WIN2000 Air Pipe Head Flowcurves
Transcript of WIN2000 Air Pipe Head Flowcurves
![Page 1: WIN2000 Air Pipe Head Flowcurves](https://reader037.fdocuments.us/reader037/viewer/2022100315/577cc8611a28aba711a2a5c3/html5/thumbnails/1.jpg)
8/12/2019 WIN2000 Air Pipe Head Flowcurves
http://slidepdf.com/reader/full/win2000-air-pipe-head-flowcurves 1/2
Winteb v.o.f.P.O. Box 1569670AD WinschotenThe Netherlands
T l +31597412252
WIN2000 Air pipe heads
Options:1. Closing device2. Screen3. Threaded connection,
only for aluminiumpipes.
4. Powder (epoxy) coating5. Sounding pipe6. Small flange connection
C o v e r f l o w
B
A
![Page 2: WIN2000 Air Pipe Head Flowcurves](https://reader037.fdocuments.us/reader037/viewer/2022100315/577cc8611a28aba711a2a5c3/html5/thumbnails/2.jpg)
8/12/2019 WIN2000 Air Pipe Head Flowcurves
http://slidepdf.com/reader/full/win2000-air-pipe-head-flowcurves 2/2
Tel +31597412252
Flowrate in m 3/h
P r e s s u r e
d r o p
i n
k P a
P r e s s u r e
d r o p
i n
k P a
WIN2000 Air Pipe Heads: Pressure drop vs. Flow rate CharacteristicsAccording to classification Societies the air pipe head characteristic curvesare to be taken into consideration at the design stage of the ballast system.
WIN2000 type 1 without screen size DN450
P r e s s u
r e
d r o p
i n
k P a
P r e s s u r e
d r o p
i n k P a
WIN2000 type 1 without screen sizes DN50-250
WIN2000 type 1 with screen mesh18 sizes DN50-250WIN2000 type 1-B with screen mesh18 sizes DN50-125
WIN2000 type 1 without screen sizes DN300-400WIN2000 type 1 with screen mesh18 sizes DN300-400WIN2000 type 1 with screen mesh30 sizes DN300-400
Flowrate in m3 h