Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No....

114
UPDATED REPORT OF FINDINGS Asbestos Survey AT Central Station 301 North 1 st Avenue Phoenix, Arizona EAS No. 5697 Prepared For: THE CITY OF PHOENIX 200 West Washington Street, 7th Floor Phoenix, Arizona Prepared By: MACTEC Engineering and Consulting, Inc. 3630 East Wier Avenue Phoenix, Arizona 85040 Contract No. 128588 July 19, 2010 COP Project No.: PT02120001 MACTEC Project No.: 4972-10-3001.01

Transcript of Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No....

Page 1: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

UPDATED REPORT OF FINDINGS

Asbestos Survey

AT

Central Station 301 North 1st Avenue

Phoenix, Arizona EAS No. 5697

Prepared For:

THE CITY OF PHOENIX 200 West Washington Street, 7th Floor

Phoenix, Arizona

Prepared By:

MACTEC Engineering and Consulting, Inc. 3630 East Wier Avenue Phoenix, Arizona 85040

Contract No. 128588

July 19, 2010

COP Project No.: PT02120001 MACTEC Project No.: 4972-10-3001.01

Page 2: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is
Page 3: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings

1

TABLE OF CONTENTS

PROJECT INFORMATION ........................................................................................................... 2 1.0 SCOPE ......................................................................................................................................... 2 2.0 SURVEY PROCEDURES ......................................................................................................... 2

2.1 Document Review .................................................................................................................. 3 2.2 Walk-Through and Observations ........................................................................................... 3 2.3 Bulk Sampling ........................................................................................................................ 4 2.4 Bulk Sample Analysis ............................................................................................................ 4

3.0 SUMMARY OF FINDINGS ...................................................................................................... 5 4.0 QUALIFICATIONS ................................................................................................................... 6 APPENDIX A ...................................................................................................Material Sample Sheets

APPENDIX B .............................................................................................................. Chain of Custody

Laboratory PLM Analysis Summary Laboratory Approved Accreditation Signature

PLM Analysis Detail Sheets

APPENDIX C ................................................................................ NESHAP Notification Information Personnel Certifications

APPENDIX D .............................................................................. Previous Asbestos Survey Report by

Facility GIS

Page 4: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings

2

PROJECT INFORMATION

The property that is the subject of this Report is the City of Phoenix Central Station located at 301

North 1st Avenue Street in Phoenix, Arizona. The structures on the property are constructed of block

walls with metal roofs and concrete slab floors. Our understanding is that the subject property is

scheduled for renovation.

1.0 SCOPE

The purpose of this updated asbestos verification survey was to locate, inventory and assess asbestos-

containing materials (ACM) as to type, condition, percent of asbestos content, and friability that

would be impacted during planned renovation activities. Our services included a physical inspection,

and the collection and analysis of samples of suspect materials to determine the presence of

asbestiform minerals in the subject building. Homogeneous areas of suspect materials were classified

as either Surfacing, Thermal System Insulation (TSI) or Miscellaneous, in accordance with the

Asbestos Hazard Emergency Response Act (AHERA) protocol. Additionally, identified suspect

materials were physically evaluated to determine friability. “Friable” materials are those which when

dry can be crumbled, pulverized, or reduced to powder by hand pressure.

The survey included the identification of both friable and non-friable materials used in the

construction of the subject property. These materials were classified as Regulated ACM (RACM),

Category I non-friable ACM, or Category II non-friable ACM in accordance with National Emission

Standard for Hazardous Air Pollutants (NESHAP) regulations.

2.0 SURVEY PROCEDURES

The field portion of our work included a visual survey of the subject property and the collection

and analysis of samples of suspect ACM. The property was in operation at the time of our survey.

The field portion of the work was conducted on July 16, 2010 by Mr. Matt Valenti, a certified EPA

Building Inspector. See Appendix C for a copy of the personnel certifications.

Page 5: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings

3

2.1 Document Review

The previous asbestos report prepared by Facility GIS and dated June 24, 2009, was made available to

us prior to conducting our survey and that data from the sample analysis is utilized as part of this

Updated Report of Findings.

2.2 Walk-Through and Observations

The field portion of the survey included the observation of interior and exterior finishes to identify

and locate accessible suspect ACM at the subject property. Suspect ACM are defined as those classes

of materials which have, in the past, been known to contain asbestos in some formulations. In

surveying the subject property, we have used our training in identifying suspect ACM, our familiarity

with building construction and our general engineering experience to locate potential sources of

ACM.

During our walk-through, suspect materials were noted and grouped by homogeneous area. A

“homogeneous area” (for bulk sampling purposes) is defined as an area that contains building

materials, suspected of containing asbestos, that seem by texture, color, and wear to be uniform and

applied or installed during the same general time period. Our inspector also evaluated the friability of

each material by physically touching each of the suspect materials. The general physical condition of

suspect materials was noted during the walk-through. The suspect materials observed were found to

be generally accessible.

The materials listed below were identified during the previous survey and six additional materials

found during the verification. The two digit number preceding the material description indicates the

Homogeneous Area number assigned to each material.

Central Station - Previously analyzed materials (FGIS)

• 01 – Vinyl sheet flooring, 3’ x 3’ tan • 02 – Ceramic tile and grout, 12” x 12” grey • 03 – Cove base & mastic, off white • 04 – Texture (on wallboard) white stipple • 05 – Gypsum wall board, white • 06 – Acoustical ceiling panel, 2’ x 4’ white • 07 – Cove base & mastic, off white • 08 – Texture (on wallboard), white skip trowel • 09 – Gypsum wall board, white

Page 6: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings

4

• 10 – Duct seam tape, white cloth • 11 – Concrete, pink • 12 – Ceramic tile and grout, 4” x 4” grey • 13 – Caulking compound, semi-clear • 14 – Caulking compound, white The following Materials were observed but were not to be impacted by

Renovation Activities and were not sampled in the original survey

• 15 – Block and mortar, grey (NOT SAMPLED) • 16 – Ceramic tile and grout, 2” x 2” grey (NOT SAMPLED) • 17 – Frame sealant, grey (NOT SAMPLED)

Central Station - Verification Survey Additional Materials Sampled

• 15 – Block and Mortar, gray (main building canopy columns) • 18 – Concrete pavers, 12” x 12”, rust and pink • 19 – Concrete pavers, 6” x 12” rust and pink • 20 – Concrete curbing, grey • NP-01 – Block and Mortar, grey (canopy N. of Polk St.) • SP-01 – Block and Mortar, grey (canopy S. of Polk St.)

2.3 Bulk Sampling

Following delineation of homogeneous sampling areas, bulk samples were collected from suspect

materials at random locations. For each homogeneous area sampled, the quantity of samples collected

was determined in general accordance with the AHERA sampling protocol. A total of 42 bulk

samples were collected from the suspect materials identified during the FGIS survey and 18 additional

samples were collected during the MACTEC verification survey for a total of 60 samples. Additional

samples were labeled and appropriate chain-of-custody documentation was completed.

Samples were collected from readily accessible construction materials which were representative of

the general construction of the building/property and which were considered suspect ACM.

Samples were delivered to Fiberquant Analytical Services for visual inspection and microscopic

analysis.

2.4 Bulk Sample Analysis

Samples were analyzed using Polarized Light Microscopy (PLM) coupled with dispersion staining.

Analysis was performed in general accordance with the procedures outlined in the United States

Environmental Protection Agency’s (EPA) “Method for the Determination of Asbestos in Bulk

Page 7: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings

5

Building Materials” (EPA/600/R-93/116, July 1993). The laboratory analysis of each bulk sample

relates only to the material tested, and may or may not represent the overall composition of the

homogeneous area in question. Bulk samples collected during FGIS survey were analyzed by Cates

Laboratory. Samples collected during the verification survey were analyzed by Fiberquant Analytical

services both accredited laboratories under the National Voluntary Laboratory Accreditation Program

(NVLAP).

PLM is the EPA recommended method for bulk sample analysis, and uses the unique optical and

crystallographic properties of the various constituents of the samples. The percentage quantification

of individual sample constituents was determined by visual estimation.

Non-homogeneous constituents of layered samples were analyzed as separate layers, and the

percentage of each material component, including asbestos content, was combined to represent the

total sample composition. Under regulations promulgated by the EPA, asbestos-containing materials

are defined as those materials which contain more than one percent asbestiform minerals.

Bulk samples determined to contain more than one percent asbestiform minerals are referred to as

“positive”. However, a minimum of three samples are necessary, by EPA guidelines, to confirm a

negative or non-asbestos result for a homogeneous area. Furthermore the City requires that all friable

samples determined to be ≤ 5% asbestos by PLM be Point Counted and all non-friable organically

bound materials (i.e. vinyl asbestos tile/mastic) that are determined by PLM to be ≤ 1% asbestos-

containing will have one sample of each material analyzed by Transmission Electron Microscopy

(TEM).

3.0 SUMMARY OF FINDINGS

None of the 20 suspect materials identified by MACTEC and FGIS, were determined by laboratory

analysis to contain asbestos in excess of one percent. Laboratory PLM Analysis Summary and

PLM Analysis Detail Sheets are included in Appendix B. Previous Asbestos Report conducted by

FGIS is included in Appendix D.

Page 8: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings

6

4.0 QUALIFICATIONS

MACTEC has endeavored to observe the existing conditions at the subject property using generally

accepted procedures and that degree of care and skill ordinarily exercised under similar

circumstances, by reputable consultants practicing in this or similar locations. Regardless of the

thoroughness of any survey, there is always a possibility some areas containing asbestos may be

overlooked, are inaccessible, or are different from those at specific sample locations. Therefore,

conditions at every location may not be as anticipated. In performing the survey, no attempt was

made to dismantle equipment for the purpose of obtaining samples. Wall voids, building cavities

and mechanical equipment parts may contain unreported asbestos. The findings presented in this

report are relevant to the dates of our site work and the scope of included services, and should not

be relied on to represent conditions at substantially later dates.

Page 9: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

APPENDIX A

Material Sample Sheets

Page 10: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Proj

ect N

o.:

4972

-10-

3001

.01

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

15

M

ater

ial C

ode:

B

&M

M

ater

ial D

escr

iptio

n:

Blo

ck a

nd M

orta

r F

riabl

e

Non

-Fria

ble

Size

: N

/A

Prim

ary

Col

or:

Gre

y S

econ

dary

C

olor

: G

rey

Text

ure:

N

/A

Mat

eria

l Qua

ntity

: 4,

000

SF

LF

EA

CH

Est

imat

ed B

y:

Dra

win

g F

ield

Mea

sure

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Mai

n B

uild

ing,

Eas

t Can

opy,

Wes

t Can

opy

and

Sou

th C

anop

y

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A Ea

st C

anop

y SE

0

0 2

F - W

- C

- O

N

o N

one

dete

cted

B So

uth

Can

opy

NW

0

0 2

F - W

- C

- O

N

o N

one

dete

cted

C

Wes

t Can

opy

SW

0 30

2

F - W

- C

- O

N

o N

one

dete

cted

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

7/

16/1

0

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E34

03

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/4/

10

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 11: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Proj

ect N

o.:

4972

-10-

3001

.01

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

18

M

ater

ial C

ode:

C

P

Mat

eria

l Des

crip

tion:

C

oncr

ete

Pav

ers

Fria

ble

N

on-F

riabl

e

Siz

e:

12” x

12”

P

rimar

y C

olor

: P

ink/

Rus

t S

econ

dary

C

olor

: N

/A

Text

ure:

N

/A

Mat

eria

l Qua

ntity

: 8,

000

SF

LF

EA

CH

Est

imat

ed B

y:

Dra

win

g F

ield

Mea

sure

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Var

ious

Are

as th

roug

h-ou

t site

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A

SW

of S

W c

olum

n, E

ast C

anop

y S

E

0 0

0 F

- W -

C -

O

No

Non

e de

tect

ed

B

SW

of N

W c

olum

n , S

Can

opy

NW

0

0 0

F - W

- C

- O

N

o N

one

dete

cted

C

S o

f SW

col

umn,

Wes

t Can

opy

SW

0

0 0

F - W

- C

- O

N

o N

one

dete

cted

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

7/

16/1

0

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E34

03

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/4/

10

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 12: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Proj

ect N

o.:

4972

-10-

3001

.01

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

19

M

ater

ial C

ode:

C

P

Mat

eria

l Des

crip

tion:

C

oncr

ete

Pav

ers

Fria

ble

N

on-F

riabl

e

Siz

e:

6” x

12”

P

rimar

y C

olor

: P

ink/

Rus

t S

econ

dary

C

olor

: N

/A

Text

ure:

N

/A

Mat

eria

l Qua

ntity

: 1,

000

SF

LF

EA

CH

Est

imat

ed B

y:

Dra

win

g F

ield

Mea

sure

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Var

ious

Are

as th

roug

h-ou

t site

alo

ng d

rives

nex

t to

curb

ing

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A

Mai

n D

rive

(N/S

) N

W

0 0

0 F

- W -

C -

O

No

Non

e de

tect

ed

B So

uth

Can

opy

NW

0

0 0

F - W

- C

- O

N

o N

one

dete

cted

C

Wes

t Can

opy

SW

0 0

0 F

- W -

C -

O

No

Non

e de

tect

ed

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

7/

16/1

0

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E34

03

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/4/

10

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 13: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Proj

ect N

o.:

4972

-10-

3001

.01

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

20

M

ater

ial C

ode:

C

ON

M

ater

ial D

escr

iptio

n:

Con

cret

e (c

urbi

ng)

Fria

ble

N

on-F

riabl

e

Size

: N

/A

Prim

ary

Col

or:

Gre

y S

econ

dary

C

olor

: N

/A

Text

ure:

N

/A

Mat

eria

l Qua

ntity

: 1,

500

SF

LF

EA

CH

Est

imat

ed B

y:

Dra

win

g F

ield

Mea

sure

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Alo

ng a

ll dr

ive

area

s

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A

Mai

n D

rive

(N/S

) SW

of M

ain

Bld

g.

N/A

0

0 0

F - W

- C

- O

N

o N

one

dete

cted

B

Sou

th o

f Pol

k S

t. N

Can

opy

N/A

0

0 0

F - W

- C

- O

N

o N

one

dete

cted

C

Eas

t of S

. Pol

k S

t. C

anop

y N

/A

0 0

0 F

- W -

C -

O

No

Non

e de

tect

ed

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

7/

16/1

0

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E34

03

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/4/

10

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 14: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Proj

ect N

o.:

4972

-10-

3001

.01

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

N

P01

M

ater

ial C

ode:

B

&M

M

ater

ial D

escr

iptio

n:

Blo

ck a

nd M

orta

r F

riabl

e

Non

-Fria

ble

Size

: N

/A

Prim

ary

Col

or:

Gre

y S

econ

dary

C

olor

: G

rey

Text

ure:

N

/A

Mat

eria

l Qua

ntity

: 40

0 S

F L

F E

AC

HE

stim

ated

By:

D

raw

ing

Fie

ld M

easu

re

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Can

opy

Nor

th o

f Pol

k S

treet

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A

N. P

olk

St.

Can

opy

NW

0

0 2

F - W

- C

- O

N

o N

one

dete

cted

B

N. P

olk

St.

Can

opy

NW

10

0

2 F

- W -

C -

O

No

Non

e de

tect

ed

C

N. P

olk

St.

Can

opy

NE

0

0 2

F - W

- C

- O

N

o N

one

dete

cted

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

7/

16/1

0

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E34

03

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/4/

10

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 15: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Proj

ect N

o.:

4972

-10-

3001

.01

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

S

P01

M

ater

ial C

ode:

B

&M

M

ater

ial D

escr

iptio

n:

Blo

ck a

nd M

orta

r F

riabl

e

Non

-Fria

ble

Size

: N

/A

Prim

ary

Col

or:

Gre

y S

econ

dary

C

olor

: G

rey

Text

ure:

N

/A

Mat

eria

l Qua

ntity

: 30

0 S

F L

F E

AC

HE

stim

ated

By:

D

raw

ing

Fie

ld M

easu

re

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Can

opy

Sou

th o

f Pol

k S

treet

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A

S. P

olk

St.

Can

opy

SE

0

0 2

F - W

- C

- O

N

o N

one

dete

cted

B

S. P

olk

St.

Can

opy

SW

0

0 2

F - W

- C

- O

N

o N

one

dete

cted

C

S. P

olk

St.

Can

opy

NW

0

0 2

F - W

- C

- O

N

o N

one

dete

cted

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

7/

16/1

0

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E34

03

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/4/

10

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 16: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

APPENDIX B

Chain of Custody

Laboratory PLM Analysis Summary Laboratory Approved Accreditation Signature

PLM Analysis Detail Sheets

Page 17: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is
Page 18: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is
Page 19: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is
Page 20: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

PLM Analysis Details Job Number: 201005998 Central Station-Updated Survey

2010-05998- 115A 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Miscellaneous

No

Non-fibrous SolidOKAn?

2# Layers NoPos Layer?

Apparent Smp Type

none Fiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of cementitious components using acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

6# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 75 n.d. - - - - -block gray 1

2 25 n.d. - - - - -mortar gray 1

100Total % n.d. - - - - -Average %

2010-05998- 215B 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Miscellaneous

No

Non-fibrous SolidOKAn?

2# Layers NoPos Layer?

Apparent Smp Type

none Fiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of cementitious components using acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

6# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 60 n.d. - - - - -block gray 1

2 40 n.d. - - - - -mortar gray 1

100Total % n.d. - - - - -Average %

2010-05998- 315C 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Miscellaneous

No

Non-fibrous SolidOKAn?

2# Layers NoPos Layer?

Apparent Smp Type

none Fiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of cementitious components using acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

6# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 50 n.d. - - - - -block gray 1

2 50 n.d. - - - - -mortar gray 1

100Total % n.d. - - - - -Average %

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Fiberquant, Inc. Page 3 of 9

Page 21: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

PLM Analysis Details Job Number: 201005998 Central Station-Updated Survey

2010-05998- 418A 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Cementitious

Yes

Non-fibrous SolidOKAn?

1# Layers NoPos Layer?

Apparent Smp Type

noneFiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of matrix using dilute HCl acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

3# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 100 n.d. - - - - -concrete gray 1

100Total % n.d. - - - - -Average %

2010-05998- 518B 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Cementitious

Yes

Non-fibrous SolidOKAn?

1# Layers NoPos Layer?

Apparent Smp Type

noneFiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of matrix using dilute HCl acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

3# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 100 n.d. - - - - -concrete brown 1

100Total % n.d. - - - - -Average %

2010-05998- 618C 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Cementitious

Yes

Non-fibrous SolidOKAn?

1# Layers NoPos Layer?

Apparent Smp Type

noneFiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of matrix using dilute HCl acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

3# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 100 n.d. - - - - -concrete brown 1

100Total % n.d. - - - - -Average %

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Fiberquant, Inc. Page 4 of 9

Page 22: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

PLM Analysis Details Job Number: 201005998 Central Station-Updated Survey

2010-05998- 719A 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Cementitious

Yes

Non-fibrous SolidOKAn?

1# Layers NoPos Layer?

Apparent Smp Type

noneFiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of matrix using dilute HCl acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

3# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 100 n.d. - - - - -concrete brown 1

100Total % n.d. - - - - -Average %

2010-05998- 819B 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Cementitious

Yes

Non-fibrous SolidOKAn?

1# Layers NoPos Layer?

Apparent Smp Type

noneFiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of matrix using dilute HCl acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

3# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 100 n.d. - - - - -concrete brown 1

100Total % n.d. - - - - -Average %

2010-05998- 919C 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Cementitious

Yes

Non-fibrous SolidOKAn?

1# Layers NoPos Layer?

Apparent Smp Type

noneFiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of matrix using dilute HCl acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

3# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 100 n.d. - - - - -concrete brown 1

100Total % n.d. - - - - -Average %

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Fiberquant, Inc. Page 5 of 9

Page 23: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

PLM Analysis Details Job Number: 201005998 Central Station-Updated Survey

2010-05998- 1020A 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Cementitious

Yes

Non-fibrous SolidOKAn?

1# Layers NoPos Layer?

Apparent Smp Type

noneFiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of matrix using dilute HCl acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

3# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 100 n.d. - - - - -concrete gray 1

100Total % n.d. - - - - -Average %

2010-05998- 1120B 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Cementitious

Yes

Non-fibrous SolidOKAn?

1# Layers NoPos Layer?

Apparent Smp Type

noneFiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of matrix using dilute HCl acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

3# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 100 n.d. - - - - -concrete gray 1

100Total % n.d. - - - - -Average %

2010-05998- 1220C 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Cementitious

Yes

Non-fibrous SolidOKAn?

1# Layers NoPos Layer?

Apparent Smp Type

noneFiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of matrix using dilute HCl acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

3# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 100 n.d. - - - - -concrete gray 1

100Total % n.d. - - - - -Average %

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Fiberquant, Inc. Page 6 of 9

Page 24: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

PLM Analysis Details Job Number: 201005998 Central Station-Updated Survey

2010-05998- 13NP01A 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Miscellaneous

No

Non-fibrous SolidOKAn?

2# Layers NoPos Layer?

Apparent Smp Type

none Fiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of cementitious components using acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

6# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 45 n.d. - - - - -block gray 1

2 55 n.d. - - - - -mortar gray 1

100Total % n.d. - - - - -Average %

2010-05998- 14NP01B 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Miscellaneous

No

Non-fibrous SolidOKAn?

2# Layers NoPos Layer?

Apparent Smp Type

none Fiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of cementitious components using acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

6# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 50 n.d. - - - - -block gray 1

2 50 n.d. - - - - -mortar gray 1

100Total % n.d. - - - - -Average %

2010-05998- 15NP01C 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Miscellaneous

No

Non-fibrous SolidOKAn?

2# Layers NoPos Layer?

Apparent Smp Type

none Fiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of cementitious components using acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

6# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 55 n.d. - - - - -block gray 1

2 45 n.d. - - - - -mortar gray 1

100Total % n.d. - - - - -Average %

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Fiberquant, Inc. Page 7 of 9

Page 25: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

PLM Analysis Details Job Number: 201005998 Central Station-Updated Survey

2010-05998- 16SP01A 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Miscellaneous

No

Non-fibrous SolidOKAn?

2# Layers NoPos Layer?

Apparent Smp Type

none Fiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of cementitious components using acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

6# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 55 n.d. - - - - -block gray 1

2 45 n.d. - - - - -mortar gray 1

100Total % n.d. - - - - -Average %

2010-05998- 17SP01B 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Miscellaneous

No

Non-fibrous SolidOKAn?

2# Layers NoPos Layer?

Apparent Smp Type

none Fiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of cementitious components using acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

6# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 65 n.d. - - - - -block gray 1

2 35 n.d. - - - - -mortar gray 1

100Total % n.d. - - - - -Average %

2010-05998- 18SP01C 7/16/2010Lab Number Sample Sampled:

RAMAnalyzed By 7/16/2010

Homogeneous

Miscellaneous

No

Non-fibrous SolidOKAn?

2# Layers NoPos Layer?

Apparent Smp Type

none Fiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of cementitious components using acid.

Fibers

1

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations

2

3

4

5

6

none

Non-Fibrous Components (in approx. decreasing order): powder, rock,

6# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 75 n.d. - - - - -block gray 1

2 25 n.d. - - - - -mortar gray 1

100Total % n.d. - - - - -Average %

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Fiberquant, Inc. Page 8 of 9

Page 26: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

PLM Analysis Details Job Number: 201005998 Central Station-Updated Survey

Fr=Friability: 1=very non-friable; 2= non-friable; 3=friable; 4=highly friable

Colors: B=black;BL=blue;BR=brown;CL=clear;G=Green;GY=gray;OR=orange;OW=off-white;PN=pink;PU=purple;R=red;TN=tan;W=white;Y=yellow;V=various

Fiber Morphology: A=fine fibers/bundles, white, sinewy, flexible; B=fine fibers/bundles, w-br, straight, broomed ends; C=fine fibers/bundles, blue, straight, broomed ends;

D=fine to coarse fibers, CL-B, brittle; E=coarse fibers,CL or dyed, striated; F=coarse fibers or splinters, W-BR, ribbon-like; G=lath-like or shards, low aspect ratio, may taper

Iso=isotropism - may be yes or no; Pleo=pleochroism - may be yes or no; Bi=birefringence - may be None, Low, Medium or High

Elg=sign of elongation - may be +, - or B (both); Ext=extinction - may be Parallel, Oblique, None or Undulating; Oil=medium used to for dispersion staining

Col Par=dispersion staining colors parallel to the fiber (fiber/halo): b/w=black/white; dg/py=dark gray/pale yellow; vg/y=violet gray/yellow; db/ly=dark blue/lemon yellow;

vb/g= vivid blue/gold; sb/o=sky blue/orange; pb/r=pale blue/red; gb/dr=gray blue/dark red; w/b=white/black. Col Perp=same only perpendicular to fiber.

RI Par=refractive index parallel to fiber; RI Perp=refractive index perpendicular to fiber

16-Jul-10Analyst: ROBERT A. McCORMICK

Larry S. Pierce, Approved Accreditation Signatory

Printed:

16-Jul-10Original Print Date:

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Fiberquant, Inc. Page 9 of 9

Page 27: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

APPENDIX C

NESHAP Notification Information

Personnel Certifications

Page 28: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

NESHAP NOTIFICATION INFORMATION

Property Owner .............................................................................................................. City of Phoenix Address ................................................................................................................... 301 North 1st Avenue

Phoenix, Arizona Original Survey Date (FGIS) ......................................................................................................... 6/2/09 Verification Survey Date (MACTEC) ........................................................................................ 7/16/10 Number of Bulk Samples Collected original Survey .............................................................. 42 PLM Number of Bulk Samples Collected Verification Survey ....................................................... 18 PLM Date of Original Analysis ............................................................................................................. 6/10/09 Date of Verification sample Analysis .......................................................................................... 7/16/10 Lab Performing Original Analysis ........................................................................... Cates Laboratory Lab Performing Additional Analysis ................................................ Fiberquant Analytical Services Original Survey Inspectors ..................................................................................................................... 1 Verification Survey Inspectors ............................................................................................................... 1 MACTEC Project Number ......................................................................................... 4972-10-3001.01

Inspector Cert. No. Expiration Training Center

Matt Valenti E1007 9/5/09 The Asbestos Institute

Matt Valenti E3403 9/4/10 The Asbestos Institute

No Asbestos Detected in Samples collected

Page 29: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is
Page 30: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

APPENDIX D

Previous Asbestos Survey Report By

Facility GIS

Page 31: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

REPORT OF FINDINGS Limited Asbestos Survey

AT

Central Station

300 North Central Avenue Phoenix, Arizona

APN 111-42-114

Prepared For:

THE CITY OF PHOENIX 200 West Washington Street, 7th Floor

Phoenix, Arizona

Prepared By:

:

Facility GIS, Inc. 7810 South Hardy Dr. #104

Tempe, Arizona 85284

June 24, 2009

COP Project No.: PT02120001-1 FGIS Project No.: COP09028

Page 32: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

7810 South Hardy Dr. #104, Tempe, AZ 85284 (602) 749-8300 office (602) 749-8301 fax

[email protected]

June 24, 2009 Mr. James Marshall Environmental Quality Specialist City of Phoenix Engineering and Architectural Services Department 200 West Washington Street, 7th Floor Phoenix, Arizona 85003-1611 Subject: Report of Findings Limited Asbestos Survey Central Station 300 Central Avenue, Suite 700 Phoenix, Arizona COP Project No.: PT02120001-1 FGIS Project No.: COP09028 Dear Mr. Marshall: Facility GIS, Inc., (FGIS) is pleased to submit this report of findings for the limited asbestos survey recently conducted at the above subject property. FGIS performed its services for the City of Phoenix (City) in accordance with local, state, and federal regulatory requirements, and the terms and conditions of our Annual Services Contract No. 121392 currently on file with the City. This report identifies the purpose, scope, procedures, summary of findings and qualifications of the survey. Within these sections, the various types, locations, accessibility, condition, NESHAP classification and estimated quantity of asbestos-containing materials are identified. Additionally, plans depicting sample locations, copies of laboratory analysis sheets and EPA Building Inspector certifications are included in the report's appendices. We appreciate the opportunity to provide consulting services to the City of Phoenix. If you should have any questions pertaining to this report, please contact us at (602) 749-8300. Sincerely, Facility GIS, Inc. Matthew Valenti Project Manager

Page 33: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

300 N. Central Ave. June 24, 2009 FGIS Project No. COP09028 Report of Findings

1

TABLE OF CONTENTS

PROJECT INFORMATION ................................................................................................. 2 1.0 SCOPE.......................................................................................................................... 2 2.0 SURVEY PROCEDURES ............................................................................................. 2

2.1 Document Review ................................................................................................... 3 2.2 Walk-Through and Observations............................................................................. 3 2.3 Bulk Sampling ......................................................................................................... 4 2.4 Bulk Sample Analysis.............................................................................................. 4

3.0 SUMMARY OF FINDINGS............................................................................................ 5 4.0 QUALIFICATIONS........................................................................................................ 5 APPENDIX A.....................................................................................Material Sample Sheets

Vicinity Plan Floor Plan

Asbestos Sample Location Plan

APPENDIX B................................................................................................Chain of Custody Laboratory PLM Analysis Summary

Laboratory Approved Accreditation Signature PLM Analysis Detail Sheets

APPENDIX C.....................................................................NESHAP Notification Information

Personnel Certifications

Page 34: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

300 N. Central Ave. June 24, 2009 FGIS Project No. COP09028 Report of Findings

2

PROJECT INFORMATION

The property that is the subject of this report is Central Station located at 300 North Central

Avenue in Phoenix, Arizona. The structure on the property is constructed of block walls with

metal roof trusses, metal roof and a concrete slab floors. Our understanding is that the

subject property is scheduled for renovation.

1.0 SCOPE

The purpose of the limited asbestos survey was to locate, inventory and assess asbestos-

containing materials (ACM) as to type, condition, percent of asbestos content, and friability

that would be impacted during planned renovation activities. Our services included a

physical inspection, and the collection and analysis of samples of suspect materials to

determine the presence of asbestiform minerals in the subject building. Homogeneous areas

of suspect materials were classified as either Surfacing, Thermal System Insulation (TSI) or

Miscellaneous, in accordance with the Asbestos Hazard Emergency Response Act

(AHERA) protocol. Additionally, identified suspect materials were physically evaluated to

determine friability. “Friable” materials are those which when dry can be crumbled,

pulverized, or reduced to powder by hand pressure.

The survey included the identification of both friable and non-friable materials used in the

construction of the subject property. These materials were classified as Regulated ACM

(RACM), Category I non-friable ACM, or Category II non-friable ACM in accordance with

National Emission Standard for Hazardous Air Pollutants (NESHAP) regulations.

2.0 SURVEY PROCEDURES

The field portion of our work included a visual survey of the subject property and the

collection and analysis of samples of suspect ACM. The subject area was occupied at the

time of our survey. The field portion of the work was conducted on June 2, 2009 by Mr.

Matt Valenti, a certified EPA Building Inspector. See Appendix C for a copy of the

personnel certifications.

Page 35: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

300 N. Central Ave. June 24, 2009 FGIS Project No. COP09028 Report of Findings

3

2.1 Document Review

No asbestos reports were made available to us prior to conducting the survey.

2.2 Walk-Through and Observations

The field portion of the survey included the observation of interior finishes to identify and

locate accessible suspect ACM at the subject property. Suspect ACM are defined as those

classes of materials which have, in the past, been known to contain asbestos in some

formulations. In surveying the subject property, we have used our training in identifying

suspect ACM, our familiarity with building construction and our general engineering

experience to locate potential sources of ACM.

During our walk-through, suspect materials were noted and grouped by homogeneous area.

A “homogeneous area” (for bulk sampling purposes) is defined as an area that contains

building materials, suspected of containing asbestos, that seem by texture, color, and wear

to be uniform and applied or installed during the same general time period. Our inspector

also evaluated the friability of each material by physically touching each of the suspect

materials. The general physical condition of suspect materials was noted during the walk-

through. The suspect materials observed were found to be generally accessible.

The materials listed below were identified during the survey. The two digit number

preceding the material description indicates the Homogeneous Area number assigned to

each material. Materials found to be ACM are denoted in bold.

Central Station – 301 N 1st Avenue

• 01 – Vinyl sheet flooring, 3’ x 3’ tan • 02 – Ceramic tile and grout, 12” x 12” grey • 03 – Cove base & mastic, off white • 04 – Texture (on wallboard) white stipple • 05 – Gypsum wall board, white • 06 – Acoustical ceiling panel, 2’ x 4’ white • 07 – Cove base & mastic, off white • 08 – Texture (on wallboard), white skip trowel • 09 – Gypsum wall board, white • 10 – Duct seam tape, white cloth • 11 – Concrete, pink • 12 – Ceramic tile and grout, 4” x 4” grey • 13 – Caulking compound, semi-clear • 14 – Caulking compound, white

Page 36: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

300 N. Central Ave. June 24, 2009 FGIS Project No. COP09028 Report of Findings

4

The following Materials were observed but will not be impacted by renovation Activities and were not sampled

• 15 – Block and mortar, grey (NOT SAMPLED) • 16 – Ceramic tile and grout, 2” x 2” grey (NOT SAMPLED) • 17 – Frame sealant, grey (NOT SAMPLED)

2.3 Bulk Sampling

Following delineation of homogeneous sampling areas, bulk samples were collected from

suspect materials at random locations. For each homogeneous area sampled, the quantity

of samples collected was determined in general accordance with the AHERA sampling

protocol. A total of 42 bulk samples were collected from the suspect materials identified

during the survey. Samples were labeled and appropriate chain-of-custody documentation

was completed.

Samples were collected from readily accessible construction materials which were

representative of the general construction of the building, and which were considered

suspect ACM. Destructive activity, such as breaking through walls or ceilings was performed

in order to collect samples. Samples were delivered to Cates Laboratories for visual

inspection and microscopic analysis.

2.4 Bulk Sample Analysis

Samples were analyzed using Polarized Light Microscopy (PLM) coupled with dispersion

staining. Analysis was performed in general accordance with the procedures outlined in the

United States Environmental Protection Agency’s (EPA) “Method for the Determination of

Asbestos in Bulk Building Materials” (EPA/600/R-93/116, July 1993). The laboratory

analysis of each bulk sample relates only to the material tested, and may or may not

represent the overall composition of the homogeneous area in question. Bulk samples were

analyzed by Cates Laboratories an accredited laboratory under the National Voluntary

Laboratory Accreditation Program (NVLAP).

PLM is the EPA recommended method for bulk sample analysis, and uses the unique

optical and crystallographic properties of the various constituents of the samples. The

percentage quantification of individual sample constituents was determined by visual

estimation.

Page 37: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

300 N. Central Ave. June 24, 2009 FGIS Project No. COP09028 Report of Findings

5

Non-homogeneous constituents of layered samples were analyzed as separate layers, and

the percentage of each material component, including asbestos content, was combined to

represent the total sample composition. Under regulations promulgated by the EPA,

asbestos-containing materials are defined as those materials which contain more than one

percent asbestiform minerals.

Bulk samples determined to contain more than one percent asbestiform minerals are

referred to as “positive”. However, a minimum of three samples are necessary, by EPA

guidelines, to confirm a negative or non-asbestos result for a homogeneous area. Further

more the City requires that all friable samples determined to be ≤ 5% asbestos by PLM be

Point Counted and all non-friable organically bound materials (i.e. vinyl asbestos tile/mastic)

that are determined by PLM to be ≤ 1% asbestos-containing will have one sample of each

material analyzed by Transmission Electron Microscopy (TEM).

3.0 SUMMARY OF FINDINGS

Of the 14 suspect materials identified and sampled by FGIS, none of the materials were

determined by laboratory analysis to contain asbestos in excess of one percent.

Laboratory PLM Analysis Summary and PLM Analysis Detail Sheets are included in

Appendix B.

4.0 QUALIFICATIONS

FGIS has endeavored to observe the existing conditions at the subject property using

generally accepted procedures and that degree of care and skill ordinarily exercised under

similar circumstances, by reputable consultants practicing in this or similar locations.

Regardless of the thoroughness of any survey, there is always a possibility some areas

containing asbestos may be overlooked, are inaccessible, or are different from those at

specific sample locations. Therefore, conditions at every location may not be as

anticipated. In performing the survey, no attempt was made to dismantle equipment for

the purpose of obtaining samples. Wall voids, building cavities and mechanical equipment

parts may contain unreported asbestos. The findings presented in this report are relevant

to the dates of our site work and the scope of included services, and should not be relied

on to represent conditions at substantially later dates.

Page 38: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

APPENDIX A

Material Sample Sheets

Vicinity Plan Floor Plan

Asbestos Sample Location Plan

Page 39: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

01

M

ater

ial C

ode:

V

SF

Mat

eria

l Des

crip

tion:

V

inyl

She

et F

loor

ing

Fria

ble

N

on-F

riabl

e

Siz

e:

3’ x

3’

Prim

ary

Col

or:

Tan

Sec

onda

ry

Col

or:

N/A

Te

xtur

e:

N/A

Mat

eria

l Qua

ntity

: 96

9 S

F L

F E

AC

HE

stim

ated

By:

D

raw

ing

Fie

ld M

easu

re

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Roo

m’s

1, 2

, 3 a

nd 4

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A R

oom

4

NW

1

0 0

F - W

- C

- O

N

o N

one

dete

cted

– s

heet

floo

ring

Non

e de

tect

ed –

yel

low

mas

tic

B R

oom

1

SE

2 0

0 F

- W -

C -

O

No

Non

e de

tect

ed –

she

et fl

oorin

g N

one

dete

cted

– y

ello

w m

astic

C

Roo

m 3

N

E 3

0 0

F - W

- C

- O

N

o N

one

dete

cted

– s

heet

floo

ring

Non

e de

tect

ed –

yel

low

mas

tic

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

2/09

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 40: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

02

M

ater

ial C

ode:

C

TG

Mat

eria

l Des

crip

tion:

C

eram

ic T

ile a

nd G

rout

F

riabl

e

Non

-Fria

ble

Siz

e:

12” x

12”

P

rimar

y C

olor

: G

rey

Sec

onda

ry

Col

or:

N/A

Te

xtur

e:

N/A

Mat

eria

l Qua

ntity

: 1,

366

SF

LF

EA

CH

Est

imat

ed B

y:

Dra

win

g F

ield

Mea

sure

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Roo

m’s

5, 6

, 10,

11,

18,

19

and

20

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A R

oom

5

NE

3 0

0 F

- W -

C -

O

No

Non

e de

tect

ed –

Cer

amic

tile

N

one

dete

cted

- G

rout

B R

oom

5

NW

1

0 0

F - W

- C

- O

N

o N

one

dete

cted

– C

eram

ic ti

le

Non

e de

tect

ed -

Gro

ut

C

Roo

m 1

1 N

W

0 0

0 F

- W -

C -

O

No

Non

e de

tect

ed –

Cer

amic

tile

N

one

dete

cted

- G

rout

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

2/09

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 41: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

03

M

ater

ial C

ode:

C

BM

M

ater

ial D

escr

iptio

n:

Cov

e B

ase

and

Mas

tic

Fria

ble

N

on-F

riabl

e

Siz

e:

4”

Prim

ary

Col

or:

Off

whi

te

Sec

onda

ry

Col

or:

N/A

Te

xtur

e:

N/A

Mat

eria

l Qua

ntity

: 15

1 S

F L

F E

AC

HE

stim

ated

By:

D

raw

ing

Fie

ld M

easu

re

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Roo

m’s

1, 2

, 3 a

nd 4

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A R

oom

4

NW

0

0 0

F - W

- C

- O

N

o N

one

dete

cted

B R

oom

1

SE

2 0

0 F

- W -

C -

O

No

Non

e de

tect

ed

C

Roo

m 3

N

E 3

0 0

F - W

- C

- O

N

o N

one

dete

cted

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

2/09

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 42: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

04

M

ater

ial C

ode:

TE

X

Mat

eria

l Des

crip

tion:

Te

xtur

e (o

n w

allb

oard

) F

riabl

e

Non

-Fria

ble

Size

: N

/A

Prim

ary

Col

or:

Whi

te

Sec

onda

ry

Col

or:

N/A

Te

xtur

e:

Stip

ple

Mat

eria

l Qua

ntity

: 5,

900

SF

LF

EA

CH

Est

imat

ed B

y:

Dra

win

g F

ield

Mea

sure

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Wal

ls in

room

’s 1

, 2, 3

, 4, 5

, 6, 7

, 8, 9

, 10,

11,

12,

13

and

20

Cei

lings

in ro

om’s

3, 5

, 7, 8

, 9, 1

2, 1

3,18

, 19

and

20

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A R

oom

4

NW

7

0 3

F - W

- C

- O

N

o N

one

dete

cted

B R

oom

5

NW

0

3 0

F - W

- C

- O

N

o N

one

dete

cted

C

Roo

m 1

1 SW

1

0 1

F - W

- C

- O

N

o N

one

dete

cted

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

2/09

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 43: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

05

M

ater

ial C

ode:

G

WB

M

ater

ial D

escr

iptio

n:

Gyp

sum

Wal

l Boa

rd

Fria

ble

N

on-F

riabl

e

Size

: N

/A

Prim

ary

Col

or:

Whi

te

Sec

onda

ry

Col

or:

N/A

Te

xtur

e:

N/A

Mat

eria

l Qua

ntity

: 5,

900

SF

LF

EA

CH

Est

imat

ed B

y:

Dra

win

g F

ield

Mea

sure

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Wal

ls in

room

’s 1

, 2, 3

, 4, 5

, 6, 7

, 8, 9

, 10,

11,

12,

13

and

20

Cei

lings

in ro

om’s

3, 5

, 7, 8

, 9, 1

2, 1

3,18

, 19

and

20

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A R

oom

4

NW

7

0 3

F - W

- C

- O

N

o N

one

dete

cted

– p

aper

N

one

dete

cted

– w

allb

oard

mat

eria

l

B R

oom

5

NW

0

3 0

F - W

- C

- O

N

o N

one

dete

cted

– p

aper

N

one

dete

cted

– w

allb

oard

mat

eria

l

C

Roo

m 1

1 SW

1

0 1

F - W

- C

- O

N

o N

one

dete

cted

– p

aper

N

one

dete

cted

– w

allb

oard

mat

eria

l

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

2/09

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 44: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

06

M

ater

ial C

ode:

A

CP

M

ater

ial D

escr

iptio

n:

Aco

ustic

al C

eilin

g P

anel

F

riabl

e

Non

-Fria

ble

Siz

e:

2’ x

4’

Prim

ary

Col

or:

Whi

te

Sec

onda

ry

Col

or:

N/A

Te

xtur

e:

N/A

Mat

eria

l Qua

ntity

: 1,

895

SF

LF

EA

CH

Est

imat

ed B

y:

Dra

win

g F

ield

Mea

sure

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Roo

m’s

1, 2

, 3, 4

, 5, 6

, 10

and

11

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A R

oom

4

NW

4

1 9

F - W

- C

- O

N

o N

one

dete

cted

B R

oom

5

SW

8 0

9 F

- W -

C -

O

No

Non

e de

tect

ed

C

Roo

m 1

0 SW

3

2 9

F - W

- C

- O

N

o N

one

dete

cted

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

2/09

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 45: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

07

M

ater

ial C

ode:

C

BM

M

ater

ial D

escr

iptio

n:

Cov

e B

ase

and

Mas

tic

Fria

ble

N

on-F

riabl

e

Siz

e:

4”

Prim

ary

Col

or:

Bro

wn

Sec

onda

ry

Col

or:

N/A

Te

xtur

e:

N/A

Mat

eria

l Qua

ntity

: 30

6 S

F L

F E

AC

HE

stim

ated

By:

D

raw

ing

Fie

ld M

easu

re

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Roo

m’s

5, 6

, 9, 1

0, 1

1, 1

2 an

d 13

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A R

oom

5

NE

3 0

0 F

- W -

C -

O

No

Non

e de

tect

ed

B R

oom

6

SW

0 5

0 F

- W -

C -

O

No

Non

e de

tect

ed

C

Roo

m 1

0 SW

0

0 0

F - W

- C

- O

N

o N

one

dete

cted

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

2/09

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 46: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

08

M

ater

ial C

ode:

TE

X

Mat

eria

l Des

crip

tion:

Te

xtur

e (o

n w

allb

oard

) F

riabl

e

Non

-Fria

ble

Size

: N

/A

Prim

ary

Col

or:

Whi

te

Sec

onda

ry

Col

or:

N/A

Te

xtur

e:

Ski

p tro

wel

Mat

eria

l Qua

ntity

: 75

0 S

F L

F E

AC

HE

stim

ated

By:

D

raw

ing

Fie

ld M

easu

re

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Roo

m 1

4 N

orth

wal

l, ro

om 1

5 E

ast a

nd s

outh

wal

ls, r

oom

16

Eas

t and

Wes

t wal

ls a

nd ro

om 1

7 W

est w

all

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A R

oom

14

NE

2 0

2 F

- W -

C -

O

No

Non

e de

tect

ed

B R

oom

15

SE

4 0

2 F

- W -

C -

O

No

Non

e de

tect

ed

C

Roo

m 1

5 N

E 0

1 4

F - W

- C

- O

N

o N

one

dete

cted

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

2/09

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 47: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

09

M

ater

ial C

ode:

G

WB

M

ater

ial D

escr

iptio

n:

Gyp

sum

Wal

l Boa

rd

Fria

ble

N

on-F

riabl

e

Size

: N

/A

Prim

ary

Col

or:

Whi

te

Sec

onda

ry

Col

or:

N/A

Te

xtur

e:

N/A

Mat

eria

l Qua

ntity

: 75

0 S

F L

F E

AC

HE

stim

ated

By:

D

raw

ing

Fie

ld M

easu

re

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Roo

m 1

4 N

orth

wal

l, ro

om 1

5 E

ast a

nd s

outh

wal

ls, r

oom

16

Eas

t and

Wes

t wal

ls a

nd ro

om 1

7 W

est w

all

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A R

oom

14

NE

2 0

2 F

- W -

C -

O

No

Non

e de

tect

ed –

wal

lboa

rd m

ater

ial

B R

oom

15

SE

4 0

2 F

- W -

C -

O

No

Non

e de

tect

ed –

pap

er

Non

e de

tect

ed –

wal

lboa

rd m

ater

ial

C

Roo

m 1

5 N

E 0

1 4

F - W

- C

- O

N

o N

one

dete

cted

– p

aper

N

one

dete

cted

– w

allb

oard

mat

eria

l

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

2/09

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 48: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

10

M

ater

ial C

ode:

D

ST

Mat

eria

l Des

crip

tion:

D

uct S

eam

Tap

e F

riabl

e

Non

-Fria

ble

Siz

e:

2”

Prim

ary

Col

or:

Whi

te

Sec

onda

ry

Col

or:

N/A

Te

xtur

e:

Clo

th

Mat

eria

l Qua

ntity

: 15

0 S

F L

F E

AC

HE

stim

ated

By:

D

raw

ing

Fie

ld M

easu

re

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Thro

ugh-

out b

uild

ing

abov

e ce

iling

s

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A R

oom

15

SE

1 4

12

F - W

- C

- O

N

o N

one

dete

cted

B R

oom

16

SE

5 3

12

F - W

- C

- O

N

o N

one

dete

cted

C

Roo

m 1

7 SW

5

2 14

F

- W -

C -

O

No

Non

e de

tect

ed

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

2/09

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 49: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

11

M

ater

ial C

ode:

C

ON

M

ater

ial D

escr

iptio

n:

Con

cret

e (e

xter

ior s

idew

alks

) F

riabl

e

Non

-Fria

ble

Size

: N

/A

Prim

ary

Col

or:

Pin

k S

econ

dary

C

olor

: N

/A

Text

ure:

N

/A

Mat

eria

l Qua

ntity

: 3,

000

SF

LF

EA

CH

Est

imat

ed B

y:

Dra

win

g F

ield

Mea

sure

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Ext

erio

r sid

ewal

ks c

onne

ctin

g br

ick

pave

rs

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A

SW

of B

uild

ing

SW

3

0 0

F - W

- C

- O

N

o N

one

Det

ecte

d

B SW

of B

uild

ing

SW

12

0 0

F - W

- C

- O

N

o N

one

Det

ecte

d

C

SE o

f Bui

ldin

g SE

12

0

0 F

- W -

C -

O

No

Non

e D

etec

ted

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

17/0

9

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 50: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

12

M

ater

ial C

ode:

C

TG

Mat

eria

l Des

crip

tion:

C

eram

ic T

ile a

nd G

rout

F

riabl

e

Non

-Fria

ble

Siz

e:

4” x

4”

Prim

ary

Col

or:

Gre

y S

econ

dary

C

olor

: N

/A

Text

ure:

N

/A

Mat

eria

l Qua

ntity

: 21

6 S

F L

F E

AC

HE

stim

ated

By:

D

raw

ing

Fie

ld M

easu

re

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Roo

m’s

7 a

nd 8

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A R

oom

8

NE

2 0

1 F

- W -

C -

O

No

Non

e de

tect

ed –

cer

amic

tile

N

one

dete

cted

- gr

out

B R

oom

8

NE

2 0

1 F

- W -

C -

O

No

Non

e de

tect

ed –

cer

amic

tile

N

one

dete

cted

- gr

out

C

Roo

m 7

SE

2

0 1

F - W

- C

- O

N

o N

one

dete

cted

– c

eram

ic ti

le

Non

e de

tect

ed -

grou

t

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

2/09

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 51: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

13

M

ater

ial C

ode:

C

C

Mat

eria

l Des

crip

tion:

C

aulk

ing

Com

poun

d F

riabl

e

Non

-Fria

ble

Size

: N

/A

Prim

ary

Col

or:

Sem

i-cle

ar

Sec

onda

ry

Col

or:

N/A

Te

xtur

e:

N/A

Mat

eria

l Qua

ntity

: 75

S

F L

F E

AC

HE

stim

ated

By:

D

raw

ing

Fie

ld M

easu

re

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Roo

m’s

17,

18,

19

at p

lum

bing

fixt

ures

and

cou

nter

tops

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A R

oom

19

NE

2 0

3 F

- W -

C -

O

No

Non

e D

etec

ted

B R

oom

19

NE

0 1

3 F

- W -

C -

O

No

Non

e D

etec

ted

C

Roo

m 1

9 N

E 2

6 3

F - W

- C

- O

N

o N

one

Det

ecte

d

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

17/0

9

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 52: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

14

M

ater

ial C

ode:

C

C

Mat

eria

l Des

crip

tion:

C

aulk

ing

Com

poun

d F

riabl

e

Non

-Fria

ble

Size

: N

/A

Prim

ary

Col

or:

whi

te

Sec

onda

ry

Col

or:

N/A

Te

xtur

e:

N/A

Mat

eria

l Qua

ntity

: 10

S

F L

F E

AC

HE

stim

ated

By:

D

raw

ing

Fie

ld M

easu

re

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Roo

m 2

0 at

drin

king

foun

tain

s

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A R

oom

20

NW

4

22

3 F

- W -

C -

O

No

Non

e D

etec

ted

B R

oom

20

NW

4

23

3 F

- W -

C -

O

No

Non

e D

etec

ted

C

Roo

m 2

0 N

W

4 24

3

F - W

- C

- O

N

o N

one

Det

ecte

d

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

17/0

9

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 53: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

15

M

ater

ial C

ode:

B

&M

M

ater

ial D

escr

iptio

n:

Blo

ck a

nd M

orta

r F

riabl

e

Non

-Fria

ble

Size

: N

/A

Prim

ary

Col

or:

Gre

y S

econ

dary

C

olor

: N

/A

Text

ure:

N

/A

Mat

eria

l Qua

ntity

: 2,

700

SF

LF

EA

CH

Est

imat

ed B

y:

Dra

win

g F

ield

Mea

sure

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Ext

erio

r of b

uild

ing

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A

NO

T S

AM

PLE

D

F - W

- C

- O

B

F

- W -

C -

O

C

F

- W -

C -

O

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Mat

eria

l was

not

sam

pled

bec

ause

it w

ill no

t be

affe

cted

by

the

reno

vatio

ns

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

2/09

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 54: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

16

M

ater

ial C

ode:

C

TG

Mat

eria

l Des

crip

tion:

C

eram

ic T

ile a

nd G

rout

F

riabl

e

Non

-Fria

ble

Siz

e:

2” x

2”

Prim

ary

Col

or:

Gre

y S

econ

dary

C

olor

: N

/A

Text

ure:

N

/A

Mat

eria

l Qua

ntity

: 12

0 S

F L

F E

AC

HE

stim

ated

By:

D

raw

ing

Fie

ld M

easu

re

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Roo

m’s

7 a

nd 8

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A

NO

T S

AM

PLE

D

F - W

- C

- O

B

F

- W -

C -

O

C

F

- W -

C -

O

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Mat

eria

l was

not

sam

pled

bec

ause

it w

ill no

t be

affe

cted

by

the

reno

vatio

ns

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

2/09

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 55: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

FGIS

-EN

V-M

ater

ials

ampl

eshe

et-0

7.do

c

Pag

e __

_ of

___

Proj

ect N

o.:

CO

P09

028

Clie

nt:

City

of P

hoen

ix

301

N. 1

st A

venu

e B

uild

ing:

C

entra

l Sta

tion

Hom

ogen

eous

A

rea:

17

M

ater

ial C

ode:

FS

M

ater

ial D

escr

iptio

n:

Fram

e S

eala

nt

Fria

ble

N

on-F

riabl

e

Size

: N

/A

Prim

ary

Col

or:

Gre

y S

econ

dary

C

olor

: N

/A

Text

ure:

N

/A

Mat

eria

l Qua

ntity

: 25

2 S

F L

F E

AC

HE

stim

ated

By:

D

raw

ing

Fie

ld M

easu

re

Hom

ogen

eous

Mat

eria

l Lo

catio

n:

Ext

erio

r of w

indo

ws

and

door

s th

roug

h bl

ock

wal

ls

Sam

ple

No.

Fu

nctio

nal S

pace

O

rigin

Ea

st/W

est

Dim

ensi

on

Nor

th/S

outh

D

imen

sion

H

eigh

t A

.F.F

. Su

rfac

e A

CM

? A

sbes

tos

Perc

ent a

nd T

ype

A

NO

T S

AM

PLE

D

F - W

- C

- O

B

F

- W -

C -

O

C

F

- W -

C -

O

D

F

- W -

C -

O

E

F

- W -

C -

O

F

F - W

- C

- O

G

F

- W -

C -

O

Com

men

ts:

Mat

eria

l was

not

sam

pled

bec

ause

it w

ill no

t be

affe

cted

by

the

reno

vatio

ns

Insp

ecto

r:

Mat

t Val

enti

D

ate:

6/

2/09

Insp

ecto

r

D

ate:

Cer

t. N

o.:

E10

07

St

ate:

A

Z

Cer

t No.

:

St

ate:

Sign

atur

e:

Exp

Dat

e:

9/5/

09

Si

gnat

ure:

Ex

p D

ate:

Mat

eria

l Sam

ple

Shee

t

Page 56: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is
Page 57: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is
Page 58: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is
Page 59: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

APPENDIX B

Chain of Custody

Laboratory PLM Analysis Summary Laboratory Approved Accreditation Signature

PLM Analysis Detail Sheets

Page 60: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is
Page 61: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is
Page 62: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is
Page 63: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

PLM REPORT SUMMARY

Cates Laboratories NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Lab Job No.: PLM-02904

Project: 301 N. 1st Avenue, Phoenix, AZ Report Date: 6/11/2009

Project No: COP09028 Sample Date: 6/2/2009

Identification: Asbestos, Bulk Sample Analysis

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 1 of 3

On 6/4/2009, thirty (30) bulk samples were submitted by Mr. Matt Valenti of Facility GIS for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Lab

Sample No.

Client

Field I.D.

Sample Description/Location Asbestos Content

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing

only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing

Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

except in full.

CL134945 01A Vinyl Sheet Flooring - Room 4 None Detected - Sheet Flooring None Detected - Yellow Mastic

CL134946 01B Vinyl Sheet Flooring - Room 1 None Detected - Sheet Flooring None Detected - Yellow Mastic

CL134947 01C Vinyl Sheet Flooring - Room 3 None Detected - Sheet Flooring None Detected - Yellow Mastic

CL134948 02A Ceramic Tile and Grout - Room 5 None Detected - Ceramic Tile None Detected - Grout

CL134949 02B Ceramic Tile and Grout - Room 5 None Detected - Ceramic Tile None Detected - Grout

CL134950 02C Ceramic Tile and Grout - Room 11 None Detected - Ceramic Tile None Detected - Grout

CL134951 03A Cove Base and Mastic - Room 4 None Detected

CL134952 03B Cove Base and Mastic - Room 1 None Detected

CL134953 03C Cove Base and Mastic - Room 3 None Detected

CL134954 04A Texture (on wallboard) - Room 4 None Detected

CL134955 04B Texture (on wallboard) - Room 5 None Detected

CL134956 04C Texture (on wallboard) - Room 11 None Detected

CL134957 05A Gypsum Wallboard - Room 4 None Detected - Paper None Detected - Wallboard Material

CL134958 05B Gypsum Wallboard - Room 5 None Detected - Paper None Detected - Wallboard Material

CL134959 05C Gypsum Wallboard - Room 11 None Detected - Paper None Detected - Wallboard Material

CL134960 06A Acoustical Ceiling Panel - Room 4 None Detected

Page 64: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

PLM REPORT SUMMARY

Cates Laboratories NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Lab Job No.: PLM-02904

Project: 301 N. 1st Avenue, Phoenix, AZ Report Date: 6/11/2009

Project No: COP09028 Sample Date: 6/2/2009

Identification: Asbestos, Bulk Sample Analysis

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 2 of 3

On 6/4/2009, thirty (30) bulk samples were submitted by Mr. Matt Valenti of Facility GIS for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Lab

Sample No.

Client

Field I.D.

Sample Description/Location Asbestos Content

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing

only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing

Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

except in full.

CL134961 06B Acoustical Ceiling Panel - Room 5 None Detected

CL134962 06C Acoustical Ceiling Panel - Room 10 None Detected

CL134963 07A Cove Base and Mastic - Room 5 None Detected

CL134964 07B Cove Base and Mastic - Room 6 None Detected

CL134965 07C Cove Base and Mastic - Room 10 None Detected

CL134966 08A Texture (on wallboard) - Room 14 None Detected

CL134967 08B Texture (on wallboard) - Room 15 None Detected

CL134968 08C Texture (on wallboard) - Room 15 None Detected

CL134969 09A Gypsum Wallboard - Room 14 None Detected - Wallboard Material

CL134970 09B Gypsum Wallboard - Room 15 None Detected - Paper None Detected - Wallboard Material

CL134971 09C Gypsum Wallboard - Room 15 None Detected - Paper None Detected - Wallboard Material

CL134972 10A Duct Seam Tape - Room 15 None Detected

CL134973 10B Duct Seam Tape - Room 16 None Detected

CL134974 10C Duct Seam Tape - Room 17 None Detected

Page 65: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

PLM REPORT SUMMARY

Cates Laboratories NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Lab Job No.: PLM-02904

Project: 301 N. 1st Avenue, Phoenix, AZ Report Date: 6/11/2009

Project No: COP09028 Sample Date: 6/2/2009

Identification: Asbestos, Bulk Sample Analysis

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 3 of 3

On 6/4/2009, thirty (30) bulk samples were submitted by Mr. Matt Valenti of Facility GIS for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein.

STATEMENT OF LABORATORY ACCREDITATION

The samples were analyzed in general accordance with the procedures outlined in the Method for the

Determination of Asbestos in Bulk Building Materials, EPA/600/R-93/116 or the U.S. Environmental

Protection Agency method, under AHERA, for the analysis of asbestos in building materials by polarized light

microscopy. The results of each bulk sample relate only to the material tested and the results shall not be used

to claim product endorsement by NVLAP or any agency of the U.S. Government.

Specific questions concerning bulk sample results shall be directed to the Laboratory Director.

Analyst: Kathy Schosek

Laboratory Director: John R. Cates, P.G.

Approved Signatory:

Page 66: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

PLM REPORT SUMMARY

Cates Laboratories NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Lab Job No.: PLM-02904

Project: 301 N. 1st Avenue, Phoenix, AZ Report Date: 6/22/2009

Project No: COP09028 Sample Date: 6/17/2009

Identification: Asbestos, Bulk Sample Analysis

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 1 of 2

On 6/20/2009, twelve (12) bulk samples were submitted by Mr. Matt Valenti of Facility GIS for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Lab

Sample No.

Client

Field I.D.

Sample Description/Location Asbestos Content

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing

only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing

Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

except in full.

CL135459 11A Concrete - Exterior None Detected

CL135460 11B Concrete - Exterior None Detected

CL135461 11C Concrete - Exterior None Detected

CL135462 12A Ceramic Tile & Grout - Room 8 None Detected - Ceramic Tile None Detected - Grout

CL135463 12B Ceramic Tile & Grout - Room 8 None Detected - Ceramic Tile None Detected - Grout

CL135464 12C Ceramic Tile & Grout - Room 7 None Detected - Ceramic Tile None Detected - Grout

CL135465 13A Caulking Compound - Room 19 None Detected

CL135466 13B Caulking Compound - Room 19 None Detected

CL135467 13C Caulking Compound - Room 19 None Detected

CL135468 14A Caulking Compound - Room 20 None Detected

CL135469 14B Caulking Compound - Room 20 None Detected

CL135470 14C Caulking Compound - Room 20 None Detected

Page 67: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

PLM REPORT SUMMARY

Cates Laboratories NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Lab Job No.: PLM-02904

Project: 301 N. 1st Avenue, Phoenix, AZ Report Date: 6/22/2009

Project No: COP09028 Sample Date: 6/17/2009

Identification: Asbestos, Bulk Sample Analysis

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 2 of 2

On 6/20/2009, twelve (12) bulk samples were submitted by Mr. Matt Valenti of Facility GIS for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein.

STATEMENT OF LABORATORY ACCREDITATION

The samples were analyzed in general accordance with the procedures outlined in the Method for the

Determination of Asbestos in Bulk Building Materials, EPA/600/R-93/116 or the U.S. Environmental

Protection Agency method, under AHERA, for the analysis of asbestos in building materials by polarized light

microscopy. The results of each bulk sample relate only to the material tested and the results shall not be used

to claim product endorsement by NVLAP or any agency of the U.S. Government.

Specific questions concerning bulk sample results shall be directed to the Laboratory Director.

Analyst: Kathy Schosek

Laboratory Director: John R. Cates, P.G.

Approved Signatory:

Page 68: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is
Page 69: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is
Page 70: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134945 Field ID #: 01A

Client Sample Description: Vinyl Sheet Flooring - Room 4

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134945

kkkx Layer 1 Sheet Flooring Stereoscopic Examination 134945 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Grey Rubbery Yes ND ND 95 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Vinyl Binders 100 Non-fibrous 1

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Yellow Mastic Stereoscopic Examination 134945 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 Yellow-Tan Rubbery Yes ND ND 5 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Glue Binders 100 0 Non-fibrous 2

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 71: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134946 Field ID #: 01B

Client Sample Description: Vinyl Sheet Flooring - Room 1

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134946

kx Layer 1 Sheet Flooring Stereoscopic Examination 134946 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Brown Rubbery Yes ND ND 95 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Vinyl Binders 100 Non-fibrous 1

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Yellow Mastic Stereoscopic Examination 134946 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 Yellow-Tan Rubbery Yes ND ND 5 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Glue Binders 100 0 Non-fibrous 2

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 72: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134947 Field ID #: 01C

Client Sample Description: Vinyl Sheet Flooring - Room 3

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134947

kx Layer 1 Sheet Flooring Stereoscopic Examination 134947 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Brown Rubbery Yes ND ND 95 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Vinyl Binders 100 Non-fibrous 1

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Yellow Mastic Stereoscopic Examination 134947 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 Yellow-Tan Rubbery Yes ND ND 5 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Glue Binders 100 0 Non-fibrous 2

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 73: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134948 Field ID #: 02A

Client Sample Description: Ceramic Tile and Grout - Room 5

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134948

kx Layer 1 Ceramic Tile Stereoscopic Examination 134948 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Grey Hard Yes ND ND 70 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Sintered Clays 100 Non-fibrous 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Grout Stereoscopic Examination 134948 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 Grey Cementitious Yes ND ND 30 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 65 Non-fibrous 2 Cement Binders 35 Non-fibrous 2

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 74: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134949 Field ID #: 02B

Client Sample Description: Ceramic Tile and Grout - Room 5

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134949

kx Layer 1 Ceramic Tile Stereoscopic Examination 134949 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Grey Hard Yes ND ND 70 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Sintered Clays 100 Non-fibrous 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Grout Stereoscopic Examination 134949 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 Grey Cementitious Yes ND ND 30 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 65 Non-fibrous 2 Cement Binders 35 Non-fibrous 2

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 75: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134950 Field ID #: 02C

Client Sample Description: Ceramic Tile and Grout - Room 11

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134950

kx Layer 1 Ceramic Tile Stereoscopic Examination 134950 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Grey Hard Yes ND ND 70 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Sintered Clays 100 Non-fibrous 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Grout Stereoscopic Examination 134950 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 Grey Cementitious Yes ND ND 30 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 65 Non-fibrous 2 Cement Binders 35 Non-fibrous 2

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 76: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134951 Field ID #: 03A

Client Sample Description: Cove Base and Mastic - Room 4

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134951

kx Layer 1 Cove Base Stereoscopic Examination 134951 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Grey Rubbery Yes ND ND 95 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Vinyl Binders 100 Non-fibrous 1

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Yellow Mastic Stereoscopic Examination 134951 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 Yellow-Tan Rubbery Yes ND ND 5 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Glue Binders 100 0 Non-fibrous 2

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 77: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134952 Field ID #: 03B

Client Sample Description: Cove Base and Mastic - Room 1

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134952

kx Layer 1 Cove Base Stereoscopic Examination 134952 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Grey Rubbery Yes ND ND 95 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Vinyl Binders 100 Non-fibrous 1

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Yellow Mastic Stereoscopic Examination 134952 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 Yellow-Tan Rubbery Yes ND ND 5 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Glue Binders 100 0 Non-fibrous 2

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 78: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134953 Field ID #: 03C

Client Sample Description: Cove Base and Mastic - Room 3

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134953

kx Layer 1 Cove Base Stereoscopic Examination 134953 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Grey Rubbery Yes ND ND 95 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Vinyl Binders 100 Non-fibrous 1

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Yellow Mastic Stereoscopic Examination 134953 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 Yellow-Tan Rubbery Yes ND ND 5 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Glue Binders 100 0 Non-fibrous 2

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 79: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134954 Field ID #: 04A

Client Sample Description: Texture (on wallboard) - Room 4

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134954

kx Layer 1 Paint Texture Stereoscopic Examination 134954 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 White Blocky Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders/Paint 100 Non-fibrous 1

Prep/treatment: solvent dissolution Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 80: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134955 Field ID #: 04B

Client Sample Description: Texture (on wallboard) - Room 5

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134955

kx Layer 1 Paint Texture Stereoscopic Examination 134955 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 White Blocky Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders/Paint 100 Non-fibrous 1

Prep/treatment: solvent dissolution Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 81: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134956 Field ID #: 04C

Client Sample Description: Texture (on wallboard) - Room 11

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134956

kx Layer 1 Paint Texture Stereoscopic Examination 134956 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 White Blocky Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders/Paint 100 Non-fibrous 1

Prep/treatment: solvent dissolution Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 82: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134957 Field ID #: 05A

Client Sample Description: Gypsum Wallboard - Room 4

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134957

kx Layer 1 Paper Stereoscopic Examination 134957 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Tan Fibrous Yes 100 ND 10 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Cellulose Fibers 100 ribbons high 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Wallboard Material Stereoscopic Examination 134957 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 White Blocky Yes 1 ND 90 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 4 Non-fibrous 2 Glass Fibers 1 straight none none 2 Gypsum Binders 95 Non-fibrous 2

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 83: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134958 Field ID #: 05B

Client Sample Description: Gypsum Wallboard - Room 5

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134958

kx Layer 1 Paper Stereoscopic Examination 134958 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Tan Fibrous Yes 100 ND 10 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Cellulose Fibers 100 ribbons high 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Wallboard Material Stereoscopic Examination 134958 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 White Blocky Yes 1 ND 90 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 4 Non-fibrous 2 Glass Fibers 1 straight none none 2 Gypsum Binders 95 Non-fibrous 2

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 84: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134959 Field ID #: 05C

Client Sample Description: Gypsum Wallboard - Room 11

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134959

kx Layer 1 Paper Stereoscopic Examination 134959 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Tan Fibrous Yes 100 ND 10 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Cellulose Fibers 100 ribbons high 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Wallboard Material Stereoscopic Examination 134959 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 White Blocky Yes 1 ND 90 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 4 Non-fibrous 2 Glass Fibers 1 straight none none 2 Gypsum Binders 95 Non-fibrous 2

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 85: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134960 Field ID #: 06A

Client Sample Description: Acoustical Ceiling Panel - Room 4

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134960

kx Layer 1 Ceiling Tile Stereoscopic Examination 134960 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Beige w/wht pt Fibrous Yes 60 ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Binders / Paint 10 Non-fibrous 1 Cellulose Fibers 55 ribbons high 1 Mineral Wool Fibers 5 Rods 0 1 Perlite 30 Glass Foam 0 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 86: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134961 Field ID #: 06B

Client Sample Description: Acoustical Ceiling Panel - Room 5

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134961

kx Layer 1 Ceiling Tile Stereoscopic Examination 134961 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Beige w/wht pt Fibrous Yes 60 ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Binders / Paint 10 Non-fibrous 1 Cellulose Fibers 55 ribbons high 1 Mineral Wool Fibers 5 Rods 0 1 Perlite 30 Glass Foam 0 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 87: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134962 Field ID #: 06C

Client Sample Description: Acoustical Ceiling Panel - Room 10

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134962

kx Layer 1 Ceiling Tile Stereoscopic Examination 134962 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Beige w/wht pt Fibrous Yes 60 ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Binders / Paint 10 Non-fibrous 1 Cellulose Fibers 55 ribbons high 1 Mineral Wool Fibers 5 Rods 0 1 Perlite 30 Glass Foam 0 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 88: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134963 Field ID #: 07A

Client Sample Description: Cove Base and Mastic - Room 5

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134963

kx Layer 1 Cove Base Stereoscopic Examination 134963 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Brown Rubbery Yes ND ND 90 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Vinyl Binders 100 Non-fibrous 1

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Mastic Stereoscopic Examination 134963 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 Cream Rubbery Yes ND ND 10 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders 100 Non-fibrous 2

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 89: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134964 Field ID #: 07B

Client Sample Description: Cove Base and Mastic - Room 6

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134964

kx Layer 1 Cove Base Stereoscopic Examination 134964 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Brown Rubbery Yes ND ND 90 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Vinyl Binders 100 Non-fibrous 1

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Mastic Stereoscopic Examination 134964 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 Cream Rubbery Yes ND ND 10 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders 100 Non-fibrous 2

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 90: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134965 Field ID #: 07C

Client Sample Description: Cove Base and Mastic - Room 10

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134965

kx Layer 1 Cove Base Stereoscopic Examination 134965 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Brown Rubbery Yes ND ND 90 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Vinyl Binders 100 Non-fibrous 1

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Mastic Stereoscopic Examination 134965 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 Cream Rubbery Yes ND ND 10 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders 100 Non-fibrous 2

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 91: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134966 Field ID #: 08A

Client Sample Description: Texture (on wallboard) - Room 14

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134966

kx Layer 1 Paint Texture Stereoscopic Examination 134966 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 White Blocky Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders/Paint 100 Non-fibrous 1

Prep/treatment: solvent dissolution Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 92: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134967 Field ID #: 08B

Client Sample Description: Texture (on wallboard) - Room 15

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134967

kx Layer 1 Paint Texture Stereoscopic Examination 134967 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 White Blocky Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders/Paint 100 Non-fibrous 1

Prep/treatment: solvent dissolution Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 93: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134968 Field ID #: 08C

Client Sample Description: Texture (on wallboard) - Room 15

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134968

kx Layer 1 Paint Texture Stereoscopic Examination 134968 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 White Blocky Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders/Paint 100 Non-fibrous 1

Prep/treatment: solvent dissolution Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 94: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134969 Field ID #: 09A

Client Sample Description: Gypsum Wallboard - Room 14

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134969

kx Layer 1 Wallboard Material Stereoscopic Examination 134969 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 White Blocky Yes 1 ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 4 Non-fibrous 1 Glass Fibers 1 ribbons high 1 Gypsum Binders 95 Non-fibrous 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 95: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134970 Field ID #: 09B

Client Sample Description: Gypsum Wallboard - Room 15

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134970

kx Layer 1 Paper Stereoscopic Examination 134970 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Tan Fibrous Yes 100 ND 10 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Cellulose Fibers 100 ribbons high 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Wallboard Material Stereoscopic Examination 134970 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 White Blocky Yes 1 ND 90 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 4 Non-fibrous 2 Glass Fibers 1 straight none none 2 Gypsum Binders 95 Non-fibrous 2

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 96: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134971 Field ID #: 09C

Client Sample Description: Gypsum Wallboard - Room 15

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134971

kx Layer 1 Paper Stereoscopic Examination 134971 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Tan Fibrous Yes 100 ND 10 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Cellulose Fibers 100 ribbons high 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Wallboard Material Stereoscopic Examination 134971 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 White Blocky Yes 1 ND 90 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 4 Non-fibrous 2 Glass Fibers 1 straight none none 2 Gypsum Binders 95 Non-fibrous 2

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 97: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134972 Field ID #: 10A

Client Sample Description: Duct Seam Tape - Room 15

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134972

kx Layer 1 Seam Tape/Mastic Stereoscopic Examination 134972 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 White Fibrous Yes 20 ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders 80 0 Non-fibrous 1 Cotton Fibers 20 Twisted Ribbons high 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 98: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134973 Field ID #: 10B

Client Sample Description: Duct Seam Tape - Room 16

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134973

kx Layer 1 Seam Tape/Mastic Stereoscopic Examination 134973 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 White Fibrous Yes 20 ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders 80 0 Non-fibrous 1 Cotton Fibers 20 Twisted Ribbons high 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 99: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL134974 Field ID #: 10C

Client Sample Description: Duct Seam Tape - Room 17

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/10/2009

Lab Job #: PLM-02904 Sample #: CL134974

kx Layer 1 Seam Tape/Mastic Stereoscopic Examination 134974 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 White Fibrous Yes 20 ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders 80 0 Non-fibrous 1 Cotton Fibers 20 Twisted Ribbons high 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 100: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL135459 Field ID #: 11A

Client Sample Description: Concrete - Exterior

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/22/2009

Lab Job #: PLM-02904 Sample #: CL135459

kkkx Layer 1 Concrete Stereoscopic Examination 135459 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Pink Cementitious Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 60 Non-fibrous 1 Cement Binders 40 Non-fibrous 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 101: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL135460 Field ID #: 11B

Client Sample Description: Concrete - Exterior

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/22/2009

Lab Job #: PLM-02904 Sample #: CL135460

kx Layer 1 Concrete Stereoscopic Examination 135460 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Pink Cementitious Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 60 Non-fibrous 1 Cement Binders 40 Non-fibrous 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 102: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL135461 Field ID #: 11C

Client Sample Description: Concrete - Exterior

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/22/2009

Lab Job #: PLM-02904 Sample #: CL135461

kx Layer 1 Concrete Stereoscopic Examination 135461 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Pink Cementitious Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 60 Non-fibrous 1 Cement Binders 40 Non-fibrous 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 103: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL135462 Field ID #: 12A

Client Sample Description: Ceramic Tile & Grout - Room 8

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/22/2009

Lab Job #: PLM-02904 Sample #: CL135462

kx Layer 1 Ceramic Tile Stereoscopic Examination 135462 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Lt. Grey Hard Yes ND ND 70 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Sintered Clays 100 Non-fibrous 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Grout Stereoscopic Examination 135462 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 White Cementitious Yes ND ND 30 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 65 Non-fibrous 2 Cement Binders 35 Non-fibrous 2

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 104: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL135463 Field ID #: 12B

Client Sample Description: Ceramic Tile & Grout - Room 8

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/22/2009

Lab Job #: PLM-02904 Sample #: CL135463

kx Layer 1 Ceramic Tile Stereoscopic Examination 135463 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Lt. Grey Hard Yes ND ND 70 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Sintered Clays 100 Non-fibrous 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Grout Stereoscopic Examination 135463 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 Grey Cementitious Yes ND ND 30 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 65 Non-fibrous 2 Cement Binders 35 Non-fibrous 2

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 105: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL135464 Field ID #: 12C

Client Sample Description: Ceramic Tile & Grout - Room 7

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/22/2009

Lab Job #: PLM-02904 Sample #: CL135464

kx Layer 1 Ceramic Tile Stereoscopic Examination 135464 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Lt. Grey Hard Yes ND ND 70 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Sintered Clays 100 Non-fibrous 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __

Layer 2 Grout Stereoscopic Examination 135464 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 2 Grey Cementitious Yes ND ND 30 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate 65 Non-fibrous 2 Cement Binders 35 Non-fibrous 2

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 106: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL135465 Field ID #: 13A

Client Sample Description: Caulking Compound - Room 19

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/22/2009

Lab Job #: PLM-02904 Sample #: CL135465

kx Layer 1 Caulking Stereoscopic Examination 135465 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Clear Rubbery Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Binders 100 Non-fibrous 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 107: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL135466 Field ID #: 13B

Client Sample Description: Caulking Compound - Room 19

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/22/2009

Lab Job #: PLM-02904 Sample #: CL135466

kx Layer 1 Caulking Stereoscopic Examination 135466 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Clear Rubbery Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Binders 100 Non-fibrous 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 108: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL135467 Field ID #: 13C

Client Sample Description: Caulking Compound - Room 19

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/22/2009

Lab Job #: PLM-02904 Sample #: CL135467

kx Layer 1 Caulking Stereoscopic Examination 135467 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 Clear Rubbery Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Binders 100 Non-fibrous 1

Prep/treatment: mechanical separation Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 109: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL135468 Field ID #: 14A

Client Sample Description: Caulking Compound - Room 20

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/22/2009

Lab Job #: PLM-02904 Sample #: CL135468

kx Layer 1 Caulking Stereoscopic Examination 135468 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 White Rubbery Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders 100 Non-fibrous 1

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 110: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL135469 Field ID #: 14B

Client Sample Description: Caulking Compound - Room 20

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/22/2009

Lab Job #: PLM-02904 Sample #: CL135469

kx Layer 1 Caulking Stereoscopic Examination 135469 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 White Rubbery Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders 100 Non-fibrous 1

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 111: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

Bulk Asbestos Analysis Sheet

Cates Laboratories EPA Method 600/R-93/116 NVLAP Lab No. 200569-0

613 S. Bois D’Arc TDH License No. 30-0287

Forney, Texas 75126 (972) 564-4723

Client: Facility GIS Page 1 of 1

Project: 301 N. 1st Avenue, Phoenix, AZ

Project # COP09028 Sample #: CL135470 Field ID #: 14C

Client Sample Description: Caulking Compound - Room 20

Comments: Analyst: Kathy Schosek

Date Analyzed: 6/22/2009

Lab Job #: PLM-02904 Sample #: CL135470

kx Layer 1 Caulking Stereoscopic Examination 135470 Color Texture Homogeneous? % Fibrous % Asbestos % of Sample 1 White Rubbery Yes ND ND 100 PLM Examination: Color/ Parallel Perpendicular Extinction Sign of Components % +/- Morphology Pleochroism Ref. Index Ref. Index Biref Angle Elongation Aggregate/Binders 100 Non-fibrous 1

Prep/treatment: heat / melt Asbestos Content: None Detected

__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ zzz

Page 112: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

APPENDIX C

NESHAP Notification Information

Personnel Certifications

Page 113: Updated Central Station Report of findings · Central Station July 19, 2010 MACTEC Project No. 4972-10-3001.01 Updated Report of Findings 2 PROJECT INFORMATION The property that is

NESHAP NOTIFICATION INFORMATION Property Owner...............................................................................................City of Phoenix Address .........................................................................................300 North Central Avenue

Phoenix, Arizona Survey Date ................................................................................................ 6/2/09 and 6/17/09 Number of Bulk Samples Collected .......................................................................... 42 PLM Date of Analysis....................................................................................... 6/10/09 and 6/22/09 Lab Performing Analysis ........................................................................ Cates Laboratories Survey Inspectors .................................................................................................................. 1 FGIS Project Number ............................................................................................. COP09028

Inspector Cert. No. Expiration Training Center

Matt Valenti E1007 9/5/09 The Asbestos Institute

No Asbestos Containing Materials were found during this Limited Asbestos Survey