VRf PHV dxE H ˝, P-&) A$* C-*,˝$’ - Celsius Air Multi (VRF... · puhy / pury / pqhy / pqry vrf...

2
VRf PHV dxE Heat Pump Air Curtain Air Curtain System VRF PHV DXE - RECESSED MOdEl REfERENCE dIMENsIONs (mm) (WxdxH) sUPPlY (50Hz) HEAt OUtPUt (kW) lOAdINg (amps) VElOCItY (m/s) AIR VOlUME (m 3 /h) WEIgHt (kg) NOIsE dB(A) @ 3m MAx. MOUNtINg HEIgHt (m) OUtdOOR UNIt MOdEl VRF PHV1500R DXE HO 1650x436x296 415V*1 15.1 12.7*1 9 2600 67 58 3.5 PUMY / PUHY / PURY / PQHY / PQRY VRF PHV2000R DXE LO 2240x436x296 415V*2 16.4 15.7*2 9.5 3300 85 59 3.5 PUMY / PUHY / PURY / PQHY / PQRY Technical Information VRF PHV DXE - FREE STANDING MOdEl REfERENCE dIMENsIONs (mm) (WxdxH) sUPPlY (50Hz) HEAt OUtPUt (kW) lOAdINg (amps) VElOCItY (m/s) AIR VOlUME (m 3 /h) WEIgHt (kg) NOIsE dB(A) @ 3m MAx. MOUNtINg HEIgHt (m) OUtdOOR UNIt MOdEl VRF PHV1500R DXE LO 1650x436x296 415V*1 10.6 12.7*1 9 2500 66 58 3.5 PUMY / PUHY / PURY / PQHY / PQRY VRF PHV1000R DXE HO 1150x436x296 415V*1 9 7.8*1 9 1400 45 56 3.5 PUMY / PUHY / PURY / PQHY / PQRY VRF PHV2000R DXE HO 2240x436x296 415V*2 21.4 15.7*2 9 3130 88 59 3.5 PUHY / PURY / PQHY / PQRY VRF PHV1500 DXE HO 1746x377x255 415V*1 15.1 12.7*1 9 2600 60 58 3.75 PUMY / PUHY / PURY / PQHY / PQRY VRF PHV2000 DXE LO 2296x377x255 415V*2 16.4 15.7*2 9.5 3300 78 59 3.75 PUMY / PUHY / PURY / PQHY / PQRY VRF PHV1500 DXE LO 1746x377x255 415V*1 10.6 12.7*1 9 2500 59 58 3.75 PUMY / PUHY / PURY / PQHY / PQRY VRF PHV1000 DXE HO 1196x377x255 415V*1 9 7.8*1 9 1400 39 56 3.75 PUMY / PUHY / PURY / PQHY / PQRY VRF PHV2000 DXE HO 2296x377x255 415V*2 21.4 15.7*2 9 3130 80 59 3.75 PUHY / PURY / PQHY / PQRY Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for VRF PHV1000R DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load. Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for VRF PHV1000 DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load. In collaboration with Thermoscreens, Mitsubishi Electric have developed a range of air curtains that are able to be connected to our City Multi VRF systems, as opposed to the more traditional direct electric method associated with air curtains. Reduced CO2 emissions Reduced Running Costs Inverter technology (does not waste energy) Range of different sizes to suit every application Allows open door policy in retail outlets whilst being energy efficient Clean environment - protection from dust, fumes etc Comfortable climate for customers Easy to install and maintain Heat recovery possible, optimising energy use

Transcript of VRf PHV dxE H ˝, P-&) A$* C-*,˝$’ - Celsius Air Multi (VRF... · puhy / pury / pqhy / pqry vrf...

Page 1: VRf PHV dxE H ˝, P-&) A$* C-*,˝$’ - Celsius Air Multi (VRF... · puhy / pury / pqhy / pqry vrf p h1 5 0 dxe o 1 74 6 a3 25 415v *1 15 . 12 .7*1 9 2 6 0 6 0 58 3.75 ... h0,= ;0.9?0;b

VRf PHV dxE Heat Pump Air CurtainAir Curtain System

VRF PHV DXE - RECESSEDMOdEl REfERENCE

dIMENsIONs (mm) (WxdxH)

sUPPlY (50Hz)

HEAt OUtPUt (kW)

lOAdINg (amps)

VElOCItY (m/s)

AIR VOlUME (m3/h)

WEIgHt (kg)

NOIsE dB(A) @ 3m

MAx. MOUNtINg HEIgHt (m)

OUtdOOR UNIt MOdEl

VRF PHV1500R DXE HO

1650x436x296

415V*1

15.1

12.7*1

9

2600

67

58

3.5

PUMY / PUHY / PURY / PQHY / PQRY

VRF PHV2000R DXE LO

2240x436x296

415V*2

16.4

15.7*2

9.5

3300

85

59

3.5

PUMY / PUHY / PURY / PQHY / PQRY

Technical Information

VRF PHV DXE - FREE STANDINGMOdEl REfERENCE

dIMENsIONs (mm) (WxdxH)

sUPPlY (50Hz)

HEAt OUtPUt (kW)

lOAdINg (amps)

VElOCItY (m/s)

AIR VOlUME (m3/h)

WEIgHt (kg)

NOIsE dB(A) @ 3m

MAx. MOUNtINg HEIgHt (m)

OUtdOOR UNIt MOdEl

VRF PHV1500R DXE LO

1650x436x296

415V*1

10.6

12.7*1

9

2500

66

58

3.5

PUMY / PUHY / PURY / PQHY / PQRY

VRF PHV1000R DXE HO

1150x436x296

415V*1

9

7.8*1

9

1400

45

56

3.5

PUMY / PUHY / PURY / PQHY / PQRY

VRF PHV2000R DXE HO

2240x436x296

415V*2

21.4

15.7*2

9

3130

88

59

3.5

PUHY / PURY / PQHY / PQRY

VRF PHV1500 DXE HO

1746x377x255

415V*1

15.1

12.7*1

9

2600

60

58

3.75

PUMY / PUHY / PURY / PQHY / PQRY

VRF PHV2000 DXE LO

2296x377x255

415V*2

16.4

15.7*2

9.5

3300

78

59

3.75

PUMY / PUHY / PURY / PQHY / PQRY

VRF PHV1500 DXE LO

1746x377x255

415V*1

10.6

12.7*1

9

2500

59

58

3.75

PUMY / PUHY / PURY / PQHY / PQRY

VRF PHV1000 DXE HO

1196x377x255

415V*1

9

7.8*1

9

1400

39

56

3.75

PUMY / PUHY / PURY / PQHY / PQRY

VRF PHV2000 DXE HO

2296x377x255

415V*2

21.4

15.7*2

9

3130

80

59

3.75

PUHY / PURY / PQHY / PQRY

Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for VRF PHV1000R DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for VRF PHV1000 DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

In collaboration with Thermoscreens, Mitsubishi Electric have developed a range of air curtains that are able to beconnected to our City Multi VRF systems, as opposed to the more traditional direct electric method associatedwith air curtains.

� Reduced CO2 emissions

� Reduced Running Costs

� Inverter technology (does not waste energy)

� Range of different sizes to suit every application

� Allows open door policy in retail outletswhilst being energy efficient

� Clean environment - protection from dust, fumes etc

� Comfortable climate for customers

� Easy to install and maintain

� Heat recovery possible, optimising energy use

Page 2: VRf PHV dxE H ˝, P-&) A$* C-*,˝$’ - Celsius Air Multi (VRF... · puhy / pury / pqhy / pqry vrf p h1 5 0 dxe o 1 74 6 a3 25 415v *1 15 . 12 .7*1 9 2 6 0 6 0 58 3.75 ... h0,= ;0.9?0;b

Cit

y M

ult

iR

ange

VR

f PH

V d

xE

Air C

urt

ain

AIR CURTAIN VRf PHV1000/1500/2000R dxE

Dimensions

AIR CURTAIN VRf PHV1000/1500/2000 dxE

Rear View >

Upper View >

side View >

Rear View >

Upper View >

side View >