Webinar on Selection of Right Solar Equipment
-
Upload
ezysolare-gosolar -
Category
Environment
-
view
295 -
download
0
Transcript of Webinar on Selection of Right Solar Equipment
![Page 1: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/1.jpg)
Order anything solar at:
solarkart.ezysolare.com
Live Webinar on Selection of Right Solar Equipment
While you wait for the webinar to start, we request you to please
explore the Online Solar Cost & BoM Calculator by ezysolare.
Link available on ezysolare.com/blog
ONLINE SOLAR COST & BoM CALCULATOR
![Page 2: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/2.jpg)
Your Host
HOSTS
Puneet Singh Jaggi Shivya Singhal
Director, ezysolare COO, ezysolare
[email protected] [email protected]
+91 9998025820 +91 9379703846
![Page 3: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/3.jpg)
Questions
You can raise a hand!
![Page 4: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/4.jpg)
Problem 1: Focus only on Cost
“As I hurtled through space, one thought
kept crossing my mind - every part of this
rocket was supplied by the lowest
bidder.”
― John Glenn
![Page 5: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/5.jpg)
Problem 2: Attention only to Modules
What Should Happen!
![Page 6: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/6.jpg)
What Should Happen! What Actually Happens!
Problem 2: Attention only to Modules
![Page 7: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/7.jpg)
Module
• Select More Efficient Modules and not
necessarily the one with more cells:Power of Module = Module Area x Efficiency
• Power Tolerance: Only +ve
• Temperature Degradation
• Bypass Diodes & Bus Bars
• PID Losses
![Page 8: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/8.jpg)
Module
Makes Available: Waaree, Vikram, Navitas, Alpex, PV PowerTech etc
• Select More Efficient Modules and not
necessarily the one with more cells:Power of Module = Module Area x Efficiency
• Power Tolerance: Only +ve
• Temperature Degradation
• Bypass Diodes & Bus Bars
• PID Losses
![Page 9: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/9.jpg)
Inverter
• MPPT Voltage Range
• Maximum DC Voltage Range
• Number of MPPTs
• Number of Inputs
• Input DC Protection
• Communication
• IP Rating
• Display
![Page 10: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/10.jpg)
MPPT Voltage Range
![Page 11: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/11.jpg)
Maximum DC Voltage Range
Low
Normal
High
![Page 12: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/12.jpg)
Inverter
• MPPT Voltage Range
• Maximum DC Voltage Range
• Number of MPPTs
• Number of Inputs
• Input DC Protection
• Communication
• IP Rating
• Display
Makes Available: SMA, Zerversolar, Fronius, Kaco, Schneider, Flin etc.
![Page 13: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/13.jpg)
Cable
• Length Determines Size: • Ballpark: 100 kW required 1.5 kms
• Copper v/s Aluminium
• Sheathing & Temperature
• Inverter Warranties
![Page 14: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/14.jpg)
Cable
• Length Determines Size: • Ballpark: 100 kW required 1.5 kms
• Copper v/s Aluminium
• Sheathing & Temperature
• Inverter Warranties
Makes Available: Polycab, Seichem, Havells, KEI, Apar etc.
![Page 15: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/15.jpg)
Structures
• Optimum Tilt
• Type of Roof
• Thickness of Roof
• Wind Zone & Structure Height
![Page 16: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/16.jpg)
Earthing Strips & Rods
• Resistance should be less than 1 ohm
• Strips: Higher the thickness, lower the
resistance
• Pits: Copper v/s Iron
• System Earthing, Electrical Earthing,
Lightning Arrestor Earthing etc. to be
separate
• Redundancy
![Page 17: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/17.jpg)
Earthing Strips & Rods
• Resistance should be less than 1 ohm
• Strips: Higher the thickness, lower the
resistance
• Pits: Copper v/s Iron
• System Earthing, Electrical Earthing,
Lightning Arrestor Earthing etc. to be
separate
• Redundancy
Makes Available: SGI, JMV etc.
![Page 18: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/18.jpg)
Lightening Arrestor
• Conventional v/s ESE Type
• Height and Radius Coverage of the LA
![Page 19: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/19.jpg)
Lightening Arrestor
• Conventional v/s ESE Type
• Height and Radius Coverage of the LA
Makes Available: SGI
![Page 20: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/20.jpg)
Junction Box
• Protection Required
• Combining Required
• Number of Inputs & Outputs
![Page 21: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/21.jpg)
Junction Box
• Protection Required
• Combining Required
• Number of Inputs & Outputs
Makes Available: Hensel, Onexis etc.
![Page 22: Webinar on Selection of Right Solar Equipment](https://reader036.fdocuments.us/reader036/viewer/2022062316/5873f02a1a28abb1528b4fb1/html5/thumbnails/22.jpg)
That’s all folks…
Mohit Agarwal: +91 9925345121
Puneet Singh Jaggi: +91 9998025820
SolarKart