User Programmable Fault Report

3
USER PR Address FlexAnalog name Unit 5728 Stator Diff Iad Amps 5732 Stator Diff Ibd Amps 5736 Stator Diff Icd Amps 5760 Sns Dir Power 1 Watts 5762 Sns Dir Power 2 Watts 6216 SRC 2 Ia Mag Amps 6218 SRC 2 Ia Angle Amps 6216 SRC 2 Ib Mag Amps 6218 SRC 2 Ib Angle Amps 6216 SRC 2 Ic Mag Amps 6218 SRC 2 Ic Angle Amps 6225 SRC 2 In Mag Amps 6227 SRC 2 In Angle Amps 6239 SRC 2 I_2 Mag Amps 6677 SRC 1 Vab Mag Volts 6679 SRC 1 Vab Angle Degrees 6680 SRC 1 Vbc Mag Volts 6682 SRC 1 Vbc Angle Degrees 6683 SRC 1 Vca Mag Volts 6685 SRC 1 Vca Angle Degrees 6686 SRC 1 Vx RMS Volts 7168 SRC 1 P Watts 7184 SRC 1 S VA 7193 SRC 1 Phase A PF 7194 SRC 1 Phase B PF 7195 SRC 1 Phase C PF 7552 SRC 1 Frequency Hz Note: We request GE to suggest if any other paramt

description

User Programmable Fault Report

Transcript of User Programmable Fault Report

USER PROGRAMMABLE FAULT REPORTAddress FlexAnalog name Unit

5728 Stator Diff Iad Amps5732 Stator Diff Ibd Amps5736 Stator Diff Icd Amps5760 Sns Dir Power 1 Watts5762 Sns Dir Power 2 Watts6216 SRC 2 Ia Mag Amps6218 SRC 2 Ia Angle Amps6216 SRC 2 Ib Mag Amps6218 SRC 2 Ib Angle Amps6216 SRC 2 Ic Mag Amps6218 SRC 2 Ic Angle Amps6225 SRC 2 In Mag Amps6227 SRC 2 In Angle Amps6239 SRC 2 I_2 Mag Amps6677 SRC 1 Vab Mag Volts6679 SRC 1 Vab Angle Degrees6680 SRC 1 Vbc Mag Volts6682 SRC 1 Vbc Angle Degrees6683 SRC 1 Vca Mag Volts6685 SRC 1 Vca Angle Degrees6686 SRC 1 Vx RMS Volts7168 SRC 1 P Watts7184 SRC 1 S VA7193 SRC 1 Phase A PF7194 SRC 1 Phase B PF7195 SRC 1 Phase C PF7552 SRC 1 Frequency Hz

Note:We request GE to suggest if any other paramter configuration is benifical for this report. The source may be modified as per actual design

USER PROGRAMMABLE FAULT REPORTDescriptionStator differential phase A current (Iad)Stator differential phase B current (Ibd)Stator differential phase C current (Icd)Sensitive directional power 1 actual valueSensitive directional power 2 actual valueSource 2 phase A current magnitudeSource 2 phase A current angleSource 2 phase B current magnitudeSource 2 phase B current angleSource 2 phase C current magnitudeSource 2 phase C current angleSource 2 neutral current magnitudeSource 2 neutral current angleSource 2 negative-sequence current magnitudeSource 1 phase AB voltage magnitudeSource 1 phase AB voltage angleSource 1 phase BC voltage magnitudeSource 1 phase BC voltage angleSource 1 phase CA voltage magnitudeSource 1 phase CA voltage angleSource 1 auxiliary voltage RMSSource 1 three-phase real powerSource 1 three-phase apparent powerSource 1 phase A power factorSource 1 phase B power factorSource 1 phase C power factorSource 1 frequency

We request GE to suggest if any other paramter configuration is benifical for this report. The source may be modified as per actual design

USER PROGRAMMABLE FAULT REPORTRemarks

If configuredAssuming source 2 on neutral side

DoDoDoDoDoDoDoDo

Line Side Open Delats connected PT

Assuming Aux VT on source 1

We request GE to suggest if any other paramter configuration is benifical for this report. The source may be modified as per actual design