V0808 New Features DRIVER En

1
New Software Features AXD and SPD drives (V8.08) Date: Dec.2nd, 2014 Fagor Automation From: CNC Marketing Department FOR: Fagor Automation Network + Service Centers Page 1 of 1 Contact: [email protected] Doc. Name: New_Features_DRIVER_V8.08_14_12_en.doc INDEX 1 New FEATURES........................................................................................................ 1 1.1 Changes in Sercos synchronization with two drives. .................................................................. 1 1.2 Raised limit of FP1 and FP20 .......................................................................................................... 1 1.3 New motors have been added ......................................................................................................... 1 1 NEW FEATURES. 1.1 Changes in Sercos synchronization with two drives. The bode on gantry, tandem drives has been repaired. Internal variable of the DSP %v1 contadorparasincronizar (counter for synchronizing). 1.2 Raised limit of FP1 and FP20 The limit of parameters 32000 to 80000 has been raised. 1.3 New motors have been added FKM43, FKM63 and FKM85 electro-ventilated motors FM9-B037-C5CX-E0X motor Siemens motors 1PH8135-1NF2X-XXXX, 1PH8135-1NG2X-XXXX

description

fagor

Transcript of V0808 New Features DRIVER En

  • New Software Features AXD and SPD drives (V8.08)

    Date: Dec.2nd, 2014

    Fagor Automation From: CNC Marketing Department

    FOR: Fagor Automation Network + Service Centers Page 1 of 1

    Contact: [email protected] Doc. Name: New_Features_DRIVER_V8.08_14_12_en.doc

    INDEX

    1 New FEATURES........................................................................................................ 1 1.1 Changes in Sercos synchronization with two drives. .................................................................. 1 1.2 Raised limit of FP1 and FP20 .......................................................................................................... 1 1.3 New motors have been added......................................................................................................... 1

    1 NEW FEATURES.

    1.1 Changes in Sercos synchronization with two drives. The bode on gantry, tandem drives has been repaired. Internal variable of the DSP %v1 contadorparasincronizar (counter for synchronizing).

    1.2 Raised limit of FP1 and FP20 The limit of parameters 32000 to 80000 has been raised.

    1.3 New motors have been added FKM43, FKM63 and FKM85 electro-ventilated motors FM9-B037-C5CX-E0X motor Siemens motors 1PH8135-1NF2X-XXXX, 1PH8135-1NG2X-XXXX