UPS All Round

download UPS All Round

of 21

Transcript of UPS All Round

  • 8/13/2019 UPS All Round

    1/21

  • 8/13/2019 UPS All Round

    2/21

    1

    Contents

    UPS GG Series 2-3UNINTERRUPTED SAFETY FOR PC 400-600 VA

    UPS GG-Plus Series 4-5

    UNINTERRUPTED SAFETY FOR PC 800 -30 00 VA

    UPS IN Series 6-7UNINTERRUPTED SECURITY FOR PC, WORKSTATION AND SERVER 1000-3000 VA

    UPS S.11 Series 8-9ON LINE UPS SYSTEMS 700-3000 VA

    UPS S-DSP.11 Series 10-11ON LINE UPS SYSTEMS 3-10 KVA

    UPS S PLUS.31 Series 12-13ON LINE UPS SYSTEMS 10-20 KVA

    UPS P.33 Series 14-15ONLINE UPS SYSTEMS FOR NETWORKS AND COMPUTER CENTRES 10-200 KVA

    UPS P-EX.33 Series 16-17THE HIGH-PERFORMANCE ONLINE UPS SYSTEM 300-800 KVA

  • 8/13/2019 UPS All Round

    3/21

    2

    UNINTERRUPTED SAFETY FOR PC 400-600 VA

    The SUNLIGHT GG series is a line interactive uninterruptible

    power system. When utility input is normal, the UPS would

    provide surge protection and energy to charge the internal

    battery. If the utility input is abnormal, the UPS can supply ACpower to the load immediately.

    Microprocessor based control m inimizes the dependency on

    hardware. Beside this, it maximizes system flexibility and

    optimizes the assurance of reliability.

    Automatic frequency selection to m atch w ith

    utility power.

    Hi level battery charger to prolog battery's life

    and fully charge the battery.With actual overload protection both in line

    and battery mode.

    The AP types have communication feature.

    Line Interactive Technology 400VA to 600VA

    Microprocessor controlled Line Interactive

    Technology

    Boost and buck Automatic Voltage Regulation

    (AVR)

    Genius Battery Management (GBM)

    Short c ircuit and overload protection

    Lightning and surge protection

    Onl ine, Battery, Back up status LEDs

    Cold Start & Energy Saving features

    Genius Communication Port (GCP)

    and Remote Monitoring Softw are*

    Tel/Modem Internet surge protection*

    Programmable Remote Shutdown

    and Restart *

    Even t l og h is to ry *

    Compact size and user fr iendly operation

    * Available at AP Models only

    UPS GG SERIES

  • 8/13/2019 UPS All Round

    4/21

    3

    Technical Data

    MODEL

    INPUT

    Capacity

    Voltage

    Frequency

    OUTPUT

    Voltage (on battery)

    Frequency ( on battery)

    Voltage Regulation (AVR)

    Transfer Time

    BATTERY

    Battery Type

    Recharge Time

    Protection

    Back up time

    PROTECTION AND FILTERING

    Spike Protection

    Unit Input

    Overload Protection

    Short Circuit Protection

    ALARMS

    Alarms

    CONFORMANCE

    Surge

    Safety

    EMC

    Protection class

    ENVIRONMENT

    Operating Temperature

    Humidity

    Audible Noise at 1m

    COMMUNICATION

    RS-232 Interface

    PHYSICAL

    Net Weight (kg)

    Shipping Weight (kg)

    Dimensions (mm) WxDxH

    GG 400 A GG 500 A GG 600 A GG 400 AP GG 500 AP GG 600 AP

    400 500 600 400 500 600

    110V or 220V 25%

    50 or 60 Hz 10%

    Simulated Sinewave 110V or 220V 5%

    50 or 60 Hz 0.5%

    "AVR automatically increases output voltage 15% above input voltage if -9% to-25% of nominal

    AVR automatically decreases output voltage 13% below input voltage if + 9% to+ 25% of nominal"

    2 / 4 ms. including detection time

    Sealed, M aintenance-free lead acid

    4 hours ( to 90% of full capacity)

    Automatic self-test and discharge protection

    10 - 30 m inutes (depending on computer load)

    320 joule, 2ms

    Fuse for overload & short circuit protection

    Automatic shutdown if overload over 110% at 1 minute, and 130% at 3 sec.

    UPS output cut off immediately or input fuse protection

    Beeping sound for battery back up, battery low, overload status

    Meet IEEE 587 standard

    EN-50091-1

    EN-50091-2

    IP20

    0-40 C

    0-95% non-c ondensing

    < 4 0d BA

    N/A Bi-directional communication port

    4.0 5.9 6.1 5.7 6.6 6.8

    4.5 6.4 6.6 6.2 7.1 7.3

    100x265x137 100x330x137

  • 8/13/2019 UPS All Round

    5/21

    UNINTERRUPTED SAFETY FOR PC 800-3000 VA

    The UPS is a line interactive uninterruptible power system

    (UPS). When utility input is normal, the UPS would provide

    surge protection and energy to charge the internal battery. If

    the utility input is abnormal, the UPS can supply AC power tothe load immediately.

    Microprocessor based controls minimizes the depen-dency

    on hardware. Beside this, it maximizes system flexibility and

    optimizes the assurance of reliability.

    Automatic frequency selection to m atch w ith

    utility power.

    Hi level battery charger to prolog battery's life

    and fully charge the battery.With actual overload protection both in line and

    battery mode.

    Only AP types have communication feature.

    4

    Line Interactive Technology 800VA to 3000VA

    Microprocessor control led Line Interactive

    Technology

    Boost and buck Automatic Voltage Regulation (AVR)

    Genius Battery Management (GBM)

    Short c ircuit and overload protection

    Online, Battery, Back up status LEDs

    Lightning and surge protection

    Co ld Star t (DC power on)

    Energy Saving (UPS sleep mode)

    Compact size and user fr iendly operation

    Genius Communication Port (GCP)&

    Remote monitoring Softw are*

    Even t lo g h is to ry *

    Programmable Remote Shutdown and Restart*

    Netwo rk Pr otec tio n * *

    * Available at AP Models only

    * * Available above 1600VA models

    UPS GG-PLUS SERIES

  • 8/13/2019 UPS All Round

    6/21

    Technical Data

    5

    MODEL

    INPUT

    Capacity

    Voltage

    Frequency

    OUTPUT

    Voltage (on battery)

    Frequency ( on battery)

    Voltage Regulation (AVR)

    Transfer Time

    BATTERY

    Battery Type

    Recharge Time

    Protection

    Back up time

    PROTECTION AND FILTERING

    Spike Protection

    Unit Input

    Overload Protection

    Short Circuit Protection

    ALARMS

    Alarms

    CONFORMANCE

    Surge

    Safety

    EMC

    Protection class

    ENVIRONMENT

    Operating Temperature

    Humidity

    Audible Noise at 1m

    COMMUNICATION

    Communication

    PHYSICAL

    Net Weight (kg)

    Shipping Weight (kg)

    Dimensions (mm) WxDxH

    GG 800 A/AP GG 100 0A/AP GG 120 0A/AP GG 160 0AP GG 200 0AP GG 240 0AP GG 300 0AP

    800 1000 1200 1600 2000 2400 3000

    110V or 220V 25%

    50 or 60 Hz 5%

    Simulated Sinewave 110V or 220V 5%

    50 or 60 Hz 0.5%

    "AVR automatically increase output voltage 15% above input voltage if -9% to-25% of nominal

    AVR automatically decrease output voltage 13% below input voltage if + 9% to+ 25% of nominal"

    2 / 4 m s. including detection time

    Sealed, M aintenance-free lead acid

    8 hours ( to 90% of full capacity)

    Automatic self-test & discharge protection

    10 - 30 m inutes (depending on computer load)

    320 joule, 2ms

    Fuse for overload & short circuit protection

    Automatic shutdown if overload over 110% at 60 secs, and 130% at 3 sec.

    UPS output cut off immediately or input fuse protection

    Beeping sound for battery back up, battery low, overload status

    Meet IEEE 587 standard

    EN 50091-1

    EN 50091-2

    IP20

    0-40 C

    0-95% non-condensing

    < 48dBA < 52dBA

    Bi-directional communication port available at AP models only

    13.9 16,8 26,2 28,8

    14.8 18 28 30,1

    125x390x200 175 x 460 x 235

  • 8/13/2019 UPS All Round

    7/21

    6

    UNINTERRUPTED SECURITY FOR PC, WORKSTATION AND SERVER 1000-3000 VA

    SUNLIGHT IN series is a line interactive UPS with the s tate of the

    art technology and powerful functions. The Line interactive UPS,

    with AVR function, allows input voltage range from 75% to

    125%, including on line voltage boost-up and buck dow n, idealprotection equipment for c ritical connected loads.

    Microprocessor based controls, w ill minimizes the dependency

    on hardware. Beside this, it maximizes system flexibility and

    optimizes the assurance of reliability.

    Automatic frequency selection to m atch w ith utilty pow er.

    Hi level battery charger to prolong battery's life and fully chargethe battery. With actual overload protection both in line and

    battery mode.

    Line Interactive Technology

    1000VA/2000VA/3000VA

    Pure Sinewave Output UPS

    Pure sinewave output for any crit ical load

    Boost and buck Automatic Voltage Regulation

    Over load protec tion

    Shor t ci rcuit p ro tec ti on

    Sealed, Maintenace free lead acid battery group

    Compact size, l ight weight&low noise

    Extended back up time with battery pack

    Discharge p ro tec ti on

    Sh or t rec har ge tim e

    Fault alarm s

    State w arnings

    Optional software features

    UPS IN SERIES

  • 8/13/2019 UPS All Round

    8/21

    IN 1000 IN 2000 IN 3000

    1000 VA 2000 VA 3000 VA

    2 20 V 2 5%

    50 or 60Hz 5%

    pure sinewave 220V 5%

    50 or 60 Hz 0.5%

    AVR automatically increase output voltage 15% above input voltage if -9% to 25% of nominal.

    AVR decrease output voltage 15% below input voltage if + 9% to + 25% of nominal

    2/4 ms.

    320 joule, 2 ms.

    UPS automatic shutdown if overload exceeds 110% of nom inal at 20sec. and 125% at 2 sec.

    Fuse for overload & short circuit protection

    2x7Ah12V 2x12Ah12V *8 x12Ah12V 4x7Ah12V *1 6x7Ah12V 4x7Ah12V * 16x7Ah12V

    4 6 * 6 4 * 8 4 * 8

    Automatic self-test & discharge protection, replace battery indicator

    in in in in in in in

    1000 Mini 1000 1000XL 2000 2000XL 3000 3000XL

    Sample device Back up Time (m in) Nominal

    Nom inal 10 18 90 20 100 20 100

    Nom inal - - - 10 50 10 50

    Nominal - - - - - 5 25

    TV 90 150 720 180 780 180 780

    Combi 40 78 420 80 480 80 480

    PC 30 66 300 60 360 60 360

    19 22 22+ * 31 31 31+ * 37 32 3 2+ * 37

    135 135 2x135 135 2x135 135 2x135

    430 430 2x430 470 2x470 470 2x470

    390 390 2x390 390 2x390 39 2x390

    < 40 dBA (1m from surface) < 45 dBA (1m from surface)

    7

    Technical Data

    MODEL

    INPUT

    Capacity

    Voltage

    Frequency

    OUTPUT

    Voltage (on battery)

    Frequency ( on battery)

    Voltage Regulation (AVR)

    Transfer Time

    PROTECTION AND FILTERING

    Spike Protection

    Overload Protection

    Unit input

    BATTERY

    Battery Type

    Recharge Time

    Protection

    UPS Type

    Power

    (600 W)

    (1200 W)

    (1800 W)

    (80 W)

    (150 W)

    (200 W)

    PHYSICAL

    PHYSICAL

    Dimension Width

    Depth

    Height

    ENVIRONMENT

    Audible Noice

    (* ) Battery Pack

  • 8/13/2019 UPS All Round

    9/21

    SUNLIGHT S.11 series is truly an advanced "On-Line"

    uninterruptible power system, producing reliable and pure sine

    wave power to users' equipment. This could include critical

    medical instruments, computers, telecom munication systems,and industrial automatic equipment. Under power normal

    condition, th e On-Line design enables the system to adjust and

    filter power fluctuations co ntinuously and automatically. In case

    of pow er failure, it can provide imm ediate back-up pow er from

    the batteries without any interruption. When overload or UPS

    malfunction, the system w ill automatically transfer into bypass

    mode and keep supplying output equipment with utility power;If overload situation releases, it will automatically transfer back

    to inverter mode, then malfunction is resolved by restarting the

    UPS.

    True On-Line ' 'Double Conversion '' Technology

    1 Phase in - 1 Phase out 0,7 to 3 KVA

    Double CPU Cont ro l

    True On Line double conversion technology

    Pure sinewave output less than 3 %THD

    Wide input vo ltage range 27 % of nominal

    Smart RS-232 communication port

    SNMP management capabil ity

    Management sof tware compatible

    Power fac to r co rrec tion

    Overload & short c ircuit protection

    Cold Star t ( DC power on )

    Extended back up time with battery pack

    Genius battery management ( GBM )

    Compact size, l ight weight & low noise

    8

    UPS S.11 SERIES

    ON LINE UPS SYSTEMS 700- 300 0 VA

  • 8/13/2019 UPS All Round

    10/21

    9

    S.11 / 700 S.11 / 1000 S.11 / 1500 S.11 / 2000 S.11 / 3000

    0,7 1 1,5 2 3

    110V or 220V 27%

    50/60 Hz 3 Hz

    100V/110V/120V or 200V / 220V / 230V / 240V

    %2

    50/60 Hz 0.5%(Auto detection)

    0 ,5 %

    < 3% ( for linear loads )

    105% for 10 seconds, 130% 10% for 300ms

    24V 36V 48V 72V 96V

    7 min. 7 min. 5 min.

    20 min. 20 min. 15 min.

    Maintenance-free sealed lead acid

    8 hours(to 90% of full capacity)

    > 85%

    > 90%

    0m s

    < 45dBA < 50dBA

    line input (green), inverter output (green), bypass (yellow), fault (red)

    4 green, 1 red LED and red bar LEDs indicate low capacity

    4 green, 1 red LED and red bar LEDs indicate overload condition

    Warning beep every 4 seconds

    Warning beep every 1 seconds

    Continuous beeping sound

    Provide power management&diagnostic functions including power status

    battery low schedule UPS ON/OFF, battery/load level display and more

    Compatible with Windows 95/98 NT, Novel, UNIX other popular systems

    10C - 40C

    20% - 90%

    12.5 15 18 32 36

    145x400x220 192x455x380

    MODEL

    INPUT

    Power(kVA)

    Voltage

    Frequency

    OUTPUT

    Voltage

    Voltage Regulation

    Frequency

    Frequency Regulation

    Harmonic Distortion

    Overload Capacity

    BATTERY

    DC Voltage

    Back Up Time Full Load

    Half Load

    Battery Type

    Recharge Time

    EFFICIENCY

    Whole

    Inverter

    TRANSFER

    Power Failure&Recovery

    NOISE LEVEL

    1m Distance

    LED INDICATORS

    Status

    Battery Capacity

    Load Level

    ALARMS

    Load On Battery

    Battery Low

    UPS Fault

    COMMUNICATION

    RS-232 Interface&

    Dry Contact Signal

    ENVIRONMENT

    Temparature

    Humidity

    PHYSICAL

    Net Weight (kg)

    Dimensions(mm) WxDxH

    Technical Data

  • 8/13/2019 UPS All Round

    11/21

    ON LINE UPS SYSTEMS 3-10 KVA

    SUNLIGHT UPS S-DSP.11 series in the "On-Line" mode

    produces sinusoidal output voltage with constant frequency

    and amplitude. This output voltage is not affected by

    irregularities produced in the mains. This way the life time ofyour sensitive loads (like PC, Network server etc) is

    extended. On the other hand the kind of current drawn from

    the mains by the UPS is sinusoidal with a power factor close

    to 1. This avoids, excessive reactive energy consumption or

    warming up of the insulated transformers or generatorsconnected at the UPS's input and the building's mains.

    10

    True On-Line ' ' Double Conversion '' Technology

    1 Phase in, 1 Phase out 3 to 10Kva

    On-line double conversion technology

    Real Digital Signal Processor ( DSP ) controlled IGBT

    technology

    Wide input voltage range ( 80 V - 280 V )

    Increased Power Factor ( > 0,98 )

    Info Charger; Intelligent temperature controlled battery

    charging extends battery life

    Low Total Harmonic Distortion (THD) Level

    Sm all dim ens io ns

    Smart Fan speed regulat ion

    Redundan t operat ion

    Atrificial intelligence algorithms to improve reliability

    and technical performance

    LCD Display

    Advanced communication possibil ity v ia RS - 232

    and relay interface

    Management and monitoring software available

    for all operating systems

    SNM P Support

    UPS S-DSP.11 SERIES

  • 8/13/2019 UPS All Round

    12/21

    Technical Data

    11

    TYPE

    Tower Model

    Power (Kva)

    INPUT

    Nominal Voltage

    Minimum VoltageMinimum Voltage ( at full load )

    Maximum Voltage

    Frequency

    Power Factor

    Input Current Harmonics

    OUTPUT

    Nominal Voltage

    Wave Form

    Total Harmonic Distortion

    Frequency

    Frequency Tolerance (li ne

    synchronized)Voltage Regulation (Static)

    Crest Factor

    Overload (on mains)

    Overload (on battery)

    Total Efficiency

    Greenmode efficiency

    BATTERY

    Type

    Number of Batteries

    Back up time ( at nominal load )

    Recharging Time

    Discharge Current WaveOthers

    BY-PASS

    Voltage Tolerance

    Frequency Tolerance

    Transfer Time

    PROTECTION

    Overload Protection

    Short Circuit Protection

    Other Protection

    COMMUNICATION INTERFACE

    RS 232

    Free ContactENVIRONMENT

    Temperature

    Proposed Temp. to extend battery life

    Humidity

    Audible Noise AT 1 m

    PHYSICAL SPECIFICATIONS

    Tower Type

    Net Weight( without battery )

    Dimensions(mm) (WxDxH)

    STANDARDS

    Safety

    EMC

    Protection Class

    DSP03 DSP05 DSP06 DSP075 DSP10

    3 5 6 7,5 10

    220V

    80V150V 176V

    280V

    45-65 Hz

    > 0 ,9 8 %

    < 6 %

    220V (adjustable)

    Sinus

    < 2%

    50Hz or 60Hz (adjustable)

    0,005 %1%

    3

    > 30s (at 150 % load)

    > 30s (at 150 % load)

    > 91%

    > 97%

    Maintenance Free Dry Type

    14 20 24

    Internal up to 35 minutes Internal up to 22 minutes Internal up to 15 minutes Internal up to 10 minutes External

    < 4 h / 6 h

    < 10%Heat compensated battery charging artificial Intelligence based capacity. Cut off Voltage according to Changing Load. Battery bar independent of load

    10% (adjustable)

    3Hz (adjustable)

    0 m s

    Bypass transfer time is calculated by simulating a temperature related model of a fuse

    Acts as the ideal current source during the short circuit time

    Against Excessive ( Heat,Voltage,Current) Intense Battery disc harge

    Isolated according to EN60950

    Isolated according to EN60950

    0 - 40 oC

    20 - 25 oC

    < 95%

    50 dB

    45kg 55kg

    270x650x700

    EN50091-1

    EN50091-2IP 20

  • 8/13/2019 UPS All Round

    13/21

    SUNLIGHT S-PLUS.31 series "On-Line" on the mode

    produces sinusoidal output voltage with constant frequency

    and amplitude. This output voltage is not affected by

    irregularities produced in the mains. This way, the life time ofyour sensitive loads (like PC, Network server etc) is

    extended.

    On the other hand the kind of current drawn from the mains by

    the UPS is sinusoidal with a power factor close to 1. This

    avoids, excessive reactive energy consumption or warming

    up of the insulated transformers or generators connected atthe UPS's input and the building's mains.

    True On - Line Double Conversation Technology

    10 to 20 k VA 3 Phase in, 1 Phase out

    On - Line "Double conversion"technology

    Real Digital Signal Processor (DSP) controlled,

    IGBT tec hno lo gy

    Wide input voltage range (140V - 480V)

    Increased Power Factor (> 0,97)

    Info Charger; Intelligent temperature controlled

    battery charging extends battery life

    Smart fan speed regulat ion

    Small Dimensions

    Artificial intell igence algorithms to improve

    reliability and technical performance

    M anual By pass

    LCD display

    RS 232 and relay in ter face

    Management and montoring software available

    for all operating systems and SNMP support

    12

    UPS S-PLUS.31 SERIES

    ONLINE UPS SYSTEMS FOR NETWORKS AND COMPUTER CENTRES 10-20 KVA

  • 8/13/2019 UPS All Round

    14/21

    Technical Data

    13

    TYPE

    Power

    INPUT

    Nominal Voltage

    Minimum Voltage

    Minimum Voltage ( at full load )

    Maximum Voltage

    Frequency

    Nominal Current

    Maximum Current

    Power Factor

    BY-PASS

    Voltage Tolerance

    Frequency Tolerance

    Transfer Time

    BATTERY

    Type

    Number of Batteries

    Recharging Time

    Discharge Current Wave

    Others

    OUTPUT

    Nominal Voltage

    Wave Form

    Total Harmonic Distortion

    Frequency

    Voltage Regulation (Static)

    Crest Factor

    Overload

    Total Efficiency

    PROTECTION

    Protections

    COMMUNICATION INTERFACE

    RS 232

    Free Contact

    ENVIRONMENT

    Temperature

    Suggested Temp. to extend

    battery life

    Humidity

    Acoustic Noise

    PHYSICAL SPECIFICATIONS

    Net Weight( without battery )

    Dimensions(mm) (WxDxH)

    STANDARDS

    Safety

    EMC

    Protection Class

    S-PLUS 3110 S-PLUS 3115 S-PLUS 3120

    10kVA 15kVA 20kVA

    380 V / 400V / 415V 3Phase, N

    140V 3Phase, N

    260V 3Phase, N

    480V 3Phase, N

    50 - 60Hz (45 to 65 Hz)

    11.8 A / phase 17,4 A / phase 23,3 A / phase

    36 A peak / phase 53 A peak / phase 71 A peak / phase

    > 0 ,9 7

    10% (adjustable)

    3Hz (adjustable)

    0 m s

    Maintenance Free Dry Type

    24 32 32

    < 4 h

    < 10%

    Heat compensated battery chanrging

    210V / 220V / 2 30V (adjustable)

    Sinus

    < 3%

    50Hz or 60Hz (adjustable)

    1%

    3

    > 30s (at 150 % load)

    > 91%

    Overload Protection, Short Cicuit Protection, High Temperature, Over Voltage, Over Current

    Isolated according to EN60950

    Isolated according to EN60950

    0 - 40C

    20 - 25C

    < 95%

    < 55dB, 1 m

    55kg 180kg 185kg

    270x650x700 430x820x1170 430x820x1170

    EN50091-1

    EN50091-2

    IP 20

  • 8/13/2019 UPS All Round

    15/21

    ONLINE UPS SYSTEMS FOR NETWORKS AND COMPUTER CENTRES 10-200 KVA

    True on line double conversion technology of SUNLIGHT P.33

    Series ensures trouble free, reliable operation valuable

    equipment and critical load by maintaining precise and pure

    sine wave output.Integrated w ith the latest and mos t efficient generation of IGBT

    technology provides high current capability and protects the

    system against high instantaneous overload, improving the

    reliability. In addition, the implementation of advanced

    technology such as surface mounted devices SMD has

    reduced the number and the surface of electronic boards.

    The reduction in the numbers of components increases its

    imm unity to electromagnetic disturbances.

    SUNLIGHT P.33 UPS system is designed to provide the most

    suitable features and characteristic s:

    wide voltage tolerances,

    high performance w hen supplying non-linear loads, parallel systems for an increased pow er upgrading

    or redundancy,

    high eff ic iency,

    compact dimensions,

    low acoustic noise,

    reliability of the battery ensured by Info-Charger.

    14

    Uninterruptible Power Systems

    True On-Line Technology 3 Phase in - 3 Phase out / 10 to 200kVA

    True on-line double conversion technology

    State of the art IGBT and PWM technology

    Evolution and redundancy guaranteed by Parallel Systems

    Reliability of the battery ensured by Info-Charger

    Fail safe battery back up

    Synchronization with external source

    Bui lt- in maintenance and static by pass

    Galvanic isolation and/or modification for special voltages

    Comprehensive communication with computer

    and network systems and SNMP solutions

    Communication with building management systems

    Expandable and variable battery blocks

    THCDL and 12 pulse rectif ier options

    Low instal lation and operating cost

    UPS P.33 SERIES

  • 8/13/2019 UPS All Round

    16/21

    P. 33 10 P.3 3 15 P.3 32 0 P. 33 2 0 P.3 33 0 P. 33 4 0 P. 33 60 P. 33 8 0 P .3 3 10 0 P. 33 1 20 P.3 32 00

    10 15 20 30 40 60 80 100 120 160 200

    0.8 lagging

    380V / 400V / 415V 3 Phase

    15%

    50 / 60Hz (45 to 65 Hz)

    10%

    380V / 400V / 415V 3Phase

    + - 1%

    + - 5%

    < 3%

    < 5%

    3

    50 or 60 Hz

    0 .2 %

    10min.

    1min.

    90%

    RS232 and Dry Contact, standard and isolated according EN60950

    2 40 2 55 27 0 2 85 49 0 5 70 6 00 75 0 8 10 97 0 1 17 0

    240x680x870 490x680x1200 550x800x1400 700x800x1450 1100x800x1650

    < 55dBA < 60dBA 63 to 66dBA

    0-40C

    0-95%

    EN 50091-1 (safety), EN 50091 -2 ( EMC),IEC 62040-3 ( c lass VFI), IP20

    Battery Cabinet, Parallel Kit, SNMP Kit, Separated Mains Input, Remote Control Panel, Filters, 12 pulse rectifier,

    Additional Battery Charger, Battery Protection, Temperature Compensation, Teleservice, Modem, RS485, Eco-Mode

    Technical Data

    15

    MODEL

    Output Power kVA

    Power factor

    INPUT

    Voltage

    Tolerance

    Frequency

    Tolerance

    OUTPUT

    Voltage

    Tolerance (static condition)

    Tolerance (dynamic condition)

    Harmonic Distortion rate

    on lineer load

    Harmonic Distortion rate

    on non-lineer load

    Crest factor

    Frequency

    Frequency Tolerance

    Overload

    100% - 125% load

    125% - 150% load

    Overall Efficiency

    COMMUNICATION

    Interface

    PHYSICAL

    Weight without battery (kg)

    Dimensions(mm) WxDxH

    ENVIRONMENT

    Audible Noise

    Operating Temperature

    "Relative Humidity

    Standards

    OPTIONS

  • 8/13/2019 UPS All Round

    17/21

    16

    True on-line, double conversion technology of SUNLIGHT P-

    EX.33 ensures trouble free, reliable operation for critical load

    by maintaining precise and pure sine wave output. Rugged

    IGBT technology provides high current capability and protectsthe system against high instantaneous overload, which

    improves the reliability. The IGBT power transistor, combined

    with numeric command by micro controllers, meets the most

    demanding requirements:

    supply non-linear loads

    improve the reliability of both the UPS and its battery facilitate operation and serviceability

    reduce size and noise level

    True On-Line Technology 3 Phase in - 3 Phase out

    300 to 8 00kVA

    True on-line double conversion technology

    with high efficiency

    State of the art IGBT & PWM technology

    Evolut ion and redundancy guaranteed by

    Parallel Systems ( up to 6 units)

    Buil t- in maintenance and automatic by pass

    Galvanic isolat ion and/or modif ication for

    special voltages

    Communicat ion with computer & network

    systems and SNMP so lutions

    Expandable and variable battery blocks

    12 pulse rect if ier option

    Continuous monitoring via Tele Service

    UPS P-EX.33 SERIES

    THE HIGH-PERFORMANCE ONLINE UPS SYSTEM 300-800 KVA

  • 8/13/2019 UPS All Round

    18/21

    Technical Data

    P- EX.3 3 / 3 00 P -EX.3 3 / 4 00 P -EX.3 3 / 5 00 P- EX. 33 / 6 0 0 P- EX. 33 / 8 0 0

    300 400 500 600 800

    0.85 lagging

    380V / 400V / 415V 3 Phase

    15%

    50 / 60Hz

    10%

    380V / 400V / 415V 3Phase

    < 0 .5 %

    5%

    < 1 .5 %

    < 5%

    up to 3

    50 or 60 Hz

    0 .2 %

    10min.

    1min.

    100 ms

    100 %

    up to 94%

    1800 2000 4400 4500 5000

    1600 x 800 x 1920 4300 x 800 x 1920

    68 to 75 dBA

    EN 50091 - IEC 146 - 4

    Battery Cabinet, Parallel Redundancy,SNMP Interface,Isolation Transform er ,Remote Signalisation and Control

    Unit,Communication Software,Remote Signalisation Interface,Common By-Pass for Parallel Systems,Galvanic

    Isolation,12 Pulse Rectifier,Serial Port Interface,Dry Contact Interface

    MODEL

    Output Power kVA

    Power factor

    INPUT

    Voltage

    Tolerance

    Frequency

    Tolerance

    OUTPUT

    Voltage

    Tolerance (static condition)

    Tolerance (dynamic condition)

    Harmonic Distortion rate

    on lineer load

    Total Harmonic Distortion

    Crest factor

    Frequency

    Frequency Tolerance

    Overload

    125% load

    150% load

    1500% load

    Unbalanced Load

    Overall Efficiency

    PHYSICAL

    Weight without battery (kg)

    Dimensions(mm) WxDxH

    ENVIRONMENT

    Audible Noise

    Standards

    OPTIONS

    17