6
Universal Stopper Install STI-13000 & STI-14000 Series Rely on STI ® Specifications Polycarbonate Enclosure · Flammability - flush and surface mount models (Fig. 2, 3 & 4): UL 94 V-2, enclosed flush and enclosed back box models (Fig. 5 & 6): UL 94 5VA · Cover wall thickness 0.125 inches Dry Contact Relay · 30 VAC/VDC, 1A Temperature Range · Electronics operating range: -40° to 120°F (-40° to 49°C) Below -4°F (-20°C), a remote power source is recommended · Polycarbonate rated: -40° to 284°F (-40° to 140°C) Installation Notes · When used outdoors, the manual station must also be rated for outdoor use. · UL Listing does not permit external power source or connection of horn relay contacts to fire alarm or life safety devices. · When properly installed, the operation of this cover will not interfere with the function of your life safety system. · Horn operation and performance must be tested annually. Battery replacement is recommended annually dependent on usage and battery expiration date. · Ensure the service pin is properly inserted in the service pin receptor to silence horn while performing installation or servicing horn. · If mounting to an uneven surface, a backplate (STI-1314) is recommended to help ensure proper sealing to mounting surface. · The backplate may be drilled if wire access or screw mounting holes are needed. Approvals It has been tested and approved or listed by: · UL, CUL Listed - S2466 · UL Certified to meet ADA · NEMA Type 3RX models with enclosed flush mount and enclosed back box options Polycarbonate Cleaning Instructions Rinse with water to remove abrasive dust and dirt. Wash with soap or mild detergent, using a soft cloth. Rinse once more then dry with a soft cloth or chamois. Exercise caution when using water inside enclosure. Make sure unit is completely dry inside before reassembling. To remove grease or wet paint from exterior of cover, rub gently with a soft cloth thoroughly wetted with Naptha. Then wash and rinse. Do not use razor blades. LIFT HERE TEXT HERE 5.95 in. (151mm) 6.80 in. (172mm) 5.7 in. (144mm) 3.83 in. (97mm) 4.08 in. (103mm) 4.90 in. (124mm) 5.70 in. (144mm) LOCKING TAB Fig. 1 - Dimensions Center pull station to the Universal Stopper with the help of dimensions shown in Fig. 1. Open cover, use frame or optional backplate to mark mounting holes. NOTE: Be sure the entire cover travel will not interfere with operation of the pull station or other safety system equipment when installed. Horn (battery included) current draw dBA @ 9VDC STI-13*20 & STI-13*30 models 9vdc 12vdc 24vdc 1 ft. 3 ft. 10 ft. Low volume 36 mA 42 mA 22 mA 98 87 75 High volume 155 mA 146 mA 95 mA 108 93 82 Standby current 0.03 mA 0.64 mA 1.9 mA - - - current draw dBA @ 3VDC STI-14*20 & STI-14*30 models 3vdc 12vdc 24vdc 1 ft. 3 ft. 10 ft. Low volume 60 mA 46 mA 25 mA 84 74 62 High volume 140 mA 87 mA 45 mA 95 85 76 Standby current 0.04 mA 0.10 mA 0.014 mA - - - See website for accessories

Transcript of Universal Stopper Install STI-13000 & STI-14000 Series

Page 1: Universal Stopper Install STI-13000 & STI-14000 Series

Universal Stopper InstallSTI-13000 & STI-14000 Series

Rely on STI®

SpecificationsPolycarbonate Enclosure· Flammability - flush and surface mount models (Fig. 2, 3 & 4): UL 94 V-2, enclosed flush and enclosed back box models (Fig. 5 & 6): UL 94 5VA· Cover wall thickness 0.125 inches

Dry Contact Relay· 30 VAC/VDC, 1A

Temperature Range· Electronics operating range: -40° to 120°F (-40° to 49°C) Below -4°F (-20°C), a remote power source is recommended· Polycarbonate rated: -40° to 284°F (-40° to 140°C)

Installation Notes· When used outdoors, the manual station must also be rated for outdoor use.· UL Listing does not permit external power source or connection of horn relay contacts to fire alarm or life safety devices.· When properly installed, the operation of this cover will not interfere with the function of your life safety system.· Horn operation and performance must be tested annually. Battery replacement is recommended annually dependent on usage and

battery expiration date.· Ensure the service pin is properly inserted in the service pin receptor to silence horn while performing installation or servicing horn.· If mounting to an uneven surface, a backplate (STI-1314) is recommended to help ensure proper sealing to mounting surface. · The backplate may be drilled if wire access or screw mounting holes are needed.

ApprovalsIt has been tested and approved or listed by:· UL, CUL Listed - S2466· UL Certified to meet ADA· NEMA Type 3RX models with enclosed flush mount and enclosed back box options

Polycarbonate Cleaning InstructionsRinse with water to remove abrasive dust and dirt. Wash with soap or mild detergent, using a soft cloth. Rinse once more then dry with a soft cloth or chamois. Exercise caution when using water inside enclosure. Make sure unit is completely dry inside before reassembling. To remove grease or wet paint from exterior of cover, rub gently with a soft cloth thoroughly wetted with Naptha. Then wash and rinse. Do not use razor blades.

4.08 in.(104mm)

5.42 in.(138mm)

4.96 in.(126mm)

4.31 in.(110mm)

3.25 in.(83mm)

2.54 in.(84mm)

2.66 in.(68mm)

2.0 in.(51mm)

1.5 in.(38mm)

1.0 in.(25mm)

FLUSH END VIEW

.67 in.(17mm)

5.95 in.(151mm)WITHOUT HORN

5.28 in.(134mm)WITH HORN

.42 in.(11mm)

5.42 in.(138mm)WITH HORN

6.36 in.(162mm)WITHOUT HORN

FLUSH SIDE VIEW

LIFT HERE

TEXT HERE

5.950 in.(151.13mm)

6.798 in.(172.68mm)

5.7 in.(144.78mm)

3.83 in.(97.28mm)

4.08 in.(103.63mm)

4.898 in.(124.42mm)

5.699 in.(144.75mm)

LIFT HERE

TEXT HERE

5.950 in.(151.13mm)

6.798 in.(172.68mm)

5.7 in.(144.78mm)

3.83 in.(97.28mm)

4.08 in.(103.63mm)

4.898 in.(124.42mm)

5.699 in.(144.75mm)

LOCKINGTAB

LIFT HERE

TEXT HERE

5.95 in.(151mm)

6.80 in.(172mm)5.7 in.

(144mm)

3.83 in.(97mm)

4.08 in.(103mm)

4.90 in.(124mm)

5.70 in.(144mm)

LOCKING TAB

Fig. 1 - Dimensions Center pull station to the Universal Stopper with the help of dimensions shown in Fig. 1.

Open cover, use frame or optional backplate to mark mounting holes.

NOTE: Be sure the entire cover travel will not interfere with operation of the pull station or other safety system equipment when installed.

Horn (battery included) current draw dBA @ 9VDC STI-13*20 & STI-13*30 models 9vdc 12vdc 24vdc 1 ft. 3 ft. 10 ft. Low volume 36 mA 42 mA 22 mA 98 87 75 High volume 155 mA 146 mA 95 mA 108 93 82 Standby current 0.03 mA 0.64 mA 1.9 mA - - - current draw dBA @ 3VDC STI-14*20 & STI-14*30 models 3vdc 12vdc 24vdc 1 ft. 3 ft. 10 ft. Low volume 60 mA 46 mA 25 mA 84 74 62 High volume 140 mA 87 mA 45 mA 95 85 76 Standby current 0.04 mA 0.10 mA 0.014 mA - - -

See website for accessories

Page 2: Universal Stopper Install STI-13000 & STI-14000 Series

Fig. 2 - Flush Mounting Option - Models 130** & 140**

Fig. 4 - Surface Mounting Option - Models 132** & 142**

DRILL 3/16 DIA. HOLES 1-1/4 in. DEEP WHENUSING ANCHORS

DRILL 7/64 DIA. HOLES 1-1/4 in. DEEP WHENANCHORS ARE NOT USED

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

#6 x 1-1/4 in. SCREW(4) PROVIDED

STI-1314 OPTIONAL BACKPLATE -RECOMMENDED WHEN MOUNTING TO UNEVEN SURFACE

#6 x 1-1/4 in. SCREW(4) PROVIDED

1/2 in. & 3/4 in. CONDUITWEATHER GASKET

STI-1314 OPTIONAL BACKPLATE -RECOMMENDED WHEN MOUNTING TO UNEVEN SURFACE

DRILL 3/16 DIA. HOLES1-1/4 in. DEEP WHENUSING ANCHORS

DRILL 7/64 DIA. HOLES1-1/4 in. DEEP WHENANCHORS ARE NOT USED

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT USED ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

STI-1401 GASKET

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED.INSERT THE BREAKAWAY SEAL (KIT-65)COMPLETELY INTO THE LOCKING TAB.*NOT USED ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

DRILL 3/16 DIA. HOLES1-1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES1-1/4 in. DEEP WHEN ANCHORS ARE NOT USED

#6 x 1-1/4 in. SCREW(4) PROVIDED

IP67 GROMMET FOR REMOTE CABLE OPTIONDRILL 5/8 in. (16mm)

(INCLUDED WITH REMOTE OPTION)DRILL POINT CENTER LOCATED ON

BACK SIDE OF MOUNTING PLATE

DRILL 3/16 DIA. HOLES 1-1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES 1-1/4 in. DEEP WHEN ANCHORS ARE NOT USED

#6 x 1-1/4 in. SCREW(4) PROVIDED

#6 - 32 x 1/2 in. PHIL. PANHEAD SCREW(2) PROVIDED SEALED MOUNTING PLATE (SHOWN)

LOCATE GROMET AS NEEDEDDRILL 5/8 in (16mm) HOLEINSERT GROMET AS SHOWN

FEED WIRES THROUGH GROMET(INCLUDED WITH SEALED MOUNTING PLATE)

3/4 in. NPT PLUG (1) PROVIDEDUSE A FLAT HEAD SCREWDRIVER OR COIN TO REMOVE.APPLY THREAD SEALANT. SCREW NPT BACK INTO BACK BOX

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65)COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATION.

#6 O-RING USE TO SEALBACK BOX MOUNTING HOLES

(4) PROVIDED

IP67

A

5 CONDUCTORWIRE HARNESS

SERVICE PIN (1) PROVIDED

ROTATE BOTTOM END OFBATTERY UPWARD FOR REMOVAL

HILOW FACTORY DEFAULT HIGH

VOLUME SWITCH

#6 - 32 x 1/2 in. PHIL. FLATHEAD SCREW(6) PROVIDED

#4 HI-LO SCREW(2) PROVIDED

WHEN REPLACING COVERMAKE SURE COVER IS UNDERHORN CASE TAB AND ROTATECOVER CLOSED. INSERT HI-LOSCREWS AND TIGHTEN.

HORN COVER

REMOVE BOTH HI-LOSCREWS AND ROTATE COVER OPEN AS SHOWN.

HORN CASE SERVICE PINRECEPTOR

ENCLOSEDFLUSH MOUNT

COVER ASSEMBLY

#6 1-1/4 in. SCREW(4) PROVIDED

STI-1401 GASKET

EXISTING ULTYPE 3R RATEDIN-WALL ELECTRICAL BOX

DRILL 3/16 DIA. HOLES1 1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES1 1/4 in. DEEP WHEN ANCHORS ARE NOT USED

PLASTIC WALL ANCHOR(4) PROVIDED

LOCKING TABDRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THEBREAKWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

CONDUIT INSERT(2) PROVIDED

PLASTIC WALL ANCHOR(4) PROVIDED

#8x10 WALL ANCHOR(4) PROVIDED

INSERT(2) PROVIDED

#8x10 WALL ANCHOR(4) PROVIDED

PLASTIC WALL ANCHOR(4) PROVIDED

Fit appropriate conduit weather gasket to conduit. Then fit gasket to insert or directly to the housing knock-out. For additional seal reliability a bead of silicone may be applied to conduit fitting.

Fig. 3 - Flush Mount with add-on Spacer - Models 131** & 141**

BREAK OFF ALL (4) OF THE CONDUIT WINDOWS AND TABSTHEN TRIM SHARP EDGES BEFORE INSTALLATION

STI-1331 SPACER

CONDUIT INSERT(2) PROVIDED

INSERT(2) PROVIDED

#6 x 2-1/2 in. SCREW(4) PROVIDED

GASKET CAN BE CUT TOINSTALL BEHIND CONDUIT

G01307 SPACER/WALL GASKET**Models may contain form-in-place gasket on spacer and 1/8” diameter gaskets for conduit areas.

STI-1314 OPTIONAL BACKPLATE -RECOMMENDED WHENMOUNTING TO UNEVEN SURFACE

BREAK OFF ALL (4)OF THE CONDUITWINDOWS AND

TABS THEN TRIMSHARP EDGES

BEFORE INSTALLATION

LOCKING TABDRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THEBREAKWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

LOCKING TABDRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THEBREAKWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

INSERT(2) PROVIDED

CONDUIT INSERT(2) PROVIDED

1/2 in. and 3/4 in.CONDUIT WEATHER GASKET

(2) PROVIDED

PLASTIC WALL ANCHOR(4) PROVIDED

GASKET CAN BE CUT TOINSTALL BEHIND CONDUIT

#6 x 1-1/4 in. SCREW(4) PROVIDED

DRILL 3/16 DIA. HOLES1-1/4 in. DEEP WHENUSING ANCHORSDRILL 7/64 DIA. HOLES1-1/4 in. DEEP WHENANCHORS ARE NOT USED

PLASTIC WALL ANCHOR(4) PROVIDED

DRILL 3/16 DIA. HOLES1-1/4 in. DEEP WHENUSING ANCHORSDRILL 7/64 DIA. HOLES1-1/4 in. DEEP WHENANCHORS ARE NOT USED

1/2 in. and3/4 in. CONDUITWEATHER GASKET(2) PROVIDEDG01331

SPACER/WALL GASKET

BREAK OFF ALL (4) OF THE CONDUIT WINDOWS AND TABSTHEN TRIM SHARP EDGES BEFORE INSTALLATION

STI-1331 SPACER

CONDUIT INSERT(2) PROVIDED

INSERT(2) PROVIDED

#6 x 2-1/2 in. SCREW(4) PROVIDED

GASKET CAN BE CUT TOINSTALL BEHIND CONDUIT

G01307 SPACER/WALL GASKET**Models may contain form-in-place gasket on spacer and 1/8” diameter gaskets for conduit areas.

STI-1314 OPTIONAL BACKPLATE -RECOMMENDED WHENMOUNTING TO UNEVEN SURFACE

BREAK OFF ALL (4)OF THE CONDUITWINDOWS AND

TABS THEN TRIMSHARP EDGES

BEFORE INSTALLATION

LOCKING TABDRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THEBREAKWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

LOCKING TABDRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THEBREAKWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

INSERT(2) PROVIDED

CONDUIT INSERT(2) PROVIDED

1/2 in. and 3/4 in.CONDUIT WEATHER GASKET

(2) PROVIDED

PLASTIC WALL ANCHOR(4) PROVIDED

GASKET CAN BE CUT TOINSTALL BEHIND CONDUIT

#6 x 1-1/4 in. SCREW(4) PROVIDED

DRILL 3/16 DIA. HOLES1-1/4 in. DEEP WHENUSING ANCHORSDRILL 7/64 DIA. HOLES1-1/4 in. DEEP WHENANCHORS ARE NOT USED

PLASTIC WALL ANCHOR(4) PROVIDED

DRILL 3/16 DIA. HOLES1-1/4 in. DEEP WHENUSING ANCHORSDRILL 7/64 DIA. HOLES1-1/4 in. DEEP WHENANCHORS ARE NOT USED

1/2 in. and3/4 in. CONDUITWEATHER GASKET(2) PROVIDEDG01331

SPACER/WALL GASKET

Page 3: Universal Stopper Install STI-13000 & STI-14000 Series

Fig. 6 - Enclosed Back Box Mounting Option - Models 134**, 135**, 138**, 139**, 144**, 145**, 148** & 149** NEMA TYPE 3RX

DRILL 3/16 DIA. HOLES 1-1/4 in. DEEP WHENUSING ANCHORS

DRILL 7/64 DIA. HOLES 1-1/4 in. DEEP WHENANCHORS ARE NOT USED

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

#6 x 1-1/4 in. SCREW(4) PROVIDED

STI-1314 OPTIONAL BACKPLATE -RECOMMENDED WHEN MOUNTING TO UNEVEN SURFACE

#6 x 1-1/4 in. SCREW(4) PROVIDED

1/2 in. & 3/4 in. CONDUITWEATHER GASKET

STI-1314 OPTIONAL BACKPLATE -RECOMMENDED WHEN MOUNTING TO UNEVEN SURFACE

DRILL 3/16 DIA. HOLES1-1/4 in. DEEP WHENUSING ANCHORS

DRILL 7/64 DIA. HOLES1-1/4 in. DEEP WHENANCHORS ARE NOT USED

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT USED ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

STI-1401 GASKET

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED.INSERT THE BREAKAWAY SEAL (KIT-65)COMPLETELY INTO THE LOCKING TAB.*NOT USED ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

DRILL 3/16 DIA. HOLES1-1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES1-1/4 in. DEEP WHEN ANCHORS ARE NOT USED

#6 x 1-1/4 in. SCREW(4) PROVIDED

IP67 GROMMET FOR REMOTE CABLE OPTIONDRILL 5/8 in. (16mm)

(INCLUDED WITH REMOTE OPTION)DRILL POINT CENTER LOCATED ON

BACK SIDE OF MOUNTING PLATE

DRILL 3/16 DIA. HOLES 1-1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES 1-1/4 in. DEEP WHEN ANCHORS ARE NOT USED

#6 x 1-1/4 in. SCREW(4) PROVIDED

#6 - 32 x 1/2 in. PHIL. PANHEAD SCREW(2) PROVIDED SEALED MOUNTING PLATE (SHOWN)

LOCATE GROMET AS NEEDEDDRILL 5/8 in (16mm) HOLEINSERT GROMET AS SHOWN

FEED WIRES THROUGH GROMET(INCLUDED WITH SEALED MOUNTING PLATE)

3/4 in. NPT PLUG (1) PROVIDEDUSE A FLAT HEAD SCREWDRIVER OR COIN TO REMOVE.APPLY THREAD SEALANT. SCREW NPT BACK INTO BACK BOX

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65)COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATION.

#6 O-RING USE TO SEALBACK BOX MOUNTING HOLES

(4) PROVIDED

IP67

A

5 CONDUCTORWIRE HARNESS

SERVICE PIN (1) PROVIDED

ROTATE BOTTOM END OFBATTERY UPWARD FOR REMOVAL

HILOW FACTORY DEFAULT HIGH

VOLUME SWITCH

#6 - 32 x 1/2 in. PHIL. FLATHEAD SCREW(6) PROVIDED

#4 HI-LO SCREW(2) PROVIDED

WHEN REPLACING COVERMAKE SURE COVER IS UNDERHORN CASE TAB AND ROTATECOVER CLOSED. INSERT HI-LOSCREWS AND TIGHTEN.

HORN COVER

REMOVE BOTH HI-LOSCREWS AND ROTATE COVER OPEN AS SHOWN.

HORN CASE SERVICE PINRECEPTOR

ENCLOSEDFLUSH MOUNT

COVER ASSEMBLY

#6 1-1/4 in. SCREW(4) PROVIDED

STI-1401 GASKET

EXISTING ULTYPE 3R RATEDIN-WALL ELECTRICAL BOX

DRILL 3/16 DIA. HOLES1 1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES1 1/4 in. DEEP WHEN ANCHORS ARE NOT USED

PLASTIC WALL ANCHOR(4) PROVIDED

LOCKING TABDRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THEBREAKWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

CONDUIT INSERT(2) PROVIDED

PLASTIC WALL ANCHOR(4) PROVIDED

#8x10 WALL ANCHOR(4) PROVIDED

INSERT(2) PROVIDED

#8x10 WALL ANCHOR(4) PROVIDED

PLASTIC WALL ANCHOR(4) PROVIDED

DRILL 3/16 DIA. HOLES 1-1/4 in. DEEP WHENUSING ANCHORS

DRILL 7/64 DIA. HOLES 1-1/4 in. DEEP WHENANCHORS ARE NOT USED

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

#6 x 1-1/4 in. SCREW(4) PROVIDED

STI-1314 OPTIONAL BACKPLATE -RECOMMENDED WHEN MOUNTING TO UNEVEN SURFACE

#6 x 1-1/4 in. SCREW(4) PROVIDED

1/2 in. & 3/4 in. CONDUITWEATHER GASKET

STI-1314 OPTIONAL BACKPLATE -RECOMMENDED WHEN MOUNTING TO UNEVEN SURFACE

DRILL 3/16 DIA. HOLES1-1/4 in. DEEP WHENUSING ANCHORS

DRILL 7/64 DIA. HOLES1-1/4 in. DEEP WHENANCHORS ARE NOT USED

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT USED ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

STI-1401 GASKET

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED.INSERT THE BREAKAWAY SEAL (KIT-65)COMPLETELY INTO THE LOCKING TAB.*NOT USED ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

DRILL 3/16 DIA. HOLES1-1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES1-1/4 in. DEEP WHEN ANCHORS ARE NOT USED

#6 x 1-1/4 in. SCREW(4) PROVIDED

IP67 GROMMET FOR REMOTE CABLE OPTIONDRILL 5/8 in. (16mm)

(INCLUDED WITH REMOTE OPTION)DRILL POINT CENTER LOCATED ON

BACK SIDE OF MOUNTING PLATE

DRILL 3/16 DIA. HOLES 1-1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES 1-1/4 in. DEEP WHEN ANCHORS ARE NOT USED

#6 x 1-1/4 in. SCREW(4) PROVIDED

#6 - 32 x 1/2 in. PHIL. PANHEAD SCREW(2) PROVIDED SEALED MOUNTING PLATE (SHOWN)

LOCATE GROMET AS NEEDEDDRILL 5/8 in (16mm) HOLEINSERT GROMET AS SHOWN

FEED WIRES THROUGH GROMET(INCLUDED WITH SEALED MOUNTING PLATE)

3/4 in. NPT PLUG (1) PROVIDEDUSE A FLAT HEAD SCREWDRIVER OR COIN TO REMOVE.APPLY THREAD SEALANT. SCREW NPT BACK INTO BACK BOX

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65)COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATION.

#6 O-RING USE TO SEALBACK BOX MOUNTING HOLES

(4) PROVIDED

IP67

A

5 CONDUCTORWIRE HARNESS

SERVICE PIN (1) PROVIDED

ROTATE BOTTOM END OFBATTERY UPWARD FOR REMOVAL

HILOW FACTORY DEFAULT HIGH

VOLUME SWITCH

#6 - 32 x 1/2 in. PHIL. FLATHEAD SCREW(6) PROVIDED

#4 HI-LO SCREW(2) PROVIDED

WHEN REPLACING COVERMAKE SURE COVER IS UNDERHORN CASE TAB AND ROTATECOVER CLOSED. INSERT HI-LOSCREWS AND TIGHTEN.

HORN COVER

REMOVE BOTH HI-LOSCREWS AND ROTATE COVER OPEN AS SHOWN.

HORN CASE SERVICE PINRECEPTOR

ENCLOSEDFLUSH MOUNT

COVER ASSEMBLY

#6 1-1/4 in. SCREW(4) PROVIDED

STI-1401 GASKET

EXISTING ULTYPE 3R RATEDIN-WALL ELECTRICAL BOX

DRILL 3/16 DIA. HOLES1 1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES1 1/4 in. DEEP WHEN ANCHORS ARE NOT USED

PLASTIC WALL ANCHOR(4) PROVIDED

LOCKING TABDRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THEBREAKWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

CONDUIT INSERT(2) PROVIDED

PLASTIC WALL ANCHOR(4) PROVIDED

#8x10 WALL ANCHOR(4) PROVIDED

INSERT(2) PROVIDED

#8x10 WALL ANCHOR(4) PROVIDED

PLASTIC WALL ANCHOR(4) PROVIDED

Fig. 5 - Enclosed Flush Mounting Option - Models 133** & 143** NEMA TYPE 3RX

STI-134** STI-144**

STI-135** STI-145**

STI-136** STI-146**

STI-137** STI-147**

STI-138** STI-148**

STI-139** STI-149**

STI-13A** STI-14A**

STI-13B** STI-14B**

Back BoxConduit Thread

3/4 NPT

20mm

3/4 NPT

20mm

Electrical BoxType

North America

European

European

North America

Models

DRILL 3/16 DIA. HOLES 1-1/4 in. DEEP WHENUSING ANCHORS

DRILL 7/64 DIA. HOLES 1-1/4 in. DEEP WHENANCHORS ARE NOT USED

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

#6 x 1-1/4 in. SCREW(4) PROVIDED

STI-1314 OPTIONAL BACKPLATE -RECOMMENDED WHEN MOUNTING TO UNEVEN SURFACE

#6 x 1-1/4 in. SCREW(4) PROVIDED

1/2 in. & 3/4 in. CONDUITWEATHER GASKET

STI-1314 OPTIONAL BACKPLATE -RECOMMENDED WHEN MOUNTING TO UNEVEN SURFACE

DRILL 3/16 DIA. HOLES1-1/4 in. DEEP WHENUSING ANCHORS

DRILL 7/64 DIA. HOLES1-1/4 in. DEEP WHENANCHORS ARE NOT USED

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT USED ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

STI-1401 GASKET

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED.INSERT THE BREAKAWAY SEAL (KIT-65)COMPLETELY INTO THE LOCKING TAB.*NOT USED ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

DRILL 3/16 DIA. HOLES1-1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES1-1/4 in. DEEP WHEN ANCHORS ARE NOT USED

#6 x 1-1/4 in. SCREW(4) PROVIDED

IP67 GROMMET FOR REMOTE CABLE OPTIONDRILL 5/8 in. (16mm)

(INCLUDED WITH REMOTE OPTION)DRILL POINT CENTER LOCATED ON

BACK SIDE OF MOUNTING PLATE

DRILL 3/16 DIA. HOLES 1-1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES 1-1/4 in. DEEP WHEN ANCHORS ARE NOT USED

#6 x 1-1/4 in. SCREW(4) PROVIDED

#6 - 32 x 1/2 in. PHIL. PANHEAD SCREW(2) PROVIDED SEALED MOUNTING PLATE (SHOWN)

LOCATE GROMET AS NEEDEDDRILL 5/8 in (16mm) HOLEINSERT GROMET AS SHOWN

FEED WIRES THROUGH GROMET(INCLUDED WITH SEALED MOUNTING PLATE)

3/4 in. NPT PLUG (1) PROVIDEDUSE A FLAT HEAD SCREWDRIVER OR COIN TO REMOVE.APPLY THREAD SEALANT. SCREW NPT BACK INTO BACK BOX

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65)COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATION.

#6 O-RING USE TO SEALBACK BOX MOUNTING HOLES

(4) PROVIDED

IP67

A

5 CONDUCTORWIRE HARNESS

SERVICE PIN (1) PROVIDED

ROTATE BOTTOM END OFBATTERY UPWARD FOR REMOVAL

HILOW FACTORY DEFAULT HIGH

VOLUME SWITCH

#6 - 32 x 1/2 in. PHIL. FLATHEAD SCREW(6) PROVIDED

#4 HI-LO SCREW(2) PROVIDED

WHEN REPLACING COVERMAKE SURE COVER IS UNDERHORN CASE TAB AND ROTATECOVER CLOSED. INSERT HI-LOSCREWS AND TIGHTEN.

HORN COVER

REMOVE BOTH HI-LOSCREWS AND ROTATE COVER OPEN AS SHOWN.

HORN CASE SERVICE PINRECEPTOR

ENCLOSEDFLUSH MOUNT

COVER ASSEMBLY

#6 1-1/4 in. SCREW(4) PROVIDED

STI-1401 GASKET

EXISTING ULTYPE 3R RATEDIN-WALL ELECTRICAL BOX

DRILL 3/16 DIA. HOLES1 1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES1 1/4 in. DEEP WHEN ANCHORS ARE NOT USED

PLASTIC WALL ANCHOR(4) PROVIDED

LOCKING TABDRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THEBREAKWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

CONDUIT INSERT(2) PROVIDED

PLASTIC WALL ANCHOR(4) PROVIDED

#8x10 WALL ANCHOR(4) PROVIDED

INSERT(2) PROVIDED

#8x10 WALL ANCHOR(4) PROVIDED

PLASTIC WALL ANCHOR(4) PROVIDED

Fig. 7 - Horn Option Models STI-13x20 & STI-13x30 - Wiring Details - Remote Power/Relay Options*9V battery acts as a backup power when using remote power

Remove service pin and horn should sound. Close covers and horn should silence. When performing annual battery test/replacement or when servicing alarm system, insert service pin to prevent horn from sounding. Remember to remove to return to normal operation.

DRILL 3/16 DIA. HOLES 1-1/4 in. DEEP WHENUSING ANCHORS

DRILL 7/64 DIA. HOLES 1-1/4 in. DEEP WHENANCHORS ARE NOT USED

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

#6 x 1-1/4 in. SCREW(4) PROVIDED

STI-1314 OPTIONAL BACKPLATE -RECOMMENDED WHEN MOUNTING TO UNEVEN SURFACE

#6 x 1-1/4 in. SCREW(4) PROVIDED

1/2 in. & 3/4 in. CONDUITWEATHER GASKET

STI-1314 OPTIONAL BACKPLATE -RECOMMENDED WHEN MOUNTING TO UNEVEN SURFACE

DRILL 3/16 DIA. HOLES1-1/4 in. DEEP WHENUSING ANCHORS

DRILL 7/64 DIA. HOLES1-1/4 in. DEEP WHENANCHORS ARE NOT USED

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT USED ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

STI-1401 GASKET

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED.INSERT THE BREAKAWAY SEAL (KIT-65)COMPLETELY INTO THE LOCKING TAB.*NOT USED ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

DRILL 3/16 DIA. HOLES1-1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES1-1/4 in. DEEP WHEN ANCHORS ARE NOT USED

#6 x 1-1/4 in. SCREW(4) PROVIDED

IP67 GROMMET FOR REMOTE CABLE OPTIONDRILL 5/8 in. (16mm)

(INCLUDED WITH REMOTE OPTION)DRILL POINT CENTER LOCATED ON

BACK SIDE OF MOUNTING PLATE

DRILL 3/16 DIA. HOLES 1-1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES 1-1/4 in. DEEP WHEN ANCHORS ARE NOT USED

#6 x 1-1/4 in. SCREW(4) PROVIDED

#6 - 32 x 1/2 in. PHIL. PANHEAD SCREW(2) PROVIDED SEALED MOUNTING PLATE (SHOWN)

LOCATE GROMET AS NEEDEDDRILL 5/8 in (16mm) HOLEINSERT GROMET AS SHOWN

FEED WIRES THROUGH GROMET(INCLUDED WITH SEALED MOUNTING PLATE)

3/4 in. NPT PLUG (1) PROVIDEDUSE A FLAT HEAD SCREWDRIVER OR COIN TO REMOVE.APPLY THREAD SEALANT. SCREW NPT BACK INTO BACK BOX

LOCKING TAB DRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THE BREAKAWAY SEAL (KIT-65)COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATION.

#6 O-RING USE TO SEALBACK BOX MOUNTING HOLES

(4) PROVIDED

IP67

A

5 CONDUCTORWIRE HARNESS

SERVICE PIN (1) PROVIDED

ROTATE BOTTOM END OFBATTERY UPWARD FOR REMOVAL

HILOW FACTORY DEFAULT HIGH

VOLUME SWITCH

#6 - 32 x 1/2 in. PHIL. FLATHEAD SCREW(6) PROVIDED

#4 HI-LO SCREW(2) PROVIDED

WHEN REPLACING COVERMAKE SURE COVER IS UNDERHORN CASE TAB AND ROTATECOVER CLOSED. INSERT HI-LOSCREWS AND TIGHTEN.

HORN COVER

REMOVE BOTH HI-LOSCREWS AND ROTATE COVER OPEN AS SHOWN.

HORN CASE SERVICE PINRECEPTOR

ENCLOSEDFLUSH MOUNT

COVER ASSEMBLY

#6 1-1/4 in. SCREW(4) PROVIDED

STI-1401 GASKET

EXISTING ULTYPE 3R RATEDIN-WALL ELECTRICAL BOX

DRILL 3/16 DIA. HOLES1 1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES1 1/4 in. DEEP WHEN ANCHORS ARE NOT USED

PLASTIC WALL ANCHOR(4) PROVIDED

LOCKING TABDRILL 1/8 in. HOLE WHILE COVER IS CLOSED. INSERT THEBREAKWAY SEAL (KIT-65) COMPLETELY INTO THE LOCKING TAB.*NOT FOR USE ON FIRE OR EMERGENCY SIGNAL APPLICATIONS.

CONDUIT INSERT(2) PROVIDED

PLASTIC WALL ANCHOR(4) PROVIDED

#8x10 WALL ANCHOR(4) PROVIDED

INSERT(2) PROVIDED

#8x10 WALL ANCHOR(4) PROVIDED

PLASTIC WALL ANCHOR(4) PROVIDED

Wire Description Red 12VDC - 24VDCBlack 12VDC - 24VDCBlue CommonGreen NC - Norm ClosedYellow NO - Norm Open

Horn Activation

Page 4: Universal Stopper Install STI-13000 & STI-14000 Series

2306 Airport Rd • Waterford, MI 48327, USAPhone: 248-673-9898 • Fax: 248-673-1246

[email protected] • www.sti-usa.com

Taylor House • 34 Sherwood Road • BromsgroveWorcestershire • B60 3DR • England • Tel: +44 (0)1527 520 999

Fax: +44 (0)1527 501 999 • [email protected] • www.sti-emea.comSubject to changewithout notice.Printed in USA

Univ Stopper ISFeb2019

Important Notice (when used on fire systems) The Universal Stopper is intended to be used in areas where the incidence of false fire alarms from manual pull stations is high or has proven to be a serious problem. Any disadvantage of this device is more than balanced when one considers the consequences of false fire alarms, especially if fire service personnel and equipment are responding to a false fire alarm when they are needed for a real fire somewhere else. Add to this, the disruption to the facility when false alarms occur. If you have, or may have, a problem with false fire alarms or physical/weather damage to your fire alarm activation devices, the Universal Stopper could prove invaluable.

Avis important (en cas d’utilisation sur les réseaux d’incendie) Le Universal Stopper est destiné à être utilisé dans les zones où l’occurrence de fausses alertes d’incendie issues d’avertisseurs d’incendie manuels est élevée ou présente un problème grave. Un quelconque inconvénient de ce dispositif est vite contrecarré par les conséquences des fausses alertes d’incendie, surtout lorsque le personnel et l’équipement des services d’incendie réagissent à une fausse alerte d’incendie alors que leur intervention ailleurs sur un vrai incendie s’avère nécessaire en même temps.À cela s’ajoute l’agitation éprouvée dans l’établissement au moment du déclenchement d’une fausse alerte. Si vous rencontrez, ou risquez de rencontrer, un problème avec les fausses alertes d’incendie ou avec l’éventuel endommagement par effet climatique ou physique de vos dispositifs de déclenchement des alertes d’incendie, le Universal Stopper pourra alors se révéler d’une valeur inestimable.

WarrantyThree year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components). Electronic warranty form at www.sti-usa.com/wc14.

WARNING: This product can expose you to chemicals including Dichloromethane, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

#4 HI-LO SCREW(2) PROVIDED

SERVICE PIN (1) PROVIDEDSERVICE PIN RECEPTOR

HORN COVER

TO REMOVE SOUNDER ASSEMBLY,REMOVE 2 HI-LO, ROTATE THE REAR OFTHE SOUNDER ASSEMBLY OFF THEFRONT TAB OF THE MESSAGE HOOD.

TO INSTALL SOUNDER ASSEMBLY,REVERSE THE REMOVAL PROCESS.

OPTIONAL REMOTE WIRE HARNESS

A

CR123A

5 CONDUCTOR WIRE HARNESS(REFER TO WIRING INSTRUCTIONS ON FIG. 7)

VIEW A

VOLUME JUMPER

FACTORY DEFAULT HIGH

FLASHING LED’sDO NOT TOUCH

WHEN REPLACINGCOVER MAKE SURECOVER IS UNDERHORN CASE TABAND ROTATE COVERCLOSED. INSERTHI-LO SCREWSAND TIGHTEN

VIEW A

VOLUME JUMPERHI OR LOW

(DEFAULT HI)

A

+

-

VOLUME JUMPERHI OR LOW

(DEFAULT HI)

CR123A

5 CONDUCTOR WIRE HARNESS(REFER TO WIRING

INSTRUCTIONS ON FIG. 7)

VIEW A

LED LIGHTS

Fig. 8 - Horn Option Models STI-14x20 & STI-14x30 - Wiring Details - Remove Power/Relay Options*CR123A battery acts as a backup power when using remote power

TO REPLACE BATTERY REMOVE BOTH HI-LO SCREWS AND ROTATE COVER

OPEN AS SHOWN

See FIG. 7 for wire description and activation instructions.

#4 HI-LO SCREW(2) PROVIDED

SERVICE PIN (1) PROVIDEDSERVICE PIN RECEPTOR

HORN COVER

TO REMOVE SOUNDER ASSEMBLY,REMOVE 2 HI-LO, ROTATE THE REAR OFTHE SOUNDER ASSEMBLY OFF THEFRONT TAB OF THE MESSAGE HOOD.

TO INSTALL SOUNDER ASSEMBLY,REVERSE THE REMOVAL PROCESS.

OPTIONAL REMOTE WIRE HARNESS

A

CR123A

5 CONDUCTOR WIRE HARNESS(REFER TO WIRING INSTRUCTIONS ON FIG. 7)

VIEW A

VOLUME JUMPER

FACTORY DEFAULT HIGH

FLASHING LED’sDO NOT TOUCH

WHEN REPLACINGCOVER MAKE SURECOVER IS UNDERHORN CASE TABAND ROTATE COVERCLOSED. INSERTHI-LO SCREWSAND TIGHTEN

VIEW A

VOLUME JUMPERHI OR LOW

(DEFAULT HI)

A

+

-

VOLUME JUMPERHI OR LOW

(DEFAULT HI)

CR123A

5 CONDUCTOR WIRE HARNESS(REFER TO WIRING

INSTRUCTIONS ON FIG. 7)

VIEW A

LED LIGHTS

Page 5: Universal Stopper Install STI-13000 & STI-14000 Series

2306 Airport Road • Waterford, Michigan 48327-1209Phone: 248-673-9898 • Fax: 248-673-1246Toll Free: 800-888-4784 • E-mail: [email protected]: www.sti-usa.com

Taylor House • 34 Sherwood Road • BromsgroveWorcestershire • B60 3DR • England Tel: +44 (0)1527 520 999 • Fax: +44 (0)1527 501 999 E-mail: [email protected] • Web: www.sti-emea.com

*SS2xx4 and LT1-UL NOTES: For access control installations, power for the LT-1UL Timer must be supplied by a power source listed to UL294. When used for access control, this device shall be used as part of an access controlled egress door system. It is up to the local AHJ to allow use of this device in place of an automatic sensor. For higher security installations, lower time limits should be used. For SS2xx4 and LT1-UL the enclosed timer is to be used and installed per the enclosed LT-1UL installation sheet. *SS2xx4 and LT1-UL maximum rating 30 VDC 3A.

REMARQUES POUR *SS2xx4 et LT1-UL: Pour les installations de contrôle d’accès, l’alimentation de la minuterie LT-1UL doit être fournie par une source homologuée UL294. Lorsque cet appareil est utilisé aux fins de contrôle d’accès, il doit faire partie d’un système de porte de sortie à accès contrôlé. Il incombe donc à l’AHJ local d’autoriser l’utilisation de cet appareil au lieu d’un capteur automatique. Pour les installations de sécurité plus renforcée, des délais inférieurs doivent être utilisés. Pour les modèles SS2xx4 et LT1-UL, la minuterie intégrée doit être installée et utilisée suivant la fiche d’installation LT-1UL fournie. La cote maximale des modèles *SS2xx 4 et LT1-UL est de 30 VCC 3A.

WARNING: This product can expose you to chemicals including Bisphenol A, which is known to the State of California to cause reproductive harm and Dichloromethane, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov.

Three year warranty or a one year limited warranty (from date of purchase) on most products. See website for details. Electronic warranty form at www.sti-usa.com/wc14.

1027IS OCT2018

INSTALLATION OF SS2xx0, SS2xx1, SS2xx3, SS2xx4 SERIES STOPPER® STATIONAll specifications and information shown were current as of publication, and are subject to change without notice.

“A” - Contact DepthSS2xy0* 2.16”SS2xy1 2.04”SS2xy3* 2.13”SS2xy4 2.04”

* If extra depth needed in electrical box order KIT-102722-color.

NC

NO1

23

4

STRIP 1/4 in. OF WIRE INSULATIONINSERT IN TERMINAL (AS SHOWN) THENUSING A PHILLIPS SCREWDRIVER TURNCLOCKWISE UNTIL TIGHT.

SEPARATION OF TERMINAL ASSEMBLY.FROM BUTTON ASSEMBLY IS AS FOLLOWS:GRASP TERMINAL HOUSING AND USING THUMBAPPLY PRESSURE DOWNWARD, REMOVE TERMINAL.

REMOVAL OF TERMINAL BLOCKFROM TERMINAL HOUSING: INSERTSMALL SCREWDRIVER (AS SHOWN)AND PRY UPWARD, REMOVE TERMINAL.

TERMINAL BLOCKRELEASE LEVERMUST FACE UPWARDAS SHOWN FOR SWITCHTO FUNCTION CORRECTLY.

ELECTRICAL TERMINAL BLOCKUP TO 3 TERMINALS MAY BE USED

INSERT NOTCH, AS SHOWNTHEN ROTATE UPWARD

TERMINAL BLOCKKIT-E10196 NO (1) PROVIDEDKIT-E10198 NC (1) PROVIDED

SEE VIEW IN DIRECTION OF ARROWFOR CONTACT INDENTIFIER LOCATIONSUP TO (3) TERMINALS MAY BE USED FOR EACHSTATION ASSEMBLY.

OUTGOING

INCOMING

SCREWS #6-32 x 1OUTLET BOX (2) PROVIDED.

SCREWS #6-32 x 1.50 WHENUSING KIT-102722-COLOR SPACER

(SEE REVERSE SIDE).#10-32 x 3/8 in. GROUND SCREW

(1) PROVIDED

BUTTON LOCK NUT

BACKPLATE

A

EXISTING STANDARDSINGLE GANGBOX

HOUSING INDEXING SLOTS

BACKPLATE ASSEMBLY(SEE REVERSE SIDE)

5/8” SPACERKIT-102722-B (BLUE)

KIT-102722-G (GREEN)KIT-102722-R (RED)

KIT-102722-W (WHITE)KIT-102722-Y (YELLOW)

M10274-W OCTAGON SHELLRED, GREEN, YELLOW, WHITE AND BLUE

E10105 MOMENTARY BUTTON (#4)* KIT-H18062 KEYS(2) PROVIDED

M10271 STATION HOUSINGRED, GREEN, YELLOW,

WHITE AND BLUE

E10100 PUSH/TURNRESET BUTTON (#1)

KEY BUTTON (#3)KEY REQUIRED TO ACTIVATE - INACTIVATE MODE KEY CAN BE REMOVED

#8-32 x 3/8 in. BUTTON HEADSCREW (1) PROVIDED

KIT-H19030 KEYS(2) PROVIDED

E10102 KEY RESET SWITCH

OCTAGON KEY RESET BUTTON (#0)RED, GREEN, YELLOW, WHITEAND BLUE

M02050

PUSH

PUSH

HERE

MESSAGEAREA

NOTE: TO PROVIDE ADEQUATECLEARANCE FOR INSTALLATION,

MAY REQUIRE: KIT-102722 5/8” SPACER

PRODUCT DIMENSIONS

3.25 in.(82mm)

4.87 in.(124mm)

1.62 in.(41mm) 2.25 in.

(57mm)

“A”

UL294 Performance Levels: Line Security: IAttack: I

Endurance: IVStandby Power: I

Page 6: Universal Stopper Install STI-13000 & STI-14000 Series

2306 Airport Road • Waterford, Michigan 48327-1209Phone: 248-673-9898 • Fax: 248-673-1246Toll Free: 800-888-4784 • E-mail: [email protected]: www.sti-usa.com

Taylor House • 34 Sherwood Road • BromsgroveWorcestershire • B60 3DR • England Tel: +44 (0)1527 520 999 • Fax: +44 (0)1527 501 999 E-mail: [email protected] • Web: www.sti-emea.com

1027IS OCT2018

INSTALLATION OF SS2xx0, SS2xx1, SS2xx3, SS2xx4 SERIES STOPPER® STATIONAll specifications and information shown were current as of publication, and are subject to change without notice.

ALL TERMINALS ACCEPT TWO 12 TO 18 (AWG)

VOLTAGERATED AVERAGE CURRENT

250 VDC 1 AMP

600 VAC 3 AMP

NOTE: SS-2XX4/LT CONTACTS ON FORM C TIMER RATED: 120 VAC, 3A 28 VDC, 3A

NC

NO1

23

4

STRIP 1/4 in. OF WIRE INSULATIONINSERT IN TERMINAL (AS SHOWN) THENUSING A PHILLIPS SCREWDRIVER TURNCLOCKWISE UNTIL TIGHT.

SEPARATION OF TERMINAL ASSEMBLY.FROM BUTTON ASSEMBLY IS AS FOLLOWS:GRASP TERMINAL HOUSING AND USING THUMBAPPLY PRESSURE DOWNWARD, REMOVE TERMINAL.

REMOVAL OF TERMINAL BLOCKFROM TERMINAL HOUSING: INSERTSMALL SCREWDRIVER (AS SHOWN)AND PRY UPWARD, REMOVE TERMINAL.

TERMINAL BLOCKRELEASE LEVERMUST FACE UPWARDAS SHOWN FOR SWITCHTO FUNCTION CORRECTLY.

ELECTRICAL TERMINAL BLOCKUP TO 3 TERMINALS MAY BE USED

INSERT NOTCH, AS SHOWNTHEN ROTATE UPWARD

TERMINAL BLOCKKIT-E10196 NO (1) PROVIDEDKIT-E10198 NC (1) PROVIDED

SEE VIEW IN DIRECTION OF ARROWFOR CONTACT INDENTIFIER LOCATIONSUP TO (3) TERMINALS MAY BE USED FOR EACHSTATION ASSEMBLY.

OUTGOING

INCOMING

SCREWS #6-32 x 1OUTLET BOX (2) PROVIDED.

SCREWS #6-32 x 1.50 WHENUSING KIT-102722-COLOR SPACER

(SEE REVERSE SIDE).#10-32 x 3/8 in. GROUND SCREW

(1) PROVIDED

BUTTON LOCK NUT

BACKPLATE

A

EXISTING STANDARDSINGLE GANGBOX

HOUSING INDEXING SLOTS

BACKPLATE ASSEMBLY(SEE REVERSE SIDE)

5/8” SPACERKIT-102722-B (BLUE)

KIT-102722-G (GREEN)KIT-102722-R (RED)

KIT-102722-W (WHITE)KIT-102722-Y (YELLOW)

M10274-W OCTAGON SHELLRED, GREEN, YELLOW, WHITE AND BLUE

E10105 MOMENTARY BUTTON (#4)* KIT-H18062 KEYS(2) PROVIDED

M10271 STATION HOUSINGRED, GREEN, YELLOW,

WHITE AND BLUE

E10100 PUSH/TURNRESET BUTTON (#1)

KEY BUTTON (#3)KEY REQUIRED TO ACTIVATE - INACTIVATE MODE KEY CAN BE REMOVED

#8-32 x 3/8 in. BUTTON HEADSCREW (1) PROVIDED

KIT-H19030 KEYS(2) PROVIDED

E10102 KEY RESET SWITCH

OCTAGON KEY RESET BUTTON (#0)RED, GREEN, YELLOW, WHITEAND BLUE

M02050

PUSH

PUSH

HERE

MESSAGEAREA

NOTE: TO PROVIDE ADEQUATECLEARANCE FOR INSTALLATION,

MAY REQUIRE: KIT-102722 5/8” SPACER

PRODUCT DIMENSIONS

3.25 in.(82mm)

4.87 in.(124mm)

1.62 in.(41mm) 2.25 in.

(57mm)

“A”

NC

NO1

23

4

STRIP 1/4 in. OF WIRE INSULATIONINSERT IN TERMINAL (AS SHOWN) THENUSING A PHILLIPS SCREWDRIVER TURNCLOCKWISE UNTIL TIGHT.

SEPARATION OF TERMINAL ASSEMBLY.FROM BUTTON ASSEMBLY IS AS FOLLOWS:GRASP TERMINAL HOUSING AND USING THUMBAPPLY PRESSURE DOWNWARD, REMOVE TERMINAL.

REMOVAL OF TERMINAL BLOCKFROM TERMINAL HOUSING: INSERTSMALL SCREWDRIVER (AS SHOWN)AND PRY UPWARD, REMOVE TERMINAL.

TERMINAL BLOCKRELEASE LEVERMUST FACE UPWARDAS SHOWN FOR SWITCHTO FUNCTION CORRECTLY.

ELECTRICAL TERMINAL BLOCKUP TO 3 TERMINALS MAY BE USED

INSERT NOTCH, AS SHOWNTHEN ROTATE UPWARD

TERMINAL BLOCKKIT-E10196 NO (1) PROVIDEDKIT-E10198 NC (1) PROVIDED

SEE VIEW IN DIRECTION OF ARROWFOR CONTACT INDENTIFIER LOCATIONSUP TO (3) TERMINALS MAY BE USED FOR EACHSTATION ASSEMBLY.

OUTGOING

INCOMING

SCREWS #6-32 x 1OUTLET BOX (2) PROVIDED.

SCREWS #6-32 x 1.50 WHENUSING KIT-102722-COLOR SPACER

(SEE REVERSE SIDE).#10-32 x 3/8 in. GROUND SCREW

(1) PROVIDED

BUTTON LOCK NUT

BACKPLATE

A

EXISTING STANDARDSINGLE GANGBOX

HOUSING INDEXING SLOTS

BACKPLATE ASSEMBLY(SEE REVERSE SIDE)

5/8” SPACERKIT-102722-B (BLUE)

KIT-102722-G (GREEN)KIT-102722-R (RED)

KIT-102722-W (WHITE)KIT-102722-Y (YELLOW)

M10274-W OCTAGON SHELLRED, GREEN, YELLOW, WHITE AND BLUE

E10105 MOMENTARY BUTTON (#4)* KIT-H18062 KEYS(2) PROVIDED

M10271 STATION HOUSINGRED, GREEN, YELLOW,

WHITE AND BLUE

E10100 PUSH/TURNRESET BUTTON (#1)

KEY BUTTON (#3)KEY REQUIRED TO ACTIVATE - INACTIVATE MODE KEY CAN BE REMOVED

#8-32 x 3/8 in. BUTTON HEADSCREW (1) PROVIDED

KIT-H19030 KEYS(2) PROVIDED

E10102 KEY RESET SWITCH

OCTAGON KEY RESET BUTTON (#0)RED, GREEN, YELLOW, WHITEAND BLUE

M02050

PUSH

PUSH

HERE

MESSAGEAREA

NOTE: TO PROVIDE ADEQUATECLEARANCE FOR INSTALLATION,

MAY REQUIRE: KIT-102722 5/8” SPACER

PRODUCT DIMENSIONS

3.25 in.(82mm)

4.87 in.(124mm)

1.62 in.(41mm) 2.25 in.

(57mm)

“A”