ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels...

27
Certificate: EN 303-5:2012 class 5 EN 14785 G A R A N Z I A S U L C O R P O C A L D A I A 5 ANNI ViVi UNGARO Catalogue 2016 PELLET BOILERS AND BOILER-STOVES

Transcript of ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels...

Page 1: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Certificate: EN 303-5:2012 class 5 EN 14785

GA

RANZIA SUL CORPO CALDAIA 5

ANNI

ViVi UNGA

RO

Catalogue 2016

PELLET BOILERS AND BOILER-STOVES

Page 2: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Ungaro is a manufacturing company that provides innovative pellet heating products for residential use. After have been studied the traditional biomass heating systems, Ungaro has changed its logic and gone over its limits. Ungaro was the first manufacturer to introduce a super fast copper heat exchanger, now this unique technology is protected by patent.Quality 100% made in Italy, continuous investments in research and development, boilers and stoves certificated efficiency, after sales installation assistance – to become an Ungaro’s partner is a valuable choice. QUALITY 100% MADE IN ITALY

Ungaro manages all the stages of production chain at its own factory in Italy according to the most stringent international stan-dards ISO9001 (Quality management system) and ISO14001 (Environmental management system). The choice guarantees our constant attention to the products quality, continuous evolution of the product line – one of the biggest in the pellet heating industry and the extreme flexibility in reaction to the new market requirements.

UNGARO: THE NEW PELLET HEATING CULTURE

RESEARCH AND DEVELOPMENT

Ungaro’s solutions and the patents registered over the years are the result of the company’s considerable in-vestments, intense work of our in-house Research and Development and the studies conducted in collaboration with university research centres.

CERTIFICATED PRODUCTS EFFICIENCY

Ungaro’s heat generators are made in line with the exi-sting European legislation. Their energy perfomance is certificated by the most important International institutes.

TECHNICAL SERVICE GUARANTEED

Ungaro is always close to its partners. Our exceptional Service Department consists of highly qualified techni-cians ready to assist in any installation and to provide technical training.

SUCCESSFUL PARTNERSHIP

The best operators in the biomass heating sector in Italy and abroad have already choosen Ungaro as a reliable partner. Ungaro provides advanced technology and custo-mised solutions for every expert in pellet heating.

Page 3: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

UNGARO BOILER TECHNOLOGY

With the new highly efficient, self-cleaning boilers Ungaro, pellet heating becomes extremely comfortable.

There are seven different versions: automated maintenance, extended working autonomy thanks to a large pellet hopper or feeding from an outdoor storage silo. We produce the boilers which will satisfy your needs in the best way. in order to supply the customer with the more balanced technical solution.

2

1

3

4

5

6

7

Page 4: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

7 AUTOMATIC ASH REMOVAL

Ash is compacted in an easy to handle container on wheels

1 PNEUMATIC LOADING

Allows to convey pellet to the boiler’s hopper from an outdoor storage

3 AUTOMATIC TUBE BUNDLE CLEANING

To keep constantly efficient heat exchange

5 ASH COMPACTOR

Automated units for compacting the combustion ash

4 AUTOMATIC BRAZIER CLEANER

Automatic cleaning at every ignition then regu-larly during the operation

6 ASH REDUCER

The units keep fine ash from flying out in the exhaust pipe and compact it in a special box

2 FAST HEAT EXCHANGER

Copper tube bundle with water efficiency over 90%

Comply with: EN 303-5:2012 (class 5)EN 14785

GA

RANZIA SUL CORPO CALDAIA 5

ANNI

Page 5: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Rapid heat exchanger is the recent evolution of Ungaro’s concept. Copper tube bundle with heat transfer to water over 90%. Well insulated to minimize heat loss.

Automatic tube bundle cleaning at every boiler ignition to keep constantly efficient heat exchange.

Ash compactors Two separate automated units for compacting ashes falling from burn chamber and those compacted in the ash trap. They provide long boiler’s autonomy without maintenance.

Automatic Brazier CleanerAutomatic cleaner activates at every ignition and regularly during the operation.

Ash Reducer placed at the exhaust pipe, with the special deflec-tors catches fine ash. Easy to inspect.

UNIQUE WITH FAST THERMAL EXCHANGE

ASIAABC AC

KLIMAWORKS

CCASH COMPACTOR

KlimaWorks is the practical Ungaro system which re-gulates the water temperature in a boiler according to the outside temperature. Therefore it remarkably raises the comfort in heated rooms and reduces pellet consumption and emissions up to 30%.

Automatic System Inlet Air is the exclusive Ugaro system for automatic regulation of the combustion air, it adapts boiler’s operation to the quantity of pellet in the burner and the depressure in the flue.

EXCLUSIVE TECHNOLOGY FOR BETTER EFFICIENCY:

Exclusive patented Ungaro copper tube bundle is a true boiler’s heart! It guarantees high power output, heating a very small volume of water in the boiler. Good thermal conductivity of copper plus Ungaro technology permit to transport immediately the produced heat to the wet radiator system.

That’s why Ungaro boiler is compact, has energy efficiency over 90% and low pellet consumption.

Thermal Water exchanger

Heat input

Primary air inlet

Smoke Exhaust

WATER EFFICIENCY

AEC

Page 6: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

BULK PELLET STORAGE

Pneumatic pellet loading unit a powerful engine conveys pellet from an outside storage to the boiler’s hopper.

Bulk-storage container One ton of pellet can be loaded in a solid steel container.

Configuration CTU A6

Pneumatic loading Possibility to connect a pneumatic loading unit from a storage placed at up to 5 meters of level difference. The boiler meets the needs of the modern houses with a room for pellet storage.

Pellet storage in other silos from 2 to 10 tons

1.000 Kg

1.000 Kg

Page 7: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Heating system schemes

Configuration 0 - Boiler directly connected to wet radiator system

Configuration 2 - Boiler connected to a DHW cylinder and wet radiator system

n° Component1 Boiler

2 Circulation pump

3 External temperature sensor

4 Collector

5 Radiators

1

2

3

4

5

n° Component1 Boiler

2 Circulation pump

3 External temperature sensor

4 Switchover valve

5 DHW cylinder

6 DHW cylinder probe

7 Domestic hot water

8 Radiators

1

2

3

4

56

7

8

Indicative, not binding schemes. No Anti condensation systems required* Thanks to the high efficiency of the rapid heat exchanger, Ungaro products do not require additional and costly anti condensation units.*Respecting installation conditions and use specified by the manufacturer.

Page 8: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Configuration 4 - Boiler connected to a buffer tank with a single sensor

Configuration 6 - Boiler connected to a buffer tank with a double sensor

n° Component1 Boiler

2 Circulation pump

3 External temperature sensor

4 Buffer tank

5 Buffer tank temperature sensor

n° Component1 Boiler

2 Circulation pump

3 External temperature sensor

4 Switchover valve

5 Stratification buffer tank

6 Upper t° sensor

7 Lower t° sensor

8 Collector

9 External pump

10 Plate heat exchanger

11 Domestic hot water

12 Solar panel

13 Radiators

14 Underfloor heating

1

2

3

4

5

1

2

3

4

4

5

6

78

9

9

9

10

11

1213

14

Heating system schemes

Page 9: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Model Code Power Price Standard equipment

CTU M

CTUM18 5-18 kW € 4.400,00• Copper heat exchanger 90• Connectable to KlimaWorks probe• Automatic air inlet regulation ASIA• Ash Reducer AC

CTUM24 6-24 kW € 4.600,00

CTUM34 9-34 kW € 5.400,00

CTU A1

CTUA118 5-18 kW € 5.200,00 • Copper heat exchanger 90• Connectable to KlimaWorks probe• Automatic air inlet regulation ASIA• Ash Reducer AC• Automatic Brazier Cleaner ABC

CTUA124 6-24 kW € 5.400,00

CTUA134 9-34 kW € 6.200,00

CTU A2

CTUA218 5-18 kW € 5.800,00 • Copper heat exchanger 90• Connectable to KlimaWorks probe• Automatic air inlet regulation ASIA• Ash Reducer AC• Automatic Brazier Cleaner ABC• Automatic exchanger cleaner AEC

CTUA224 6-24 kW € 6.000,00

CTUA234 9-34 kW € 6.800,00

CTU A3

CTUA318 5-18 kW € 6.400,00 • Copper heat exchanger 90• Connectable to KlimaWorks probe• Automatic air inlet regulation ASIA• Ash Reducer AC• Automatic Brazier Cleaner ABC• Automatic exchanger cleaner AEC• Ash Compactor CC

CTUA324 6-24 kW € 6.600,00

CTUA334 9-34 kW € 7.400,00

CTU cpc from 5 to 34 kW

Pellet floor–standing boiler with automatic com-bustion modulation for central water heating. Control software for the most common heating schemes. The boiler is equipped with all neces-sary components: circulation pump, expansion vessel, thermic, electric and hydraulic securities, exhaust fan. It’s possible to connect a room ther-mostat. Easy maintenance with automatedcleaning systems. Extended operation autonomy when connected to an external bulk-storage container and a powerful aspirator.

ASIA

ABC

ACWATER

EFFICIENCY

KLIMAWORKS

AEC CCASH COMPACTOR

XCOPPER®

CPC Ungaro boiler body meets the requirements of class 5 EN 303-5 and EN 14785.

Standard for all product line

Standard for the particular modelGA

RANZIA SUL CORPO CALDAIA 5

ANNI

Page 10: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Specifications 5-18 6-24 9-34

Heat inputMax kW 18,2 24,0 33,4

Min kW 5,3 7,1 9,9

Water efficiencyMax % 90,0 90,0 90,0

Min % 90,0 91,6 90,3

EfficiencyMax % 92,2 92,2 92,1

Min % 96,6 95,8 95,2

Water heat outputMax kW 16,4 21,6 30,3

Min kW 4,8 6,2 9,0

Hourly pellet consumptionMax kg 3,8 5,6 7,0

Min kg 1,1 1,6 2,0

Hopper capacity kg 45 45 54

Heating area m2 120 160 270

Smoke exhaust Ø mm 100 100 100

DraftMax Pa 12,0 12,0 12,0

Min Pa 11,0 11,0 11,0

Water circulator prevalence m 5 6 6

Pressure on cold working mode bar 0,8/1,2 0,8/1,2 0,8/1,2

Expansion vessel l 6 8 8

Domestic hot water supply (optional) l/min 10 12 14

Energy consumption W 150 165 165

Height A mm 1500 1500 1580

Width B mm 660 660 660

Depth C mm 700 700 715

Smoke outlet Ø100

System entrance 3/4”Hot sanitary 1/2” Cold sanitary 1/2”

Air

inle

t Ø

60

System return 3/4”

A

C

B

Alte

rnat

ive

Smok

e ou

tlet

65 115 65

Top view

Front view

Back view

Page 11: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

CTU box cpc from 5 to 50 kW

Pellet floor–standing boiler with automatic com-bustion modulation for central water heating. Control software for the most common heating schemes. The boiler is equipped with all neces-sary components: circulation pump, expansion vessel, thermic, electric and hydraulic securities, exhaust fan. It’s possible to connect a room ther-mostat. Easy maintenance with automated cle-aning systems. Extended operation autonomy thanks to the integrated pellet box.

Model Code Power Price Standard equipment

CTU A4

CTUA418 5-18 kW € 7.345,00 • Copper heat exchanger 90

• Connectable to KlimaWorks probe

• Automatic air inlet regulation ASIA

• Ash Reducer AC

• Automatic Brazier Cleaner ABC

• Automatic exchanger cleaner AEC

• Integrated pellet box

CTUA424 6-24 kW € 7.545,00

CTUA434 9-34 kW € 8.345,00

CTUA450 50 kW € 9.045,00

CTU A5

CTUA518 5-18 kW € 7.945,00• Copper heat exchanger 90

• Connectable to KlimaWorks probe

• Automatic air inlet regulation ASIA

• Ash Reducer AC

• Automatic Brazier Cleaner ABC

• Automatic exchanger cleaner AEC

• Integrated pellet box

• Ash Compactor CC

CTUA524 6-24 kW € 8.845,00

CTUA534 9-34 kW € 8.945,00

CTUA550 50 kW € 9.645,00

Standard for all product line

Standard for the model A5

GA

RANZIA SUL CORPO CALDAIA 5

ANNI

ASIA

ABC

ACWATER

EFFICIENCY

KLIMAWORKS

AEC

CCASH COMPACTOR

XCOPPER®

CPC Ungaro boiler body meets the requirements of class 5 EN 303-5 and EN 14785.

Page 12: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Specifications 5-18 6-24 9-34 50A 50B

Heat inputMax kW 18,2 24,0 33,4 44,7 48,1

Min kW 5,3 7,1 9,9 11,7 11,7

Water efficiencyMax % 90,0 90,0 90,0 89,5 89,5

Min % 90,0 91,6 90,3 93,5 93,5

EfficiencyMax % 92,2 92,2 92,1 94,2 92,0

Min % 96,6 95,8 95,2 95,0 95,0

Water heat outputMax kW 16,4 21,6 30,3 40,0 43,1

Min kW 4,8 6,2 9,0 11,0 11,0

Hourly pellet consumptionMax kg 3,8 5,6 7,0 9,4 10,1

Min kg 1,1 1,6 2,0 2,5 2,5

Hopper capacity kg 275 275 284 272 272

Heating area m2 120 160 270 400 400

Smoke exhaust Ø mm 100 100 100 120 120

DraftMax Pa 12,0 12,0 12,0 12,0 12,0

Min Pa 11,0 11,0 11,0 11,0 11,0

Primary air inlet Ø mm 60 60 60 75 75

Water circulator prevalence m 5 6 6 6 6

Pressure on cold working mode bar 0,8/1,2 0,8/1,2 0,8/1,2 0,8/1,2 0,8/1,2

Expansion vessel l 6 8 8 8 8

Domestic hot water supply (optional) l/min 10 12 14 14 14

Energy consumption W 150 165 165 165 165

Height A mm 1500 1500 1580 1580 1580

Width B mm 1350 1350 1350 1350 1350

Depth C mm 700 700 715 715 715

Smoke outlet Ø100/120

A

C

BTop view

Front view

Page 13: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

CTU cpc from 5 to 50 kW

Pellet floor–standing boiler with automatic com-bustion modulation for central water heating. Control software for the most common heating schemes. The boiler is equipped with all neces-sary components: circulation pump, expansion vessel, thermic, electric and hydraulic securities, exhaust fan. It’s possible to connect a room ther-mostat. Easy maintenance with automated cle-aning systems. Extended operation autonomy when connected to an external bulk-storage con-tainer and a powerful aspirator.

Model Code Power Price Standard equipment

CTU A6

CTUA618 5-18 kW € 7.945,00• Copper heat exchanger 90

• Connectable to KlimaWorks probe

• Automatic air inlet regulation ASIA

• Ash Reducer AC

• Automatic Brazier Cleaner ABC

• Automatic exchanger cleaner AEC

• Ash Compactor CC

• Pneumatic pellet loading PCP

• External container for bulk storage

CTUA624 6-24 kW € 8.545,00

CTUA634 9-34 kW € 8.945,00

CTUA650 50 kW € 9.645,00

PVC tubes per meter € 15,00

One ton of pellet loaded in a solid metal container

Container specifications

GA

RANZIA SUL CORPO CALDAIA 5

ANNI

Standard for all product line

ASIA

ABC

ACWATER

EFFICIENCY

KLIMAWORKS

AEC CCASH COMPACTOR

XCOPPER®

CPC Ungaro boiler body meets the requirements of class 5 EN 303-5 and EN 14785.

1100

1500

1100

Aspiration Ø50Compression Ø50

top view side view front view

Page 14: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Specifications 5-18 6-24 9-34 50A 50B

Heat inputMax kW 18,2 24,0 33,4 44,7 48,1

Min kW 5,3 7,1 9,9 11,7 11,7

Water efficiencyMax % 90,0 90,0 90,0 89,5 89,5

Min % 90,0 91,6 90,3 93,5 93,5

EfficiencyMax % 92,2 92,2 92,1 94,2 92,0

Min % 96,6 95,8 95,2 95,0 95,0

Water heat outputMax kW 16,4 21,6 30,3 40,0 43,1

Min kW 4,8 6,2 9,0 11,0 11,0

Hourly pellet consumptionMax kg 3,8 5,6 7,0 9,4 10,1

Min kg 1,1 1,6 2,0 2,5 2,5

Hopper capacity kg 45 45 54 42 42

Container capacity kg 1000 1000 1000 1000 1000

Heating area m2 120 160 270 400 400

Smoke exhaust Ø mm 100 100 100 120 120

DraftMax Pa 12,0 12,0 12,0 12,0 12,0

Min Pa 11,0 11,0 11,0 11,0 11,0

Primary air inlet Ø mm 60 60 60 75 75

Water circulator prevalence m 5 6 6 6 6

Pressure on cold working mode bar 0,8/1,2 0,8/1,2 0,8/1,2 0,8/1,2 0,8/1,2

Expansion vessel l 6 8 8 8 8

Domestic hot water supply (optional) l/min 10 12 14 14 14

Energy consumption W 150 165 165 165 165

Height A mm 1820 1820 1900 1900 1900

Width B mm 900 900 900 900 900

Depth C mm 700 700 715 715 715

A

B

C

65 115 65

System entrance 3/4” System return 3/4”

Smoke Exhaust Ø 100/120Aspiration Ø50

Compression Ø 50

Air

inle

t Ø

60/

75

A

ltern

ativ

e Sm

oke

Exha

ust

Hot sanitary 1/2” Cold sanitary 1/2”

top view

front view side view

back view

Page 15: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Model Code Power Price Standard equipment

CTU Sub M

CTUM18SUB 5-18 kW € 5.200,00 • Copper heat exchanger 90• Connectable to KlimaWorks probe• Automatic air inlet regulation ASIA• Ash Reducer AC• Ideal for an outside installation

CTUM24SUB 6-24 kW € 5.400,00

CTUM34SUB 9-34 kW € 6.200,00

CTU Sub A1

CTUA118SUB 5-18 kW € 6.000,00 • Copper heat exchanger 90• Connectable to KlimaWorks probe• Automatic air inlet regulation ASIA• Ash Reducer AC• Automatic Brazier Cleaner ABC• Ideal for an outside installation

CTUA124SUB 6-24 kW € 6.200,00

CTUA134SUB 9-34 kW € 7.000,00

CTU Sub A2

CTUA218SUB 5-18 kW € 6.800,00 • Copper heat exchanger 90• Connectable to KlimaWorks probe• Automatic air inlet regulation ASIA• Ash Reducer AC• Automatic Brazier Cleaner ABC• Automatic exchanger cleaner AEC• Ideal for an outside installation

CTUA224SUB 6-24 kW € 7.000,00

CTUA234SUB 9-34 kW € 7.800,00

CTU Sub A3

CTUA318SUB 5-18 kW € 7.600,00• Copper heat exchanger 90• Connectable to KlimaWorks probe• Automatic air inlet regulation ASIA• Ash Reducer AC• Automatic Brazier Cleaner ABC• Automatic exchanger cleaner AEC• Ash Compactor CC• Ideal for an outside installation

CTUA324SUB 6-24 kW € 7.800,00

CTUA334SUB 9-34 kW € 8.600,00

CTU Sub cpc from 5 to 34 kW

The new product can be installed outside the house. The boiler is completely waterproof, its pellet hopper is protected from humidity. The CTU Sub is a clever solution for assured comfort in your home, it saves living space and reduces installation costs. Control software and hydraulic components are included. A large range of auto-matic units for routine maintenance.

Standard for all product line

Standard for the particular model

GA

RANZIA SUL CORPO CALDAIA 5

ANNI

NEW 2016

ASIA

ABC

ACWATER

EFFICIENCY

KLIMAWORKS

AEC CCASH COMPACTOR

XCOPPER®

CPC Ungaro boiler body meets the requirements of class 5 EN 303-5 and EN 14785.

Page 16: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Specifications 5-18 6-24 9-34

Heat inputMax kW 18,2 24,0 33,4

Min kW 5,3 7,1 9,9

Water efficiencyMax % 90,0 90,0 90,0

Min % 90,0 91,6 90,3

EfficiencyMax % 92,2 92,2 92,1

Min % 96,6 95,8 95,2

Water heat outputMax kW 16,4 21,6 30,3

Min kW 4,8 6,2 9,0

Hourly pellet consumptionMax kg 3,8 5,6 7,0

Min kg 1,1 1,6 2,0

Hopper capacity kg ≈ 100 ≈ 100 ≈ 100

Heating area m2 120 160 270

Smoke exhaust Ø mm 100 100 100

DraftMax Pa 12,0 12,0 12,0

Min Pa 11,0 11,0 11,0

Primary air inlet Ø mm 60 60 60

Water circulator prevalence m 5 6 6

Pressure on cold working mode bar 0,8/1,2 0,8/1,2 0,8/1,2

Expansion vessel l 6 8 8

Domestic hot water supply (optional) l/min 10 12 14

Energy consumption W 150 165 165

Height A mm 1550 1550 1550

Width B mm 1020 1020 1020

Depth C mm 650 650 650

10201550

650

Domestic hot water 1/2”

Smok

e Ex

haus

t Ø

100

System entrance 3/4”

Top view

Front view

Back view

Side view

Page 17: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Specifications and prices

Nominal power W 1500

Power supply V 230

Nominal frequency Hz 50

Max depressure Mbar 220

Internal hopper l 6

IN/OUT tubes Ø mm 50

Aspirator € 1.200,00

Pellet silo € 400,00

Aspirator adapter € 200,00

Sensor extractor € 150,00

PVC cable 20 m € 300,00

Components Pellet silo Kg. 1.000 (optional) - Dim. 110x110x155 cm

Control panel with back lit LCD-display

Universal adapter (optional) - Dim. 32x32x17 cm

Polyester filter cartridge

Loading sensor

Power cable with Schuko plug, 1.5 mt

Aspirator TaurusIdeal for low-cost and easy maintained automatic pellet loading. Taurus aspira-tor transports pellet to the boiler from an outside silo placed at up to 10 m with 5 m of gap.

- Ideal to convey pellets to boilers and thermo stoves- Automatic operation- Fast installation - Easy maintenance

Dimensions

Sample installation

External pellet storageOne ton of pellet can be stored in a solid steel container.

Pneumatic loading unitA powerful motor helps to convey pellet from an outside silo to boiler hopper. Can be installed on any type of silo

Universal adapter

320

Ø50

300 320

Ø50

Aspiration Ø50 Compression Ø50

top view front view back view

Page 18: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Silo from 2,8 to 5 tonsA smart solution to store a big volume of pellets; it is conveyed to the boiler from an external silo by various extractive units. Height-adjustable construction and cone in galvanised steel, this silo is made of high-strength static-resistant fabric. Fast assembly click system.

Auger extractor

Auger extractor, motor included; overload pro-tection, pellet conveying unit with tube connec-tors; auger with pad and box, can transport pel-lets up to 25 meters.

Sensor extractor

Sensor extractor with level sensor and cover; diameter of tube connectors 50 mm, can tran-sport pellets up to 12 meters.

Dimensions

Price

Silo from 2,8 to 5 tons € 2.505,60

Auger extractor transports up to 25 m € 936,90

Sensor extractor transports up to 12 m € 402,30

Two connections (Ø 4”) to fill and to convey pellet € 298,35

Filling system

Two connections (Ø 4”) to fill and to suck up pellet; joints Storz-A, covering, clamps and bo-arding for tubes extension.

A

B

C C

86013

60

500

230

1800

÷ 2

500

2100

2100

A

B

C

Filling system lock

Control gate

Extraction system

Page 19: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Blackcod. NE

Bordeauxcod. BX

Whitecod. BI

Mokacod. MK

Model Power Price Code Standard equipment

SMART Wood M

5-18 kW € 4.650,00 MFSW18 • Patented copper tube bundle

• Heat exchanger 90

• Connectable to KlimaWorks probe

• Automatic air inlet regulation ASIA

• Ash Reducer AC

6-24 kW € 4.850,00 MFSW24

9-34 kW € 5.300,00 MFSW34

SMART Wood A1

5-18 kW € 5.245,00 MFSW18A1 • Patented copper tube bundle

• Heat exchanger 90

• Connectable to KlimaWorks probe

• Automatic air inlet regulation ASIA

• Ash Reducer AC

• Automatic Brazier Cleaner ABC

6-24 kW € 5.450,00 MFSW24A1

9-34 kW € 5.900,00 MFSW34A1

SMART cpc from 5 to 34 kW

Hydro pellet boiler with automatic combustion modulation for central heating, can be easily con-nected to any existing plumbing system. Paten-ted heat exchanger cleaning, programmable igni-tions and shutdowns, kit for continuous domestic hot water supply (optional). MDF finish available in 4 colours, external glass door.

Standard for all product line

Standard for the model A1

GA

RANZIA SUL CORPO CALDAIA 5

ANNI

ASIA

ABC

ACWATER

EFFICIENCY

KLIMAWORKS

XCOPPER®

CPC Ungaro boiler body meets the requirements of class 5 EN 303-5 and EN 14785.

Page 20: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Specifications 5-18 6-24 9-34

Heat inputMax kW 18,2 24,0 33,4

Min kW 5,3 7,1 9,9

Nominal heatMax kW 16,5 22,0 31,0

Min kW 5,0 6,7 9,5

Air heat outputMax kW 0,5 0,7 1,0

Min kW 0,5 0,5 0,5

EfficiencyMax % 90,8 91,5 92,7

Min % 93,9 94,8 96,2

Water heat outputMax kW 16,0 21,3 30,0

Min kW 4,5 6,2 9,0

Hourly pellet consumptionMax kg 3,8 5,6 7,0

Min kg 1,1 1,6 2,0

Hopper capacity kg 32 32 40

Heating area m2 120,0 160,0 270,0

Smoke exhaust Ø mm 100,0 100,0 100,0

DraftMax Pa 12,0 12,0 12,0

Min Pa 11,0 11,0 11,0

Primary air inlet Ø mm 60,0 60,0 60,0

Water circulator prevalence m 5,0 6,0 6,0

Pressure on cold working mode bar 0,8/1,2 0,8/1,2 0,8/1,2

Expansion vessel l 6,0 6,0 8,0

Domestic hot water supply (optional) lt/min 10,0 12,0 14,0

Power supply 220 V 50 Hz

220 V 50 Hz

220 V 50 Hz

Energy consumption W 150,0 165,0 165,0

Height A mm 1290 1290 1387

Width B mm 610 610 665

Depth C mm 620 620 621

A

C

BSm

oke

Exha

ust

Ø10

0

Air

inle

t Ø 6

0A

lter

nativ

e Sm

oke

Exha

ust

System entrance 3/4”Hot sanitary 1/2” Cold sanitary 1/2”

System return 3/4”

top view

front view side view

back view

Page 21: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Blackcod. NE

Bordeauxcod. BX

Cherrycod. CI

Walnutcod. NO

Ivorycod. AV

Model Power Price Code Standard equipment

FREE Style M

5-18 kW € 4.550,00 MFA18 • Patented copper tube bundle

• Heat exchanger 90

• Connectable to KlimaWorks probe

• Automatic air inlet regulation ASIA

• Ash Reducer AC

6-24 kW € 4.750,00 MFA24

9-34 kW € 5.200,00 MFA34

FREE Style A1

5-18 kW € 5.150,00 MFA18A1 • Patented copper tube bundle

• Heat exchanger 90

• Connectable to KlimaWorks probe

• Automatic air inlet regulation ASIA

• Ash Reducer AC

• Automatic Brazier Cleaner ABC

6-24 kW € 5.350,00 MFA24A1

9-34 kW € 5.800,00 MFA34A1

FREEstylecpc

from 5 to 34 kW

Hydro pellet boiler-stove with automatic combustion modulation for central heating, can be easily connected to any existing plumbing system. Patented heat exchanger cleaning, programmable ignitions and shutdowns, kit for continuous domestic hot water supply (optional). Aluminium finish available in 5 colours, external glass door.

GA

RANZIA SUL CORPO CALDAIA 5

ANNI

Standard for all product line

Standard for the model A1

ASIA

ABC

ACWATER

EFFICIENCY

KLIMAWORKS

XCOPPER®

CPC Ungaro boiler body meets the requirements of class 5 EN 303-5 and EN 14785.

Page 22: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Specifications 5-18 6-24 9-34

Heat inputMax kW 18,2 24,0 33,4

Min kW 5,3 7,1 9,9

Nominal heatMax kW 16,5 22,0 31,0

Min kW 5,0 6,7 9,5

Air heat outputMax kW 0,5 0,7 1,0

Min kW 0,5 0,5 0,5

EfficiencyMax % 90,8 91,5 92,7

Min % 93,9 94,8 96,2

Water heat outputMax kW 16,0 21,3 30,0

Min kW 4,5 6,2 9,0

Hourly pellet consumptionMax kg 3,8 5,6 7,0

Min kg 1,1 1,6 2,0

Hopper capacity kg 32 32 40

Heating area m2 120,0 160,0 270,0

Smoke exhaust Ø mm 100,0 100,0 100,0

DraftMax Pa 12,0 12,0 12,0

Min Pa 11,0 11,0 11,0

Primary air inlet Ø mm 60,0 60,0 60,0

Water circulator prevalence m 5,0 6,0 6,0

Pressure on cold working mode bar 0,8/1,2 0,8/1,2 0,8/1,2

Expansion vessel l 6,0 6,0 8,0

Domestic hot water supply (optional) lt/min 10,0 12,0 14,0

Power supply 220 V 50 Hz

220 V 50 Hz

220 V 50 Hz

Energy consumption W 150,0 165,0 165,0

Height A mm 1265 1265 1365

Width B mm 670 670 725

Depth C mm 620 620 620

A

C

B

Smok

e Ex

haus

t Ø

100

Air

inle

t Ø 6

0A

lter

nativ

e Sm

oke

Exha

ust

System entrance 3/4”Hot sanitary 1/2” Cold sanitary 1/2”

System return 3/4”

top view

front view side view

back view

Page 23: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Blackcod. NE

Bordeauxcod. BX

Whitecod. BI

Model Power Price Code Standard equipment

FIT I M

5-18 kW € 5.150,00 FITI18 • Patented copper tube bundle

• Heat exchanger 90

• Connectable to KlimaWorks probe

• Automatic air inlet regulation ASIA

• Ash Reducer AC

6-24 kW € 5.350,00 FITI24

9-34 kW € 5.800,00 FITI34

FIT I A1

5-18 kW € 5.750,00 FITI18A1 • Patented copper tube bundle

• Heat exchanger 90

• Connectable to KlimaWorks probe

• Automatic air inlet regulation ASIA

• Ash Reducer AC

• Automatic Brazier Cleaner ABC

6-24 kW € 5.950,00 FITI24A1

9-34 kW € 6.400,00 FITI34A1

FIT i cpc from 5 to 34 kW

Hydro pellet boiler-stove with automatic combustion modulation for central heating, can be easily connected to any existing plumbing system. Patented heat exchanger cleaning, programmable ignitions and shutdowns, kit for continuous domestic hot water supply (optional). Finish available in 3 colours, external glass door.

GA

RANZIA SUL CORPO CALDAIA 5

ANNI

Standard for all product line

Standard for the model A1

ASIA

ABC

ACWATER

EFFICIENCY

KLIMAWORKS

XCOPPER®

CPC Ungaro boiler body meets the requirements of class 5 EN 303-5 and EN 14785.

Page 24: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Specifications 5-18 6-24 9-34

Heat inputMax kW 18,2 24,0 33,4

Min kW 5,3 7,1 9,9

Nominal heatMax kW 16,5 22,0 31,0

Min kW 5,0 6,7 9,5

Air heat outputMax kW 0,5 0,7 1,0

Min kW 0,5 0,5 0,5

EfficiencyMax % 90,8 91,5 92,7

Min % 93,9 94,8 96,2

Water heat outputMax kW 16,0 21,3 30,0

Min kW 4,5 6,2 9,0

Hourly pellet consumptionMax kg 3,8 5,6 7,0

Min kg 1,1 1,6 2,0

Hopper capacity kg 32 32 40

Heating area m2 120,0 160,0 270,0

Smoke exhaust Ø mm 100,0 100,0 100,0

DraftMax Pa 12,0 12,0 12,0

Min Pa 11,0 11,0 11,0

Primary air inlet Ø mm 60,0 60,0 60,0

Water circulator prevalence m 5,0 6,0 6,0

Pressure on cold working mode bar 0,8/1,2 0,8/1,2 0,8/1,2

Expansion vessel l 6,0 6,0 8,0

Domestic hot water supply (optional) lt/min 10,0 12,0 14,0

Power supply 220 V 50 Hz

220 V 50 Hz

220 V 50 Hz

Energy consumption W 150,0 165,0 165,0

Height A mm 1250 1250 1400

Width B mm 1190 1190 1235

Depth C mm 550 550 550

AC

B

Smoke Exhaust Ø100Air inlet Ø 60

Syst

em e

ntra

nce

3/4”

Hot

san

itary

1/2

”Co

ld s

anita

ry 1

/2”

Syst

em r

etur

n 3/

4”

top view

front view

back view

Page 25: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

KIT FOR CONTINUOUS DOMESTIC HOT WATER SUPPLY

Available for all Ungaro products except for AQA and ETHERMO

REMOTE DISPLAY AND ROOM THERMOSTAT

Description Code Price

Kit DHW KS € 300,00

Description Code Price

Remote display and room thermostat CP01284 € 208,00

Connecting cable 15 m CP00022 € 17,00

Accessories

KIT GPRS

Description Code Price

Kit GPRS CP00502 € 500,00

KIT ∆T 20°

Description Code Price

System return temperature control CP01285 € 200,00

ON-LINE AND FIRE-UP

Description Code Price

Web server for connection LAN - Main Board,Application for smartphone, tablet, PC, available on App and Play stores

CP01283 € 300,00

Page 26: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Selling conditions- Each order taken is subject to Ungaro S.r.l approval.- The merchandise always travels upon risk and danger of the buyer even if he does not pay for shipment.- Ungaro S.r.l shall not be liable for any damage during shipment. - On receipt of goods, the buyer has to check and to accept the goods, any discrepancies should be notified immediately and communicated to the transporter. If the damage is not evident at the moment of delivery, it is possible to communicate it to Ungaro S.r.l and to the transporter within and not over 7 (seven) days from the delivery date.- Prices in the price list do not include VAT.- Transport fees for peninsular territory of Italy 4%, for islands 5% extra on the invoice, VAT escluded.- The present price list cancels and substitutes the previous, and overrides the previous ones. It may be varied without prior notice.- Ungaro S.r.l reserves the right to make changes to the products without prior notice.

SOLAR TEMPERATURE PROBE AND WATER TANK PROBE

Description Code Price

Solar temperature probe CP00093 € 14,00

Water tank temperature probe CP00088 € 10,00

EXHAUST PIPE CARTER FOR FIT I

Description Code Price

Exhaust pipe carter FS00006 € 100,00

GLASS HEARTH

Description Code Price

Glass hearth 89 x94 cm PD1 € 95,00

Glass hearth 80 x80 cm PD2 € 90,00

PD2 PD1

Please visit our site www.caldoungaro.it for the latest updates and complete products specifications table.

Under no circumstances shall La Ungaro S.r.l assume liability for imprecise contents or eventual errors in this catalog. La Ungaro S.r.l reserves the right to make changes to the products without prior notice.

Accessories

Page 27: ViVi - eco2All · 7 AUTOMATIC ASH REMOVAL Ash is compacted in an easy to handle container on wheels 1 PNEUMATIC LOADING Allows to convey pellet to the boiler’s hopper from

Pric

e_b

lu -

10/

2015

www.caldoungaro.it

UNGARO SRL

Via San Mango, 288040 SAN MANGO D’AQUINO (CZ) [email protected] +39 0968 926838 / +39 0968 926857TEL +39 0968 96484 (TECHNICAL SERVICE)FAX +39 0968 926861

Via del Progresso, 5136054 MONTEBELLO VICENTINO (VI) [email protected] +39 0444 440963FAX +39 0444 440963

listo

cata

logo

_blu

e 07

.201

6