Verea s installation manual (september 2014)
-
Upload
ceramicaverea -
Category
Documents
-
view
231 -
download
1
description
Transcript of Verea s installation manual (september 2014)
Verea Spanish S Roof Tile
Installation Guide
Verea Spanish S Roof Tile Installation Manual
1
IDENTIFICATION OF ROOF AREAS
DISCLAIMER NOTICE It is important to recognize that these recommendations are neither warranties, explicit or implicit, nor representative of the only method by which Verea Spanish S roof tiles can be installed. Rather, they try to summarize for the designer, installer or developer good roofing practices and the requirements of various building code agencies. These guidelines may not be applicable in all geographical areas. It is the responsability of those individuals who are referring to these guidelines to independently research and determine which is best for their particular project.
Check with local authorities prior to installation
RIDGE
HIP
GABLE END
RAKE (left)
RAKE (right)
EAVE
SIDE WALL
FIELD OF ROOF
VALLEY
HEAD WALL
Verea Spanish S Roof Tile Installation Manual
2
IDENTIFICATION OF ACCESSORIES
Chimney
Bird Stop S
Hip Starter
Three-way ridge
Four-way ridge Hip & Ridge
Ridge end
Straight rake (right)
Straight rake (left)
Gable end detail Hip & Ridge detail
Under Hip & Ridge
Verea Spanish S Roof Tile Installation Manual
3
Please refer to:
Notice of Acceptance issued by Miami-Dade County NOA #14-0107.01 (available in our page web).
Concrete and Clay Roof Tile Installation Manual edited by FRSA & TRI (Florida Roofing, Sheet Metal and Air Conditioning Contractors Association, Inc & Tile Roofing Institute)
Concrete and Clay Roof Tile Installation Manual edited by TRI & WSRCA (Tile Roofing Institute & Western States Roofing Contractors Association)
for complete installation specifications.
DECKING
Solid decking shall be of proper thickness to be structurally adequate and properly fastened to support the loads. Decking material and installation of it shall comply with all local Building Code Requirements.
UNDERLAYMENT
Never install underlayment on wet, frozen or icy surfaces. Consult Local Building Codes for Compliance.
TILE APPLICATION 1. Tile Layout
1.1. Layout-Horizontal Mark horizontal lines at 16 ¾”, which will provide a nominal 3” headlap. Set first course at 19 ¾” less desired overhang from the eave. Overhang shall be ¾ to 2”.
1.2. Layout-Vertical Chalk vertical guidelines at 9.44” (between 9” ¼ and 9” ½ in an attempt to finish with a full tile at the gable ends).
Note: Due to the nature of clay, color and size variations may vary from technical data. Tile measurements should be checked at time of installation and adjust guidelines to assure a better tile installation.
Verea Spanish S Roof Tile Installation Manual
4
2. Rake/Gable Detail 2.1. Option 1: Barrel rake tile Secure each rake tile with two corrosion-resistant nails or screws of sufficient length to penetrate the framing a minimun of ¾”.
NOTE: Rake tile application at finishing end sealant may be needed.
2.2. Option 2: Straight rake tile
Secure each straight rake tile with two corrosion-resistant nails or screws of sufficient length to penetrate the framing a minimun of ¾”.
BIRDSTOP
RAKE (left) RAKE (right)
2x3 NAILER
2x2 NAILER
UNDERLAYMENT
NAIL or SCREW
2x3 NAILER
RAKE (left) RAKE (right)
BIRDSTOP
UNDERLAYMENT
Verea Spanish S Roof Tile Installation Manual
5
3. Eave Detail Install clay birdstops or metal eave closure to elevate the first course of field tile at the eave edge.
If Mortar Eave Closure is in place, apply mortar along the eave edge to elevate eave tile to be in plane with field tiles. Apply a minimun 3/8” weep hole at underlayment, one per tile.
4. Side Wall Detail
OVERHANG: ¾”to 2”
BIRDSTOP
FASCIA BOARD
UNDERLAYMENT
FIELD TILE
DRIP EDGE
TILE PAN FLASHING TILE PAN FLASHING
FLASHING
2x3 NAILER 2x3 NAILER
FLASHING
Verea Spanish S Roof Tile Installation Manual
6
5. Head Wall Detail
6. Hip and Ridge Detail
Pre-bagged or job mixed mortar may be used for weather blocking areas only. For slopes greater than 7:12 attach hip tile with a nail or screw.
FLASHING
REGLET
FLASHING CEMENT
FIELD TILE
UNDERLAYMENT
PLASTIC CEMENT
ADHESIVE
MORTAR AS A WEATHER BLOCK
Verea Spanish S Roof Tile Installation Manual
7
7. Installation over battens
Distance between horizontal battens: 16 ¾”, which will provide a nominal 3” headlap. First horizontal batten: 1” higher than the rest of the horizontal battens to elevate the eave end of the tiles to be on profile with the remaining roof tiles.
Distance between
horizontal battens
First horizontal
batten
Vertical batten