Addendum incorporates the additional delineation sampling data collected in June - August 2019 and serves as the amendment referenced in Section 6.0 of the WP. This Work Plan Addendum is being completed in response to the AOC entered into by Wolverine and EPA on October 28, 2019.
2.0 SITE BACKGROUND
Site background is provided in Section 2.0 of the WP.
3.0 CERCLA ACTION ITEMS
This section of the WP Addendum updates the planned responses to the action item identified in Section 3.6.2 of the WP (TCLP Soil Excavation). The AOC entered into by Wolverine and EPA on October 28, 2019 provides for capping soil in lieu of excavation.
WP 3.6 TCLP SOIL
During the 2018 investigation, chromium concentrations exceeded the TCLP screening value in six waste material samples (two of which were in one boring at different depths). This results in five areas with chromium TCLP exceedances. The AOC entered into by Wolverine and EPA on October 28, 2019 provides for these materials to be capped in place. Accordingly, the following section discusses the capping of these areas based on the investigation and delineation activities conducted in 2018 and 2019.
WP 3.6.1 TCLP Soil Delineation
Task 3.6.1 was completed during June, July, and August 2019. The results from the delineation have been incorporated into the capping plans proposed in the following sections.
WP Task 3.6.2 TCLP Soil Capping
Soil and/or waste material above the chromium TCLP threshold (TCLP Chromium Areas) have been delineated and will be capped in place. Figure 1 shows the approximate locations of capping Areas 1 through 5 as well as the typical details and section for the caps. Figure 2 through Figure 5 show the delineation borings and area details for TCLP Chromium Areas 1 through 5.
Site Preparation Activities
The Site preparation tasks are described in Section 3.6.2 of the WP.
Capping of Chromium TCLP Soil/Waste Material
The five TCLP Chromium Areas will be capped using geomembrane in accordance with the details provided on Figure 1. Generally, each TCLP Chromium Area, plus approximately 10 feet on each side, will be cleared and grubbed, and the area will be graded so that the cap will shed water, with a slope of approximately 1.6:1, as depicted on Figure 1. If needed, subgrade material (sand or gravel, as determined by the Engineer), will be placed over the graded area prior to cap placement.
November 15, 2019 WP Addendum
House Street Disposal Site, Plainfield Township, Kent County, Michigan File No. 16.0062335.52
Page 2 of 16
The cap will consist of a liner, followed by 12-inch clean cover soil, and approximately 6 inch top soil with seeding. The liner, either HDPE geomembrane, LLDPE geomembrane, or GCL, will be placed over each of the graded TCLP Chromium Areas and will extend 10 feet past the limit of the Areas. The liner will be anchored using an anchor trench as specified in Figure 1. The liner will then be covered with 12 inches of “clean” fill soil, topsoil, and seeded. Fill material will be analyzed for metals, VOCs, SVOCs, and PFAS to confirm that the material is “clean” prior to being accepted for placement on-Site.
Site Restoration
Section 3.6.2 describes the applicable site restoration.
4.0 OFF-SITE MIGRATION CONTROL
Off-Site Migration Control is described in Section 4.0 of the WP.
5.0 INVESTIGATION-DERIVED WASTE DISPOSAL
While expected to be minimal, investigation-derived waste disposal is described in Section 5.0 of the WP.
6.0 ANTICIPATED SCHEDULE
R&W/GZA has completed the following tasks from the WP:
• The delineation of the TCLP Chromium Soil Areas and off-site investigations have been completed.
• The fencing installation has been completed.
The schedule for the capping will be established once the proposed specifications are approved. The schedule will be provided as a separate submittal. Upon completion of the capping, a summary of the 2019 TCRA tasks and capping will be provided to EPA within 90 days.
7.0 REFERENCES
R&W/GZA. 2018. Extent of Contamination Study Removal Work Plan, House Street Disposal Area, Plainfield Township, Kent County, Michigan. Submitted to EPA May 29, 2018.
R&W/GZA. 2018. Field Sampling Plan, House Street Disposal Area. Submitted to USEPA May 30, 2018.
R&W/GZA. 2018. Health and Safety Plan, Former Wolverine Tannery and House Street Disposal Area. Submitted to EPA May 29, 2018.
R&W/GZA. 2018. Quality Assurance Project Plan, Former Wolverine Tannery and House Street Disposal Area, Revision 2. Submitted to EPA August 29, 2018 with errata pages submitted October 31, 2018 and April 15, 2019.
R&W/GZA. 2019. HSDS Implementation of the 2018 Work Plan Summary Report. Submitted to EPA May 21, 2019.
USEPA. 2019. RE: Wolverine Tannery and House Street Disposal State: Required CERCLA Actions. Letter dated April 29, 2019.
November 15, 2019 WP Addendum
House Street Disposal Site, Plainfield Township, Kent County, Michigan File No. 16.0062335.52
Page 3 of 16
USEPA. 2019. RE: Work Plan, House Street Disposal Area, Plainfield Township, Kent County, Michigan: Approval with Significant Modifications. Letter dated June 27, 2019.
USEPA. 2019. Administrative Settlement Agreement and Order on Consent for Removal Actions. CERCLA Docket No. V-W-20-C-002. Dated October 28, 2019.
FIGURES
AREA 3
AREA 4
AREA 2
AREA 1
AREA 5
AC
CE
SS
R
OA
D
UTILITY EASEMENT
APPROXIMATE LIMITS
OF WASTE MATERIAL
AC
CE
SS
R
OA
D
APPROXIMATE LIMITS
OF WASTE MATERIAL
APPROXIMATE LIMITS
OF WASTE MATERIAL
0
0
20 40 60 80 120100 140
1
2
3
4
5
6
7
8
APPROXIMATE
EXISTING GRADE
CLEAR & GRUB EXISTING
TOPSOIL & BRUSH (TYP.)
PLACE ANCHOR TRENCH
10' PAST LIMIT OF WASTE
EDGE OF TCLP
CHROMIUM AREA
100'±
0
.5
' T
O
P
S
O
IL
&
S
E
E
D
IN
G
SUBGRADE
GCL OR GEOMEMBRANE
1
2
" C
O
V
E
R
S
O
IL
(S
E
E
N
O
T
E
2
C
)
TCLP CHROMIUM AREA
0.5' TYP.
EDGE OF TCLP
CHROMIUM AREA
T
Y
P
IC
A
L
D
R
A
IN
A
G
E
(S
E
E
N
O
T
E
5
)
SHEET NO.
PROJECT NO.DATE: REVISION NO.
DESIGNED BY:
PROJ MGR:
DRAWN BY:
REVIEWED BY: CHECKED BY:
SCALE:
PREPARED BY:PREPARED FOR:
GZAGeoEnvironmental, Inc.
Engineers and Scientists
www.gza.com
HOUSE STREET SITE
PLAINFIELD TOWNSHIP, MICHIGAN
AREA #1 - #5 SITE PLAN, TYPICAL DETAILS & SECTION
WN&J/WWW
OCTOBER 2019 16.0062335.52
FIGURE
1
LP
RJ
JF
MT
EH
1" = 100'
0 50' 100' 200' 300'
SCALE IN FEET 1'' = 100'
N
S
EW
LEGEND:
PROPERTY BOUNDARY
LIMITS OF WASTE
UTILITY EASEMENT
DRAFT
WELD
LLDPE OR HDPE
4" MIN.
TYPICAL GEOMEMBRANE FILLET EXTRUSION WELD
NOT TO SCALE
TYPICAL CAP ANCHOR TRENCH
NOT TO SCALE
VARIES
1
GCL, LLDPE OR HDPE
BACKFILL
12" MIN. OVERLAP
UNDERLYING PANEL
0.25 lbs/FT GRANULAR BENTONITE
OVERLYING
PANEL
GCL LONGITUDINAL (SIDE) SEAM DETAIL
NOT TO SCALE
GCL END OF PANEL (BUTT) SEAM DETAIL
NOT TO SCALE
UNDERLYING PANEL
OVERLYING
PANEL
0.25 lbs/FT GRANULAR BENTONITE
24" MIN. OVERLAP
36"18"
24"
SUMMARY OF AREA DIMENSIONS
MAX LENGTH (FT.) MAX WIDTH (FT.) APPROXIMATE AREA (SF.)
AREA 1 85 23 1682
AREA 2 28 24 565
AREA 3 68 26 1327
AREA 4 26 21 511
AREA 5 97 35 2296
TYPICAL GEOMEMBRANE HOT WEDGE DOUBLE
TRACK FUSION WELD
NOT TO SCALE
4" MIN. TO 6" MAX.
AIR CHANNEL
SQUEEZE-OUT
LLDPE OR HDPE
NOTES:
1. GEOSYNTHETIC CLAY LINER (GCL) AND GEOMEMBRANE OVERLAP SHOWN FOR DISCUSSION
PURPOSES. CONSTRUCTED PANEL OVERLAP AND SEAM TO BE CONSISTENT WITH
MANUFACTURER'S RECOMMENDATIONS, REGULATORY REQUIREMENTS, THE STATE OF THE
PRACTICE, AND PROJECT SPECIFICATIONS.
2. SPECIFICATIONS FOR TYPICAL COMPONENTS OF THE LINER AND CAP TO BE PROVIDED. FOR
DISCUSSION PURPOSES, CONSIDER:
a. 20-MIL MINIMUM GEOMEMBRANE TO BE LINEAR LOW DENSITY POLYETHYLENE
(LLDPE) OR HIGH DENSITY POLYETHYLENE (HDPE)
b. GEOSYNTHETIC CLAY LINER CETCO BENTOMAT CL
c. 12-INCH COVER SOIL TO CONSIST OF CLEAN FILL SOILS, SUITABLE FOR PLACEMENT
AND USE AS COVER. SITE SOILS MAY BE ACCEPTABLE CONTINGENT ON SOIL SAMPLE
TESTING BOTH ANALYTICAL (CHEMICAL CONSTITUENTS) AND ENGINEERING INDEX
PROPERTIES. OFF-SITE CLEAN FILL THAT MEETS THE GRADUATION REQUIREMENTS
OF MDOT TABLE 902-3, CLASS I, OR TABLE 902-4, 2NS OR 2SSe ARE SUITABLE
3. TOPSOIL AND SEED TO BE COMPATIBLE WITH COVER SOIL AND BE CONSISTENT WITH MDOT
REQUIREMENTS, SEE MDOT SPECIFICATIONS, SECTION 917.
4. TYPICAL ROLL DIMENSIONS:
a. BENTOMAT CL (GCL) TYPICALLY AT 15-FT WIDE BY 150-FT LONG
b. HDPE GEOMEMBRANE PANELS TYPICALLY AT 23-FT WIDE BY 500+FT LONG
5. DRAINAGE WILL BE DEPENDENT ON SPECIFIC AREA AND EXISTING TOPOGRAPHY. EXISTING
GRADES AT EACH SPECIFIC AREA VARY BY ABOUT 2 FEET ±. FINAL GRADES TO MIRROR
EXISTING GRADE AND SURFACE WATER RUN-OFF.
TYPICAL CAP CROSS-SECTION
HORIZONTAL AND VERTICAL SCALE AS SHOWN IN FEET
NOTE: CONFIGURATION WILL VARY BY TCLP CHROMIUM AREA.
#0 #0 #0
#0#0
#0#0 #0
#0 #0 #0
#0 #0
#0 #0 #0
#0
#0
#0
#0#0 #0 #0
#0
#0#0
#0#0
#0
#0
#0
#0
#0
#0
#0#0
#0
#0
#0 #0
#0#0
#0
#0
#0
#0
#0
#0
#0
#0 #0
#0#0
#0 #0
#0
#0#0
#0
#0
#0
#0
#0
#0#0#0
!
!
!
!
!
!! !! !!
!!
!!
!!!!
!!
!! !!!!
!!
!!
!!
!!
!! !! !!!!
!
!
!!
!!
!!
!!!!
!!
!!
!!
!!
!!
!! !!
!!
!!
!!
!
!!
!!!!
!!
!!!!
!!
!!
!!
(
(
(
(
(
(( (( ((
((
((
((((
((
(( ((((
((
((
((
((
(( (( ((((
(
(
((
((
((
((((
((
((
((
((
((
(( ((
((
((
((
(
((
((((
((
((((
((
((
((
!
!
!(
(
(
!(
!
!!
(
((
AREA 1
AREA 5
SB-4100 SB-4101 SB-4102SB-4103
SB-4104SB-4105
SB-4106 SB-4107
SB-4132 SB-4133
SB-4134
SB-4135 SB-4136
SB-4137 SB-4138 SB-4139
SB-4206SB-4208
SB-4210
SB-4264SB-4265
SB-4266 SB-4267SB-4268
SB-4269SB-4270
SB-4271
SB-4272
SB-4274
SB-4301
SB-4300
SB-4302
SB-4304
SB-4303
SB-4306SB-4200
SB-4400
SB-4401
SB-4403SB-4407
SB-4406SB-4402
SB-4405SB-4404
SB-4308
SB-4307
SB-4309
SB-4408
SB-4409
SB-4410 SB-4413
SB-4412SB-4411
SB-4416 SB-4417
SB-4415
SB-4414
SB-4420
SB-4419SB-4418
SB-4313
SB-4312
SB-4310
SB-4311
SB-4315SB-4314
Area= 1679 Square FtMax Length= 85 FtMax Width= 23 Ft
Area= 2293 Square FtMax Length= 97 FtMax Width= 35 Ft
© 20
19 - G
ZA G
eoEn
viron
menta
l, Inc
. J:
\16.xx
Gran
d Rap
ids\16
.0062
300.x
x\16.0
0623
35.5x
WNJ
WW
W\16
.0062
335.5
2\Data
_GIS\
GIS_
CAD\
HS_T
CLP_
Inves
tigati
on_L
etterS
ize.m
xd, 1
1/15/2
019,
11:59
:19 A
M, ju
lie.gr
oenle
er
0 30 6015
Scale in FeetUNLESS SPECIFICALLY STATED BY WRITTEN AGREEMENT, THIS DRAWING IS THE SOLE PROPERTY OF GZAGEOENVIRONMENTAL, INC. (GZA). THE INFORMATION SHOWN ON THE DRAWING IS SOLELY FOR USE BYGZA'S CLIENT OR THE CLIENT'S DESIGNATED REPRESENTATIVE FOR THE SPECIFIC PROJECT AND LOCATIONIDENTIFIED ON THE DRAWING. THE DRAWING SHALL NOT BE TRANSFERRED, REUSED, COPIED, OR ALTEREDIN ANY MANNER FOR USE AT ANY OTHER LOCATION OR FOR ANY OTHER PURPOSE WITHOUT THE PRIORWRITTEN CONSENT OF GZA. ANY TRANSFER, REUSE, OR MODIFICATION TO THE DRAWING BY THE CLIENT OROTHERS, WITHOUT THE PRIOR WRITTEN EXPRESS CONSENT OF GZA, WILL BE AT THE USER'S SOLE RISK ANDWITHOUT ANY RISK OR LIABILITY TO GZA.
Rose & Westra, a Division of GZA601 Fifth Street NW, Suite 102Grand Rapids, Michigan 49504
EXTENT OF TCLP CHROMIUM EXCEEDING RCRA MAX CONCENTRATIONHOUSE STREET 2019 TCLP INVESTIGATION -
AREA 1 AND AREA 5PREPARED FOR:
WN&J/WWW
PROJ MGR: LJPDESIGNED BY: JC
REVIEWED BY: LJPDRAWN BY: JC/JMG
CHECKED BY: LJPSCALE:
DATE:11/15/2019
PROJECT NO.16.0062335.52
REVISION NO.
FIGURE2
GZA GeoEnvironmental, Inc.Engineers and Scientists
www.gza.com
LEGEND2019 TCLP INVESTIGATION#0
NO WASTE MATERIALOBSERVED
#0 WASTE MATERIAL OBSERVED1966 PROPOSED SITE PLAN
APPROXIMATE HOUSE ST SITE BOUNDARY
TCLP ChromiumConcentration (ug/L)
!( 0 - 310!( 310.00001 - 950!( 950.00001 - 1,600!( 1,600.00001 - 5,000!( 5,000.00001 - 18,000
Extent of Cr TCLPExceeding RCRA MaxConcentration
Extent of Cr TCLP ExceedingRCRA Max Concentration 1 " = 30 '
.
NOTE:1. BORING LOCATIONS ARE PRECEDED BY THE SITE CODE "HS-" ON BORING LOGSAND SAMPLE NAMES.
#0 #0 #0
#0#0
#0 #0 #0
#0
#0
#0#0
!!
!!
!!!!!!
!!
!!!!
!!!!
((
((
((((((
((
((((
((((
!(
AREA 2
SB-4506 SB-4505
SB-4504
SB-4500SB-4501
SB-4507 SB-4508SB-4509
SB-4503SB-4502
SB-4510SB-4511
Area= 560 Square FtMax Length= 28 FtMax Width= 24 Ft
© 20
19 - G
ZA G
eoEn
viron
menta
l, Inc
. J:
\16.xx
Gran
d Rap
ids\16
.0062
300.x
x\16.0
0623
35.5x
WNJ
WW
W\16
.0062
335.5
2\Data
_GIS\
GIS_
CAD\
HS_T
CLP_
Inves
tigati
on_L
etterS
ize.m
xd, 1
1/15/2
019,
12:02
:44 P
M, ju
lie.gr
oenle
er
0 30 6015
Scale in FeetUNLESS SPECIFICALLY STATED BY WRITTEN AGREEMENT, THIS DRAWING IS THE SOLE PROPERTY OF GZAGEOENVIRONMENTAL, INC. (GZA). THE INFORMATION SHOWN ON THE DRAWING IS SOLELY FOR USE BYGZA'S CLIENT OR THE CLIENT'S DESIGNATED REPRESENTATIVE FOR THE SPECIFIC PROJECT AND LOCATIONIDENTIFIED ON THE DRAWING. THE DRAWING SHALL NOT BE TRANSFERRED, REUSED, COPIED, OR ALTEREDIN ANY MANNER FOR USE AT ANY OTHER LOCATION OR FOR ANY OTHER PURPOSE WITHOUT THE PRIORWRITTEN CONSENT OF GZA. ANY TRANSFER, REUSE, OR MODIFICATION TO THE DRAWING BY THE CLIENT OROTHERS, WITHOUT THE PRIOR WRITTEN EXPRESS CONSENT OF GZA, WILL BE AT THE USER'S SOLE RISK ANDWITHOUT ANY RISK OR LIABILITY TO GZA.
Rose & Westra, a Division of GZA601 Fifth Street NW, Suite 102Grand Rapids, Michigan 49504
EXTENT OF TCLP CHROMIUM EXCEEDING RCRA MAX CONCENTRATIONHOUSE STREET 2019 TCLP INVESTIGATION -
AREA 2PREPARED FOR:
WN&J/WWW
PROJ MGR: LJPDESIGNED BY: JC
REVIEWED BY: LJPDRAWN BY: JC/JMG
CHECKED BY: LJPSCALE:
DATE:11/15/2019
PROJECT NO.16.0062335.52
REVISION NO.
FIGURE3
GZA GeoEnvironmental, Inc.Engineers and Scientists
www.gza.com
LEGEND2019 TCLP INVESTIGATION#0
NO WASTE MATERIALOBSERVED
#0 WASTE MATERIAL OBSERVED1966 PROPOSED SITE PLAN
APPROXIMATE HOUSE ST SITE BOUNDARY
TCLP ChromiumConcentration (ug/L)
!( 0 - 310!( 310.00001 - 950!( 950.00001 - 1,600!( 1,600.00001 - 5,000!( 5,000.00001 - 18,000
Extent of Cr TCLPExceeding RCRA MaxConcentration
Extent of Cr TCLP ExceedingRCRA Max Concentration 1 " = 30 '
.
NOTE:1. BORING LOCATIONS ARE PRECEDED BY THE SITE CODE "HS-" ON BORING LOGSAND SAMPLE NAMES.
#0
#0
#0 #0
#0
#0
#0 #0
#0
#0#0
#0
#0
#0
#0
#0
#0
#0 #0
#0
#0#0
#0
#0
#0#0
#0
!!
!
!!!
!!!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!! !!!!
!!!!
((
(
(((
((((
((
(
((
((
((
((
((
((
((
((
((
((
((
(( ((((
((((
!(
!(
AREA 3
SB-4728
SB-4701
SB-4705 SB-4703
SB-4716
SB-4730
SB-4719SB-4717
SB-4710SB-4712 SB-4714
SB-4708
SB-4715
SB-4718
SB-4706
SB-4711
SB-4704
SB-4720 SB-4722
SB-4702
SB-4709SB-4721
SB-4707
SB-4700
SB-4724SB-4726
SB-4713
Area= 1324 Square FtMax Length= 68 FtMax Width= 26 Ft
© 20
19 - G
ZA G
eoEn
viron
menta
l, Inc
. J:
\16.xx
Gran
d Rap
ids\16
.0062
300.x
x\16.0
0623
35.5x
WNJ
WW
W\16
.0062
335.5
2\Data
_GIS\
GIS_
CAD\
HS_T
CLP_
Inves
tigati
on_L
etterS
ize.m
xd, 1
1/15/2
019,
12:05
:37 P
M, ju
lie.gr
oenle
er
0 30 6015
Scale in FeetUNLESS SPECIFICALLY STATED BY WRITTEN AGREEMENT, THIS DRAWING IS THE SOLE PROPERTY OF GZAGEOENVIRONMENTAL, INC. (GZA). THE INFORMATION SHOWN ON THE DRAWING IS SOLELY FOR USE BYGZA'S CLIENT OR THE CLIENT'S DESIGNATED REPRESENTATIVE FOR THE SPECIFIC PROJECT AND LOCATIONIDENTIFIED ON THE DRAWING. THE DRAWING SHALL NOT BE TRANSFERRED, REUSED, COPIED, OR ALTEREDIN ANY MANNER FOR USE AT ANY OTHER LOCATION OR FOR ANY OTHER PURPOSE WITHOUT THE PRIORWRITTEN CONSENT OF GZA. ANY TRANSFER, REUSE, OR MODIFICATION TO THE DRAWING BY THE CLIENT OROTHERS, WITHOUT THE PRIOR WRITTEN EXPRESS CONSENT OF GZA, WILL BE AT THE USER'S SOLE RISK ANDWITHOUT ANY RISK OR LIABILITY TO GZA.
Rose & Westra, a Division of GZA601 Fifth Street NW, Suite 102Grand Rapids, Michigan 49504
EXTENT OF TCLP CHROMIUM EXCEEDING RCRA MAX CONCENTRATIONHOUSE STREET 2019 TCLP INVESTIGATION -
AREA 3PREPARED FOR:
WN&J/WWW
PROJ MGR: LJPDESIGNED BY: JC
REVIEWED BY: LJPDRAWN BY: JC/JMG
CHECKED BY: LJPSCALE:
DATE:11/15/2019
PROJECT NO.16.0062335.52
REVISION NO.
FIGURE4
GZA GeoEnvironmental, Inc.Engineers and Scientists
www.gza.com
LEGEND2019 TCLP INVESTIGATION#0
NO WASTE MATERIALOBSERVED
#0 WASTE MATERIAL OBSERVED1966 PROPOSED SITE PLAN
APPROXIMATE HOUSE ST SITE BOUNDARY
TCLP ChromiumConcentration (ug/L)
!( 0 - 310!( 310.00001 - 950!( 950.00001 - 1,600!( 1,600.00001 - 5,000!( 5,000.00001 - 18,000
Extent of Cr TCLPExceeding RCRA MaxConcentration
Extent of Cr TCLP ExceedingRCRA Max Concentration 1 " = 30 '
.
NOTE:1. BORING LOCATIONS ARE PRECEDED BY THE SITE CODE "HS-" ON BORING LOGSAND SAMPLE NAMES.
#0#0
#0
#0
#0#0
#0 #0
#0
#0
#0
!!!
!
!!
!
!
!
!
!
!
!!
!!
!!
!!!!
!!
!!
!!
(((
(
((
(
(
(
(
(
(
((
((
((
((((
((
((
((
!
!
!
!
!
(
(
(
(
(
!(
AREA 4
SB-4610SB-4604
SB-4609
SB-4600
SB-4608SB-4605
SB-4602SB-4607
SB-4603
SB-4606
SB-4601
Area= 506 Square FtMax Length= 26 FtMax Width= 21 Ft
© 20
19 - G
ZA G
eoEn
viron
menta
l, Inc
. J:
\16.xx
Gran
d Rap
ids\16
.0062
300.x
x\16.0
0623
35.5x
WNJ
WW
W\16
.0062
335.5
2\Data
_GIS\
GIS_
CAD\
HS_T
CLP_
Inves
tigati
on_L
etterS
ize.m
xd, 1
1/15/2
019,
12:04
:31 P
M, ju
lie.gr
oenle
er
0 30 6015
Scale in FeetUNLESS SPECIFICALLY STATED BY WRITTEN AGREEMENT, THIS DRAWING IS THE SOLE PROPERTY OF GZAGEOENVIRONMENTAL, INC. (GZA). THE INFORMATION SHOWN ON THE DRAWING IS SOLELY FOR USE BYGZA'S CLIENT OR THE CLIENT'S DESIGNATED REPRESENTATIVE FOR THE SPECIFIC PROJECT AND LOCATIONIDENTIFIED ON THE DRAWING. THE DRAWING SHALL NOT BE TRANSFERRED, REUSED, COPIED, OR ALTEREDIN ANY MANNER FOR USE AT ANY OTHER LOCATION OR FOR ANY OTHER PURPOSE WITHOUT THE PRIORWRITTEN CONSENT OF GZA. ANY TRANSFER, REUSE, OR MODIFICATION TO THE DRAWING BY THE CLIENT OROTHERS, WITHOUT THE PRIOR WRITTEN EXPRESS CONSENT OF GZA, WILL BE AT THE USER'S SOLE RISK ANDWITHOUT ANY RISK OR LIABILITY TO GZA.
Rose & Westra, a Division of GZA601 Fifth Street NW, Suite 102Grand Rapids, Michigan 49504
EXTENT OF TCLP CHROMIUM EXCEEDING RCRA MAX CONCENTRATIONHOUSE STREET 2019 TCLP INVESTIGATION -
AREA 4PREPARED FOR:
WN&J/WWW
PROJ MGR: LJPDESIGNED BY: JC
REVIEWED BY: LJPDRAWN BY: JC/JMG
CHECKED BY: LJPSCALE:
DATE:11/15/2019
PROJECT NO.16.0062335.52
REVISION NO.
FIGURE5
GZA GeoEnvironmental, Inc.Engineers and Scientists
www.gza.com
LEGEND2019 TCLP INVESTIGATION#0
NO WASTE MATERIALOBSERVED
#0 WASTE MATERIAL OBSERVED1966 PROPOSED SITE PLAN
APPROXIMATE HOUSE ST SITE BOUNDARY
TCLP ChromiumConcentration (ug/L)
!( 0 - 310!( 310.00001 - 950!( 950.00001 - 1,600!( 1,600.00001 - 5,000!( 5,000.00001 - 18,000
Extent of Cr TCLPExceeding RCRA MaxConcentration
Extent of Cr TCLP ExceedingRCRA Max Concentration 1 " = 30 '
.
NOTE:1. BORING LOCATIONS ARE PRECEDED BY THE SITE CODE "HS-" ON BORING LOGSAND SAMPLE NAMES.
GZA GeoEnvironmental, Inc.