WITH Integrated HFNC
Transcript of WITH Integrated HFNC
Integrated
H F N C
WITH
Remote Monitoringand Data Access
FDA EUA approved
FD
A EUA approved
F D A E U A a p p r o v e d
Prod
uct Made in India
● Premium Quality
●
www.electraventilator.com 03
GET REMOTE ACCESS TO CUSTOMIZED HEALTH CARE APP
• Provide live feed of ventilator to your mobile• Monitors alarm indications along with trigger count• Export data in PDF format• Detail reports along with time stamp• Stores patient pro�le with data log• Data portability via SD card• Provides graphic representation of tidal volume and proximal pressure
Electra Assist...
A HealthCare appto fill the gap
www.electraventilator.com 04
Technical Specifications
1) Disconnect (for Patient Tubing)
2) PEEP
3) Tidal Volume
4) P insp
5) Flow Alarm
6) Temperature Alarm
7) Respiratory Rate
Control Parameters
Display Parameters
VENTILATION
Tidal Volume
PIP (Peak Inspiratory Pressure)
I-PAP
PEEP (Positive End Expiratory Pressure)
EPAP/CPAP
CPAP-PS
FiO2
Breath Rate Per minute
I TIME
Apnea Backup Rate
HFT - High Flow Therapy
Respiratory Rate
Minute Ventilation Lpm
Tidal Volume
Fio2
Airway Pressure (Min, Mean, Max)
Plateau Pressure
Inspiratory Pressure
Flow
Airway Flow (For High �ow Therapy)
Airway Temperature (For High �ow Therapy)
100-1800 mL
5-70 cmH2o
5-40 cmH2o
0& 5-30 cmH2o
5-30 cmH2o
5-30 cmH2o
21-100%
4-40 bpm
0.1-3.0 sec
4-40 BPM
20-70 LPM
BPM
LPM
mL
%
cmH2o
cmH2o
cmH2o
LPM
LPM
˚C
8) FiO2
9) Machine Fault
10) Low Power (for Alarm Battery)
11) E-PAP
12) C-PAP
13) I-PAP
Alarms
Ventilator Mode Invasive
VC-CMV
VC-ACMV
PC-CMV
PC-ACMV
PC-SIMV
PRVC-ACMV
Non-Invasive
HFNC
CPAP
CPAP-PS
BiPAP-S/T
BiPAP-PS
Adult, Pediatric (Age 7 Years And Above , Weight 25 kg And Above)Patient Category
www.electraventilator.com 05
Monitoring Display
Oxygen Sensor
Gas Supply
Electrical Speci�cation
21-100%
Built - In Blower
Range 35 to 87 PSI
110 -240 VAC, 90 W Max,
50/60 Hz
9 v Alarm Battery
Numerical Display
Vertical Bar Chart
Volume, Pressure & Flow
Digital 7 inch Graphical Display*
Optical/Ultrasonic Oxygen Sensor
Accuracy + 2% @100% FiO2 With Auto Calibration
Air source Inlet
Oxygen Source High Pressure Diss Input
Ac Supply
Battery
Safety
Warranty
Dimensions
Product
Optional Accessories
440 x 340 x 310
9.2 KG
1
1
1
1
1
1
1
1
Electrical Safety IEC 60601-1, IEC 60601-2
Relief Valve for Excessive Pressure Cut-off
Alternate Breathing Airway In case of machine failure
Safety Valve
1 Year
Size L x W X H (mm)
Weight (Kg)
Description
EV Electra Ventilator
Power Cord
7 Inch Tablet with Mount and Interface Cable
High Pressure Diss Female Oxygen Hose
IPPB Patient Tubing Set with Bacterial Hme Filter
Bipap Mask
Adult Test Lung 1 Litre
Operating User Manual
UPS 110 /230 v 50/60 Hz 100 W
Complete Stand Assembly
Circuit Support Arm for Holding Patient Tubing
Automatic System Self-test On Start up
Alarm Silence Reset
Electronic PEEP
Tablet Based Alarm Data Log*
Tablet Based Trending Data Storage*
Patient Vital Report Generation 24 x 7 x 365
Inbuilt Air Source
Zero Risk of Cross Contamination to patient
Medical Air as Per European Standards
Flow Sensor Auto Calibration
Oxygen Sensor Auto Calibration
Blower Driven
Pressure Trigger
Automatic leakage compensation
Non-invasive Modalities
Permanent Oxygen Sensor
Automatic Altitude Compensation
Special Function
www.electraventilator.com 06
In built Blower & Permanent Sensor
USB Controller Nebuliser Compatible
A common challenge with some turbine-driven ventilators is the lack of power to deliver constant �ow and high pressure over a sustained time period. Interruptions may occur due to a need to switch devices, modes, batteries, cylinders - or even to replace a broken turbine. Electra delivers steady ICU performance and �ow with unusually high power.
Incorporated with economical solution of world class permanent mass �ow sensor and oxygen sensor with auto calibration facility.
USB controlled effective aerosol drug delivery system to patient in high �ow invasive and non invasive modalities.
Maintaining patient closed circuit drug delivery system for aersol to eliminate need of open circuit.
High Flow therapy (HFNC) comprises an active humidi�er, a single heated circuit, and a nasal cannula. It delivers adequately heated and humidi�ed medical gas at up to 70 L/min of �ow and is considered to have a number of physiological effects: reduction of anatomical dead space, PEEP effect, constant fraction of inspired oxygen, and good humidi�cation. While there have been no big randomized clinical trials, it has been gaining attention as an innovative respiratory support for critically ill patients With Airway Over Temperature Protection Feature.
www.electraventilator.com 07
HFNC
A continuous positive airway pressure (CPAP) machine is the most effective treatment for sleep apnea, a common sleep disorder in which breathing is interrupted throughout the night. Sleep apnea can decrease your quality of life and contribute to cardiovascular disease and events such as heart attack and stroke.
2. CPAP Machine
Clinical applications with Electra1. BIPAP
BiPap machine can help push air into your lungs and it can be used to provide treatment for a wide range of respiratory conditions.
• Chronic Obstructive Pulmonary Disorder (COPD)• Obesity Hypoventilation Syndrome (OHS)• Obstructive Sleep Apnea• Central Sleep Apnea
Nasal Cannula
Heated Inspiratory Circuit
Active Humidi�er
For more information, please visit onwww.electraventilator.com
079 - 29622872
414/1, Phase 2, GIDC Vatva, Ahmedabad, Gujarat - 382445