Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of...

20
logo area Validation of the crab-cavities internal monitoring strategy Vivien RUDE ESGT-CNAM 14 th International Workshop on Accelerator Alignment – 6 October 2016 The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. On behalf of MTI section

Transcript of Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of...

Page 1: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area

Validation of the crab-cavities internal monitoring strategy

Vivien RUDE ESGT-CNAM

14th International Workshop on Accelerator Alignment – 6 October 2016

The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

On behalf of MTI section

Page 2: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area

Outline

HL-LHC project HL-LHC crab-cavities and alignment requirements Alignment monitoring systems Test setup (under standard conditions) Test campaign results Conclusion

V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 2

Page 3: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 3

LHC upgrade : HL-LHC

From LHC to HL-LHC, luminosity will be multiplied by a factor 10.

Page 4: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 4

LHC -2016 : exploit only 30% of luminosity Crab cavities are proposed to provide bunch rotation to give a geometric overlap with the required crossing angle at HL-LHC

HL-LHC : Crab-cavities

Page 5: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 5

Operating conditions : • Radiation : 1 MGy / year • Vacuum : 10-6 mbar • Temperature : 4 K

Cryostat and cavities axes Alignment requirements :

+/-0.25 mm at 3σ

HL-LHC : Crab-cavities Composition : • 1 cryostat • 1 magnetic and thermal shielding • 2 helium tanks with 2 cavities • Suspension system

Suspension system

Magnetic and thermal shielding

Crab-cavity

Helium tank

Cryostat

Crab-cavity axis

2 Solutions based on: Distance measurements Angle measurements

Page 6: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 6

The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

Measurement interferometer

Measured distance

Aspheric lens Fibre mount

Connector

Optical fibre

Collimator

Retro-reflector (CCR 1.5)

Reference interferometer

Ratio of measurement interferometer to reference interferometer fringes

Absolute Distance

FSI : Frequency Scanning Interferometry (Absolute Distance)

Focal point

Page 7: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 7

The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

Angle

lens

BCAM : Brandeis Camera Angle Monitor (Angle measurement)

CCD Focal point

Target

Spot Image of the target

Based on image acquisition of reflective targets

Glass ball (reflective index = 2)

R-BCAM

Page 8: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 8

Cryostat

R-general

Cryostat axis

BCAM device

FSI device

Magnetic and thermal shielding

The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

Tunnel condition

Operating condition

Feedthrough

Position monitoring strategy

Viewport

Page 9: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 9

Test campaign

Goal : Compare both alignment monitoring systems (accuracy) under standard conditions:

• Room temperature (~20°C) • Atmospheric pressure • No radiation

Test setup Helium tank mock up (CMM measurement :

micrometric uncertainty)

R-general

Page 10: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 10

R-general

Test campaign

Page 11: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 11

Parameters Precision Tx : radial (mm) 0.021

Ty : vertical (mm) 0.009

Tz : longitudinal (mm) 0.028

Rx : pitch (mrad) 0.030

Ry : yaw (mrad) 0.072

Rz : roll (mrad) 0.187

FSI alignment strategy and results

R-general

R-general R-cavity

z

y

R-Cavity

R-FSI 1

Page 12: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 12

Parameters Precision Tx : radial (mm) 0.026

Ty : vertical (mm) 0.016

Tz : longitudinal (mm) 0.622

Rx : pitch (mrad) 0.057

Ry : yaw (mrad) 0.057

Rz : roll (mrad) 0.083

BCAM alignment strategy and results

R-general

R-cavity

R-general R-cavity R-BCAM 1

Page 13: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 13

The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

Comparison with AT401

FSI BCAM

Laser Tracker

Page 14: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area 14

• Both systems have been tested under standard conditions and their accuracy meet the alignment requirements.

• Their results were compared to laser tracker measurements and their differences were acceptable.

• Cryogenic and radiation tests are in progress in order to validate the FSI strategy.

• BCAM solution will only be used during the cooling process (cross-checking measurements).

Conclusion

V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016

Page 15: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area 15

Thank you for your attention

Acknowledgement: Thibault Dijoud, Mateusz Sosin, Hélène Mainaud Durand, Mathieu Duquenne, Andreas Herty, Bruno Perret, Michel Rousseau, Antonio Marin, Michael Udzik

The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

Page 16: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 16

SPARE

Page 17: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 17

Results: Leica BRR 1.5’’

10MGy

500kGy 4MGy 7MGy

Microscope views

7MGy 7MGy 10MGy

Page 18: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 18

Results: PLX Ceramic BMR 1.5’’

10MGy

100kGy

Microscope views

7MGy 7MGy 10MGy

Page 19: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 19

Results: PLX Ceramic BMR 1.5’’

ΔZ P1

P2

P3

Shift measured at 10MGy with AT401: 22µm (centring of optics < 5µm)

Shift measured at 10MGy with AT401: 28µm (centring of optics < 10µm)

Distance variations (ΔZ) after thermal correction

Page 20: Validation of the crab-cavities internal monitoring strategy · logo area V.RUDE - Validation of the crab- cavities internal monitoring strategy - IWAA 2016 6 The image cannot be

logo area

Z

X

Y

V.RUDE - Validation of the crab-cavities internal monitoring strategy - IWAA 2016 20

C

K1 The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

K2

K3

K4

lens

R-FSI mount

FSI absolute calibration

Xc (1σ) : 10 µm