Uponor Under Floor Heating Operating Manual

12
UPONOR UNDERFLOOR HEATING UPONOR CONTROL SYSTEM WIRED Uponor Control System, Wired Operation Manual, UK, IRL 9416-121-00 / IOM- V_07-02

Transcript of Uponor Under Floor Heating Operating Manual

Page 1: Uponor Under Floor Heating Operating Manual

U P O N O R

U N D E R F LO O R H E AT I N G

U P O N O R CO N T R O L SYST E M W I R E D

Uponor Control System, WiredOperation Manual, UK, IRL

9416

-121

-00

/ IO

M-

V_0

7-02

Livre_R3_OM.indb 21 14/03/2007 12:11:33

Page 2: Uponor Under Floor Heating Operating Manual

Uponor Corporation Rober t Huber in t ie 3b P.O. Box 37 FI-01511 VANTAA

T +358 (0)20 129 211 F +358 (0)20 129 2841

I n k e e p i n g w i t h o u r p o l i c y o f c o n t i n u o u s i m p r o v e m e n t a n d d e v e l o p m e n t , U p o n o r r e s e r v e s t h e r i g h t t o c h a n g e s p e c i f i c a t i o n s w i t h o u t p r i o r n o t i c e .

HS South, West Area management Uponor Hispania S .A.U. Ca l le C , n° 24 Pol ígono Industr ia l n°1 E-28938 Mósto les (Madr id)

T +34 91 685 3600 F +34 91 647 3245 W www.uponor.es

Uponor Nordic PO Box 101 SE-730 61 Vi rsbo

T +46 223 380 00 F +46 223 381 01

Uponor Central Europe PO Box 1641 ( Industr iest rasse 56) D-97433 Hassfur t

T +49 (0)9521 690 0 F +49 (0)9521 690 150 W www.uponor.de

Uponor Housing Solutions Ltd. Snapethorpe House Rugby Road Lutterwor th Le icestersh i re LE17 4HN

T +44 (0)1455 550355 F +44 (0)1455 550366 W www.uponorhous ingsolut ions .co.uk E hsenqui r [email protected]

Livre_R3_OM.indb 22 14/03/2007 12:11:33

Page 3: Uponor Under Floor Heating Operating Manual

Uponor Control System - Operation Manual 3 3

Table of contents1. General recommendations ............................................................................................................................... 4

2. The Uponor Control System ............................................................................................................................ 5

2.1 Overview of the system.................................................................................................................................. 5

2.2 Operating your installation.............................................................................................................................. 6

3. Thermostat ...................................................................................................................................................... 7

3.1 Changing the temperature setpoint ................................................................................................................. 8

3.2 Setting the min and max temperatures............................................................................................................ 8

3.3 Floor sensor settings..................................................................................................................................... 9

4. System maintenance ....................................................................................................................................... 9

5. Diagnoses and resolution of faults................................................................................................................. 10

5.1 General recommendations ........................................................................................................................... 10

5.2 List of possible failures and solutions............................................................................................................. 11

6. Disposal of the product.................................................................................................................................. 12

OPERATION_MANUAL_R3-04A.mif Page 3 Mercredi, 14. mars 2007 11:09 11

Page 4: Uponor Under Floor Heating Operating Manual

4 Underfloor Heating

1. General recommendations

Safety measures• Read and follow instructions.

• Installation must be performed by a qualified person according to local regulations.

• It is prohibited to make changes or modifications not specified in this manual.

• Power must be switched off when carrying out the wiring.

• We decline any responsibility concerning damages and breakdowns that may result from the non-observance of these instructions!

Symbols used in this manual

Power supply

Technical constraintsWARNINGRisk of bodily injuries or pinching.Non observance may harm health or cause damage to product components.

STOP

CAUTIONImportant note on functionality. Non observance of this note may cause malfunctions.

InformationImportant operating advice and information.

See another document.

99See another page in the manual.

WARNING

• The Uponor Control System uses a 230VAC 50Hz power supply.

• In case of emergency, immediately disconnect the plug from the 230V mains.

• Do not use water to clean the Uponor Control System.

• Do not expose the Uponor Control System to flammable vapors or gases.

• Keep installation/data cables away from power cables > 50V to avoid interference.

• The electrical circuits of the boiler and the pump must be protected by a maximum 6A circuit-breaker.

OPERATION_MANUAL_R3-04A.mif Page 4 Mercredi, 14. mars 2007 11:09 11

Page 5: Uponor Under Floor Heating Operating Manual

Uponor Control System - Operation Manual 5 5

2. The Uponor Control SystemThe Uponor Control System is a complete management for underfloor heating systems. Comfort, user-friendliness and temperature control for each individual room of your home can be combined through the use of thermostats or floor temperature sensors.

2.1 Overview of the systemThe Uponor Control System consists of thermostats, a controller and actuators. The controller manages the operation of the actuator when the thermostats detect a demand for heating or cooling.

The Uponor Control System may be controlled with the help of three types of thermostats. Designed for maximum comfort, the thermostats communicate with the controller by non polarized two wired system. It's possible to use all kinds of Uponor Control System wired thermostats in the same system.

Thermostat T-35 wired

Thermostat T-35 is easy to use.Temperature settings are be adjusted with a dial.The dial must be removed to set min/max on the thermostat.The 21°C position is marked.

Thermostat Public T-33 wired

The thermostat is for public location. The potentiometers are hidden by a cover. The cover may be removed to allow min/max temperatures to be set. This thermostat also can be used to connect a floor sensor option.

Thermostat T-37 wired for floor sensor

Thermostat T-37 is easy to use.Temperature settings are be adjusted with a dial. The potentiometers are hidden by a cover. The dial and the cover must be removed to set up min/max on the thermostat. This thermostat also can be used to connect a floor sensor option. The 21°C position is marked.

1

2

3

OPERATION_MANUAL_R3-04A.mif Page 5 Mercredi, 14. mars 2007 11:09 11

Page 6: Uponor Under Floor Heating Operating Manual

6 Underfloor Heating

2.2 Operating your installationThe Uponor Control System controls your heating installation according to your needs. You simply have to set the temperatures you wish on the thermostats located in each room.

Principle of operation:As soon as the temperature measured at the thermostat is lower than the desired set temperature, it sends this information to the controller, which opens the actuators for this room. Once the set temperature is reached, fresh information is sent and the actuators are closed.

Normal operation without optional timer

When the system is running in normal mode:In Heating mode, the actuators are open when room temperatures are lower than the temperatures set on the thermostat.In Cooling mode, the actuators are open when room temperatures are higher than the temperature set on the thermostat.The actuator position can be seen in the small windows of the actuators.

Operation with optional timer Comfort / Economy features

The use of a timer (option) optimises the installation and conserves energy.

Controller with Thermostats and actuators

6-channel controller:

The controller controls up to 6 thermostats and 8 actuators connected to the hydraulic system of the installation.The controller drives the actuators according to the information received from each thermostat and according to the system parameters settings.The controller is typically located near the hydraulic system manifolds.The window in the actuator shows when a valve is open or closed.

12-channel controller:

The controller controls up to 12 thermostats and 14 actuators connected to the hydraulic system of the installation.The controller drives the actuators according to the information received from each thermostat and according to the system parameters settings.The controller is typically located near the hydraulic system manifolds.The window in the actuator shows when a valve is open or closed.

Several extensions can be added on to the 12 channels controller:

• A timer can be used to add energy saving features and to define the independent zones.

• If your installation is equipped with a cooling unit, the Uponor control system can be run through a heating / cooling relay.

4

If your installation is equipped with this option, see the timer Manual for more information.

OPERATION_MANUAL_R3-04A.mif Page 6 Mercredi, 14. mars 2007 11:09 11

Page 7: Uponor Under Floor Heating Operating Manual

Uponor Control System - Operation Manual 7 7

3. Thermostat

Thermostat T-35 and Thermostat T-37

Thermostat Public T-33

Open the thermostat cover: See the Installation manual.

Room temperature setpoint dial control

Terminal for controller connection (non-polarized)

Terminal for floor sensor (non-polarized)

Blue cam for setting minimum temperature

Red cam for setting maximum temperature

Floor sensor potentiometer

Heating / cooling demand LED (Opening / closing of the actuators)

Thermostat uses low voltage 6-12 volt.

1

2

3

4

5

6

7

Screw to open the thermostat

Terminal for controller connection (non-polarized)

Terminal for floor sensor (non-polarized)

Set point temperature potentiometer

Floor sensor potentiometer

Heating / cooling demand LED (Opening / closing of the actuators)

1

2

3

4

5

6

OPERATION_MANUAL_R3-04A.mif Page 7 Mercredi, 14. mars 2007 11:09 11

Page 8: Uponor Under Floor Heating Operating Manual

8 Underfloor Heating

3.1 Changing the temperature setpoint

Thermostat T-35 and Thermostat T-37

Thermostat Public T-33

3.2 Setting the min and max temperatures

Thermostat T-35 and Thermostat T-37

A red LED is lit during heating or cooling demand.

Rotate the dial clockwise to get a higher temperature setpoint

Rotate the dial counter-clockwise to get a lower temperature set point

Select the required temperature using the potentiometer

1

2

1

Remove the dial with a screwdriver

Set the minimum temperature with the blue cam

Set the maximum temperature with the red cam

The blue and red cam set the lower and upper ranges from which the set temperature is allowed to deviate.Example:

• The usual set point is 21°C.

• The setting of the blue cam is -10°C.

• The setting of the red cam is +5°C.

➜The temperature range for this room is 11°C to 26°C.

There are no min and max temperature settings for the Thermostat Public.

1

2

3

OPERATION_MANUAL_R3-04A.mif Page 8 Mercredi, 14. mars 2007 11:09 11

Page 9: Uponor Under Floor Heating Operating Manual

Uponor Control System - Operation Manual 9 9

3.3 Floor sensor settingsIf your system includes a floor sensor, a potentiometer fitted on the Thermostat Public T-33 and Thermostat T-37 allows you to adjust the minimum or maximum temperature settings for the floor.The floor sensor can be used for maximum or minimum limitation of the floor temperature, regardless of the room temperature.For example, the maximum limitation will protect a sensitive floor covering from exposure to too high temperature when there is a high heat demand. The minimum limitation can keep a tiled floor warm even when there is a no general demand for heat supply to the room.

4. System maintenanceChecks on your system components regularly to optimize performance. This system requires no maintenance.

Automatic exercise function:

The system is fitted with an automatic exercise function. Set every 6 days +/- 24 hours, this function consists of a test-run designed to prevent the pump and actuators from seizing up, when they have not been activated since the last test.

Select the required temperature using the potentiometer

See Installation manual for more information.

1

STOPUse a dry soft cloth to clean the Control System and all it's components. Do not use any detergent.

OPERATION_MANUAL_R3-04A.mif Page 9 Mercredi, 14. mars 2007 11:09 11

Page 10: Uponor Under Floor Heating Operating Manual

10 Underfloor Heating

5. Diagnoses and resolution of faultsNormal system operating conditions:

The Power LED of the controller is lit up. The actuators are activated if there is demand for heating or cooling.

5.1 General recommendations

To contact your installer:

See the Installation report in the fold-out to find the contact information for the Installer.

Please prepare the following information before contacting an installer:

• Installation report.

• Drawings of the underfloor heating system (if available).

WARNINGNote that some actions, e.g. actions involving 230V, wiring, etc., are to be performed by a qualified person.

WARNINGRisk of electric shocks. Disconnect the controller from the mains prior to any intervention.

OPERATION_MANUAL_R3-04A.mif Page 10 Mercredi, 14. mars 2007 11:09 11

Page 11: Uponor Under Floor Heating Operating Manual

Uponor Control System - Operation Manual 11 11

5.2 List of possible failures and solutions

Failure Causes Indication Solutions Note

the system does

not start

no voltage power LED off in controllercheck the circuit-breaker in the

principal electrical board

contact your

Installer if

necessary

cable breakdown230V in socket but Power LED is

off in controller

contact your

installerthe Thermostat

does not send an

order

the thermostat is out of

order

the LED of the thermostat does

not switch on or off with heating or

cooling demand

contact your

installer

room too cold (or

too warm in

Cooling mode)

thermostat is connected on

a bad channel

■ see Installation report and

check the wiring

■ the LED of the thermostat does

not switch on or off with heating

or cooling demandcontact your

installer

actuator does not openthe white indication can not be

seen in the indicator windowthe thermostat is out of

order

room too warm (or

too cold in Heating

mode)

thermostat is connected on

a bad channel

■ see Installation report and

check the wiring

■ the LED of the thermostat does

not switch on or off with heating

or cooling demand contact your

installer

actuator does not close

the corresponding loop is warm

even after a long period without

heat callthe thermostat is out of

order

the floor is cold

■ no heat demand (from

underfloor heating

system)

■ the room is heated by

another heat source

■ The supply water is too

hot. This causes a hot

floor for a short while,

followed by a cold,

uncomfortable floor

room temperature OK, but the

floor is cold

OPERATION_MANUAL_R3-04A.mif Page 11 Mercredi, 14. mars 2007 11:09 11

Page 12: Uponor Under Floor Heating Operating Manual

12 Underfloor Heating

6. Disposal of the productThe Uponor Control System is made up of various recyclable components. Uponor would be grateful if you could sort out these components (batteries, plastics, electric or electronic parts) and dispose of them at a suitable recycling centre.