UPSIDE - three-h.com

12
UPSIDE Assembly Instructions

Transcript of UPSIDE - three-h.com

Page 1: UPSIDE - three-h.com

UPSIDEAssembly Instructions

Page 2: UPSIDE - three-h.com

UPSIDE

Pg. 2

GENERAL ASSEMBLY INSTRUCTIONS · SIZES MAY VARY

1

2

DESK TOP AND LEGS

LEG SECURE

Place desk top good side down on a clean soft surface.

Place legs in position as shown.

Secure legs in place using 6 M6x16mm flat socket cap bolt provided for each leg.

UPSIDE

Pg. 1

GENERAL ASSEMBLY INSTRUCTIONS · SIZES MAY VARY

1

2

DESK TOP AND LEGS

LEG SECURE

Place desk top good side down on a clean soft surface.

Place legs in position as shown.

Secure legs in place using 6 M6x16mm flat socket cap bolt provided for each leg.

5/32" Allen Wrench (provided) (1)

Hardware Provided Tools Required

M6 x16mm Bolt (20)

UPSIDE

Pg. 1

GENERAL ASSEMBLY INSTRUCTIONS · SIZES MAY VARY

1

2

DESK TOP AND LEGS

LEG SECURE

Place desk top good side down on a clean soft surface.

Place legs in position as shown.

Secure legs in place using 6 M6x16mm flat socket cap bolt provided for each leg.

5/32" Allen Wrench (provided) (1)

Hardware Provided Tools Required

M6 x16mm Bolt (20)

Hardware Provided Tools Required

Page 3: UPSIDE - three-h.com

UPSIDE

Pg. 3

GENERAL ASSEMBLY INSTRUCTIONS · SIZES MAY VARY

3

4

5

LEG PLATES

POWER

INITIALIZATION

Place bottom leg plates in position and secure in place using 4 M6 x16mm flat socket cap bolts provided for each plate.

Once the legs are secured in place and the leg base plates are fasten securely, plug the power cords into the legs.

Turn desk to upright position and plug into to outlet. Test the desk by lowering it to the bottom and raising it to the top. If the system fails initialization may be required. (See page 8)

Page 4: UPSIDE - three-h.com

UPSIDE

Pg. 4

GENERAL ASSEMBLY INSTRUCTIONS · SIZES MAY VARY

Page 5 of 28

Safety instruction

General

Important information

Important information on LINAK® products can be found under the following headings:

Warning!Failure to comply with these instructions may result in accidents involving serious personal injury.

Failing to follow these instructions can result in the product being damaged or being destroyed.

Safe use of the system is possible only when the operating instructions are read completely and the instructions contained are strictly observed.

Failure to comply with instructions marked with the ”NOTE” symbol may result in serious damage to the system or one of its components.

It is important for everyone who is to connect, install, or use the systems to have the necessary information and access to this User Manual. Follow the instructions for mounting – risk of injury if these instructions are not followed.

The appliance is not intended for use by young children or infirm persons without supervision.

If there is visible damage on the product it must not be installed.

Note that during construction of applications, in which the actuator is to be fitted, there must be no possibility of personal injury, for example the squeezing of fingers or arms.

Assure free space for movement of application in both directions to avoid blockade.

Page 5: UPSIDE - three-h.com

UPSIDE

Pg. 5

GENERAL ASSEMBLY INSTRUCTIONS · SIZES MAY VARY

Page 6 of 28

Before installation, re-installation, or troubleshooting:• Stop the DL5/DL6• Pull out the mains plug.• Relieve the DL5/DL6 of any loads, which may be released during the work.

Before start-up:• Make sure that the system has been installed as instructed in this User Manual.• Make sure that the voltage of the control box is correct before the system is connected to the mains.• System connection. The individual parts must be connected before the control box is connected to the mains. See the User Manual for LINAK actuators, if necessary.

During operation• If the control box makes unusual noise or smells, switch off the mains voltage immediately.• Take care that the cables are not damaged.• Unplug the mains cable on mobile equipment before it is moved.• The products must only be used in an environment, that corresponds to their IP protection.

Misc.The actuator system has a sound level below 55dB(A) in typical applications.

Updated manuals and declarations can always be found here: www.linak.com/deskline

Page 6: UPSIDE - three-h.com

UPSIDE

Pg. 6

GENERAL ASSEMBLY INSTRUCTIONS · SIZES MAY VARY

Page 8 of 28

RepairsIn order to avoid the risk of malfunction, all DESKLINE® repairs must only be carried out by authorised LINAK workshops or repairers, as special tools must be used and special gaskets must be fitted. Lifting units under warranty must also be returned to authorised LINAK workshops.

Warning!If any of the DESKLINE® products are opened, there will be a risk of subsequent malfunction.

Warning!The DESKLINE® systems do not withstand cutting oil.

Page 7: UPSIDE - three-h.com

UPSIDE

Pg. 7

GENERAL ASSEMBLY INSTRUCTIONS · SIZES MAY VARY

Electrical connection of the DL5/DL6 system

The DESKLINE DL5/DL6 system is to be connected as shown on figure 4a (2 stage) or figure 4b (3 stage). Each DL5/Dl6 is the connected to the sockets on the control box by means of the motor cables, which have a 6-plug in each end. Figure 5.

Figure 4a

Figure 5

Figure 4b

Page 15 of 28

Figure 4

DL5/DL6 cable

DL5/DL6

Electrical connection of the DL5/DL6 system

The DESKLINE® DL5/DL6 system is to be connected as shown on figure 4. Each DL5/DL6 is to be connected to the sockets on the control box by means of the motor cables, which have an 6-pin plug in each end.

Please note that the control box must only be connected to the voltage stated on the label.

Finally, the mains cable is to be mounted and power switched on.

DP/WDPL

Mains cable

DL5/DL6

Hook for cable relief

Figure 5

CBD4/CBD5/CBD6 with earthThe CBD4/CBD5/CBD6 earth cable to be mounted on the desk construction (typically the top frame)in a way that ensures good electrical contact. The function of the earth cable is to earth the desk and ground static electricity. The earth connection does not protect other electrical products.

CBD4/CBD5 with mains cut-off (non ZERO models)If the power cable is damaged it has to be replaced by an authorized LINAK service centre to avoid any danger.

Page 8: UPSIDE - three-h.com

UPSIDE

Pg. 8

GENERAL ASSEMBLY INSTRUCTIONS · SIZES MAY VARY

Page 16 of 28

Initialisation of the DESKLINE DL5/DL6 parallel systems

The DESKLINE system is intialised by pressing the down button once or twice and holding it down until DL5/DL6 runs into end stop, it will then automatically run approx. 3 mm out again and hereafter slowly running in again. Only release the down button when the movement has completely stopped.

If the key is released before the sequence is completed then the initialisation is interupted and must be started again from the beginning.

It is sometimes necessary to press the down button twice to start the initialisation this is because the system can be in different modes when the initialisation starts.

Approx. 5 mm

The CBD5 and CBD6 can control DL5 and DL6 in 2 parallel while the CBD4 can control DL5 and DL6 in 2, 3, and 4 parallel so that the desk is always kept horizontal.

Page 17 of 28

Anti-Collision™The function (anti-collision) is an option for the standard CBD4/CBD5/CBD6 advanced/control box software 0077432 version 1.66 and later. A system with anti-collision can limit material damages on a desk if a collision with a solid object should occur.

Enabling the anti-collision To enable the anti-collision function a little plug called a dongle must be mounted in one of the 2 control ports. The function is only active when the dongle is mounted. – If you remove the dongle again you disable the function.

Method of operation When the DL/DB’s are running the CBD4/CBD5/CBD6 monitors the current consumption on each channel using a special algorithm. If the current consumption on one channel is increased more than a predefined slope, a collision is assumed and all channels are stopped immediately and all DL/DB’s will start to run in the opposite direction (approx. 50 mm). This return drive is done automatically and continues with or without any control key pressed (for max. 2.5 sec.).

The anti-collision sensitivity is different in upward and downward direction. Upwards the force is approx. 20 kg. Downwards the load will be approx. 40 kg + the load on the DL/DB (the desk + what is on top of the desk). The 40 kg are needed to activate the anti-collision function.

Situations where the anti-collision does not work There are situations where the anti-collision will not be activated. These situations are: • If the collision happens during the initialisation phase • If the collision happens within the first 1000 msec or after the control button has been released • If the collision happens between the floor and the table and the load on the desk + the weight of the legs are lower than 40 kg • If the collision happens over too long time, e.g. if the collision is with a soft object.

Page 9: UPSIDE - three-h.com

UPSIDE

Pg. 9

GENERAL ASSEMBLY INSTRUCTIONS · SIZES MAY VARY

DIAGNOSTIC CODES FOR CBD6S

DIAGNOSTIC CODES

NAME DESCRIPTIONCBD4/5/6

EQUIVALENTPOTENTIAL CAUSE

SOLUTION/ TROUBLESHOOTING

E01 Position LostThe desk has an unknown position

and needs to be initializedE01

• Position error• New desk leg added

• Initialize the system

E08 WatchdogIndicate that software failed to kick

watchdogE08 • Program fault

• Unplug mains cable for 15 sec.• Initialize the system• Replace control box

E09 LIN Collision Collisions detected on the LIN bus E49

• Key pressed on two or more connected handsets simultaneously • Multiple LINBUS devices activated simultaneously

• Check if another desk panel is connected and being activated • Unplug all but one desk panel and test system

E10 Power Fail Power fail happened E14• Mains cable pulled during driving• Internal fault

• Check mains cable is not caught and is allowed to freely travel

E11Channel

mismatchChange in number of actuators

since initializationE15

• Disconnection• Desk leg added

• Check motor cable connections and integrity • Change motor cable or Desk Leg• Initialize the system

E12 Position ErrorOne channel has position different

than othersE13 • Too much back drive occurred

• Move table to fully retracted position• Initialize the system

E13 Short CircuitShort circuit detected during

operationE10

• Squeezed motor cable• Short in motor

• Check motor cable connections• Isolate and replace motor cable• Isolate and replace desk leg

E16 Key ErrorIllegal keys pressed

(handled internally Dp1C)E16 • Hitting multiple buttons simultaneously • Check switch

E17Safety Miss-

ingLIN bus unit does not support

safety featureNEW

• DP1C/ DPF1C does not have up-to- date software

• Try DP with more recent software version (version printed on label)

E18Missing

Initialization Plug

A special service tool is required to change number of channels to the

systemNEW

• [BASELIFT ONLY]• Service tool missing from BASELIFT system when initializing

• Add service tool

E23 Ch1 Missing Channel 1 is detected missing E17• Disconnection• Faulty motor cable• Faulty motor leg

• Check motor cable connections and integrity • Change motor cable or Desk Leg• Initialize the system

E24 Ch2 Missing Channel 2 is detected missing E18• Disconnection• Faulty motor cable• Faulty motor leg

• Check motor cable connections and integrity • Change motor cable or Desk Leg• Initialize the system

E25 Ch3 Missing Channel 3 is detected missing E19• Disconnection• Faulty motor cable• Faulty motor leg

• Check motor cable connections and integrity • Change motor cable or Desk Leg• Initialize the system

E26 Ch4 Missing Channel 4 is detected missing E48• Disconnection• Faulty motor cable• Faulty motor leg

• Check motor cable connections and integrity • Change motor cable or Desk Leg• Initialize the system

E27 Ch5 Missing Channel 5 is detected missing NEW • [Reserved for future development] • [Reserved for future development]

E28 Ch6 Missing Channel 6 is detected missing NEW • [Reserved for future development] • [Reserved for future development]

E29 Ch1 TypeChannel 1 is not same type as

when initializedE20

• Change in desk leg type• Loose wire inside motor

• Check desk leg type • Change desk leg• Initialize the system

E30 Ch2 TypeChannel 2 is not same type as

when initializedE21

• Change in desk leg type• Loose wire inside motor

• Check desk leg type • Change desk leg• Initialize the system

E31 Ch3 TypeChannel 3 is not same type as

when initializedE22

• Change in desk leg type• Loose wire inside motor

• Check desk leg type • Change desk leg• Initialize the system

E32 Ch4 TypeChannel 4 is not same type as

when initializedE23

• Change in desk leg type• Loose wire inside motor

• Check desk leg type • Change desk leg• Initialize the system

Page 10: UPSIDE - three-h.com

UPSIDE

Pg. 10

GENERAL ASSEMBLY INSTRUCTIONS · SIZES MAY VARY

DIAGNOSTIC CODES FOR CBD6S

DIAGNOSTIC CODES

NAME DESCRIPTIONCBD4/5/6

EQUIVALENTPOTENTIAL CAUSE

SOLUTION/ TROUBLESHOOTING

E33 Ch5 TypeChannel 5 is not same type as

when initializedNEW • [Reserved for future development] • [Reserved for future development]

E34 Ch6 TypeChannel 6 is not same type as

when initializedNEW • [Reserved for future development] • [Reserved for future development]

E35 Ch1 Pulse FailChannel 1 had too many pulse

errorsE24

• Loose/ faulty cable• Hall sensor PCB

• Check motor cable connections and integrity • Change Desk Leg• Initialize the system

E36 Ch2 Pulse FailChannel 2 had too many pulse

errorsE25

• Loose/ faulty cable• Hall sensor PCB

• Check motor cable connections and integrity • Change Desk Leg• Initialize the system

E37 Ch3 Pulse FailChannel 3 had too many pulse

errorsE26

• Loose/ faulty cable• Hall sensor PCB

• Check motor cable connections and integrity • Change Desk Leg• Initialize the system

E38Ch4 Pulse

FailChannel 4 had too many pulse

errorsE27

• Loose/ faulty cable• Hall sensor PCB

• Check motor cable connections and integrity • Change Desk Leg• Initialize the system

E39 Ch5 Pulse FailChannel 5 had too many pulse

errorsNEW • [Reserved for future development] • [Reserved for future development]

E40Ch6 Pulse

FailChannel 6 had too many pulse

errorsNEW • [Reserved for future development] • [Reserved for future development]

E41Ch1

Overload UpOverload up occurred on Channel 1 E28

• Leg is overloaded• Hit obstruction• Reached end stop (before initialization at upper end-stop occurs)

• Remove obstruction• Remove load• Initialize if necessary

E42Ch2

Overload UpOverload up occurred on Channel 2 E29

• Leg is overloaded• Hit obstruction• Reached end stop (before initialization at upper end-stop occurs)

• Remove obstruction• Remove load• Initialize if necessary

E43Ch3

Overload UpOverload up occurred on Channel 3 E30

• Leg is overloaded• Hit obstruction• Reached end stop (before initialization at upper end-stop occurs)

• Remove obstruction• Remove load• Initialize if necessary

E44Ch4

Overload UpOverload up occurred on Channel 4 E31

• Leg is overloaded• Hit obstruction• Reached end stop (before initialization at upper end-stop occurs)

• Remove obstruction• Remove load• Initialize if necessary

E45Ch5

Overload UpOverload up occurred on Channel 5 NEW • [Reserved for future development] • [Reserved for future development]

E46Ch6

Overload UpOverload up occurred on Channel 6 NEW • [Reserved for future development] • [Reserved for future development]

E47Ch1 Overload

DWOverload down occurred on

channel 1E32 • Hit obstruction

• Remove obstruction• Initialize if necessary

E48Ch2 Overload

DWOverload down occurred on

channel 2E33 • Hit obstruction

• Remove obstruction• Initialize if necessary

E49Ch3 Overload

DWOverload down occurred on

Channel 3E34 • Hit obstruction

• Remove obstruction• Initialize if necessary

E50Ch4

Overload DWOverload down occurred on

Channel 4E35 • Hit obstruction

• Remove obstruction• Initialize if necessary

E51Ch5 Overload

DWOverload down occurred on

Channel 5NEW • [Reserved for future development] • [Reserved for future development]

Page 11: UPSIDE - three-h.com

UPSIDE

Pg. 11

GENERAL ASSEMBLY INSTRUCTIONS · SIZES MAY VARY

DIAGNOSTIC CODES FOR CBD6S

DIAGNOSTIC CODES

NAME DESCRIPTIONCBD4/5/6

EQUIVALENTPOTENTIAL CAUSE

SOLUTION/ TROUBLESHOOTING

E52Ch6

Overload DWOverload down occurred on

Channel 6NEW • [Reserved for future development] • [Reserved for future development]

E53 Ch1 Anti-ColAnti Collision triggered on

Channel 1 E36 • Hit obstruction

• Remove obstruction• Initialize if necessary

E54 Ch2 Anti-ColAnti Collision triggered on

Channel 2E37 • Hit obstruction

• Remove obstruction• Initialize if necessary

E55 Ch3 Anti-ColAnti Collision triggered on

Channel 3E38 • Hit obstruction

• Remove obstruction• Initialize if necessary

E56 Ch4 Anti-ColAnti Collision triggered on

Channel 4E39 • Hit obstruction

• Remove obstruction• Initialize if necessary

E57 Ch5 Anti-ColAnti Collision triggered on

Channel 5 E36 • [Reserved for future development] • [Reserved for future development]

E58 Ch6 Anti-ColAnti Collision triggered on

Channel 6E37 • [Reserved for future development] • [Reserved for future development]

E59Ch1 SLS/

PIEZOSafety limit switch activated on

Channel 1E40 • Hit obstruction

• Remove obstruction• Initialize if necessary

E60Ch2 SLS/

PIEZOSafety limit switch activated on

Channel 2E41 • Hit obstruction

• Remove obstruction• Initialize if necessary

E61Ch3 SLS/

PIEZOSafety limit switch activated on

Channel 3E42 • Hit obstruction

• Remove obstruction• Initialize if necessary

E62Ch4 SLS/

PIEZOSafety limit switch activated on

Channel 4E43 • Hit obstruction

• Remove obstruction• Initialize if necessary

E63Ch5 SLS/

PIEZOSafety limit switch activated on

Channel 5NEW • [Reserved for future development] • [Reserved for future development]

E64Ch6 SLS/

PIEZOSafety limit switch activated on

Channel 6NEW • [Reserved for future development] • [Reserved for future development]

E65 Ch1 Pulse DirPulses counted wrong direction in

Channel 1E44

• Motor poles are crossed• Hall sensor Cables are crossed

• Check motor cable connections and integrity• Initialize the system• Exchange desk leg

E66 Ch2 Pulse DirPulses counted wrong direction in

Channel 2E45

• Motor poles are crossed• Hall sensor Cables are crossed

• Check motor cable connections and integrity• Initialize the system• Exchange desk leg

E67 Ch3 Pulse DirPulses counted wrong direction in

Channel 3E46

• Motor poles are crossed• Hall sensor Cables are crossed

• Check motor cable connections and integrity• Initialize the system• Exchange desk leg

E68 Ch4 Pulse DirPulses counted wrong direction in

Channel 4E47

• Motor poles are crossed• Hall sensor Cables are crossed

• Check motor cable connections and integrity• Initialize the system• Exchange desk leg

E69 Ch5 Pulse DirPulses counted wrong direction in

Channel 5NEW • [Reserved for future development] • [Reserved for future development]

E70 Ch6 Pulse DirPulses counted wrong direction in

Channel 6NEW • [Reserved for future development] • [Reserved for future development]

E71 Ch1A ShortShort circuit detected on

Channel 1ANEW • [Reserved for use with Homeline system] • [Reserved for use with Homeline system]

E72 Ch1B ShortShort circuit detected on

Channel 1BNEW • [Reserved for use with Homeline system] • [Reserved for use with Homeline system]

Page 12: UPSIDE - three-h.com

Three H Furniture Systems Limited 156462 Clover Valley Rd. New Liskeard, ONCanada P0J 1P0

T. 1.800.767.5374F. 1.888.484.5786

[email protected] © 2017 Three H Furniture Systems Limited. All rights reserved.