Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 1 of 36
Model LL Model PL
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 2 of 36
ContentsFeatures & Benefits 3
General Instructions 4
Introduction 4
Installation 5Mounting 5Plumbing Model LL 6Plumbing Model PL 8Electrical 9
Remote Alarm Wiring Model LL 10, 12
Remote Alarm Wiring Model PL 11, 12
Installation – Pigtails & Cylinders 13
Start Up & Checking Procedures Model LL 15
Start Up & Checking Procedures Model PL 17
Emergency Reserve Plumbing & Wiring Models LL & PL 18
Cylinder Replacement & Handling 19
Line Delivery Pressure Adjustment 19
Programming Adjustments 20
General Maintenance 21
Table of Error Codes 21
Table of Alarm Codes 22
Replacement Parts 23
Trouble Shooting Guide 25
Appendix A Glossary of Terms 27
Appendix B Technical Specifications 28
Appendix C Operational Pressure Specifications 29
Appendix D Wiring Diagram 30
Appendix E Wiring Diagram for Buzzer Kit 31
Warranty 32
Technical Assistance 1-888-769-7979
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 3 of 36
Features & Benefits• Fully automatic changeover • Novalvesorleverstoresetaftereachchangeover.
• Compatible with Powerex T-Net medical gas monitoring system • Savestimeandimprovessafety.
• Economizer software • Ensuresemptyportablebulkvesselswillnotbeputback intoreserveandtheentireliquidcontentsofportablebulk vesselsisused.
• Economizer hardware • Allowsheadpressurefromsecondaryportablebulk vesselstobeused–insteadofvented.
• Field upgradeable design • Kitsallowunittobechangedfrom-i.e.cylindersto portablebulkorfromstandardflowtohighfloworfrom lowerdeliverypressuretohigherdeliverypressure.
• Circuit board triggers all required NFPA 99 alarms • Simplifyingwiringandreducingcost.
• Unit includes hi/low line pressure transducer • Eliminatingneedtopurchasehi/lowpressureswitch improvingalarmaccuracyandimprovingsafety(manifold willautomaticallyalarmifatransducergoesbad).
• Easy to service layout/design
• Microprocessor-based control panel • IncorporatesLED’sandilluminatedtextdisplayreadable eveninpoorlightingconditions.
• Electronic monitoring of circuits • Upto19error,alarmorinformationmessagesdisplayed foreaseofmaintenance.
• Accurate, long life pressure transducers for monitoring of line pressure and bank pressures
• Analog gauges also provided for use in event of power failure
• Pressures may be displayed in PSIG / kPa / BAR
• Built in DISS gas specific emergency feed ports
• Built in emergency reserve bank ports
• Input power 120 VAC, 50 to 60 Hz (120–240VAC,50to60Hzonallmodelswithoutheaters)
• Dual line pressure regulators on NFPA 99 models
• Gas specific header bar with integral check valves and cylinder pigtail assemblies
• Variety of header configurations available to meet the available space requirements of your installation
• Available in weatherproof cabinet for outdoor installation
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 4 of 36
IntroductionPowerex manifolds are cleaned for use with oxygen. Eachsystemistestedforchangeover,triggeringofalarmsandleakage.Eachunitisdesignedandpreparedfortheindicatedgasservice.Powerex manifolds are built in accordance with the NationalFire Protection Association and Compressed Gas Associationguidelines.
WarrantyAllPowerexmanifoldsarewarrantedagainstdefectsinmaterialand workmanship for the period of one year from date ofpurchase. All circuit boards are warranted against defects inmaterial andworkmanship for the period of three years fromdateofpurchase.
General Instructions/Location & ShelterManifolds should be installed in accordance with guidelinesstatedbytheNationalFireProtectionAssociation,theCompressedGasAssociation,OSHA, andall applicable local codes. Centralsupplysystemsandcylindersshouldnotbeplacedinalocationwherethetemperaturewillexceed125°F(51.6°C)orfallbelow-20°F(-29°C).Amanifoldplacedinanopenlocationshouldbeprotectedagainstweatherconditions.Duringwinter,protectthemanifoldfromiceandsnow.Insummer,shadethemanifoldandcylindersfromcontinuousexposuretodirectsunlight.Theflowcapacityofnitrousoxideandcarbondioxidemanifoldsdependuponambienttemperatureandthenumberofcylindersonline.Contact your gas supplier to determine the vaporization rateofCarbonDioxideandNitrousOxidecylinders for theambienttemperatureclimateattheinstallationsite.
Leaveallprotectivecoversinplaceuntiltheirremovalisrequiredfor installation. This precautionwill keepmoisture anddebrisfromthepipinginterior.
CautionFailure to follow the following instructions can result inpersonalinjuryorpropertydamage:
• Neverpermitoil,grease,orothercombustiblematerials tocomeincontactwithcylinders,manifold,and connections.Oilandgreasemayreactwithexplosive forcewhenignitedwhileincontactwithsomegases– particularlyoxygenandnitrousoxide.• Cylinderandmastervalvesshouldalwaysbeopenedvery slowly.Heatofrecompressionmayignitecombustible materialscreatinganexplosiveforce.
• Pigtailsshouldneverbekinked,twisted,orbentintoa radiussmallerthan3inches.Mistreatmentmaycause thepigtailtoburst.
• Donotapplyheat.Oilandgreasemayreactwith explosiveforcewhenignitedwhileincontactwithsome gases–particularlyoxygenandnitrousoxide.
• Cylindersshouldalwaysbesecuredwithracks,chains,or straps.Unrestrainedcylindersmayfalloveranddamage orbreakoffthecylindervalvewhichmaypropelthe cylinderfromitscurrentposition.
• Oxygenmanifoldsandcylindersshouldbegrounded. Staticdischargesandlightningmayignitematerialsinan oxygenatmosphere,creatingafireorexplosiveforce.
• Weldingshouldnotbeperformednearnitrousoxide piping.Excessiveheatmaycausethegastodissociate, creatinganexplosiveforce.
• Removeallprotectivecapspriortoassembly.The protectivecapmayigniteduetoheatofrecompression inanoxygensystem.
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 5 of 36
Control Cabinet Installation• Determineandmarktheverticalcenterlineforinstallationofthemanifoldcontrolcabinet.
• If you wish to place cylinders under themanifold cabinet,measure from thefloor to a point 79” in height above thefinished floor of this vertical line. Using a level, mark ahorizontallineatthispointextendingapproximately7”totheleftand7”totherightofcenter.ThislineindicatesthelocationforthebottomtwomountingboltsoftheZmountingbracket.MountingtheZbracket@79”aff*willresultinthebottomofthemanifoldcabinetbeing60”aff–allowingcylinderstobeplacedunderthemanifoldcabinet.Ifyoudonotwishtoplacecylindersunderthemanifoldcabinet,measurefromthefloortoapoint58½”affandfollowthesamestepsabove.
•Mount the Zmounting bracket to the wall using fastenerssuitableforthetypeofwallconstruction.
• TemporarilyhangthemanifoldcabinetontheZbracketjustinstalled, mating it with the Z bracket on the back of themanifoldcabinet.Markthelocationsofthetwolowercabinetmountingholesonthewall.
• Remove themanifold cabinet and install female portion ofsuitablefastenersforlowercabinetmountingholes.
• Re-hangthemanifoldcabinetandinstallsuitablefastenersinthelowercabinetmountingholes.
*aff=abovefinishedfloor
Header Installation• Attachtheheaderstotheuniononeachsideofthemanifoldcontrol cabinet. Using a level, mark the placement ofmountingbracketswhilekeepingtheheaderonahorizontalplane.
• Remove the U-bolt assemblies from the header mountingbrackets.Positionthebracketssothatthetopofthebracketis alignedwith the bottom of the headers and is centeredbetweenthecylinderconnections.Theendbracketshouldbeplacedasclosetothelastcylinderaspossibletoprovidethemostsupportandstability.
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 6 of 36
•Markthemountingholeandinstallfastenerssuitablefortypeofwallconstruction.
• Fit the U-bolt over the header piping and tighten the twomountingnuts.
Plumbing – Model LL• The outlet of themanifold is located at the top center ofthe unit as shownhere. Theoutlet connection is 1/2NPTfemale. A sourcevalve1/2MNPTx¾ tubeextensionhasbeenprovidedwithallNFPA99compliantmodels(part#48-0023)andshouldbeinstalledinthemanifoldoutlet.Itmaybenecessarytoinstalla1/2NPT90°streetelbow(part#17-0300soldseparately)tomeettheconfinesoftheinstallationsite.
• Source valve part # 48-0023 (should be installed on themanifoldcabinetpriortomountingonthewall).
Recommended Vent Line and Emergency Reserve Plumbing
Emergencyreservelowpressuretransducer(14-3001-12)
Union(suppliedbycontractor)Linepressurereliefvalve(1/2Fnptoutletconnection)
The installing contractor will need toprovide fittings and type K coppersufficienttoinstalltheemergencyreserveandventlines.Asindicatedbythedottedlinesinthisdrawing.
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 7 of 36
Plumbing – Model LL• In addition to connecting the left & right primary andsecondaryportablebulkvesselsupplybanks,theLLmodelsmust also have a high pressure reserve bank of cylindersconnectedtothecabinettobeincompliancewithNFPA99guidelines.
• ThemodelLLhasone½NPTfemalelinepressurereliefvalveconnection and two3/8NPT female intermediate pressurerelief valve connections. (This installation is typical –withthetwo intermediatereliefvent linesandthe linepressurereliefventlinebroughttogetherasacommonventlinethatexitsthefacilityeitherthruanexteriorwallortheroof).Seebottomofpage6.
• The intermediate block has a ½ npt plug which may beremoved to allow the emergency reserve to be piped inthrougheithertheleftortherightsideofthecabinet.Slotshavebeenprovidedonboth the leftand right sidesof thecontrolcabinettoallowforthehighpressurereservepiping.
• Emergency reserve in use pressure transducer (14-3002) –installedinfactorywhenorderedwithLLmanifold.
• CV-050Fcheckvalve(mustbeinstalledbetweenthemanifoldcabinet and downstream of the high pressure reserveregulator).
Emergencyreservelowpressuretransducer(14-3001-12)installedintoportonRWPreservemanifoldbyplumber.
Unions(suppliedbycontractor)
Emergencyreservelowpressuretransducer(14-3001-12)
HighpressurereservemanifoldMainlineoutletconnection
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 8 of 36
Plumbing – Model PL• Inadditiontoconnectingtheleftprimaryportablebulkvesselsupplybank, thePLmodelsmustalsohaveahighpressurereserve bank of cylinders and a high pressure emergencyreservebankofcylindersconnectedtothecabinettobe incompliancewithNFPA99guidelines.
• Atransducer(part#14-3001-5)mustbeinstalled(byinstaller)into the port provided in the right / secondary manifoldheader.
• ThemodelPLhasone½NPTfemalelinepressurereliefvalveconnection and one ⅜ NPT female intermediate pressurereliefvalveconnections.(Thisinstallationistypical–withtheintermediatereliefventlineandthelinepressurereliefventlinebrought togetherasacommonvent line thatexits thefacilityeitherthruanexteriorwallortheroof).(Seedrawingatbottomofpage).
• The intermediate block has a ½ npt plug which may beremoved to allow the emergency reserve to be piped inthrougheithertheleftortherightsideofthecabinet.Slotshavebeenprovidedonboth the leftand right sidesof thecontrolcabinettoallowforthehighpressurereservepiping.
• Emergency reserve in use pressure transducer (14-3002) –installedinfactorywhenorderedwithPLmanifold.
• CV-050Fcheckvalve(mustbeinstalledbetweenthemanifoldcabinet and downstream of the high pressure reserveregulator).
Emergencyreservelowpressuretransducer(14-3001-12)installedintoportonRWPreservemanifoldbyplumber.
Emergencyreservemanifoldsupply
Primary/portablebulksupply Reserve/secondary
manifoldsupply
The installing contractor willneedtoprovidefittingsandtypeKcoppersufficienttoinstalltheemergency reserve and ventlines.Asindicatedbythedottedlinesinthisdrawing.
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 9 of 36
Electrical• Useoneofthetwo½”conduitknock-outsprovidedlocatednearesttothetopleftcornerofthecabinettorouteconduittosupply120VACtothepowersupply.
Note: Separateconduitshouldbeusedforlowvoltagewires(useknockoutsprovidedontheleftsideofthebox).
120-240/1/50–60Hzmaybeusedwithallunits.Iftheunithasheaters,theheatersonlymaybewiredto120/1/50-60.Anadditionaltransformer(soldseparatelypart#35-3004)isrequiredtoconnectheatersto240VAC.
• Remove the power supply cover by loosening the screwlocatedat the topof the coverand then sliding thepowersupplycovertotherightuntilthescrewisinthecenterofthetear-dropshapedcutout.Next,pullthecoverforwarduntilitclearsthescrewheadandthefuse.Note:thebottomofthecoverinsertsintoaslotinthebackplate.Allowthecovertorestontheduallineregulatorassemblyplumbingjustbelowthepowersupply.
• Route wires of proper gauge (per local building coderequirement) through the power supply conduit, thru thegrommetonthepowersupplybracketandintotheterminalstrip.
• Connect the 120 VAC facility emergency power sourceelectricalwiringtotheterminalstripprovidedonthefrontofthepowersupplymountingbracket(perphotosright).
(N=neutral,L=load,FG=fieldground). Note:Thegroundmustbeasolidearthgroundwithlittleornoresistance.A“noisy”earthgroundmayaffectthedigitaldisplayofthemanifold.
Conduitknockoutsfor120VAC Conduitknockoutforlowvoltage alarm signals
Neutral
Load
FieldGround
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 10 of 36
Wiring – Remote Alarms – Model LLCaution: Never connect or disconnect any electrical components with the power on. This may result in damage to components and is not covered under warranty.
•Wires for remote alarms should be brought into thecabinet thru conduit or shielded cables (check local coderequirements) thru the knockouts on the left side of thecabinetshownhere.
Note: Separate conduit should be used for high voltagewires–neverrun lowvoltagewires inthesameconduitashighvoltagewires.
• IfyouareinstallingamodelLLwithemergencyreservetherearefivealarmsignalsrequiredperNFPA99:
•HighLinePressure • LowLinePressure • SecondaryinUse • EmergencyReserveinUse • EmergencyReserveLow
The circuit board will trigger all five of these alarms (nopressureswitchesarerequired).Thelinepressuretransducermustbeinstalledoutsideofthecabinet–downstreamofthesourceormain linevalvewiththecablebeingwiredtothemanifoldcircuitboardtocomplywithNFPA99.Inthisphotothe line pressure transducer has been assembled into ourPSM-XX assembly and connected to the gaugeport on thedownstream(patientside)ofthesourcevalveandwiredtothemanifoldcircuitboard.
• Thelinepressuretransducermayalsobemountedinsidethecabinet (as shown here). In this arrangement, a high/lowpressureswitch(soldseparately)willberequiredtomeettheNFPA99recommendations.
Note: Thehi/lowpressureswitch(suppliedseparately)wouldbewired directly to themaster alarm panels – not to themanifoldcircuitboard.
• Remote alarmwires are connected to the circuit board atthe terminal gate labeledMB5. Signalwires andCommonwiresfor;LowLinePressure,HighLinePressure,SecondaryinUse,EmergencyReserveinUseandEmergencyReserveLowshouldbeconnectedtotheterminalsasindicated.
Note: Allremotealarmterminalsarenormallyclosedwhenthegaspressureisinthenormalrange.Thehi/lowsetpointspre-programmed into themanifold circuit board logic chipareasperthechartsonpage31.Ifdesired,thehighandlowlinepressurealarmsetpointsmaybeadjustedbyfollowingtheinstructionsonpage20.
Knockoutforlowvoltageremotealarmwiring
Linepressuretransducer
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 11 of 36
Wiring – Remote Alarms – Model PLCaution: Never connect or disconnect any electrical components with the power on. This may result in damage to components and is not covered under warranty.
•Wires for remote alarms should be brought into thecabinet thru conduit or shielded cables (check local coderequirements) thru the knockouts on the left side of thecabinetshownhere.
Note: Separate conduit should be used for high voltagewires–neverrun lowvoltagewires inthesameconduitashighvoltagewires.
• IfyouareinstallingamodelLLwithemergencyreservetherearefivealarmsignalsrequiredperNFPA99:
•HighLinePressure • LowLinePressure • SecondaryinUse • EmergencyReserveinUse • EmergencyReserveLow
The circuit board will trigger all six of these alarms (nopressureswitchesarerequired).Thelinepressuretransducermustbeinstalledoutsideofthecabinet–downstreamofthesourceormain linevalvewiththecablebeingwiredtothemanifoldcircuitboardtocomplywithNFPA99.Inthisphotothe line pressure transducer has been assembled into ourPSM-XX assembly and connected to the gaugeport on thedownstream(patientside)ofthesourcevalveandwiredtothemanifoldcircuitboard.
• Thelinepressuretransducermayalsobemountedinsidethecabinet (as shown here). In this arrangement, a high/lowpressureswitch(soldseparately)willberequiredtomeettheNFPA99recommendations.
Note: Thehigh/lowpressureswitchwouldbewireddirectlyto the master alarm panels – not to the manifold circuitboard.
• Remote alarmwires are connected to the circuit board atthe terminal gate labeledMB5andMB4. Signalwires andCommonwires for; Low Line Pressure, High Line Pressure,SecondaryinUse,EmergencyReserveinUseandEmergencyReserve Low should be connected to the terminals asindicatedonMB5.TheSignal&CommonwiresforSecondary(right bank) Low should be connected to the terminals asindicatedonMB4.
Note: Allremotealarmterminalsarenormallyclosedwhenthegaspressureisinthenormalrange.Thehi/lowsetpointspre-programmed into themanifold circuit board logic chipareasperthechartsonpage31.Ifdesired,thehighandlowlinepressurealarmsetpointsmaybeadjustedbyfollowingtheinstructionsonpage20.
Linepressuretransducer
Knockoutforlowvoltageremotealarmwiring
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 12 of 36
Wiring – Remote Alarms – Model PLCaution: Never connect or disconnect any electrical components with the power on. This may result in damage to components and is not covered under warranty.
• BOTH MODELS LL & PL–The14-3001-12emergencyreservelowtransducermustbewiredtothemanifoldcircuitboardat the MB-3 connection points labeled “High PressureEmergencyReservePressureSensor”.
• MODEL PL ONLY–The14-3001-5Secondary(rightbank)LowtransducermustbewiredtothemanifoldcircuitboardattheMB-2connectionpointslabeledRightBankPressureSensor.
14-3001-12wiringlocation
14-3001-12wiringlocation
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 13 of 36
Installing Pigtails & Attaching Cylinders• This drawing above shows a completed installation. Notethecopperventtubingandtubingbetweentheemergencereserve manifold and control cabinet are installed and furnishedbytheinstaller.Theunionspart#’sare17-0169forthe line relief and 17-0271 for the intermediate vent relief(tworequiredformodelLLifinstalledindoors).
• ThecheckvalveoutletfittingsonthemanifoldheaderbarsareCGA(CompressedGasAssociation)gasspecificthreads.Eachofthesefittingshasanintegralcheckvalve.Makesurethe 3 digit CGA number stamped on the outer perimeterof thesefittingsmatches theCGAnumber stampedon thematingCGAfittingsonthepigtails.Attachthepigtailstothecheckvalveoutletfittingsonthemanifoldheaderbars.
• Connecttheotherendofthepigtailtothe“Use”valvematingfittingontheportablebulkvessel.Opentheusevalve(turncounter-clockwise to open). The pressure building valveor regulator should be turned on or opened for all vesselsconnectedtothemanifold(bothserviceandreservebanks).Allowapproximately1hourfortheportablebulkvessel(s)tobuildpressure.
• Checkallcylinderandpigtailconnectionsfor leaksusinganoxygensafe leak test solution (anybubbles formingaroundconnectionsindicateleakage).
• Verify that the pressure being supplied to the manifoldcabinet exceeds the minimum inlet pressure requirementsperthetableonpage31.
Intermediaterelieflinewithunionforleftbank,rightbank.Finallineventlinewithunion.Linereliefis½Fnpt,intermediatereliefis⅜Fnpt.
Commonventlinethrurooforoutsidewall.(¾recommended)
Emergencyreserveinlet
Unions
Portsfortwopigtails
Intermediate pressurereliefvalvex⅜Fnpt
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 14 of 36
• ThecheckvalveoutletfittingsonthemanifoldheaderbarsareCGA(CompressedGasAssociation)gasspecificthreads.Eachofthesefittingshasanintegralcheckvalve.Makesurethe 3 digit CGA number stamped on the outer perimeterof thesefittingsmatches theCGAnumber stampedon thematingCGAfittingsonthepigtails.
• Connectthepigtailstothecheckvalveoutletsonthemanifoldheaders.
• Check themaster valves to be certain they are open (turncounter-clockwisetoopen).(Note:themastervalveshouldalwaysbeleftopen.Itistobeusedonlyintheeventofanemergency).
• SLOWLYopenallcylindervalvesuntilfullyopen(turncounter-clockwisetoopen).Checkallcylinderandpigtailconnectionsforleaksusinganoxygensafeleaktestsolution(anybubblesformingaroundconnectionsindicateleakage).
Note: Themanifoldhasbeentestedforleaksatthefactory,buttheinstallerMUSTcheckforleaksatallconnectionsmadeduringinstallation.
Master valve
Attachpigtailstoheadercheckvalve outlets using1⅛”openendwrench
Checkvalveoutletfittings
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 15 of 36
Start Up & Checking Procedures – Model LLThemanifoldispre-programmed(perpage31)andtestedbeforeit is shipped. Youmay, however,wish tomodify some of theprogramming(seepage20).Theunithasbeendesignedtoallowsomeprogrammingtobesimplyandsafelyalteredinthefield.
• Start with all cylinders turned off and with zero pressuresuppliedtothemanifoldcabinet.Toconducttheinitialstart-uptestingofthemanifold,itissimplerandfasterifthecircuitboardisswitchedfromthestandard‘cyclingview’(thisisthemodeinwhichitisshipped)tothe‘globalview’.Todothis,thecovermustbe removed fromthecircuitboardand thetop#1dipswitchmustbeswitchedfromtheRUNmodetothePROGRAMmode.(Note:localalarmsarenotdisplayedwhenintheglobalviewmode).
• Turnonthe120VACtotheunit.ForbothmodelsLL&PLwithEmergencyReserveheadersutilizingthe14-3001-12,14-3002and 14-3001-5 (PL only) transducers, the display shouldilluminateshowingallzerosfortheLinePressure(LIN),LeftBankPressure(LEFT)andRightBankPressure(RIGHT). Theintermediate(INT)andemergencyreserve(EMER).(Note:IftheLLorPLhasbeeninstalledwithoutanEmergencyReserveor with an Emergency Reserve utilizing pressure switchesin place of transducers, the INT (intermediate) and EMER(emergency reserve) can both be made to read zeros if a35-3013emergencyreservejumperkitisinstalled.BoththeleftandrightbankGreen(InUse)andYellowLED’s (Ready)shouldbeextinguishedandtheRed(Empty)LED’sshouldbeilluminated.
• Verifythattheleftvesselhas130psigorhigherbyobservingthepressuregaugeonthevessel.SLOWLYopenonecylindervalveontheleftbank.Theleftbankpressuregauge(insidethe cabinet) and the text display (on the outside of thecabinet) shouldshowthe fullpressureof thecylinder. TheRed(Depleted)LEDfortheleftbankshouldhaveextinguishedleavingonlytheGreen(InUse)LEDilluminated.
• Verifythattherightvesselhas130psigorhigherbyobservingthepressuregaugeonthevessel.SLOWLYopenonecylindervalve on the right bank. The right bank pressure gauge(inside the cabinet) and the digital display (on the outsideofthecabinet)shouldshowthefullpressureofthecylinder.The Red (Depleted) LED for the right bank should havebeenextinguishedand theYellow (Ready) LED shouldhaveilluminated.
Programcontrolbuttons
Dipswitch#1Run/Program
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 16 of 36
• Turn off all open left bank cylinder valves. Create a slightflow of gas in the delivery pipeline system. DISS demandvalves have been provided on the line regulators. MatingDISSfittingsmaybeusedtocreateaflowofgaswithinthemanifold cabinet. The left bank pressure text display andpressure gauge should fall and the control automaticallyswitches over to the right bank. Delivery pressure remainsconstant.TheleftbankRed(Empty)LEDwillilluminate.Thesecondarysupplyinusealarmshouldactivateonthemasteralarm(s).
• SLOWLY reopen the cylinders on the left bank. The leftbankpressuregaugeanddigitaldisplayshouldreturntofullpressure. The left bank yellow (Ready) LED will illuminatesimultaneouslytheleftbankred(Empty)willextinguish.Allremotesecondarysupplyinusealarmswillbecanceled.
• Repeatsteps5&6tosimulateanemptyrightbank.
• ThemodelLL,willalsodisplaypressuresfortheintermediatearea (INT) and the emergency reserve (EMER) and triggerthemasteralarmsignalfor“EmergencyReserveinUse”and“EmergencyReserveLow”.Toproperlyadjusttheemergencyreserveregulatortheprimaryandsecondarybanksmustbothbeshutoffandthecabinetpressuredrained.SLOWLYopenone cylinder on the emergency reserve bank and observetheEMERpressuredisplayandchecktomakesureitagreeswiththegaugeontheemergencyreserveregulator. Adjustthedeliverypressurefromtheemergencyreserveregulatorfollowingthetableonpage31(ifthisisa50psiglinepressureapplication this regulator should be set to 65psig). WhentestingtheEmergencyReserveinUseandEmergencyReserveLowmasteralarmspleasenote–thereisa15seconddelaydesigned into the manifold logic. The Emergency Reservein Use alarmwill be triggeredwhen the INT pressure fallsbelow 75 psig (50 psig line pressure application) for morethan15seconds.TheEmergencyReserveLowalarmwillbetriggeredwhentheEMERpressurefallsbelow1200psigformorethan15seconds. TesttheEmergencyReserve inUsealarmbyfirstpressurizingboththeprimary&secondaryandtheemergencyreservebanks,setDipswitch#1totheRUN/PROGRAMpositionandclosethevalvesonboththeprimary& secondary bank vessels, establish a gas flow thru themanifold.Aftertheprimarythensecondarybanksdepletetoempty,andtheintermediatepressurefallsbelow75psig(50psilinepressureapplicationmodels)theEmergencyReserveinUsealarmshouldbetriggeredaftera15seconddelay.
• After you are satisfied that the manifold is functioningproperlyandthatallmasteralarmsignalsarebeingtriggeredproperly. Themanifold circuit board should be returned tothe‘cyclingview’mode.ThisisachievedbymovingthedipswitchfromthePROGRAMtotheRUNposition.
Dipswitch#1settoRun/Program
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 17 of 36
Start Up & Checking Procedures – Model PL• Turnoffallopenleftbankvesselvalves.Createaslightflowofgasin the delivery pipeline system. DISS demand valves havebeenprovidedonthelineregulators.MatingDISSfittingsmaybeusedtocreateaflowofgaswithinthemanifoldcabinet.Theleftbankpressuretextdisplayandpressuregaugeshouldfallandthecontrolautomaticallyswitchesovertotherightbank. Deliverypressureremainsconstant.TheleftbankRed(Empty)LEDwill illuminate.Thesecondarysupplyinusealarmshouldactivateonthemasteralarm(s).
•Withtheleftbankinared(Empty)conditionandtherightbankinagreen(InUse)condition,createaslightgasflowandcloseallof therightbankcylindervalves. Whentherightbankpressuredropsbelow1,200psigstopthegasflow.Afterapproximately15seconds,therightbanklowalarmwillbetriggered.
• SLOWLY reopen the vessel(s) on the left bank. The left bankpressuregaugeanddigitaldisplayshouldreturnto fullpressure.Theleftbankgreen(InUse)LEDwillilluminatesimultaneouslytheleftbankred(Empty)willextinguish.Allremotesecondarysupplyinusealarmswillbecanceled.
• Theunitwillalsodisplaypressuresfortheintermediatearea(INT)andtheemergencyreserve(EMER)andtriggerthemasteralarmsignal for “Emergency Reserve inUse” and “Emergency ReserveLow”. To properly adjust the emergency reserve regulator theprimaryandsecondarybanksmustbothbeshutoffandthecabinetpressure drained. SLOWLY open one cylinder on the emergencyreservebank andobserve theEMERpressuredisplay and checktomakesureitagreeswiththegaugeontheemergencyreserveregulator. Withaslight flowofgas,adjust thedeliverypressurefromtheemergencyreserveregulatorfollowingthetableonpage31(ifthisisa50psiglinepressureapplicationthisregulatorshouldbeset to65psig). When testing theEmergencyReserve inUseandEmergencyReserveLowmasteralarmspleasenote–thereisa15seconddelaydesignedintothemanifoldlogic.TheEmergencyReserveinUsealarmwillbetriggeredwhentheINTpressurefallsbelow75psig(50psiglinepressureapplications)formorethan15seconds.TheEmergencyReserveLowalarmwillbetriggeredwhentheEMERpressurefallsbelow1200psigformorethan15seconds.TesttheEmergencyReserveinUsealarmbyfirstpressurizingboththeprimary&secondaryandtheemergencyreservebanks,setDipswitch#1RUN/PROGRAMpositionandclose thevalvesonboththeprimary& secondarybank vessels, establish a gas flow thruthemanifold.Aftertheprimarythensecondarybanksdepletetoempty, and the intermediate pressure falls below75psig (50 psilinepressureapplicationmodels) theEmergencyReserve inUsealarmshouldbetriggeredaftera15seconddelay.
• After you are satisfied that themanifold is functioning properlyand that all master alarm signals are being triggered properly.The manifold circuit board should be returned to the ‘cyclingview’mode.This isachievedbymovingthedipswitchfromthePROGRAMtotheRUNposition.
Dipswitch#1settoRun/Program
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 18 of 36
Emergency Reserve Plumbing and WiringThe manifold includes digital displays for the emergency reservebankpressureandtheintermediateareapressure.(RefertoappendixE–page31).
Remote master alarms will be triggered by the manifold for therequiredNFPA99alarms;
• Highlinepressure,
• Lowlinepressure,
• Secondaryinuse,
• Emergencyreserveinuseand
• Emergencyreservelowand
• Rightbank(secondary)low(onPLunitsonly)
Refer to theappendixEonpage31 for informationonsetting thedelivery(outlet)pressureoftheemergencyreserveregulatorandpre-programmedemergency reserve inuseandemergency reserve lowalarmsetpoints.
The emergency reserve low bank pressure transducer (part # PX-14-3001-12)shouldbeinstalledontheextraportontheRWPseriesmanifold.Thisportislocatedprior(upstream)tothemastervalveandtheregulator.
Note: if the PX-14-3001-12 and PX-14-3002 transducers are notused (and pressure switches are used instead or not used at allbecauseareservemanifoldisnotbeingused)the“ReserveAlarms”programmingoption(seepage20)mustbedisabledandthe35-3013highpressurereservejumperkitmustbeinstalledorelseerrorcodeswillbedisplayedbythecircuitboard.
The emergency reserve in use pressure transducer (part # PX-14-3002)will be pre-installedon the intermediateblock at the factory(whenorderedasaset).
Boththeemergencyreservelowbankpressuretransducerandtheemergencyreserveinusetransducermustbewiredtothemanifoldcircuit board as indicated by the labeling instruction (see page33). Remote master alarm signal and common wires must also beconnectedtothemanifoldcircuitboardas indicatedbythe labelinginstructionsonthebackofthecircuitboardcover.
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 19 of 36
Cylinder Replacement & Handling• Closeallcylindervalvesonthedepletedbank.
• SLOWLYloosenandremovethepigtailconnectionfromthedepletedcylinders.
• Removedepletedcylindersandreplaceprotectivecaps.
• Placeandsecurefullcylindersintopositionusingchains,beltsorcylinderstands.
• Remove protective cylinder caps from full replacementcylinders.Withthevalveoutletpointedawayfromallpeopleinthearea,slowlyopeneachcylindervalveslightlyforasplitsecondtoblowoutanydirtorcontaminantsthatmayhavebecomelodgedintothecylindervalve.
• Connectpigtailstocylindervalvesandtightenwithwrench.
• SLOWLYturneachcylindervalveuntileachcylinderisfullyon.
• Leaktesttheconnectionsusinganoxygenapprovedleaktestsolution.
• Observe the following conditions: The red (Empty) LED isextinguishedand theyellow (Ready)LED is illuminatedandthesecondaryinusealarmiscancelled.
• The manifold supply bank is now replenished andautomaticallyplacedin“reserve”.
Line Delivery Pressure Adjustment• Leavethemanifoldinfulloperationalstatus.
• Createa flowcondition in thedeliverypipingsystem. DISSdemandvalveshavebeenprovidedonthelineregulatorsforthispurpose. MatingDISS fittingsmaybeusedtocreateaflowofgaswithinthemanifoldcabinet.
• Openthemanifoldcabinetdoorandlocatethelinepressureregulators. Ballvalvesontheinletandoutletsidesofeachregulatordeterminewhichregulatoris“online”andwhichis“offline”.Note:whentheballvalvehandleisperpendicularto thepipeline, theball valve is closed. One line regulatorshouldbevalvedclosedandtheothervalvedopen.Thelineregulators on-line and off-line should be alternated everyothermonthtoensureeachisexcercised.
• Turn the T – bar handle clockwise to increase pressure orcounter-clockwisetodecreasepressure.Itmaybenecessarytousea3/4”open-endwrench, loosen the locknuton theadjustingscrew(onhighflowmodelsonly).
• After adjustment, retighten the locknut on the adjustingscrewandclosethecabinetdoor.
T-barhandle
DISSDemandValves
Ballvalves
Ballvalves
Line regulators
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 20 of 36
Programming AdjustmentsThemanifoldispre-programmedandtestedbeforeitisshipped.Youmay, however,wish tomodify some of the programming.Theunithasbeendesignedtoallowsomeprogrammingtobesimplyandsafelyalteredinthefield.Theaspectsoftheprogramwhichmaybealteredinclude:
Lowlinepressuresetpoint
Highlinepressuesetpoint
Unitsofmeasure(psig,barorkPa)
Calibratelinesensor
Displayscrolltime(seconds)
Applicationlogic(thisshouldonlybechangediftheunitisbeingconvertedtoanewapplication–inconferencewithafactorytechnician)
• To make any programming change, the cover must beremoved from the circuit board and the top #1 dip switchmust be switched from the RUN mode to the PROGRAMmode.
• Oncethe#1dipswitchhasbeenchangedfromtheRUNmodetothePROGRAMmode,thedisplayshouldlooklikethis
•Whileviewing thedisplayon the frontof thecabinetdoor,usetheNEXTorPREVIOUSbuttonstotogglethruthemenuchoices. When you find the item you wish to reprogram,use the UP or DOWN buttons to display the new settingdesiredand thenuse theENTERbutton tosavechanges totheprogramming.Note–iftheENTERbuttonisnotpressedforeachandeverychange,thatprogrammingchangewillnotbesaved.ThedisplaywilldisplaythewordSAVEDwhenyouhavesuccessfullysavedaprogrammingchange.
• Return thedip switch to theRUNposition and replace thecircuitboardcoverwhenyouarefinishedmakingchangestotheprogramming.
Programcontrolbuttons
Dipswitch#1Run/Program
Displaysshowingcommonpre-programmedalarmsetpoints
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 21 of 36
General Maintenance
Code Displayed Message Displayed Explanation
Error 01 Leftbanksensoroutofrange Thisconditionisactivatedwhentheleftsensor’srawreadingsareateitherextreme.Canbecausedbyadisconnected,wiredincorrectly,bad,orover-pressurizedsensor.
Error 02 Rightbanksensoroutofrange Thisconditionisactivatedwhentherightsensor’srawreadingsareateitherextreme.Canbecausedbyadisconnected,wiredincorrectly,bad,orover-pressurizedsensor.
Error 03 Intermediatepressureoutofrange Thisconditionisactivatedwhentheintermediatesensor’srawreadingsareateitherextreme.Canbecausedbyadisconnected,wiredincorrectly,bad,orover-pressurizedsensor.
Error 04 Emergencyreserveoutofrange Thisconditionisactivatedwhentheemergencysensor’srawreadingsareateitherextreme.Canbecausedbyadisconnected,wiredincorrectly,bad,orover-pressurizedsensor.
Error 07 Intermediatepressurehigh Messageisdisplayedwhenevertheintermediatepressureexceeds500psi.
Error 08 Emergencyreservepressurehigh Messageisdisplayedwheneverthehighpressureemergencyreservebankpressureexceeds3,000psi.
Error 09 Line sensor noise detected Messageisdisplayedifagasboarddetectsnoiseinthesignalfromit’sdigital sensor
Error 10 Linesensorfailedtorespond Messageisdisplayedifalinesensorisnotresponding.
Error 11 Line sensor is disconnected Messageisdisplayedwheneveralinesensorisdisconnected.
Error 12 Secondarysupplyleakdetected Messageisdisplayedwhenaleakisdetectedinthesecondarybank.
Error 13 Emergencyreserveleakdetected Messageisdisplayedwhenaleakisdetectedintheemergencyreservebank.
Error 14 Gastypemismatch Thiserrorcodeistriggeredbyamismatchingastypebetweenthelinesensoranduserselectedgastypeinsetupofthemanifoldcircuitboard.
Error Codes, Alarm Codes, & Information Codes
Interval Control Cabinet Headers & Pigtails
Daily Recordlineandbankpressures Observenitrousoxideandcarbondioxidesystemsforcylinderfrostingorsurfacecondensation.Shouldexcessivecondensationorfrostingoccuritmaybenecessarytoincreasemanifoldcapacity.
Monthly Checkregulators,compressionfittingsandvalvesforexternalleakage.Checkvalvesforclosureability.Alternatelineregulatorinuse(ifdual).
Inspectvalvesforproperclosure.Checkpigtailsforcleanliness,flexibility,wear,leakage,kinked,pinchedortwistedandthreaddamage.Replacedamagedpigtailsimmediately.Inspectheadercheckvalveoutletsforclosureability.
Annually Checkreliefvalvepressures.Checkregulatorseats.Tightenregulatorbonnets1to2degrees(outof360).
Every4years Replaceallpigtails
Every10years Rebuildorreplace:allregulators,PX-17-4003intermediatecheckvalves,PX-48-1008&PX-48-1009solenoidvalves,andDISSdemandcheckvalves.
Rebuildorreplacemastervalves.Replaceallcheckvalveoutlets.
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 22 of 36
Code Displayed Message Displayed Explanation
Alarm 01 Linepressurelow Messageisdisplayedandlowlinepressurerelayactivatedwheneverthelinepressureisbelowtheprogrammedlowlinepressurealarmsetpoint.
Alarm 02 Linepressurehigh Messageisdisplayedandhighlinerelayactivatedwheneverthelinepressureisabovetheprogrammedhighlinepressurealarmsetpoint(highlinepressurealarmistriggered).
Alarm 03 Secondarysupplyinuse Messageisdisplayedandsecondaryinuserelayactivatedwhenthemanifoldhasswitchedovertothesecondarybank.Clearswhentankisreplaced.
Alarm 04 Emergencyreserveinuse Messageisdisplayedandemergencyinuserelayactivatedwhenevertheintermediatepressureisbelowtheprogrammedemergencyinusepressurealarmsetpoint.(LLmodelsonly).
Alarm 05 Emergencyreservepressurelow Messageisdisplayedandemergencylowrelayactivatedwhenevertheemergencypressureisbelowtheprogrammedemergencyreservelowpressurealarmsetpoint.(LLmodelsonly).
Alarm 06 Rightbank/Secondarylow Messageisdisplayedandlowlinepressurerelayactivatedwhenevertherightbankpressureisbelow1,200psigfactorypre-setorpressuresetpointasre-programmedinthefield.(PLmodelsonly)
Info 01 Economizerinuse Messageisdisplayedwheneverthereadybankpressureexceedstheservicebankpressureby50psigormore.Thelogiccomparestheserviceandreadybankpressuresonceasecond.(LLmodelsonly).
XX% Remains (emergencyreserveonly-exceptforN2O&CO2services).Itcalculatesanddisplaysthepercentofgasremainingintheemergencyreservebank.
Definitions and clarificationsAlarm Code – AlarmconditionsperNFPA99CandZ7396.1guidelines.
Error Code – Messagesthatprovidediagnosticinformationtoassistinresolvingsystemproblems.
Information Codes – Messagesthatprovideinformationregardingtheoperationofthesystem.
Error Codes, Alarm Codes, & Information Codes
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 23 of 36
Item Part # Description
LineRegulators&RepairKits PX-68-0004R Lineregulatorstandardflow5-125psig
PX-68-0004RK Standardflowlineregulatorrepair/rebuildkit
PX-68-0002R Lineregulatorhighflow5-125psig
PX-68-0002RK Highflowlineregulatorrepair/rebuildkit5-125psig
PX-68-0001R Lineregulatorhighflow10-200psig
PX-68-0001RK Highflowlineregulatorrepair/rebuildkit10-250psig
CircuitBoard PX-35-1004R LL/PLseriesPLCboardwithsingletextdisplay
PowerSupply PX-35-2013R Powersupply
Transducers/Sensors PX-14-3001-12R 0-2,500psigtransducerwith12’cableforemergencyreservelow(bothLLandPLmodels)
PX-14-3001-5R 0-2,500psigtransducerwith15’cableforrightbanklow(PLmodelsonly)
PX-14-3002 0–500psigtransducerwith3’cableforleftorrightbanksandemergencyreserve in use
PX-14-3024 0-250psigtransducerwith1.5’cableN2
PX-14-3025 0-100psigtransducerwith1.5’cableOxygen
PX-14-3028 0-100psigtransducerwith1.5’cableMedAir
PX-14-3027 0-100psigtransducerwith1.5’cableN2O
PX-14-3028 0-100psigtransducerwith1.5’cableCO2
Solenoid Valves PX-48-1008R LeftsolenoidvalveforLL/PLseries
PX-48-1009R RightSolenoidvalveforLL/PLseries
CheckValve PX-17-4003R Intermediatecheckvalve1/2nptmalex1/2ODtube
Tubes&CompressionFittings PX-17-4012 CompressionSleeve1/2ODtube-glassfilledTeflon
PX-17-4005 CompressionNutfor17-4012
PX-Q1100-1 1/2ODcoppertubex7"
PX-17-4013 CompressionSleeve3/8ODtube-glassfilledTeflon
PX-17-4024 CompressionNutfor17-4013
Gauges PX-14-1018 0-4,000psig11/2"x1/8mnptcenterbackgauge
PX-14-1016 0-400psig2"x1/4mnptbottomportgauge
PX-14-1017 0-400psig11/2"x1/8mnptcenterbackgauge
PX-14-1009 0-300psig11/2"x1/8mnptcenterbackgauge
PX-14-1008 0-100psig11/2"x1/8mnptcenterbackgauge
Relief Valves PX-RV-22-075 75psigx½Mnptinletwithpipeawayadaptor
PX-RV-22-150 150psigx½Mnptinletwithpipeawayadaptor
PX-RV-22-250 250psigx½Mnptinletwithpipeawayadaptor
PX-RV-11-400 400psigx¼Mnptinletwithpipeawayadaptor
Pigtails PX-20-1001 36”(pre-bend)singlelooprigidcopperO2(w/ocheck)–CGA540
PX-20-1002 36”singlelooprigidcopperN2O–CGA326
PX-20-0002 24”FlexiblestainlessbraidedN2O-CGA326withcapturedfittings
PX-20-0003 24”FlexiblestainlessbraidedCO2–CGA320withcapturedfittings
PX-20-0004 24”FlexiblestainlessbraidedAIR–CGA346withcapturedfittings
PX-20-0005 24”FlexiblestainlessbraidedN2–CGA580withcapturedfittings
Replacement Parts & Accessories
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 24 of 36
Item Part # Description
Union PX-17-0169 Union3piece½”Mnptx½”Mnpt1”11½NPS
Master Valve PX-17-0256 MasterValve1/2"Fnptx1/2Fnpt
MasterValveRepairKit PX-GMV-1001RK Mastervalverebuildkit
Heaterelement PX-35-2001 CeramicHeater
Accessory PX-35-3012 Manifoldbuzzerkit
PigtailsforRWP&RSPModels PX-20-1001 24”singlelooprigidcopperO2–CGA540
PX-20-0001 24”FlexiblestainlessbraidedO2-CGA540
PX-20-1002 24”singlelooprigidcopperN2O–CGA326
PX-20-0002 24”FlexiblestainlessbraidedN2O-CGA326
PX-20-0003 24”FlexiblestainlessbraidedCO2–CGA320
PX-20-0004 24”FlexiblestainlessbraidedAIR–CGA346
PX-20-0005 24”FlexiblestainlessbraidedInert–CGA580
PigtailsforLL,TML&PLModels PX-20-2001 72”Flexible–O2–CGA540
PX-20-2002 72”Flexible–N2,Ar,He–CGA580
PX-20-2003 72”Flexible–CO2–CGA320
PX-20-2004 72”Flexible–N2O–CGA326
Union for Line Vent PX-17-0169 Union3piece½”Mnptx½”Mnpt1¼-14UNS
Union for Intermediate Vent PX-17-0271(2required)
Union3piece3/8”Mnptx½”Mnpt1¼-14UNS
Master Valve PX-17-0256 MasterValve1/2”Fnptx1/2Fnpt
MasterValveRepairKit PX-GMV-1001RK Mastervalverebuildkit
PX-35-3013 HighPressureReserveJumperKit
Heaterelement PX-35-2001 CeramicHeater
Accessory PX-35-3012 Manifoldbuzzerkit
Replacement Parts & Accessories (Continued)
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 25 of 36
Component Symptom Probable Cause Remedy or Check
Circuitboard Noindicatorlightsonfrontpanelilluminatewhenpowerisconnected.
Wiringconnection. Checkwiringconnections.
Powerinputoutofrange Checkelectricalpowersupplyoutputvoltages.
Badcircuitboard Replacepowersupplyorcircuitboard.
Redindicatorlightsareonbutbothbanksarefull
Mastervalveorcylindervalvesonbankareclosed.
OpenvalvesSLOWLY
Pigtailsareinstalledwithcheckvalvesinwrongdirection
Closecylindersandre-installpigtailsinproperflowdirection
Bankpressureisnotsufficientforlogicboardtoplaceitin“InUse”or“Ready”status(seeappendixEminimuminletpressurespage27)
Replacecylinderswithfullcylinders.Or,ifusingportablebulkvessels,openpressurebuildingvalveonvesselorreplaceportablebulkvesselwithhigherdeliverypressureportablebulkvessel
Errorcode(s)beingdisplayed
Loose or disconnected or brokenwire,mis-connectedwire,abadtransducer,acalibrationproblemoranover-pressuresituation.
Checkwiresforgoodandcorrectlocationconnectiontocircuitboard(SeeERRORCODESpg15)
Ifallwiresareconnectedproperlyandlocatedproperly–itmaybenecessarytoreplaceatransducer.
Entiremanifold Lossofcylindercontents Leakageinmanifoldcabinet,headersorpigtails.
Locateleakusingoxygencompatibleleaktestsolution,tighten,resealorreplaceleakingfitting(s)orpigtails.
Leakagethrumanifoldsolenoidvent / relief
Replacesolenoidvalve
Leakagearoundregulatorbonnet
Tightenregulatorbonnet
Regulatorwithbadseat Rebuildorreplaceregulator
Leakinggauge Replacegauge
Regulatorsettoohigh Setdeliverypressureperspecifications(seepage27)
Overpressureduetofailedregulator seat
Rebuildorreplaceregulator
Regulatorfreeze-up(N2OorCO2)/heaterfailure
Flowrateexceedsmanifolddesigncapacityorcylinderwithdrawlcapacity–addcylinders.
Repairheateroraddheaterandconsideraddingadditionalcylinders
Troubleshooting GuideNOTE: Troubleshootingandrepairsshouldbedonebyqualifiedpersonnelonly.
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 26 of 36
Component Symptom Probable Cause Remedy or Check
Lossofcylindercontents Bothbanksfeeding Leakingheader/pigtailconnection
Tightenfittingorre-tapewithOxygensafeTeflontape(ifnptfitting)andtighten.
Leakingintermediatecheckvalve
Replacecheckvalve
Leakingsolenoidvalve Replacesolenoidvalve
Inletpressuretocontrolcabinetistoolow
Verifythatminimuminletpressurerequirementsaremetperchartonpage31
Portablebulkvesselisventing Gasusageisnotsufficienttojustifyportablebulkreserve
Gasflowingthrutheeconomizercircuit
Thisisnormalwhenthereservebankpressureis50psiggreaterthantheservicebankpressure–nocorrectionneededtomanifoldcontrolcabinet.Mayconsiderreducingthenumberofliquidvesselsoneachbankifthereservebankismorethan35%depletedatthetimeitisplacedinservice.
Ifgasisflowingthrutheeconomizerwhenthereservebankpressureisnot50psiggreaterthantheservicebankpressure–theeconomizercheckvalveneedstobereplaced.
Manifoldisunabletosupportrequiredflow(N2OorCO2units)
Increasemanifoldflowcapacity(callfactoryforassistance)
System Changeoveroccurs,secondaryinusealarmistriggeredandthenclearsplacingemptyornearemptybankintoreserve
Manifoldisunabletosupportrequiredflow(N2OorCO2units)
Increasemanifoldflowcapacity(callfactoryforassistance)
Increasebanksize
Ifusingtwoormoreportablebulkvesselsperbankcurrently,connectpigtail(s)(nocheckvalve)fromventtoventofallvesselsonthesamebankandopentheventvalves.Thiswillequalizetheheadpressuresandutilizethecombinedvaporizationcapacity–notjustthevaporizationcapacityofthevesselwiththehighestdeliverysetpoint.
Troubleshooting Guide (Continued)
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 27 of 36
AC Alternating Current Anelectriccurrentthatreversesdirectionorpolarity atregularintervals.
Alarm Code
AlarmconditionsperNFPA99Cguidelines.
BAR Bar
Ameasurementoftheforceinacompressedgassystem.
1BAR=14.7psig(1atmosphere)
Check Valve
Avalvewhichoperatesmechanicallyandautomaticallytostopareverseflowofgas.
DC Direct Current
Anelectriccurrentthatflowsinonedirection.The currentcanbesteadyorpulse.
Economizer Circuit
Amechanicalpipingcircuitwhichallowsbuiltupreservegastobeusedinlowvolumeratherthanallowingthegastoventtoatmosphere.
Information Code
Messagesthatprovideinformationregardingtheoperationofthesystem.
KPa Kilopascals Ameasurementoftheforceinacompressedgas system. 1kPa=.14PSI
LED Light Emitting Diode Asemiconductordiodethatconvertsappliedvoltage tolight.
NFPA National Fire Protection Association TheNationalFireProtectionAssociationisan associationengagedinstandardsdevelopment.
NO Normally Open Anelectricalcircuitinwhichtheswitchisnormally open.Nocurrentflowsthroughthecircuitinnormal operation.Onlywhentheswitchisclosedistheflow ofcurrentstarted.
Anormallyopensolenoidvalveisonedesignedsothatitisopenwhenthereisnopowertothesolenoidandclosedwhenitisenergized.
NC Normally Closed Anelectricalcircuitinwhichtheswitchisnormally closed.Currentflowsthroughthecircuitinnormal operation.Onlywhentheswitchisopenedisthe flowofcurrentstopped.
PSI Pounds per Square Inch Ameasurementoftheforceinacompressedgas system. 1PSI=6.9kPa
Solenoid ValveAvalvethatisopenedorclosedelectromagnetically.
TransducerAdevicethatconvertspressureintoanelectricalsignal.
Transient SignalAnintermittentandbriefsignalthatquicklycorrectsandreturnsthealarmtoanormaloperatingmodebeforemonitoringpersonnelcansilencethealarm
V VoltageVoltageiselectricalpressureorforce.Onevoltisequaltothedifferenceofelectricalpotentialbetweentwopointsonaconductingwirecarryingaconstantcurrentofoneamperewhenthepowerdissipatedbetweenthepointsisonewatt.
Appendix A
Glossary of Terms
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 28 of 36
Appendix B
Technical SpecificationsMaximum Inlet Pressure: EmergencyReserve(bothLL&PLModels) 3000psig
Rightbank(secondary)modelPLonly 3,000psig
CabinetmodelsLL&PL: 400psig
Operating Ambient Temperature range:-20F(-29C)to125F(54.4C)
Storage Temperature:-20F(-29C)to185F(85C)
AC Input:120voltsAC-50-60Hz
Input Fuse: 5ampinputAClinefuseprotectstheinputwiringtopowersupply
Power Consumption: 45W(0.4ampsusing120VAC)maximumwithoutheaters
245W(2.1ampsusing120VAC)maximumwithheaters
Full Load Amps: .375withoutheaters 2.10withheaters
Pressure Measurement Accuracy: 0-100PSIGtransducer+/-1%offullscale–LinePressure–Oxygen,NitrousOxide,MedicalAir,CarbonDioxide
0-250PSIGtransducer+/-1%offullscale–LinePressure–Nitrogen
0500PSIGtransducer+/-2%offullscale–Bank&IntermediatePressuresmodelLLonly
0–2,500PSIGtransducer+/-2%offullscale–BankPressuresmodelCC,EmergencyReserveBankPressuremodelLL
Solenoid Valve: 24VDC–NormallyOpen(Valveopenswhende-energized)
DimensionsControl Cabinet: Dimensionsexcludinginlet&outletfittings 153/8”Wx25”Hx9¼”D
Dimensionsincludinginlet&outletfittings 17¼”Wx27”Hx9¼”D
Line PressureTransducers: Housingdimensions:1.25”Diameterx3.75”Lengthincludinginletfittings
WeatherproofControl Cabinet: Dimensionsexcludinginlet&outletfittings 17¼”W(cabinet)18¾:W(door)x263/4”Hx11”D
Dimensionsincludinginlet&outletfittings 20¼”Wx29”Hx11”D
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 29 of 36
Appendix C
Operational Pressure SpecificationsMinimum inlet pressure requirements for LL Manifold
Manifold delivery pressure Minimum inlet pressure Relief valve setting on vessel
50 135 235
80 135 235
170 250 350
Minimum inlet pressure requirements for PL Manifold
Manifold Delivery Pressure Minimum Inlet PressureLeft Bank
Regulator SettingRight Bank
Minimum Bank PressureRight Bank
50 135 150 1,200(factorypre-setrightbanklowpressurealarm)
80 300 250 1,200(factorypre-setrightbanklowpressurealarm)
170 300 250 1,200(factorypre-setrightbanklowpressurealarm)
Line Pressure Alarm Pressure Settings for LL Models
Normal Delivery Press Line Relief Setting High Line Press Set Point Low Line Press Set Point Secondary In Use Set Point
50 75 60 40 95bothbanks
80 150 96 64 95bothbanks
170 250 200 140 190bothbanks
Line Pressure Alarm Pressure Settings for PL Models
Normal Delivery Press Line Relief Setting High Line Press Set Point Low Line Press Set Point Secondary In Use Set Point
50 75 60 40 95bothbanks
80 150 96 64 95bothbanks
170 250 200 140 190bothbanks
Alarm Pressure Settings for LL & PL Models Emergency Reserve In Use & Emergency Reserve Low
Manifold Delivery PressureRecommended Emergency Reserve Regulator Delivery
Pressure Setting
Pre-programmed Emergency Reserve In Use Alarm Set Point
Pre-programmed Emergency Reserve Low Alarm Set Point
50 65 75 1200
80 70 80 1200
190 170 180 1200
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 30 of 36
Appendix D
Wiring Diagram
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 31 of 36
Appendix E
Wiring Diagram for Buzzer KitBuzzerKitPart#PX-35-3012
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 32 of 36
Powerex Limited WarrantyWarranty and Remedies. (a) Standard Period of Warranty – Parts and Labor. PowerexwarrantsandrepresentsallProductsshallbefreefromDefectsforthefirsttwelve(12)monthsfromthedateofshipmentbyPowerex.Duringsuchwarrantyperiod,PowerexshallbefullyliableforallDefectsintheProducts(the“ProductDefects”),i.e.,allcostsofrepairorreplacement,whichmayinclude“inandout”charges,solongastheProductsarelocatedintheUnitedStatesorCanada,andtheProductsarereasonablylocatedandaccessiblebyservicepersonnelforremoval.“Inandout”chargesincludethecostsofremovingaProductfrombuyer’sequipmentforrepairorreplacement.
(b) Additional Period of Warranty – Parts Only (No Labor). In addition to theabove,Powerexwarrants theproductsdescribedhereintobefreefromdefects inmaterialandworkmanshipfor forty-eight (48)monthsfromendofStandardPeriodofWarrantywiththeexceptionofanycomponentswhicharerecommendedtobereplacedinlessthansixtymonthsinourInstallation/Operationmanuals.WithinsaidperiodPowerexwillrepairorreplaceanypartorcomponentwhichisproventobedefectiveineithermaterialorworkmanship.Thiswarrantycoverspartsonly.Laborisnotincluded.Thiswarrantyisvalidonlywhentheproducthasbeenproperlyinstalledaccording toPowerex specifications,used in anormalmannerand servicedaccording to factory recommendations. Thiswarrantydoesnotcover failuresduetodamagewhichoccurs inshipmentor failureswhichresult fromaccidents,misuse,abuse,neglect,mishandling,alteration,misapplicationordamageduetoactsofnature.
(c) General. PowerexwarrantseachPowerexbrandedPipelineAccessory(collectively“Products”,individuallyeacha“Product”)tobe free fromdefects inmaterialandworkmanship (“Defects”)at thedateofshipment.EXCEPTASSETFORTHBELOW,NOOTHERWARRANTY,WHETHER EXPRESSOR IMPLIED, INCLUDINGANYWARRANTYOFMERCHANTABILITYOR FITNESS FOR A PARTICULARPURPOSE,SHALLEXISTINCONNECTIONWITHTHESALEORUSEOFSUCHPRODUCTS.TOTHEEXTENTPERMITTEDBYLAW,ANYANDALLIMPLIEDWARRANTIESAREEXCLUDED.AllwarrantyclaimsmustbemadeinwritinganddeliveredtoPowerexinaccordancewiththeproceduressetforthonitswebsite(www.powerexinc.com),orsuchclaimshallbebarred.Upontimelyreceiptofawarrantyclaim,PowerexshallinspecttheProductclaimedtohaveaDefect,andPowerexshallreplaceanyProductwhichitdeterminestohavehadaDefect;provided,however,thatPowerexmayelect,uponreturnoftheProduct,torefundtobuyeranypartofthepurchasepriceofsuchProductspaidtoPowerex.FreightforreturningProductstoPowerexforinspectionorforshippingwarrantypartsshallbepaidbybuyerwherepermittedbyapplicablelaw.Powerexisnotresponsibleforanyimportfees,taxes,duties,licensesorotherfeesimposedbyanygovernmentalauthorityupontheproduction,sale,shipmentand/oruseofProductscoveredhereunder.ThewarrantiesandremedieshereinarethesoleandexclusiveremedyforanybreachofwarrantyorforanyotherclaimbasedonanyDefect,ornon-performanceoftheProducts,whetherbaseduponcontract,warrantyornegligence.
(d) Coverage. ThewarrantyprovidedhereinappliestoPowerexpipelineproductsonly.
(e) Exceptions. Notwithstandinganythingtothecontraryherein,PowerexshallhavenowarrantyobligationswithrespecttoProducts:
(i)ThathavenotbeeninstalledinaccordancewithPowerex’swrittenspecificationsandinstructions;
(ii)ThathavenotbeenmaintainedinaccordancewithPowerex’swritteninstructions;
(iii) ThathavebeenmateriallymodifiedwithoutthepriorwrittenapprovalofPowerex;or
(iv)Thatexperiencefailuresresultingfromoperation,eitherintentionalorotherwise,inexcessofratedcapacitiesorinanotherwiseimpropermanner.
Thewarranty provided herein shall not apply to: (i) any defects arising from corrosion, abrasion, use of insoluble lubricants, ornegligentattendancetoorfaultyoperationoftheProducts;(ii)ordinarywearandtearoftheProducts;or(iii) defects arising from abnormalconditionsoftemperature,dirtorcorrosivematter;(iv)anyOEMcomponentwhichisshippedbyPowerexwiththeoriginalmanufacturer’swarranty,whichshallbethesoleapplicablewarrantyforsuchcomponent.
Limitation of Liability. NOTWITHSTANDINGANYTHINGTOTHECONTRARYHEREIN,TOTHEEXTENTALLOWABLEUNDERAPPLICABLELAW,UNDERNOCIRCUMSTANCESSHALLPOWEREXBELIABLEFORANY INCIDENTAL,CONSEQUENTAL,PUNITIVE,SPECULATIVEORINDIRECTLOSSESORDAMAGESWHATSOEVERARISINGOUTOFORINANYWAYRELATEDTOANYOFTHEPRODUCTSORGOODSSOLDORAGREEDTOBESOLDBYPOWEREXTOBUYER. TOTHEEXTENTALLOWABLEUNDERAPPLICABLELAW,POWEREX’SLIABILITY INALLEVENTSISLIMITEDTO,ANDSHALLNOTEXCEED,THEPURCHASEPRICEPAID.Intheeventofbreachofanywarrantyhereunder,Powerex’ssoleandexclusiveliabilityshallbeatitsoptioneithertorepairortoreplaceanydefectiveproduct,ortoacceptreturn,transportationprepaid,of suchproductand refund thepurchaseprice; ineithercaseprovided thatwrittennoticeof suchdefectisgiventoPowerexwithintwelve(12)monthsfromdateofshipmenttoBuyer,thattheproductisfoundbyPowerextohavebeendefectiveatthetimeofsuchshipment,thattheproducthasbeeninstalledand/oroperatedinaccordancewithPowerex’sinstructions,
Buyer’s purchase order is subject to the following conditions of sale:
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 33 of 36
thatnorepairs,alterationsorreplacementshavebeenmadebyotherswithoutPowerex’swrittenapproval,andthatBuyernotifiesPowerexinwritingwithinfifteen(15)daysafterthedefectbecomesapparentandpromptlyfurnishesfullparticularsinconnectiontherewith;andprovidedfurtherthatinnoeventshalltheaggregateliabilityofPowerexinconnectionwithbreachofanywarrantyorwarrantiesexceedthepurchasepricepaidfortheproductpurchasedhereunder.Powerexmay,atitsoption,requirethereturnofanyproduct,transportationanddutiesprepaid,toestablishanyclaimofdefectmadebyBuyer.Unlessotherwiseagreedinwriting(a) Powerexwillnotacceptandshallhavenoresponsibilityforproductsreturnedwithoutitspriorwrittenconsent,and(b)Powerexwillnotassumeanyexpenseorliabilityforrepairstoproductsmadeoutsideofitsplantbythirdparties.IntheeventPowerexelectstoreplaceadefectiveproduct,costsofinstallation,labor,service,andallothercoststoreplacetheproductshallbetheresponsibilityofBuyer.
Powerexshallnot,exceptassetforthabove,beotherwiseliabletoBuyerortoanypersonwhoshallpurchasefromBuyer,oruse,anyproductssuppliedhereunderfordamagesofanykind,including,butnotlimitedto,indirect,specialorconsequentialdamagesorlossofproductionoflossofprofitsresultingfromanycausewhatsoever,including,butnotlimitedto,anydelay,act,errororomissionofPowerex.Supplier’srepairorreplacementofanyProductshallnotextendtheperiodofanywarrantyofanyProduct.
Warranty Disclaimer.PowerexhasmadeadiligentefforttoillustrateanddescribetheProductsinitsliterature,includingitsPriceBook,accurately;however,suchillustrationsanddescriptionsareforthesolepurposeofidentification,anddonotexpressorimplyawarrantythattheProductsaremerchantable,orfitforaparticularpurpose,orthattheProductswillnecessarilyconformtotheillustrationsordescriptions.
Product Suitability.Manyjurisdictionshavecodesandregulationsgoverningsales,construction,installation,and/oruseofProductsforcertainpurposes,whichmayvaryfromthoseinneighboringareas.WhilePowerexattemptstoassurethatitsProductscomplywithsuchcodes,itcannotguaranteecompliance,andcannotberesponsibleforhowtheproductisinstalledorused.BeforepurchaseanduseofaProduct,pleasereviewtheProductapplications,andnationalandlocalcodesandregulations,andbesurethattheProduct,installation,andusewillcomplywiththem.
Claims.Anynon-warrantyclaimspertainingtotheProductsmustbefiledwithPowerexwithin(6)monthsoftheinvoicedate,ortheywillnotbehonored.Prices,discounts,andtermsaresubjecttochangewithoutnoticeorasstipulatedinspecificProductquotations.Powerexshallnotbeliableforanydelayorfailurearisingoutofactsofthepublicenemy,fire,flood,oranydisaster,labortrouble,riotordisorder,delayinthesupplyofmaterialsoranyothercause,whethersimilarordissimilar,beyondthecontrolofCompany.Allshipmentsarecarefullyinspectedandcountedbeforeleavingthefactory.PleaseinspectcarefullyanyreceiptofProductsnotinganydiscrepancyordamageonthecarrier’sfreightbillatthetimeofdelivery.Discrepanciesordamagewhichobviouslyoccurredintransitarethecarrier’sresponsibilityandrelatedclaimsshouldbemadepromptlydirectlytothecarrier.ReturnedProductswillnotbeacceptedwithoutpriorwrittenauthorizationbyPowerexanddeductionsfrominvoicesforshortageordamageclaimswillnotbeallowed.UNLESS OTHERWISE AGREED TO IN WRITING, THE TERMS AND CONDITIONS CONTAINED IN THIS LIMITED WARRANTY WILL CONTROL IN ANY TRANSACTION WITH POWEREX.Anydifferentorconflictingtermsasmayappearonanyorderformnoworlatersubmittedbythebuyerwillnotcontrol.AllordersaresubjecttoacceptancebyPowerex.
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 34 of 36
Notes
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 35 of 36
Notes
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
Installation & Operating Instructions forGenesys2 LL & PL Series Manifolds
Powerex • 150 Production Drive • Harrison, OH 45030 • USA(T) 1.888.769.7979 • (F) 513-367-3125 • www.powerexinc.com
IN594900AV • 02/2017Page 36 of 36
Notes
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________